Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
INPUT DATA REPORT
ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge F1aCom v1.22 INPUT DATA REPORT Project Information Project Name: BH-NSCC Orientation: West Project Title: NORTH SIDE CHRISTIAN CHURCH Building Type: Assembly Address: Building Classification: New Finished building 3100 ST. LUCIE BLVD. State: FL No.of Storeys: ] Zip: 0 GrossArea: 5847 Owner: Zones No Acronym Description Type Load Profile Area Multiplier Total Area [sfl [sfl 1 ZONE 1 Zone 1 CONDITIONED Uses Building Load 2923.0 1 2923.0 ❑ Profile 2 ZONE 2 Zone 2 CONDITIONED Uses Building Load 2924.0 1 2924.0 ❑ Profile 9/1/05 EnergyGauge F1aCom FLCCSB v1.22 1 t 7 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume [ft] IN [ft] plier [sf] [cf] In Zone: ZONE 1 1 ZONE 1 ZONE 1 Lobby (General) - Reception 10.00 292.30 10.00 1 2923.0 29230.0 and Waiting In Zone: ZONE 2 1 ZONE 2 ZONE 2 Lobby (General) - Reception 10.00 292.40 10.00 1 2924.0 29240.0 ❑ and Waiting Lighting No Type Power Control Type No.of INV] Ctrl pts In Zone: ZONE 1 In Space: ZONE 1 1 Incandescent 2900.00 ManualOn/Off 4 In Zone: ZONE 2 In Space: ZONE 2 1 Recessed Fluorescent - No vent 2900.00 Manual On/Off 2 Walls , No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] Capacity [lb/cf] [h.sf.FBtu] [Btu/sf.F] In Zone: ZONE 1 1 ZONE 1 8"CMU/3/4"ISO 104.20 10.00 1 1042.0 North 0.2642 9.6960 62.72 3.79 BTWN24"oc/5/8 Gyp 2 ZONE 1 8"CMU/3/4"ISO 24.20 10.00 1 242.0 East 0.2642 9.6960 62.72 3.79 ❑ BTWN24"oc/5/8 Gyp 9/1/05 EnergyGauge F1aCom FLCCSB v1.22 2 3 ZONE 1 8"CMU/3/4"ISO 24.20 10.00 1 242.0 East 0.2642 9.6960 62.72 3.79 BTWN24"oc/5/8 Gyp In Zone: ZONE 2 1 ZONE 2 8"CMU/3/4"ISO 92.30 10.00 1 923.0 South 0.2642 9.6960 62.72 3.79 BTWN24"oc/5/8 Gyp 2 ZONE 2 8"CMU/3/4"ISO 24.20 10.00 1 242.0 East 0.2642 9.6960 62.72 3.79 BTWN24"oc/5/8 Gyp 3 ZONE 2 8"CMU/3/4"ISO 24.20 10.00 1 242.0 West 0.2642 9.6960 62.72 3.79 BTWN24"oc/5/8 Gyp 4 ZONE 2 8"CMU/3/4"ISO 10.50 10.00 1 105.0 North 0.2642 9.6960 62.72 3.79 ❑ BTWN24"vc/5/8 Gyp Windows No Description Type Shaded UCen SC Vis.Tr W H (Effec) Multi Total Area [Btu/hr sf F] Ift] [ft] plier ISf] In Zone: ZONE 1 In Wall: WALL 1 1 ZONE - 1 SINGLE REF B No 0.8785 0.26 0.05 8.38 8.00 1 67.0 EJ TINT-L In Wall: WALL 2 1 ZONE 1 SINGLE REF B No 0.8785 0:26 0.05 3.00 7.00 1 21.0 TINT-L In Wall: WALL 3 1 ZONE 1 SINGLE REF B No 0.8785 0.26 0.05 4.25 8.00 1 34.0 El TINT-L In Zone: ZONE 2 In Wall: WALL 1 1 ZONE 2 SINGLE REF B No 0.8785 0.,26 0.05 8.38 8.00 1 67.0 TINT-L In Wall: WALL 2 1 ZONE 2 SINGLE REF B No 0.8785 0:26 0.05 3.00 7.00 r 1 21.0 El TINT-L In Wall: WALL 3 1 ZONE 2 SINGLE REF B No 0.8785 0.26 0.05 4.25 8.00 1 34.0 9/1/05 EnergyGauge F1aCom FLCCSB v1.22 3 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] [lb/cfJ [Btu/sf. F] [h.sf.FBtu] In Zone: ZONE 1 In Wall: WALL 1 1 ZONE 1 Solid Urethane No 3.00 7.00 1 21.0 0.2410 0.00 0.00 4.15 ❑ foam core Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [ft] [ft] plier [sf] [deg] [Btu/hr. Sf. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu] In Zone: ZONE 1 1 ZONE 1 Shngl/1/2"WD 292.30 10.00 1 2923.0 0.00 0.0320 1.50 8.22 31.24 ❑ Deck/WD Truss/9" Batt/Gyp Brd In Zone: ZONE 2 1 ZONE 2 Shngl/1/2"WD 292.40 10.00 1 2924.0 0.00 0.0320 1.50 8.22 31.24 ❑ Deck/WD Truss/9" Batt/Gyp Brd Skylights No Description Type UCen Shading Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] Coeff IN [ft] [Sf] [Sf] In Zone: In Roof: El 9/1/05 EnergyGauge F1aCom FLCCSB v1.22 4 Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu] In Zone: ZONE 1 1 ZONE 1 Concrete floor, 292.30 10.00 1 2923.0 0.5987 9.33 140.00 1.67 ❑ carpet and rubber pad In Zone: ZONE 2 1 ZONE 2 Concrete floor, 292.40 10.00 1 2924.0 0.5987 9.33 140.00 1.67 ❑ carpet and rubber Systems ZONE 1 System 1 Constant Volume Packaged Multizone System No. Of Units 1 Component Category Capacity Efficiency IPLV 1 2 Cooling System (Air Cooled 65000 to 135000 Btu/h Cooling Capacity) Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 120000.00 10.00 9.00 1500.00 0.80 0 ❑ ZONE 2 System 2 Constant Volume Packaged Multizone System No. Of Units 1 Component Category Capacity Efficiency IPLV 1 2 Cooling System (Air Cooled 65000 to 135000 Btu/h Cooling Capacity) Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 120000.00 10.00 9.00 1500.00 0.80 ❑ ❑ Plant Equipment Category Size Inst.No Eff. IPLV 9/1/05 EnergyGauge F1aCom FLCCSB v1.22 5 Water Heaters W-Heater Description Capacit Cap.Unit UP Rt. Efficienc Loss 1 Storage Water Heater - Electric 40 Gal 1 [kW] 0.8800 [EF] [%/hr] Ext-Lighting Description Categories. Area/Len/No. of units [sf/ft/No] Wattage [W] 1 Ext Light 1 Exit (with or without Canopy) 100.00 2500.00 Piping No Type Operating Insulation Temperature Conductivity [F] [ Btu-in/h.sLF] Nomonal pipe Diameter [in] Insulation Is Runout? Thickness [in] El Fenestration Used Name Glass Type No. of Glass SC VLFrame Frame Conductance Panes T Conductance Absorptance tu/h.sLF [B ] [Btu/h.sf.F] ApLbWnd4 SINGLE REF B 1 0.8785 0.2600 0.0500 0.4340 0.7000 ❑ TINT-L 9/1/05 EnergyGauge F1aCom FLCCSB v1.22 6 Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHeat Mat No Acronym Description Used [h.sf.FBtu] [ft] [Btu/h.ft.F] [lb/cf] [Btu/1b.F] 18 Mat118 2 in. Wood No 2.3857 0.1670 0.0700 37.00 0.3900 ❑ 264 Mat1264 ALUMINUM, 1/16IN No 0.0002 0.0050 26.0000 480.00 0.1000 0 214 Mat1214 POLYSTYRENE, EXP., No 5.2100 0.1042 0.0200 1.80 0.2900 ❑ 1-1/4IN, 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ BOARD,1/2IN 206 Mat1206 CELLULOSE,FILL,5.5IN,R- No 20.8318 0.4583 0.0220 3.00 0.3300 ❑ 20 151 Matll51 CONC HW, DRD, 140LB, No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 4IN 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300. ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 123 Mat1123 CONC BLOCK No 1.7227 0.6667 0.3870 53.00 0.2000 ❑ MW,8IN,HOLLOW 159 Mat1159 CONC No 0.3202 0.3333 1.0410 140.00 0.2000 ❑ HW-UNDRD-140LB-4IN 57 Mat157 3/4 in. Plaster or gypsum No 0.1488 0.0625 0.4200 100.00 0.2000 ❑ 72 Mat172 AIR LAYER, 3/41N OR Yes 0.9000' ❑ LESS, VERT. WALLS 267 Mat1267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 ❑ 266 Mat1266 2x4@16" oc + Rl 1 Batt No 8.3343 0.2917 0.0350 9.70 0.2000 ❑ 215 Mat1215 POLYSTYRENE, EXP., No 8.3350 0.1667 0.0200 1.80 0.2900 ❑ 2IN, 105 Mat1105 CONC BLK HW, 8IN, No 1.1002 0.6667 0.6060 69.00 0.2000 ❑ HOLLOW 256 Mat1256 WOOD, SOFT, 1-1/2IN No 1.8939' 0.1250 0.0660 32.00 0.3300 ❑ 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000 ❑ 42 Matl42 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ block 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 86 Matl86 BRICK, COMMON, 4IN No 0.8012' 0.3333 0.4160 120.00 0.2000 ❑ 211 Matl2ll POLYSTYRENE,EXP.,1/2I No 2.0850 0.0417 0.0200 _ 1.80 0.2900 _❑ 9/1/05 EnergyGauge FlaCom FLCCSB v1.22 7 12 Mat112 3 in. Insulation 218 Mat1218 POLYURETHANE,EXP.,1/2 IN, 23 Mat123 6 in. Insulation 4 Matl4 Steel siding 271 Mat1271 2x4@24" oc + Rl 1 Batt 272 Mat1272 Panel with 7/16" panels 273 Mat1273 Hollow core flush (1.375") 274 Mat1274 Solid core flush (1.375") 275 Mat1275 Panel with 7/16" panels (1.375") 276 Mat1276 Hollow core flush (1.75") 277 Mat1277 Panel with 1-1/8" panels (1.75") 278 Mat1278 Solid core flush (1.75") 279 Mat1279 Solid core flush (2.25") 280 Mat1280 Fiberglass/Mineral wool core 281 Mat1281 Paper Honeycomb core 282 Mat1282 Solid Urethane foam core 283 Mat1283 Solid mineral fiberboard core 284 Mat1284 Polystyrene core (18 ga steel) 1 285 Mat1285 Polyurethane core (18 ga steel) 2 286 Mat1286 Polyurethane core (24 ga steel) 1 287 Mat1287 Polyurethane core (24 ga steel) 2 288 Mat1288 Solid Urethane foam core 81 Mat181 ASPHALT -ROOFING, ROLL 244 Mat1244 PLYWOOD, 1/2IN 185 Mat1185 CLAY TILE, PAVER, 3/8IN 82 Matl82 ASPHALT -SHINGLE AND SIDING 11 Matll 1 2 in. Insulation 47 Mat147 2 in. Heavyweight concrete 95 Mat195 CONC BLOCK - - -HW 41N-HOLLOW---- 9/1/05 No 10.0000 0.2500 0.0250 2.00 0.2000 LJ No 3.2077. 0.0417 0.0130 1.50 0.3800 ❑ No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ No 10.4179 0.2917 0.0280 7.11 0.2000 ❑ Yes 0.9044 ❑ Yes 1.2777 ❑ Yes 1.7141 ❑ Yes 1.0019 ❑ Yes 1.3239, ❑ Yes 1.7141 ❑ Yes 1.6500 ❑ Yes 2.8537 ❑ Yes 0.8167 ❑ Yes 0.9357 ❑ Yes 1.6500 ❑ Yes 1.7816 ❑ Yes 2.0071 ❑ Yes 2.5983 ❑ Yes 2.5983' ❑ Yes 4.1500 ❑ Yes 4.1500 ❑ Yes 0.1500 ❑ No 0.6318 0.0417 0.0660 34.00 0.2900 ❑ No 0.0301, 0.0313 1.0410 120.00 0.2000 ❑ Yes 0.4400 ❑ No 6.6800 0.1670 0.0250 2.00 0.2000 ❑ No 0.1670 0.1670 1.0000 140.00 0.2000 ❑ No 0.7101 0.3333 0.4690 101.00 0.2000 ❑ EnergyGauge FlaCom FLCCSB v1.22 8 • M 248 Mat1248 ROOF GRAVEL OR No SLAG1/2IN 0.0500 0.0417 0.8340 55.00 0.4000 ❑ 94 Mat194 BUILT-UP ROOFING, No 3/81N 0.3366 0.0313 0.0930 70.00 0.3500 ❑ Constructs Used No Name Simple Construct Massless Conductance Heat Capacity Construct [Btu/h.sLF] [Btu/sf.F] Density [lb/cf] RValue [h.sLFBtu] 1004 Concrete floor, carpet and rubber pad No No 0.60 9.33 140.00 1.6703 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 151 CONC HW, DRD, 140LB, 41N 0.3333 0.00 ❑ 2 178 CARPET W/RUBBER PAD 0.00 ❑ No Name Simple Construct Massless Conductance Heat Capacity Construct [Btu/h.sf.F] [Btu/sf.Fj Density [lb/cf] RValue [h.sf.FBtu] 1014 8"CMU/3/4"ISO BTWN24"oc/5/8 Gyp No No 0.26 9.70 62.72 3.7856 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 105 CONC BLK HW, 8IN, HOLLOW 0.6667 0.00 ❑ 2 269 .75" ISO BTWN24" oc 0.0625 0.00 ❑ 3 187 GYP OR PLAS BOARD, WIN 0� 0417 0.00 ❑ No Name Simple Construct Massless Conductance Construct [Btu/h.sf.F] Heat Capacity [Btu/sf.F] Density " [lb/cf] RValue [h.sf.FBtu] 1037 Solid Urethane foam core No Yes 0.24 4.1500 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 288 Solid Urethane foam core 0.00 ❑ 9/1/05 EnergyGauge FlaCom FLCCSB v1.22 9 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1038 Shngl/1/2"WD Deck/WD Truss/9" Batt/Gyp No No 0.03 1.50 8.22 31.2351 ❑ Brd Layer Material Material Thickness Framing No. [ft] Factor 1 81 ASPHALT -ROOFING, ROLL 0.00 ❑ 2 244 PLYWOOD, 1/2IN 0.0417 0.00 ❑ 3 12 3 in. Insulation 0.2500 0.00 ❑ 4 23 6 in. Insulation 0.5000 0.00 ❑ 5 187 GYP OR PLAS BOARD,1/21N 0.0417 0.00 ❑ 9/1/05 EnergyGauge F1aCom FLCCSB v1.22 • 10