HomeMy WebLinkAboutPRODUCT APPROVAL - METAL ROOFINGa
Building Code Online Page 1 of 5
r�r�a
BQS Home { Log In { User Registration Hot Topics Submit Surcharge { Stets & Facts { Publications ( contact us { BaS Site Map {. Links { Search {
Product Approval
1B USER: PublleUser
FILE
COPY_
Product Approval Menu > Product or Aooliwtion
Search > Apoliration List > Application Ua�„
®
FL #
Application Type
1
FL11651-R3 LLe
Revision STD LUCIV C'dUNfy b &BINd BtV �
Code Version
2017 REVIEWED FOR COM LIANCE
Application Status
Approved REVIE11�1
r1wTr I i
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
CONCEALED FASTENERS OR ATiACHIJiGYTS
ARE THE RESPONSIBILITY OF TH
CONTRACTOR OR RECORD E
i
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
PLANS AND PERMTT MUST BE KEP JOB
❑ SITE OR NO INSPECTION(S) W , L E MADE
Gulf Coast Supply & Manufacturing, LLC.
4020 S. W. 449th Street ®M� �C
Horseshoe Beach, FL 32648 C
(352) 498-0778
info@gulfcoastsupply.com
Eng David THESE PLANS AND ALL PROPOSED WORK
info@gulfcoastsupply.co NS
REQUIRED BY FIELD INSANY PECTORS THAT
MAY BE NECESSARY IN ORDER TO
David Eng COMPLY WITH ALL APPLICABLE CODES.
14429 SW 2nd PI
Ste G30
Newberry, FL 32669
(352) 498-0778
Info@gulfcoastsupply.com
David Eng
14429 SW 2nd PI
Ste G30
Newberry, FL 32669
(352) 498-0778
david.eng@gulfcoastsupply.com
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Daniel S. Kuhn
PE-75519
Keystone Certifications, Inc.
04/12/2024
Locke Bowden P.E.
® Validation Checklist - Hardcopy Received
FL11651 R3 COI Cert oflndeoendence 2017-10-09.0f
Referenced Standard and Year (of Standard) Standard
FM 4471
TAS 100
TAS 110
TAS 125
UL 1897
UL 580
Year ..
1992
1995
2000
2003
2012
2006
hftn..q //www flnridahiiilding.org/nr/nr anD dtl.asnx?naram=wGEVXQwtDgsQFc5K%2fFr... 10/8/2018
Florida Building Code Online Page 2 of 5
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Method 1 Option D
Date Submitted
10/10/2017
Date Validated
10/12/2017
Date Pending FBC Approval
10/17/2017
Date Approved
12/12/2017
Summary of Products
Go to Page F-1 0 0. Page 1/ 2 0. 0
FL* I Model, Number or Name
11651.1 0.032" Aluminum 5V Crimp
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5PSF
Other: -108.5 psf @ 12" o.c.. Install per manufacturers
details. Not for use in HVHZ Zones.
Description
Min 0.032" 5 V Crimp Aluminum Roof Panel over 15/32"
Plywood
Installation Instructions
FL11651 R3 II FL11651 1 R3 Metal Roof Panel Detail-
s ned f
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 1 R3 0325vCrimo 15-
32Plywood NonHVHZ-sioned.Ddf
Created by Independent Third Party: Yes
11651.2
0.032" Aluminum Gulf Lok
Min 0.032" Aluminum Gulf Lok 16" Wide Roof Panel over
15/32" Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116.0PSF
Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0 psf
@ 5 3/16" o.c. fastener spacing. Install per manufacturers
details. Not for use in HVHZ Zones.
Installation Instructions
FL11651 R3 II FL11651 2 R3 Metal Roof Panel Detail -
signed.Ddf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 2 R3 032GulfLok 16 15-
32Plvwood NonHVHZ-signed odf
Created by Independent Third Party: Yes
11651.3
1" 24ga. Gulf Snap
1" Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes.
Impact Resistant: N/A
Design Pressure: +N/A/--131.OPS
Other: -67.3 psf @ 24" o.c: clip spacing: -131 psf @ 6" o.c.
clip spacing. Install per manufacturers details. For use in
HVHZ Zones.
Installation Instructions
FL11651 R3 II FL11651 3 R3 Metal Roof Panel Detail -
sioned.Ddf
Verified By: Dan Kuhn, RE. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 3 R3 1 24GulfSnaD 17 15-
32Plvwood HVHZ-signed.Ddf
Created by Independent Third Party: Yes .
11651.4 1" 24ga. VersaLoc
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-138.5PSF
Other: -71 psf @ 24" o.c. clip spacing. -138.5 psf @ 6" o.c.
clip spacing. Install per manufacturers details. For use in
HVHZ Zones.
11651.5 11" VersaLoc .032". Aluminum
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-101.0PSF
Other: -63.3 psf @ 24" o.c. clip spacing. -101.0 psf @ 6"
o.c. clip spacing. Install per manufacturers details. For use in
HVHZ Zones.
1" Versal-oc 24ga 16.5" Wide Roof Panel over 15/32" Plywood
Installation Instructions
FL11651 R3 II FL11651 4 R3 Metal Roof Panel Detail-
sinned.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 4 R3 24VersaLoc SR 16.5 IS-
32Plywood HVHZ-signed.Ddf
Created by Independent Third Party: Yes
1" Versal-oc min .032" Aluminum over 15/32" Plywood
Installation Instructions
FL11651 R3 II FL11651 5 R3 Metal Roof Panel Detail-
sinned.odf
Verified By: Dan Kuhn; P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 5 R3 lin 032VersaLoc
SR 16 15-32Plvwood HVHZ-signed.Ddf
Created by Independent Third Party: Yes
httns://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQvADgsQFc5K%2ffr... 10/8/2018
Florida Building
Code Online
Page 3 of 5
11651.6 1 1.5" 24ga. Gulf Snap
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116.OPSF
Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
o,c. clip spacing. -116.0 psf @ 6" o.c. clip spacing. Install per
manufacturers detals. For use in HVHZ Zones.
11651.7 1 1.5" 24ga. VersaLoc
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-123.5PSF
Other: -59.75 psf @ 24" o.c. clip spacing. -123.5 psf @ 12"
o.c. clip spacing. Install per manufacturers details. For use in
HVHZ Zones.
111651.8 1211 24ga. MegaLoc
Limits of Use
Approved for use in HVHZ: No
Approved for use'outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5PSF
Other: -71.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
o.c. clip spacing. Install per manufacturers details. Not for
use in HVHZ Zones.
11651.9 124 Ga. Gulf Lok
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
impact Resistant: N/A
Design Pressure: +N/A/-96.7PSF
Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -96.76
psf @ 5-1/8" o.c. fastener spacing.-121.75 psf @ 5-1/8"
fastener spacing. -161 psf @ 5-1/8" fastener. spacing. Install
per manufacturers details. Not for use in HVHZ Zones.
1.5" Gulf Snap 24ga. 16" Wide Roof Panel over 15/32"
Plywood
installation Instructions
FL11651 R3 II FW651 6 R3 Metal Roof Panel Detail-
sianed.odf.
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third. Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 6 R3 1.5 24Gu1fSnaD 16 15-
Created by Independent Third Party: Yes
IS' VersaLoc min 24ga. 16" wide Roof Panel over 15/32"
Plywood
Installation Instructions
FL11651 R3 II FL11651 7 R3 Metal Roof Panel Detail-
sianed.Ddf
Verified By: Dan Kuhn, P.E: 75519
Created by Independent Third Party: Yes
Evaluation Reports.
FL11651 R3 AE FL11651 7 R3 1.5 24VersaLoc 16 15-
32Plvwood HVHZ-sioned.odf
Created by Independent Third Party: Yes
Min 24 Ga. 2" MegaLoc 18" wide Roof Panel over 15/32"
Plywood
Installation Instructions
FL11651 R3 II FL11651 8.113 Metal Roof Panel Detail-
sianed.Ddf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 8 R3 24VersaLoc 18 15-
32Plvwood NonHVHZ-sianed.odf
Created by Independent Third Party: Yes
Min 24 Ga. Gulf Lok 16" Wide over 15/32" Plywood
Installation Instructions
FL11651 R3 II FL11651 9 R3 Metal Roof Panel Detail-
sioned.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 9 R3 24GuifLok 16 IS-
32Plvwood NonHVHZ-sianed.odf
Created by Independent Third Party: Yes
11651.10 24 Ga. Gulf Seam Min 24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood
Puriins over 15/32" Plywood
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-93.5PSF
Other: -93.5 psf @ 18" o.c. Install per manufacturers
details. Not for use in HVHZ Zones.
Installation Instructions
FL11651 R3 II FL11651 10 R3 Metal Roof Panel Detail-
sii ned.Ddf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 10 R3 24GulfSeam 16 1x4 15-
32Plvwood NonHVHZ-sioned.Ddf
Created by Independent Third Party: Yes
11651.11 124 Ga. Gulf Seam I Min 24 Ga-. Gulf eam, 1 d 4" Snap Lock, 18" Wide Roof
Panel over 5/32"
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5PSF
Other: -69.25 psf @.24" o.c. clip spacing. -108.5 psf @ 12"
o.c. clip spacing. Install per manufacturers details. Not for
use in HVHZ Zones.
11651.12 126 Ga. 5.V Crimp
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-156.SPSF
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @
6" o.c. fastener spacing. Install per manufacturers details. For
use in HVHZ Zones.
Installation Instructions
FL11651 R3 II FL11651 11 R3 Metal Roof Panel Detail-
sianed.Ddf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 11 R3 24GulfSeam 18 15-
32Plywood NDnHVHZ-sicined.pdf
Created by Independent Third Party: Yes
Min 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood
Installation Instructions
FL11651 R3 II FL11651 12 R3 Metal Roof Panel Detail-
sianed.Ddf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party:. Yes
Evaluation Reports
FL11651 R3 AE FL11651 12 R3 265vCrimo 15
httos://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgSQFc5K%2ffr... 10/8/2018
Florida Building Code -Online.
Page 4 of 5
_ I Created by Independent Third Party: Yes
26 Ga. 5V Crimp
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes.
Impact Resistant: N/A
Design Pressure: +N/A/-131.PSF
Other: -94.25 psf @ 16" o.c. fastener pattern. -131.0 psf @
16" o.c. fastener pattern. Install per manufacturers details.
Not for use in HVHZ Zones.
Installation Instructions
FL11651 R3 II FL11651 13 R3 Metal Roof Panel Detall-
sioned.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 13 R3 265vCrimo IS-
32Plvwood NonHVHZ-sioned.odf
Created by Independent Third Party: Yes
11651.14
26 Ga. 5V Crimp
Min 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over _
15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 II FL11651 14 R3 Metal Roof Panel Detail -
sianed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-156.5PSF
Created by Independent Third Party: Yes
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @
Evaluation Reports
6" o.c. fastener spacing. Install per manufacturers details. For
FL11651 R3 AE FL11651 14 R3 26SvCrimo 1x4 15-
32Plvwood NonHVHZ-sioned.odf
use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.15
26 Ga. Gulf Lok
Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R3 II FL11651 15 R3 Metal Roof Panel Detail -
sianed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-161.OPSF
Created by Independent Third Party: Yes
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75
Evaluation Reports
psf @ 5 3/16" spacing. -161.0 psf @ 5 3/16" o.c. fastener
FL11651 R3 AE FL11651 15 R3 26GulfLok 16 IS -
32Plvwood HVHZ-sioned.odf
spacing. Install per manufacturers details. For use in HVHZ
Zones.
1 Created by Independent Third Party: Yes
116.51.16
26 Ga. Gulf Lok
Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 II FL11651 16 R3 Metal Roof Panel Detail -
sianed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn; P.E. 75519
Design Pressure: +N/A/-63.5PSF
Created by Independent Third Party: Yes
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75
Evaluation Reports -
psf @ 5 3/16" fastener spacing. -161 psf @ 5 3/16" fastener
FL11651 R3 AE FL11651 16 R3 26Gulf _ok 16 IS -
32Plvwood NonHVHZ-sioned.odf
spacing. Install per manufacturers details. Not for use in
HVHZ Zones.
Created by Independent Third Party: Yes
11651.17 126 Ga. GuIfPBR
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-154.7PSF
Other: -59.25 psf @ 24" o.c. fastener pattern.-154.75 psf
@ 12" o.c. fastener pattern. Install per manufacturer details
Not for use in HVHZ
11651.18 126 Ga. GuIfPBR
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-151.7PSF
Other: -100.5 psf @ 24" o.c. fastener spacing.-151.75 psf
@ 12" fastener spacing. Install per manufacturer's details.
For use in HVHZ Zones
Min 26 Ga. Gulf PBR Roof Panel over 15/32" Plywood
Installation Instructions
F1_11651 R3 II FL11651 17 R3 Metal Roof Panel Detail-
sianed.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 17 R3 26GuIfPBR IS-
32Plywood NonHVHZ-sioned.odf
Created by Independent Third Party: Yes
Min 26 Ga. GuIfPBR Roof Panel over 1x4 Wood Purlins over
15/32" Plywood
Installation Instructions
FL11651 R3 II FL11651 18 R3 Metal Roof Panel Detail-
sioned.odf
Verified By: Dan Kuhn, P.E. 75519
Created'by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 18 R3 26GuIfPBR 1*4 15-
32Plvwood HVHZ-sianed.odf
Created by Independent Third Party: Yes
111651.19 126 Ga. GuIfPBR I Min 26 Ga. GulfPBR over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-154.7PSF
Other: -60.5 psf @ 24" o.c. fastener spacing.-154.75 psf @
Installation Instructions
FL11651 R3 II FL11651 19 R3 Metal Roof Panel Detail-
sioned.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 19 R3 26Gu1fPBR IS-
https:%/www.floridabuilding.orv-/pr/. r_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2fTr... 10/8/2018
Flonda Building Code Online , -
,, 1
12" o.c. fastener spacing. Install per manufacturer's details. 32PIVwood HVHZ-signed.odf
For use in HVHZ Zones. Created by Independent Third Party: Yes
11651.20 126 Ga. GuIfPBR
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHP Yes
Impact Resistant: N/A
Design Pressure: +N/A/-151.7PSF
Other: -94.25 psf @ 24" o.c. fastener spacing.-151.75 psf
@ 12" fastener spacing. Install per manufacturer's details.
Not for use in HVHZ Zones
Go to Page =
Page 5 of 5
Min 26 Ga. GuIfPBR over 1x4 Wood Purlins over 15/32"
Plywood
Installation Instructions
FL11651 R3 II FL11651 20 R3 Metal Roof Panel Detall-
sioned.Dd
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 20 R3 26GuIfPBR 1x4 15-
32PIVwood NonHVHZ-signed.Ddf'
Created by Independent Third Party: Yes
Back NeM
010. Page 1/ 2 d 10
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact a50.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which an be made available to the public To determine If you are a licensee under Chapter 455, F.S., please
click here .
Product Approval Accepts:
RR M
CreditLard
- Sate y
httpg://www.floridabuilding.org/pr/pr app_dtl.aspx?paraxn=wGEVXQwtDgsQFc5K%2ffr... 10/8/2018