Loading...
HomeMy WebLinkAboutINPUT DATA REPORTENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge F1aCom v1.22 INPUT DATA REPORT Project Information Project Name: BH-NSCC Orientation: West Project Title: NORTH SIDE CHRISTIAN CHURCH Building Type: Assembly Address: Building Classification: New Finished building 3100 ST. LUCIE BLVD. State: FL No.of Storeys: ] Zip: 0 GrossArea: 5847 Owner: Zones No Acronym Description Type Load Profile Area Multiplier Total Area [sfl [sfl 1 ZONE 1 Zone 1 CONDITIONED Uses Building Load 2923.0 1 2923.0 ❑ Profile 2 ZONE 2 Zone 2 CONDITIONED Uses Building Load 2924.0 1 2924.0 ❑ Profile 9/1/05 EnergyGauge F1aCom FLCCSB v1.22 1 t 7 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume [ft] IN [ft] plier [sf] [cf] In Zone: ZONE 1 1 ZONE 1 ZONE 1 Lobby (General) - Reception 10.00 292.30 10.00 1 2923.0 29230.0 and Waiting In Zone: ZONE 2 1 ZONE 2 ZONE 2 Lobby (General) - Reception 10.00 292.40 10.00 1 2924.0 29240.0 ❑ and Waiting Lighting No Type Power Control Type No.of INV] Ctrl pts In Zone: ZONE 1 In Space: ZONE 1 1 Incandescent 2900.00 ManualOn/Off 4 In Zone: ZONE 2 In Space: ZONE 2 1 Recessed Fluorescent - No vent 2900.00 Manual On/Off 2 Walls , No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] Capacity [lb/cf] [h.sf.FBtu] [Btu/sf.F] In Zone: ZONE 1 1 ZONE 1 8"CMU/3/4"ISO 104.20 10.00 1 1042.0 North 0.2642 9.6960 62.72 3.79 BTWN24"oc/5/8 Gyp 2 ZONE 1 8"CMU/3/4"ISO 24.20 10.00 1 242.0 East 0.2642 9.6960 62.72 3.79 ❑ BTWN24"oc/5/8 Gyp 9/1/05 EnergyGauge F1aCom FLCCSB v1.22 2 3 ZONE 1 8"CMU/3/4"ISO 24.20 10.00 1 242.0 East 0.2642 9.6960 62.72 3.79 BTWN24"oc/5/8 Gyp In Zone: ZONE 2 1 ZONE 2 8"CMU/3/4"ISO 92.30 10.00 1 923.0 South 0.2642 9.6960 62.72 3.79 BTWN24"oc/5/8 Gyp 2 ZONE 2 8"CMU/3/4"ISO 24.20 10.00 1 242.0 East 0.2642 9.6960 62.72 3.79 BTWN24"oc/5/8 Gyp 3 ZONE 2 8"CMU/3/4"ISO 24.20 10.00 1 242.0 West 0.2642 9.6960 62.72 3.79 BTWN24"oc/5/8 Gyp 4 ZONE 2 8"CMU/3/4"ISO 10.50 10.00 1 105.0 North 0.2642 9.6960 62.72 3.79 ❑ BTWN24"vc/5/8 Gyp Windows No Description Type Shaded UCen SC Vis.Tr W H (Effec) Multi Total Area [Btu/hr sf F] Ift] [ft] plier ISf] In Zone: ZONE 1 In Wall: WALL 1 1 ZONE - 1 SINGLE REF B No 0.8785 0.26 0.05 8.38 8.00 1 67.0 EJ TINT-L In Wall: WALL 2 1 ZONE 1 SINGLE REF B No 0.8785 0:26 0.05 3.00 7.00 1 21.0 TINT-L In Wall: WALL 3 1 ZONE 1 SINGLE REF B No 0.8785 0.26 0.05 4.25 8.00 1 34.0 El TINT-L In Zone: ZONE 2 In Wall: WALL 1 1 ZONE 2 SINGLE REF B No 0.8785 0.,26 0.05 8.38 8.00 1 67.0 TINT-L In Wall: WALL 2 1 ZONE 2 SINGLE REF B No 0.8785 0:26 0.05 3.00 7.00 r 1 21.0 El TINT-L In Wall: WALL 3 1 ZONE 2 SINGLE REF B No 0.8785 0.26 0.05 4.25 8.00 1 34.0 9/1/05 EnergyGauge F1aCom FLCCSB v1.22 3 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] [lb/cfJ [Btu/sf. F] [h.sf.FBtu] In Zone: ZONE 1 In Wall: WALL 1 1 ZONE 1 Solid Urethane No 3.00 7.00 1 21.0 0.2410 0.00 0.00 4.15 ❑ foam core Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [ft] [ft] plier [sf] [deg] [Btu/hr. Sf. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu] In Zone: ZONE 1 1 ZONE 1 Shngl/1/2"WD 292.30 10.00 1 2923.0 0.00 0.0320 1.50 8.22 31.24 ❑ Deck/WD Truss/9" Batt/Gyp Brd In Zone: ZONE 2 1 ZONE 2 Shngl/1/2"WD 292.40 10.00 1 2924.0 0.00 0.0320 1.50 8.22 31.24 ❑ Deck/WD Truss/9" Batt/Gyp Brd Skylights No Description Type UCen Shading Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] Coeff IN [ft] [Sf] [Sf] In Zone: In Roof: El 9/1/05 EnergyGauge F1aCom FLCCSB v1.22 4 Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu] In Zone: ZONE 1 1 ZONE 1 Concrete floor, 292.30 10.00 1 2923.0 0.5987 9.33 140.00 1.67 ❑ carpet and rubber pad In Zone: ZONE 2 1 ZONE 2 Concrete floor, 292.40 10.00 1 2924.0 0.5987 9.33 140.00 1.67 ❑ carpet and rubber Systems ZONE 1 System 1 Constant Volume Packaged Multizone System No. Of Units 1 Component Category Capacity Efficiency IPLV 1 2 Cooling System (Air Cooled 65000 to 135000 Btu/h Cooling Capacity) Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 120000.00 10.00 9.00 1500.00 0.80 0 ❑ ZONE 2 System 2 Constant Volume Packaged Multizone System No. Of Units 1 Component Category Capacity Efficiency IPLV 1 2 Cooling System (Air Cooled 65000 to 135000 Btu/h Cooling Capacity) Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 120000.00 10.00 9.00 1500.00 0.80 ❑ ❑ Plant Equipment Category Size Inst.No Eff. IPLV 9/1/05 EnergyGauge F1aCom FLCCSB v1.22 5 Water Heaters W-Heater Description Capacit Cap.Unit UP Rt. Efficienc Loss 1 Storage Water Heater - Electric 40 Gal 1 [kW] 0.8800 [EF] [%/hr] Ext-Lighting Description Categories. Area/Len/No. of units [sf/ft/No] Wattage [W] 1 Ext Light 1 Exit (with or without Canopy) 100.00 2500.00 Piping No Type Operating Insulation Temperature Conductivity [F] [ Btu-in/h.sLF] Nomonal pipe Diameter [in] Insulation Is Runout? Thickness [in] El Fenestration Used Name Glass Type No. of Glass SC VLFrame Frame Conductance Panes T Conductance Absorptance tu/h.sLF [B ] [Btu/h.sf.F] ApLbWnd4 SINGLE REF B 1 0.8785 0.2600 0.0500 0.4340 0.7000 ❑ TINT-L 9/1/05 EnergyGauge F1aCom FLCCSB v1.22 6 Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHeat Mat No Acronym Description Used [h.sf.FBtu] [ft] [Btu/h.ft.F] [lb/cf] [Btu/1b.F] 18 Mat118 2 in. Wood No 2.3857 0.1670 0.0700 37.00 0.3900 ❑ 264 Mat1264 ALUMINUM, 1/16IN No 0.0002 0.0050 26.0000 480.00 0.1000 0 214 Mat1214 POLYSTYRENE, EXP., No 5.2100 0.1042 0.0200 1.80 0.2900 ❑ 1-1/4IN, 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ BOARD,1/2IN 206 Mat1206 CELLULOSE,FILL,5.5IN,R- No 20.8318 0.4583 0.0220 3.00 0.3300 ❑ 20 151 Matll51 CONC HW, DRD, 140LB, No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 4IN 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300. ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 123 Mat1123 CONC BLOCK No 1.7227 0.6667 0.3870 53.00 0.2000 ❑ MW,8IN,HOLLOW 159 Mat1159 CONC No 0.3202 0.3333 1.0410 140.00 0.2000 ❑ HW-UNDRD-140LB-4IN 57 Mat157 3/4 in. Plaster or gypsum No 0.1488 0.0625 0.4200 100.00 0.2000 ❑ 72 Mat172 AIR LAYER, 3/41N OR Yes 0.9000' ❑ LESS, VERT. WALLS 267 Mat1267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 ❑ 266 Mat1266 2x4@16" oc + Rl 1 Batt No 8.3343 0.2917 0.0350 9.70 0.2000 ❑ 215 Mat1215 POLYSTYRENE, EXP., No 8.3350 0.1667 0.0200 1.80 0.2900 ❑ 2IN, 105 Mat1105 CONC BLK HW, 8IN, No 1.1002 0.6667 0.6060 69.00 0.2000 ❑ HOLLOW 256 Mat1256 WOOD, SOFT, 1-1/2IN No 1.8939' 0.1250 0.0660 32.00 0.3300 ❑ 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000 ❑ 42 Matl42 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ block 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 86 Matl86 BRICK, COMMON, 4IN No 0.8012' 0.3333 0.4160 120.00 0.2000 ❑ 211 Matl2ll POLYSTYRENE,EXP.,1/2I No 2.0850 0.0417 0.0200 _ 1.80 0.2900 _❑ 9/1/05 EnergyGauge FlaCom FLCCSB v1.22 7 12 Mat112 3 in. Insulation 218 Mat1218 POLYURETHANE,EXP.,1/2 IN, 23 Mat123 6 in. Insulation 4 Matl4 Steel siding 271 Mat1271 2x4@24" oc + Rl 1 Batt 272 Mat1272 Panel with 7/16" panels 273 Mat1273 Hollow core flush (1.375") 274 Mat1274 Solid core flush (1.375") 275 Mat1275 Panel with 7/16" panels (1.375") 276 Mat1276 Hollow core flush (1.75") 277 Mat1277 Panel with 1-1/8" panels (1.75") 278 Mat1278 Solid core flush (1.75") 279 Mat1279 Solid core flush (2.25") 280 Mat1280 Fiberglass/Mineral wool core 281 Mat1281 Paper Honeycomb core 282 Mat1282 Solid Urethane foam core 283 Mat1283 Solid mineral fiberboard core 284 Mat1284 Polystyrene core (18 ga steel) 1 285 Mat1285 Polyurethane core (18 ga steel) 2 286 Mat1286 Polyurethane core (24 ga steel) 1 287 Mat1287 Polyurethane core (24 ga steel) 2 288 Mat1288 Solid Urethane foam core 81 Mat181 ASPHALT -ROOFING, ROLL 244 Mat1244 PLYWOOD, 1/2IN 185 Mat1185 CLAY TILE, PAVER, 3/8IN 82 Matl82 ASPHALT -SHINGLE AND SIDING 11 Matll 1 2 in. Insulation 47 Mat147 2 in. Heavyweight concrete 95 Mat195 CONC BLOCK - - -HW 41N-HOLLOW---- 9/1/05 No 10.0000 0.2500 0.0250 2.00 0.2000 LJ No 3.2077. 0.0417 0.0130 1.50 0.3800 ❑ No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ No 10.4179 0.2917 0.0280 7.11 0.2000 ❑ Yes 0.9044 ❑ Yes 1.2777 ❑ Yes 1.7141 ❑ Yes 1.0019 ❑ Yes 1.3239, ❑ Yes 1.7141 ❑ Yes 1.6500 ❑ Yes 2.8537 ❑ Yes 0.8167 ❑ Yes 0.9357 ❑ Yes 1.6500 ❑ Yes 1.7816 ❑ Yes 2.0071 ❑ Yes 2.5983 ❑ Yes 2.5983' ❑ Yes 4.1500 ❑ Yes 4.1500 ❑ Yes 0.1500 ❑ No 0.6318 0.0417 0.0660 34.00 0.2900 ❑ No 0.0301, 0.0313 1.0410 120.00 0.2000 ❑ Yes 0.4400 ❑ No 6.6800 0.1670 0.0250 2.00 0.2000 ❑ No 0.1670 0.1670 1.0000 140.00 0.2000 ❑ No 0.7101 0.3333 0.4690 101.00 0.2000 ❑ EnergyGauge FlaCom FLCCSB v1.22 8 • M 248 Mat1248 ROOF GRAVEL OR No SLAG1/2IN 0.0500 0.0417 0.8340 55.00 0.4000 ❑ 94 Mat194 BUILT-UP ROOFING, No 3/81N 0.3366 0.0313 0.0930 70.00 0.3500 ❑ Constructs Used No Name Simple Construct Massless Conductance Heat Capacity Construct [Btu/h.sLF] [Btu/sf.F] Density [lb/cf] RValue [h.sLFBtu] 1004 Concrete floor, carpet and rubber pad No No 0.60 9.33 140.00 1.6703 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 151 CONC HW, DRD, 140LB, 41N 0.3333 0.00 ❑ 2 178 CARPET W/RUBBER PAD 0.00 ❑ No Name Simple Construct Massless Conductance Heat Capacity Construct [Btu/h.sf.F] [Btu/sf.Fj Density [lb/cf] RValue [h.sf.FBtu] 1014 8"CMU/3/4"ISO BTWN24"oc/5/8 Gyp No No 0.26 9.70 62.72 3.7856 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 105 CONC BLK HW, 8IN, HOLLOW 0.6667 0.00 ❑ 2 269 .75" ISO BTWN24" oc 0.0625 0.00 ❑ 3 187 GYP OR PLAS BOARD, WIN 0� 0417 0.00 ❑ No Name Simple Construct Massless Conductance Construct [Btu/h.sf.F] Heat Capacity [Btu/sf.F] Density " [lb/cf] RValue [h.sf.FBtu] 1037 Solid Urethane foam core No Yes 0.24 4.1500 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 288 Solid Urethane foam core 0.00 ❑ 9/1/05 EnergyGauge FlaCom FLCCSB v1.22 9 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1038 Shngl/1/2"WD Deck/WD Truss/9" Batt/Gyp No No 0.03 1.50 8.22 31.2351 ❑ Brd Layer Material Material Thickness Framing No. [ft] Factor 1 81 ASPHALT -ROOFING, ROLL 0.00 ❑ 2 244 PLYWOOD, 1/2IN 0.0417 0.00 ❑ 3 12 3 in. Insulation 0.2500 0.00 ❑ 4 23 6 in. Insulation 0.5000 0.00 ❑ 5 187 GYP OR PLAS BOARD,1/21N 0.0417 0.00 ❑ 9/1/05 EnergyGauge F1aCom FLCCSB v1.22 • 10