Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL - MODIFIED BITUMENI Florida Building Code Oniine s r ._tc.� . BCIS Home Log In User Registration Hot Topics Submit Surcharge. Slats Facts )tad Product Approval } USER: Public User Product Ao proval>Menu > Product orADplica lion Search > Agplica [ion List s AppQeation DetaB FL1654-R22 gka,� FL* Revision �- Application Type Code Version Appr Application Status Approved Comments Archived 7; Publications FBC Staff BCIS Site Map ' Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1378 Ext 242 alender@p6lyglass.com Authorized Signature Ariel Lender alender@polyglass.com Technical Representative Maury Alpert Address/Phone/Email Jill W. Newport Center Drive Deerfield Beach, FL 33442 (912) 429-8610 MAlpert@polyglass. com Quality Assurance Representative Ariel Lender Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1230 ALender@polyglass. com Category Roofing Subcategory Modified Bitumen Woof System Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Evaluation Report from a Florida Registered Architect or a Licens Professional Engineer Evaluation Report - Hardcopy Received Robert Nierrinen PE-59166 UL LLC 10/06/2018 John W. Knezevich, PE Validation Checldist - Hardcopy Received FL1654 R22 "COI 201761 COI Nieminen.pd Referenced Standard and Year (of Standard) Standard ASTM.D6162 ASTM D6163. ASTM D6164 ASTM D6222 Year 2008 2008 2011 2011 .org/pr/pr_app dN.asp�Clparerr�wGEVXQwtD4WQu2W%o2bnFgUPJLpvkpKxAhdiq%CZfSdIP/o2bno/92tYV1 x5rxA%3d%3d 1/2 ` Florida Building Code Online .514/2018 . 2009 AST M D6509 FM 4470 2012 FM 4474 2011 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending F13C Approval Date Approved Method 1 Option D 09/14/2017 09/15/2017 09/.22/2017 12/12/2017 FL # Model, Number or Name 1654.1 Polyglass SSS and, APP Modified Bitumen Roof Systems Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-622.5 other: 1.) The design pressure in this application relates to one particular assembly over concrete deck. Refer to the ER Appendix for other systems and deck types. 2.) Refer to ER, Section 5 for other Limits of Use. Description SBS and APP modified bitumen roof systems, Installation Instructions F1 1654 R22 H 2017 09 FINAL Al M POLYGLASS MO R22�pdf Verified By: Robert Nieminen PE-59166 Created by Independent Thins Party: Yes Evaluation Reports :FL1654 R22 AE 2017 09 'FINAL 'ER POLYGLASS 'MODE R22. pdf Created by Independent Third Party: Yes Contact Us .: 2601 Blair stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The state of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: A�xessibillly Statement :: Refund Under Florida law, email addresses are public records. If you do not vent your a=mall address released in response to a public -records reques electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact850.487.139 Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter455, F.S. must provide the Department with an they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record'. If yo supply a personal address, please provide the Department with n email address please dick here ad made • available to the public To determine if yo under apter Product Approval Aeeepts: =r =--"- a—�R E{_ Credit- / Saf !i!?4 UJ7L'6'h31•'TItIC�' ng.org/pripr_app-0.aspx?m= parawGEVXQwtDgWqu2W%2bnFgUpv4wkpKxAhdKjvczfsdie/,2bw/o2fY411F:ar)A%3d%3d 2(2 TRINITY, ERD APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE - Page Table Deck Application Type Description 5 SA Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 5 9 Wood New or Reroof (Tear -Off). A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 1B-1 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10-11 1B 2 New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 11 1C Wood Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 12-13 1D New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 14-15 3E Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 16-21 1F-1 Wood. New, Reroof (Tear -Off) or Recover . E Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 19-2 1F-2 Wood' Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 2 iG Steel Structural concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 22 24 2A ZB or Steel or Structural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 25-28 Steel or Structural concrete New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 29-31 2C 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded insulation, Bonded Roof Cover 32-40 40 38 Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 41-42 4A LWIC New or Reroof (Tear -,Off) A-1 Bonded insulation, Bonded Roof Cover New or Reroof (Tear -Off)' A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 43 4B LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 44-46 4C LWIC ..,� New or Reroof (Tear-Offl A-1 Bonded Insulation, Bonded Roof Cover 47 _SC CVVI­ CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 49 51) CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 49 SE Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 50.52 6A Gypsum Reroof (fear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 52 68 Gypsum Y Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 53 6C Gypsum Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 53 6D Gypsum Recover A-1 Bonded Insulation, Bonded Roof Cover 54.58 7A Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 58 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented,through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0:75-inch penetration. ➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. Structural concrete: Minimum 1-inch embedment into pilot'hole in accordance with fastener manufacturer's published Installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the QA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, forfoam plastic, FBC Chapter 26, when installed with the roof cover. Exterior Research and Design, LLC, d/b/a Trinity IERD Evaluation Report P9290.02.08-1120 for FL1654-1122 _ __ _Certificate of AuthorizatloR#9503 0 EDITION (2017) FBC NON-HVHZ EVALUATION _ Revision 20: 09112/2017 Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems, (570) 384=1230 — Appendixl-Page 1'of58 r' V TRINITY I ERD Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members -shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016). Unless otherwise noted, insulation adhesive application rates areas follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Hot asphalt (HA): Full coverage at 25-301bs/square. ➢ Dow INSTA STIK Quik Set Insulation Adhesive PIS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ Millennium One Step F.oamable Adhesive (M-OSFA); Continuous 0.25 to 0.5-Inch wide ribbons, 12-inch o.c. ➢ Millennium PG-1 Pump Grade Adhesive (M-PG1): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ➢ OMG OlyBond 500 (08500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShat). Note: OlyBond Green may be used where OlyBond 500 is referenced. OlyBond Classic (OB Classic): Full coverage at 1 gal/square. D ICP Adhesive & Sealants CR-20: Continuous 2.573.5-inch wide ribbons, 12-Inch o.c. ➢ 'Note: When multiple loyers(s) of insulation and/or coverboard are Installed in ribbon -applied adhesive, board joints shall be staggered. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. r. Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. in no case shall these values be used to'increase' the MDP listings in the tables; rather If MDP listing below meets or exceeds that listed fora particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick) ➢ Millennium PG-1 Pump Grade Adhesive (M-PG1): MDP -157.5 psf (Min.0.5-inch thick) ➢ OMG OlyBond 500 (08500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) ➢ OMG OlyBond 500 (08500): MOP -187.5 psf (Min.0.5-inch thick ISO 95+GL) ➢ OMG OlyBond 500 (OB500): MDP -313.0 psf (Min. 0,5-inch thick ENRGY 3) OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam 11) ➢ ICP Adhesives & Sealants CR-20: MDP -117.5 psf (Min.1.0-inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4x4ft. 9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are AN51/SPRI WDl, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with AN51/SPRI FX-1 orTesting Application Standard TAS 105. 12. ,For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 11 For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. 14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 11317.4.1, Point 1. Exterior Research.and Design, U.C. d/b/a Trinity(ERD Evaluation Report P9290.02.08-R20 for FL1654-R22 e EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017 Certificate of Authorization #9503 Polyglass Modified Bitumen Roof Systems; (570) 384 i?30 P Appendix of Prepared by: Robert Nieminen, PE-59166 Entity ERD (TST11294) ERD (TST6049) ERD (TST6049) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) Miami -Dade (CER3592) Miami -Dade (CER1592) UL LLC (QUA9625) 4. PRODUCT DESCRIPTION: Examination FM 4474/UL1897/TAS 114 FM 4474/UL1897 FM 4474/TAS 114 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 Physical Properties Physical Properties Physical Properties Physical Properties TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 HVHZ Compliance Proposal for Review Quality Control Reference PLYG-CTL13945.05.17-3 PLYG-SC13945.05.17 PLYGSC15760.09.17 2W7A7.AM OD3A3.AM 2DOAO.AM 2D5A9.AM 3006646 3001334 3001334 3000857 3004091 3006115 3012321 3014692 3014751 3007170 3019317 30.20703 3018332 3023368 3024594 3023458 3030668 3032172 3049631 3057029 PUSA-062-02-01 PUSA=061-02-02 PUSA-064-02-02 PUSA-062-02-02 PUSA-188-02-01 PUSA-188-02-02 PUSA-188-02-03 PUSA-202-02-01 PUSA-202-02-02 Various WAS 10-0823 Service Confirmation, R14571 a TRINITY , ER® Date, 05/30/2017 05/30/2017 09/11/2017 08/04/1994 04/04/1997 12/23/1998 06/22/1999 01/04/2000 01/25/2000 02/15/2000 01/12/2000 01/12/2000 65/02/2001 07/29/2002 08/05/2003 08/27/2003 01/13/2004 06/30/2004 07/30/2004 01/31/2006 03/20/2006 05/23/2006 07/18/2006 09/12/2007 06/12/2009 04/21/2014 02/02/2017 12/04/2007' 01/28/2008 02/27/2008 12/04/2008 02/08/2017 02/08/2017 02/08/2017 05/17/2017 05/17/2017 Various 10/12/2010 Exp.10/06/2018 This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass mh�an6e make u- the suhiect systems. TABLE 1: ROLL -GOODS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS Type Product Speclfiwtion Reference Grade Type Base Sheets Polyglass G2 Base ASTM D4601 N/A II Polynex SA Base Polyglass APP Base ASTM D4601 ASTM D6509 N/A N/A II N/A Exterior Research and Design, LLC. Certificate of Autharization #9503 Evaluation Report P929D.02.08-R20 EDITION '(2017) FBc NON-HVHZ EVALUATION F,L1654-R22 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20:09/12/2017 Page 3 of 6 k TRINITY, ERD TABLE 1(CONTINUED) RCILL'GOODS,FOR POLYGLASS MODIFIED BITUMEN :ROOF,SYSTEMS Type Product Specification - Reference G rade Type SB5 Membranes Polygiass HT Base 650 ASTM D6162 S III _. Elastobase ASTM D6163 S I Elastoflex V ASTM D6163 S I Elastoflex SA V Base ASTM D6163, Table 2 S I �,Elastofl0 V 1FRBase' ASTM D6163, Table 2 S I Elastoflex 5A V`Plus " " . ASTM D6163 _ S I Elastoflex SA V Plus FR ASTM D6163 S I Elastobase Poly ASTM D6164 S I Elastoflex S6 ASTM D6164 S " Elastoflex S6 Type II, ASTM D6164 5 II Elastoflex VG ASTM D6163 G I Elastoflex VG FR ASTM D6163 G I ,. SBS Membranes Elastoflex 56 G _ _ _ __ ASTM D6164 G Elastoflex S6 G FR ASTM D6164 G I Polvfresko G SBS (sand orpoly-film backed) ASTM D6164 G I Polyfresko G SBS FR (sand or poly -film backed) ASTM D6164 G I_ Elastoshield TS G ASTM D6164 G I Elastoshleld TS G FR ASTM D6164 G I Elastoflex SA P ASTM D6164 G I Elastoflex SA P FR ASTM D6164 G I , Polyreflect ASTM D6164 S I APP Membranes Polyflex ASTM D6222 S I Polyflex G ASTM D6222 G I Polyflex G FR ASTM D6222 G I Polyfresko G 'ASTM D6222 G I Polyfresko G FR ASTM D6222 G 1 Pol bond ASTM D6222 S I Polybond G ASTM D6222 G I i;P,61 Fl 0 P, .:. ASTM D6222 G Polyflex SA P FR ASTM D6222 G I Polyfresko G SA ASTM D6222. G I Polykool ASTM D6222 S I S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any, way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation. Report is not for use in FBC HVHZ jurisdictions. 5.3 Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior "in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. Exterioi Research and Design, U.C. Evaluation Report P9290.02.08-R20 Certificate of Authorization t/9503 6?"EDITION (2017)FBC `NON-HVHZ.EVALUATION FL1654=R22 Polyglass Modified Bitumen Roof. Systems; (570) 384.1230 Revision20.09/12/2017 Page 4 of 6 ""i TRINITYERA TABLE 1F-2: WOOD DECKS- NEW CONSTRUCTION, REROOF(TEAR-OFF) oR RECOvER SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System Base Sheet I Roof cover (Note is) MOP No. Deck (Note 1) Type Fasten Attach Base Ply Cap iPsf) SELF -ADHERING BASE PLY:•: Min.19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 12-in6 o.c. In 4-inch lap and 12-inch o.c. in two SSS-SA SBS-SA, APP-SA, SBS- -52.5` W 136 inch plywood (poly -film top) or Trufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows TA, APP-TA Min.19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 12-inch o.c. in 4-inch lap and 12-inch o.c. in two Polyflex SA Base APP-TA -52.5` W 137 inch plywood (poly -film top) or Trufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows W-138 Min.19/32- Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip #12 12-Inch o.c. In 4-Inch lap and 12-inch o.c. in two SBS-SA SBS-SA, APP-SA, SBS- 60.0` ,inch plywood (poly -film -top) (2), equally spaced, staggered center rows TA, APP-TA W-139 Min.19/32- Elastobase, Elastobase P OMG flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. In 4-inch lap and 12-1nch o.c. in two Polyflex SA Base APP-TA -Isov inch plywood (poly -film top) (2), equally spaced, staggered center rows TABLE 16: WOOD DECKS —NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System Deck (Note i) Primer Roof Cover (Note 15) MDP (psf) Joint Treatment Base Ply Ply Cap Ply No. 10.f140f� Nane _? None1 t ��rr , c 1 ti,� t'r F 5855A -_ (OptioRal)'SBS-SA SBS- an:' -SBS-SA APP- A;S$S 9D0 �a ys' inehph/NoodN. €._ r __. �. £ �z� r ,we , fi. N' •ETA; APP-iA fA AP2 LA» �j_ y W-141 Min.15/32- (Optional) PG100 None Polyflex SA Base (Optional)APP-TA APP-TA 90.0 inch plywood W-142 Min.15/32- PG100 None SBS-SA (Optional) SBS-SA, SBS- SBS-SA,APP-SA,SBS- 97.5 inch plywood TA, APP-TA TA, APP-TA ?ulin.15/32- Plywood joints arecovered with 4-inch wide strips of Elastoflex SA V Plus, rolled Into Elastoflex SA V Base or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- .97 5 W-143 inch plywood (Optional) PG100 place to create continuous bond. Elastoflex SA V FR.Base TA, APP-TA TA, APP TA W 144 Min.15/32- WB-3000 None SBS-SA (Optional) SBS-SA, APP-SA, SBS- _105.0 inch plywood TA, APP-TA MIn.15/32- Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled Into Elastoflex SA V Plus or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- W-145 inch plywood (Optional) BG300 place to create continuous bond. I Elastoflex SA V Plus FR TA, APP:TA TA, APP-TA -135.0 W-146 Min.15/32- (Optional) PG100 Plywood joints.are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled Into Polyflex SA Base (Optional) APP-TA APP TA -135.0 inch plywood place to create continuous bond. Exterior Research and Design, LLC. d/b/a Trinity ( ERD Evaluation Report P9290.02.08-920 for Fu654,RZ2 Certificate of Authorization N9503 - _ _ _ 6r" EDITION (2017) FBC NON-HVHZ EVALUATION _ _ Revision 20: 09/12/2017 Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems, (570) 384-1230 Appendix 1, Page 21 of 58