HomeMy WebLinkAboutEVALUATION REPORT - UNDERLAYMENTNEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
REPORTEVALUATION
Owens Corning Roofing and Asphalt, LLC Evaluation Report 140510.02.12-114
One:OWenS Corning Parkway FL15216-114
Toledo, OH 43659 SCANNED Date of Issuance: 02/17/2012
(740) 321-6345 py Revision 4: 04/19/2018
Lucae OO1ui�fy
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. !for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: RhinoRoof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to
the pi
I roduct(s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This valuation Report consists of pages 1 through 3.
Prepared by:
`,�t yea?.. "'••,,.
Robert J.M. Nieminen, P.E. The facsimilesealappearing was authorized by Robert
Florida Registration No. 59166, Florida DCA ANE1983
�1s°r�� �r+`Nieminen, P.E. on 04/19/2018. This does not serve as an
..��.,,,;,;,,,� '
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ONEMOletc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: U nderlayment
Compliance Statement: RhinoRoof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC, has
demonstrated compliance with the following sections of the 6u' Edition (2017) Florida Building Code through testing
in accordance with applicable sections of the following Standards. Compliance is subject to the Installation
Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Properties Standard Year
1507.1.1, R905.1.1 Exception Unrolling, Breaking Strength, Pliability ASTM D226 2009
1507.1.1, R905.1.1 Exception Tear Strength ASTM D1970 2015
TAS 110 Pull -through resistance TAS 117(B) 1995
kntitlf
ITS(TST1509)
ITS(TST1509)
ITS(TST1509)
PRI (TST5878)
PRI(TST5878)
ITS (QUA1673)
Examination
Physical Properties
Physical Properties
Physical Properties.
ASTM D1970; Tear strength
TAS 117(B); Pull -through
Quality Control
Reference
100539395COQ-006
100539395C04002
100539395COQ-006
OCF-330-02-02
OCF-422-02-01
Service Confirmation
Date
10/27/2011
10/27/2011
03/14/2014
10/03/2017
04/03/2018
09/30/2017
4.1 ` RhinoRoof U20 is a multilayered polymer woven coated synthetic roof underlayment available in 42-inch wide rolls,
and can be produced in various other sizes; meets FBC 1507.1.1 & R905.1.1 (Exception).
5.1 This is a building code evaluation. Neither MEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 I This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory or test
report from accredited testing agency for fire ratings of this product.
5.4 RhinoRoof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
5.6 Exposure Limitations:
RhinoRoof U20 shall not be left exposed for longer than 30-days after installation.
NEMOiETC, LLC Evaluation Report 140510.02.12-114
Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL15216-R4
RhinoRoof Underlayments Revision 4: 04/19/2018
Page 2 of 4
NEMO I etc.
RhinoRoof Underlayments shall be installed in accordance with Owens Corning Roofing and Asphalt, LLC
published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted
below.
6.2' Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application.
6.3 RhinoRoof U20:
6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table
1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, taking into account the wider sheet -
width.
6.312 Fasteners:
For exposure < 24 hours, corrosion resistant fasteners may be 1-inch roofing nails with a 3/8-inch diameter head,
minimum 1-inch diameter plastic or metal cap nails or FBC HVHZ nails & 1-5/8" diameter tin caps (with the rough
edge facing up). The use of staples is prohibited.
For exposure > 24 hours up to maximum 30 days, corrosion resistant fasteners shall be minimum 1-inch diameter
plastic or metal cap nails or FBC HVHZ nails & 1-5/8" diameter tin caps (with the rough edge facing up). The use
of staples is prohibited.
6.3.2.1 Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "...except metal cap nails
shall be required where the ultimate design wind speed, V„ it, equals or exceeds 150 mph."
Owens Corning Roofing and Asphalt, LLC has furnished data to permit the use of 1-inch diameter plastic cap nails
in lieu of metal cap nails for these applications, when the RhinoRoof U20 underlayment is installed beneath
mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1 or R905.1.1.
6.3.3 Single Laver: Roof Slope > 4:12:
i
End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. Refer to
Owens Corning Roofing and Asphalt, LLC recommendations for alternate lap configurations and/or the use of
sealant under certain conditions.
For exposure < 24 hours, use of every -other fastening location printed on the surface is acceptable. For exposure
> 24 hours up to maximum 30-days, use of every fastening location printed on the surface is required.
When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily
attached pending attachment of the battens on the same day. Battens shall not be positioned over cap nails. If
this occurs, remove the cap nail and patch the hole in accordance with Owens Corning Roofing and Asphalt, LLC
published instructions.
6.3.4 Double Laver; 2:12 < Roof Slope < 4:12:
End (vertical) laps shall be minimum 12-inches and side (horizontal) laps shall be minimum half -sheet -width plus
1-inch.
Double layer application; begin by fastening a half -width plus 1-inch starter strip along the eaves. Place a full -
width sheet over the starter, completely overlapping the starter course. Continue as noted in 6.3.3, but
maintaining minimum half -width plus 1-inch side (horizontal) laps, resulting in a double -layer application.
NEMOI ETC, LLC Evaluation Report 140510.02.12-114
Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL35216-114
RhinoRoof Underlayments Revision 4: 04/19/2018
Page 3 of 4
ONEMO,jetc.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation
of this product.
Qingdao, China
Intertek Testing Services NA Inc. — QUA1673; (608) 836-4400
- END OF EVALUATION REPORT -
NEMO TC, LLC Evaluation Report 140510.02.12-114
Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.35216-114
RhinoRoof Underlayments Revision 4: 04/19/2018
Page 4 of 4