HomeMy WebLinkAboutPRODUCT APPROVAL - METAL ROOFINGGulfRibTM Roof Panel over 15132" PjyjWFiCE
COP
Florida Product Approval #11651.22 R3
WFIwilding Code 2017
Per Rule 61 G20-3 THESE PLANS AND ALL PROPOSED WORK
Method: 1 —D ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
Category: Roofing COMPLY WITH ALL APPLICABLE CODES.
Subcategory: Metal Roofing
Compliance Method: 61 G20-3.005(1)(d)
NON HVHZ
CONCEALED FASTENERS OR ATrACHMENVTS
CONTRACTOR OIRIUTY RE ORI? E
Product Manufacturer:
Gulf Coast Supply & Manufacturing, LLC.
14429 SW 2nd Place, Suite G30 `'' �''
Newberry, FL 32669 ���oPN� r. E S,'
Engineer Evaluator:
Dan Kuhn, P.E. #75519
Florida Evaluation ANE ID: 10743
Validator:
Locke Bowden, P.E. #49704
9450 Alysbury Place
Montgomery, AL 36117
Contents:
Evaluation Report Pages 1 — 5
* : No. 7551.9
i
STATE OF
O R I D P• •���•�
S; l'NA L% � �10/05/202 j
Product Evaluation Report
GULF COAST SUPPLY & MANUFACTURING, LLC. SCANNED Y
St Lucie County
26 Ga.
-0f'60
2u ni u.2�
;T. LUCIE COUNTY BUILDING D
EVIEWED FOR
ICOMPLIANC
G\/TCIA/CI"1 Qv 1 /. /I
LANS AND PERMIT MUST BE KEPT O 30B
ITE OR NO INSPECTION(-S WILL MADE
I �
1651.22 R3 • OCTOBER 5, 2017
•
Gulf���
SUPPLY & MANUFACTURING
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2.
Product Description: GulfRibTM' 3/a" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage,
through fastened roof panel over minimum 15/32" Plywood Decking. Non
Structural application.
Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to
Florida Building Code 2017 Section 1507.4.3.
Paint Finish Optional
Yield Strength: Min. 80.Oksi
Corrosion Resistance: Panel Material shall comply with Florida Building
Code 2017, Section 1507.4.3.
I Panel Dimension(s):
I
Panel Fastener:
,Substrate Description
'Design Uplift Pressures:
I
FL# 11651.22 R3 0 OCTOBER 5, 2017
Thickness:
0.018" Minimum
Width:
36" Coverage
Rib Height:
3/a" Major Rib at 9" O.C.
#9-15x1.5" HWH with sealing washing or approved equal
1/4" minimum penetration through plywood.
Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4
Minimum 15/32" thick, APA Rated plywood ov uppo at maximum 24" O.C.
Design of plywood and plywood supports re outside th scope of this
evaluation. Must be designed in accord ce w/ Florida Bui ding Code 2017.
Table "A"
f
Maximum Tot I�Uplift �esls gn Press ure
69 25 6w
�159 25 psf
Fastener Pattern
9"-9"-9"-9"
6.5"-2.5"-6.5"-
2.5"6.5"-2.5"-6.5"
'xaiG3 'eK
wy `` may-eX,6ttern S;acin
Fastenpg� , +
{f
24 O C;c
f h
1=2 o�c � :
Design Pressure includes a Safety Fa
or = 2.0.
Code Compliance:
The product described herein has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2.
Evaluation Report Scope:
The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3.
Performance Standards:
The product described herein has demonstrated compliance with:
• UL 580-06 - Test for Uplift Resistance of Roof Assemblies
• UL 1897-12 - Uplift Test for Roof Covering Systems.
�eference Data:
1. UL 580-94 / 1897-98 Uplift Test
Force Engineering & Testing, Inc. (FBC Organization # TST 5328)
Report No. 117-0062T 07A, B, Dated 02/19/2007
2. Certificate of Independence
By Dan Kuhn, P.E. (FL# 75519) @ Kuhn Engineering, LLC
(FBC Organization # ANE ID: 10743)
Test Standard Equivalence:
1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test
standard.
Quality Assurance Entity:
The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61 G20-3.005(3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity.
(Minimum Slope Range:
Minimum Slope shall comply with Florida Building Code 2017, including
Section 1507.4.2 and in accordance with Manufacturers recommendations. For
slopes less than 3:12, lap sealant must be used in the panel side laps.
Installation:
Install per Manufacturer's recommended details.
;Underlayment:
Shall comply with Florida Building Code 2017 section 1507.1.1.
FL# 11651.22 R3 • OCTOBER 5, 2017
Gulf
SUPPLY & MANUFACTURING
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
i
Shear Diaphragm: Shear Diaphragm values are outside the scope of this report.
Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must
at a minimum meet those listed for the applicable wind zone. For all roofs outside
the parameters listed on the load table, design wind loads shall be determined
for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10
using allowable stress design. The maximum fastener spacing listed herein shall
not be exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this
product in High Velocity Hurricane Zone.
I
Gulf
SUPPLY & MANUFACTURING
ENGINEER LOAD TABLE: 26 Ga. GulfRibTlM Panel over 15/32" Plywood
Buildings having a Roof Mean Height 5 ;20 0 '; Roof Slope 2 '/12" - 12' /12,' Gable or Hip Roof, °Wind Speeds 120
180ri7ph, Exposure C,. Risk Category II; .EnclosedBuilding based;on Flonda'Bullding,Code a2017 r . .
120
130
140
150
160
170
180
WIIND
FASTENER
SUBSTRATE
SPEED
(MIN. 1/4"
Penetration)
(MIN. 15/32")
ON CENTER
ON CENTER
ON CENTER
ON CENTER
ON CENTER
ON CENTER'
ON CENTER
i
SPACING
SPACING
SPACING
SPACING
SPACING
SPACING
SPACING
ZONE 1
#915X1 5"�,
PlyvvOOd �.
24', TYPE 1
24'iTYPEz1t
24", TYPE 1
'24" TYPE,1
24', TYPE1,
' 24"; TYPE 1`'
24", TYPE1
ZONE 12
#9-15x1.5"
Plywood
24", TYPE 1
24", TYPE 1
24", TYPE 1
24", TYPE 1
24", TYPE 1
24", TYPE 1
24", TYPE 2
ZOrNE 3
#9 15x1 5'
Plywood
44 , TYPE 1,
24*,TYPE 1
'24 °TYPE 1{
12 TYPE 2
12' TYPE 2
12 '-TYPE 2
12 TYPE 2
1.) PANEL DESCRIPTION: GULFRIBTM, MIN. 26 GA., GRADE 80, 36"COVERAGE, 3/4" TALL.
2.) PANEL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL
3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: 69.25 PSF @ 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 159.25
PSF @ 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING.
4.) PLYWOOD DECKING: MIN. 15/32" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017.
5.) ROOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS.
6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING
CODE Z017.
LUIYC L ZONE 3- T_..I
'------------------
\\ \ RIDGE
ZONE \\\\\I
/-------------------�
Note: Dimension (a) is defined as 10% of the minimum width of the building or
40% of the mean height of the roof, whichever is smaller, however, (a) cannot be
L-�a less than either 4% of the minimum width of the building or 3 feet.
TYPE 1 FASTENER PATTERN
ZONE 2 GABLE ROOF]
-- —-----------------i_:::ja
I I
I, I
RIDGE j
--------------------� a
--- ---------------------I a
I I
ZONE 1
I I
+----------------------+
3
2017
nil
�9"� Panel
Cont. Tape Seal for use on Slopes less than 3:12
(1) #9-15 x 1-1/21 w/Sealer Washer @ 24° O.C. Max.
TYPE 2 FASTENER PATTERN
6.5"-- 2.5" if 6.5"—fi2.511 -r-6.5"—i 2.5"
Cont: Tape Seal for use on Slopes less than
#9-15 x 1.1/2" w/Sealer Washer @ 12" O.C. Max.