ENERGY EFFICIENCY CODE
ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge F1aCom v1.22 FORM 40OA-2001 Whole Building Performance Method for Commercial Buildings Jurisdiction: PORT ST LUCIE, ST LUCIE COUNTY, FL (661200) Short Desc: BH-NSCC Project: NORTH SIDE CHRISTIAN CHURCH Owner: SCANNE i Address: 3100 ST. LUCIE BLVD. BY City: FORT PIERCE, 82 LucCile C A State: FL PermitNo: '63'� 0 Zip: 0 Storeys: 1 ILE Type: Assembly GrossArea: 5847 Class: New Finished building Net Area: 5847 Max Tonnage: 10 (if different, write in) Compliance Summary Component Gross Energy Use Other Envelope Requirements - A LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? Design Criteria Result 94.96 100.00 PASSES PASSES PASSES PASSES PASSES PASSES PASSES PASSES Yes/No/NA IMPORTANT NOTE: An input report Print -Out from EnergyGauge FlaCom of this design building must be submitted along with this Compliance Report. 911105 EnergyGauge F1aCom FLCCSB v1.22 1 ' COMPLIANCE CERTIFICATION: I hereby certify that the plans and Review of the plans and specifications covered by this specifications covered by this calculation are calculation indicates compliance with the Florida Energy in compliance with the Florida Energy Code. Before construction is completed, this building will be Efficiency Code. inspected for compliance in accordance with Section 553.908, F.S. PREPARED BY: BUILDING OFFICIAL: / DATE: �J r DATE: I hereby certify that this building is in compliance Energy Efficiency Code. WALTER KARPINIA PE46635 with the Florida 6038 LINT©N ST. OWNER AGENT: JUPITEK FL 33463 DATE: (501) 262-7648 If required by Florida law, I hereby certify (*) that the system design is in REGISTRATION compliance with the Florida Energy Code. No. ARCHITECT: ELECTRICAL SYSTEM DESIGNER: LIGHTING SYSTEM DESIGNER: MECHANICAL SYSTEM DESIGNER: PLUMBING SYSTEM DESIGNER: (*) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. 9/1/05 EnergyGauge FlaCom FLCCSB v1.22 2 ` I Project: BH-NSCC Title: NORTH SIDE CHRISTIAN CHURCH _ Type: Assembly ' Location: PORT ST LUCIE, ST LUCIE COUNTY, FL (661200) (WEA File: DAYTONABEACH.T Whole Building Compliance • Design Reference Total 94.96 100.00 ELECTRICITY 94.96 100.00 AREA LIGHTS 19.51 19.67 MISC EQUIPMT 1.96 1.96 PUMPS & MISC 0.05 0.05 SPACE COOL 54.21 59.08 VENT FANS 19.24 19.24 Credits & Penalties (if any): Modified Points: = 94.97 PASSES Project: BH-NSCC Title: NORTH SIDE CHRISTIAN CHURCH Type: Assembly Location: PORT ST LUCIE, ST LUCIE COUNTY, FL (661200) (WEA File: DAYTONABEACH.T Other Envelope Requirements Item Zone Description Design Limit Meet Req. ROOF 1 ZONE 1 Exterior Roof - Max Uo Limit 0.03 0.09 Yes ROOF 2 ZONE 2 Exterior Roof - Max Uo Limit 0.03 0.09 Yes Meets Other Envelope Requirements 9/1/05 EnergyGauge F1aCom FLCCSB v1.22 3 Project: BH-NSCC Title: NORTH SIDE CHRISTIAN CHURCH Type: Assembly Location: PORT ST LUCIE, ST LUCIE COUNTY, FL (661200) (WEA File:.DAYTONABEACH.T External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) Ext Light 1 Exit (with or without Canopy) 25.00 100.0 2,500 2,500 Design: 2500 (W) PASSES Allowance: 2500 (W) Project: BH-NSCC Title: NORTH SIDE CHRISTIAN CHURCH Type: Assembly Location: PORT ST LUCIE, ST LUCIE COUNTY, FL (661200) (WEA File: DAYTONABEACH.T Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- ID (sq.ft) Tasks CP CP ance ZONE 1 21 Lobby (General) - Reception and 2,923 3 4 4 PASSES Waiting ZONE 2 21 Lobby (General) - Reception and 2,924 1 2 2 PASSES Waiting PASSES 9/1/05 EnergyGauge F1aCom FLCCSB v1.22 4 Project: BH-NSCC Title: NORTH SIDE CHRISTIAN CHURCH Type: Assembly Location: PORT ST LUCIE, ST LUCIE COUNTY, FL (661200) (WEA File: DAYTONABEACH.T System Report Compliance ZONE 1 System 1 Constant Volume Packaged No. of Units Multizone System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled 65000 to 135000 10.00 8.90 9.00 8.30 PASSES Btu/h Cooling Capacity Air Handling Air Handler (Supply) - 0.80 0.80 PASSES System -Supply Constant Volume ZONE 2 System 2 Constant Volume Packaged No. of Units Multizone System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled 65000 to 135000 10.00 8.90 9.00 8.30 PASSES Btu/h Cooling Capacity Air Handling Air Handler (Supply) - 0.80 0.80 PASSES System -Supply Constant Volume PASSES Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None 19/l/05 EnergyGauge FlaCom FLCCSB v1.22 5 Project: BH-NSCC Title: NORTH SIDE CHRISTIAN CHURCH Type: Assembly Location: PORT ST LUCIE, ST LUCIE COUNTY, FL (661200) (WEA File: DAYTONABEACH.T Water Heater Compliance Design Min Design Max Comp Description Type Category Eff Eff Loss Loss liance Water Heater. I Storage Water Heater - <=120 [gal] & <= 0.88 0.88 PASSES Electric 12 [kW] PASSES Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] .SF.F] None EnergyGauge F1aCom FLCCSB v1.22 6 Project: BH-NSCC Title: NORTH SIDE CHRISTIAN CHURCH Type: Assembly Location: PORT ST LUCIE, ST LU Category . Infltration System Ventilation ADS T&B Electrical Motors Lighting O&M Roof/Ceil Report Other Required Compliance Section Requirement (write N/A in bog if not applicable) 406.1 Infiltration Criteria have been met 407.1 HVAC Load sizing has been performed 409.1 Ventilation criteria have been met 410.1 Duct sizing and Design have been performed 410.1 Testing and Balancing will be performed 413.1 Metering criteria have been met 414.1 Motor efficiency criteria have been met 415.1 Lighting criteria have been met 102.1 Operation/maintenance manual will be provided to owner 404.1 R-19 for Roof Deck with supply plenums beneath it 101 Input Report Print -Out from EnergyGauge FlaCom attached? EnergyGauge F1aCom FLCCSB v1.22 Check 7 COMMERCIAL LOAD CALCULATIONS Air Conditioning Contrectors'of America (ROOM, ZQ1 E or BLOCK LOAD) 1712 New Hlimpshlre Avenue, NW Washington, DC 20009 PHONE 202' • 483 0370 rM rvc - z.74 4/Yr rVKM rd - l For. Name OEM Phone b Stag 21p fay eontrautar, Phone 1. DESIGN CONDITIONS (COOLING) (Time of Day.1+l} --4 .(Deily FIZAgo, a)Inside dt) 4,67 RH56 _ b) Outside db • wbGra1M j � OutalQe db 0 3 p•m• j J (•) minus time of day correctlons�(•) minus Insldadrybulb s _L_lILT,D. 2. SOLAR RADIATION HEAT GAIN THROUGH GLASS. COOLING LOAD Shading and/or Exposure sq. Ft. Solar Factor Glass Factor X:::��::::x Sensible Metes ::�::: X. 3. TRANSMISSION GAINS . Equlvalsnt`or Exposure Sq. Ft. U Factor Tempbdiff Qlnae j�'/ 4 n ; ...... .........X'..... X .... .... _ \Nall• C�: � � /./.... � :�:.:: .�.....:X ::. ': : X : .:::: ..., .... : ..X............ x ,.,• „• �,j-t • . . . /j.0 ....•X / X a Doors `-• .fir• /. �, , . , . . •X . .6 . . . . X a Partltlona X .. .... X ■ 'A Floors . x ... ■ Flooi ... �•. ,••,,,X ..•.. s R0of1Celling : ( :: .X .... X , .. , ...... z RA Calling 't� .. A... :�t :X :::••:..... _f,�,!f. , ... . Ube Table 9a to determine the Tom eriturs D flerenca Across a listum Air tiepin �J, f 4. INTERNAL HEAT GAIN Latent 'a. Occupants Number • Sensible Latent 1XX.•'•,Y/ ..... ems. b, Lights & Others Watts NOTE: Use W% of IMOuldsscent Lights X 314 Installed watts for Flourescent Light! Li =j.. lights In return .��,X ' air calling. Load usage N.P.H.P. stuh Footor Faelor Motors ..•... .• X. X. .. X. X,. .. .......... X. X. ' Sant Let Usage .....X. ........... ................. X..... ....... Other. ....... , . X. . 'This form designed to ue used With AC,f:A Manual N Psge 1 subtotal Page 1 Subtotsi . INFILTRATION . , .. , .X db Tamp DIff, 11$1min ............. ,X Groins Dlff.. 6-SUBTOTAL COOLINQ i.QAD FOR SPACE 171. SUPPLY DUCT HEAtPAIN Gain factor ..... .... X Line 0 Sensibly Slain.. l ■ Mp 8. ROOM, ZONE OR BLOCK DESIGN LOAD Add dual pain (7) to Subtotal (a) Use this low to astl(tlato the Cooling Cl<M (Line $ 8enfible) (Supply TD) Coallno CFM a .......................... a (1.1 x,..........) a .......... 9. VENTILATION NOTE: For return air Collings db difleranco (outdoor db •plaltum db) WIMIn x 4b Tomp Diff.. t,t ��C .X fI Imin Orlin$ Dill. � y,• .X , ... .%0.81 19. RETURN AIR LOAD FROM LIGHTING AND ROOF NOTO: 460 40% of the Instatlad Incandeacgnt Lights , .... , X3.4 = (t )........ . watts for Lights recalled In a Flourescont Lights, , , . , ... • ... • . , ... X4.1 = ( t i... .. . return air calling. (Roof Loa4) NOTE: Use V value 8 ETD 54. Ft. U factor ETD, tor± roof with no oelling. X , X , ...... , . (t )....... . •(ETD correction based on plenum temper■tun,) NOTE: Subtract the calling Ip�d, rotor to No. s. Gelling Load Credit ............. . .. . (-1... , ... • . 11. R15TURN DUCT HEAT GAIN Gain factor ..... ... , . , . X Line Q S$n$141a Dain.. . ...... . . . . 12, TOTAL LOADS ON EQUIPMENT (Stuh) �t 1i DESIGN CONDITIONS (HEATING) In1l4o db . (-) minus Outsid! db , = Difference. 14. TRANSMISSION LOSSES HEATING LOIAQ db Exposure Sq. Ft Flottor Temp DDlff Windows % X . , Load Nate$ wills . . . . . X . . . .. X .. . . . . . . IF.. x.. � .111� .... x . . . Rltlono X,.,,,,..,,, X ,.,, ■ X. , . , .. , , X .. : , . , . . 15, INFILTRATION 2 r %. fNtmin ........... • . X db Temp RIN , . , , .... 16, SUBTOTAL HEATING LOAD FOR $ CE o 17. SUPPLY DUCT HEAT L SS 1,950 faolor .. , . .. , . X Line 1e Sensible Gain 18. VENTILATION I IOWA , Sb , x db Tomp Off, 19, HUMIDIFICATION LOAD Inside RM(04alrod...... XMax...... ) (.Plmin ...... + too X btumr .. , .... , . • . . wate soda . X al ft $1min ........ + 100 ■ . 20. RETURN DUCT. HEAT LOSS Lose (rotor ................ X Line 16 Lose . _ 2,1, TOTAL HEATING LOAD ON EQUIPMENT (stuh)