HomeMy WebLinkAboutPRODUCT APPROVAL - 1 INCH NAIL STRIP - DUPLICATE2160 SW Poma Drive
Palm City, FL 34990
Compliant with Florida Building Code 2017 (61h ed.)
Compliant with Florida Product Approval Rule # 611320-3 ftlyiY
Compliant: Keystone Certifications ED
at LuCie Cunt,
Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec.1S07.4.2
Yield strength: SO ksi min.; Attached to min.1S/32" plywood or
Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.)
Rib Height 1"
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru
bottom of support.
Adheesive/Sealant : Bostik 915T"" Chem -Chalk one component, polyurethane adhesive with
3/1V continuous bead application along base of male rib vertical flange at each panel
Beak
Underlayment: To be compliant with FBC Sec 1SO7.1.1
Slope: Shall be in compliance with FBC Sec.1S07.
11 Details: Table A _ Allowable Loads METHOD 1 METHOD 2
SN PRESSURE* T -86 PSF Main field -97.25 PSF Perimeter
ENER SPACING 6" O.C. 1 6" O.C.
I ADHESIVE Not required 3/16" continuous bead
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527
UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2
UL1897-04 is equivalent to Test Standard
2:1
Certificate of Independence:
Locke; Bowden, P.E. does not have, not will acquire a financial iglp otlin agy�company manufacturing or distributing products
under this evaluation. ��` L D'�f3o, P.
Locke] Bowden, P.E. is not owned, operated, or controlle NmR� �anActurer, or distributing products under this
�
report. " y -, •
v'-A- Vj__ 7,,
X
° - seal
0� °o STATE OF ;
FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
Fastener
#10 x T' Min. per Table "N'
Pancake Head Wood Screw
1" Nail Strip Roof Panel / - \ -- —
T
LSeam Adhesive Application:
Deck: For Method 2
- 15/3Z'or greater Plywood, or Apply 3116" Bead Bostik 915Tm Sealant
- Wood plank Continuous Along Mate Rib Vertical Flange
(Refer to Table "N')
Isometric View
Limitations:
1. Undedayment to be compliance with current Florida Building Code (FBC)2017 6"' ed..
2. Minimum slope to be compliant with Florida Building Code 2017 6t''ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities wfjudsdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6"' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report
FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
16"
3/4"
—I
Panel Profile
16" o.c.
R
Deck: -
15/32" or greater Plywood, or
- Wood plank
Integral Snap Lock
For METHOD 2:
Apply 3/16" Bead Bostik 915Tm Sealant
.Continuous Along Male Rib Vertical Flange
\\ X\ \\ Fastener
#10 x l" Min. per Table "A"
Pancake Head Wood Screw
(Typical Fastening Pattern Across Width)