Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEs FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION lorida Department of Business and Professional Regulation - Residential Performance Method.: Project Name: Standard Pacific RB Yorkshire Lot 45 Builder Name: Standard Pacific Homes Street: 3co4 Ow Ro►d-v+.rri't� Permit Office: City, State, Zip: Port St. Lucie , FL , - - Permit Number: Owner: Standard Pacific Homes Jurisdiction: Design Location: :, FL, ST LUCIE_CO INTL 1. New construction or existing New (From Plans) 9. Wall Types (3646.5 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul„Exterior R=4.1 3321.06 ft2 b. Frame - Wood, Adjacent R=11.0 325.43 ft2 3. Number of units, if multiple family 1 c. N/A R=' ft2 4; Number of Bedrooms 4 d. N/A R=. ftz No 10. Ceiling Types (3638.0 sqft.) Insulation:: Area 5. Is this a worst case? a. Under Attic (Vented) R=38.0 3638:00 ft2 6. Conditioned floor area above grade (ft2) 3638 b. N/A R= ` f.:` ., ' ' - ft2 Conditioned Hoot area below grade (ftz) 0 c. N/A 'R= . ` . ft2 , 11. Ducts =R' .ftz " 7. I/Uintlows(931.7 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AC 1 First Floor "° 6- 360• a. U-Factor: Sgl, U=1.07 438.67 ft2 b. Sup: Attic, Ret: Attic, AH: AC.1 First Floor '; • - 6 220 SHGC: SHGC=0.30 b. U-Factor: • Sgl, U=1.05 288.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a. Central Unit 58.5 SEER:14.p0 ' c. U-Factor: Sgl, U70.77 ' • 136.00 ft2 b. Central Unit .. :17.8 SEER:14.00 SHGC: SHGC=0.22 .13. Heating systems kBtuft Efficiency d. U-Factor: other (see details) 68.99 ft2 a. Electric Heat Pump 55:5.­- H8PFt8:00 •- . SHGC: other (see details) b. Electric Heat Pump •;. s ' -17.6 , HSI?F:8.00 Are Weighted Average Overhang Depth: 8.711 ft. W ' Area Weighted Average SHGC: 0.284. 14. Hot water systems ; a. Natural Gas Cap. 40 gallons " 8. Floor Types (3638.0 sqft.) Insulation Area a a'. Slab -On -Grade, Edge Insulation R=0.0 '3638.00 ft2 b. Conservation features b. NIA R= ft2 None ". T c. N/A R= ft2 15: Credits ' Pstat Total Proposed Modified Loads: 50.84 /� S Glass/Floor Area: 0.256 Total Standard Reference Loads: 65.31 r ~�"_ 1 I hereby certify that the plans and specifications covered by Review of the plans and O�fiSAZ� this calculation are in compliance with the lorida Energy 1 specifications covered by this Gii Digitally signed y Chris Wildroud Code, C h r I s DN: cn=Chris Wildroudt, c=US, calculation indicates com liance,,•'•', p with the. Florida. Energy Code.' i.,,°`-�' ki ; „ -S, ., - - `` . { o=Engineered Air, LLC, ou=New Construction Sales and PREPARED BY: Before construction is completed ` ngmeenng, DATE: Z �emaih Ic. this building will be ins ected for' 9 P y ` �m Date: 2015.03.23 11:04:14-04'00' compliance with Section 553;908'.. * d. I hereby certify that this building, as � igned, is in compliance Florida Statutes. �. g't with the Florida Energy OWNER/AGENT: BUILDING OF.,FICIAL:.,.. DATE: 2 t S- DATE:v. - Compliance requires certification by the air handier unit manufacturer that the air handler enclosu"re;,qualifies as certi led factory -sealed in accordance with 403.2.2.1.1. - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist - Heat sys #1 may be undersized. Size of 65.5 was increased to 69.7 for simulation. Please review the Manual J8°report.- Heat sys #2 may be undersized. Size of 17.6 was increased to 19.6 for simulation. Please review the Manual J8 report. I . . 3/23/2015 10:14 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant So tarC0P P ge 1. of 6 i PROJECT Title: Standard Pacific RB Yorkshir Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 3638 Lot # 45 Owner: Standard Pacific Homes Total Stories: 1 Block/SubDivision: Riverbend , • # of Units: 1 Worst Case: No PlatBook: Builder Name: Standard Pacific Homes Rotate Angle: 0 Street: Permit Office: Cross Ventilation: , County: St. Lucie . Jurisdiction: Whole House Fan: City, State, Zip: 'Port St: Lucie , Family Type: Single-family FL, New/Existing: " New (From Plans) , Comment: CLIMATE / IECC Design Temp Int.Design Temp Heating ;";.DesignDaily Temp V Design Location TMY'Site Zone 97.5 % 2.5 % Winter Summer Degree Ddys Moisture Range-._ _ I 'FL, ST_LUCIE_CO_INTL FL ST_LUCIE_CO_INTL 2 39 90 70 75 722 58, , Medium BLOCKS ' Number Name Area Volume w 1 Blockl • 2769 29992.7558 2 61ock2 869 9272.23046 'N SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished. Cooled' - Heated r 1 AC 1 First Floor 2769 29992.7557 No 5 3 e 1 Yes Yes Yes 2 AC 2 Secohd Floor 869 9272.23 No 2 1 1 Yes' Yes- Yes., FLOORS . # Floor Type Space Perimeter Perimeter R-Valuer Area "Joist R-Value, .:Tile. ' W60d .Carpet - 1 Slab -On -Grade Edge Insulatio AC 1 First Floor 248 ft 0 ''. 2769 ft2, 0 2 Slab -On -Grade Edge Insulatio AC 2 Second Flo 91 ft 0 869 ft2. _:__. .- 0 ;' 0 1 ' ROOF Roof Gable Roof _ Solar SA +, Emltt Emitt Deck ° , Pitch # Type Materials Area Area Color AbSor: j .; Tested ' ;` + Tested Insul (deg) 1 Hip Barrel tile 4069 ft2 0 ft2 Medium 0.65 .. No 0.9 No',- ...0 .,_,,,;26.6, ATTIC Type Ventilation Vent Ratio (1 1r , . Area- RBS IRCC 1 I , Full attic Vented 300 3638 ft2 N N 3/23/2015 10:14 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software I CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) AC 1 First Floor 38 2769 ft2 0.11 Wood ' 2 I Under Attic (Vented) AC 2 Second Flo 38 869 ft2 0.11 , _ Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below ()mt TO Space Wall Type_ 1� E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 13 0 10.67 0 138.7100 0.1. 0 0.4 0 2� E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 10 0 10.67 0 106.6999 .0.4 0 0.4 0 _ _ 3 E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 13 0 10.67 0 138.7100 `0:4 0 0:4 0 ,A! E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 12 0 10.67 0 128.0400 0.4 0 0.4 0 5, S Exterior Concrete Block- Int InsAC 1 First Flo 4.1 80 0 10.67 0 853.5999 0A 0 - '0.4'-- .._0 61 S Exterior Concrete. Block - Int InsAC 1 First Flo 4.1 13.5 0 10.67 0 " 144.0449 0.4 ..0 0.4 0 71 W Exterior Concrete Block - Int InsW 1 First Flo 4.1 34 0 10.67 0 ; : 362.7799 0.4 ,. 0 04 0 8! W Exterior. Concrete Block - Int IrisAC 1 First Flo 4.1 20 0 12.67 0 253.3999 0:4: 0 0.4 0 9 N Exterior Concrete Block - int InsAC 1 First Flo 4.1 14 0 10.67 0 149.3800 0.4 0 0.4 0 10 N Exterior Concrete Block - Int InsW 1 First Flo 4.1 24 0 10.67 0 256.0800 0.4. 0 0.4 0 -I! N Garage Frame - Wood AC 1 First Flo 11 8 0 10.67 0 85.36000 .0.4 0.4 0 _ 12 W i Garage Frame - Wood AC 1 First Flo 11 6 0, 10.67' •`0 64.02600 ,'0.4. 0.4 0 13 W Exterior Concrete Block - Int InsAC 2 Second 4.1 18 0 10.67 s 0 192.0599 , `' 0:4 0 ,.. 0.4 0 14 N Exterior Concrete Block - Int InsAC 2 Second 4.1 50 0. 10.67,:, 0 533.5 ft2 0.4 0 0.4 0 ., _ 15 S Exterior Concrete Block - Int InsAC 2 Second 4.1 6 0 10.67", 0 64.02000 0.4 0 -0.4 0 16 E Garage Frame - Wood AC 2 Second 11 16.5 0 10.67 0 176.0550 1 0.4 0.23• 0.4 0 DOORS _ # Omt Door Type Space Storms _!U-Value : Width Height`• • Area Ft - In Ft -'In 1 ' : W Insulated AC 1 First Flo None,. 0.6 2.67' 0, ," , 8 ' 0 21:36'ft2 WINDOWS: Orientation shown is the entered, Proposed orientation. / Wall ; Overharig„ # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Single Yes 0.77 0.22.. . , '48 ft2_ ; 23 ft 0 in 210 in 'None None 2 E 1 Metal Low-E Single Yes 1 0.32 : . °' :24.28000 23 ft0. in. 2 ft 0 in .. None None 3 E 2 Metal Low-E Single Yes 0.77 0.22 48 ft2 13 ft 0 in 2 ft 0 in None None " 4 E 3 Metal Low-E Single Yes 1.07 0.3 ' 16.17000 6 ft 0 in 2ft 0 in None None 5 E 4 Metal Low-E Single Yes 0.77 0.22 40 ft2 " ,8 ft 0 in 2 ft 0 in... None ' None 6 S 5 Metal Low-E Single Yes 1.07 0.3 :116.978.3 1.33 ft 01 2,. .0 in} None, None 7 S 5 Metal Low-E Single Yes 1.07 0.3 22.68000 1.33 ft 0 i 2.ft 0 ip None None 8 S 5 Metal Low-E Single Yes 1.07 0.3 9.180000 1.33 ft 0 i 2 ft 0 in None None 9 S 6 Metal Low-E Single Yes 1.05 0.28 80 ft2 18 ft 0 in 2 ft 0 in None None 10 W 7 Metal Low-E Single Yes 1.07 0.3 116.9783 1.33 ft0 i 2 ft 0 in None None 1 11 W 8 Metal Low-E Single Yes 1.05 0.28 128 ftz ,, 12 ft 0 in 4.67 ft 0 i None None 12 W 8 Metal Low-E Single Yes 1 0.32 24.86439 12 ft-0 in 1 ft 0 in None None 13 N 9 Metal Low-E Single Yes 1.05 0.28 80 ft2 18 ft 0 in 2 ft 0 in None None 3/23/2015 10:14 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 C I WINDOWS Orientation shown is the entered, Proposed orientation.. ' / Wall Overhang V j # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation,! ;.Int,Shad6 Screening.•'. 14 N 10 Metal Low-E Single Yes 1.07 0.3 22.68000 9 ft 0 in -2 ft 0 in None None 15 W 13 Metal Low-E Single Yes 1.07 0.3 58.48919 1.33 ft 0 i 2•ft 0 in None None. 16 N 14 Metal Low-E.Single Yes 1.07 0.3 13.67280 1.33 ft 0 i 2-ft 0 in- None:' None , 17 N 14 Metal Low-E Single Yes 1.07 0.3 38.99279 1.33 ft 0-i 2 ft 0 in None None - ` 18 N 14 Metal Low-E Single Yes 1.07 0.3 9.180000 1.33 ft 0 i 2 ft 0 in None None 19 N 14 Metal Low-E Single Yes 1 0.32 16.17000`1.33 ft 0 i 2 ft 0 in None None 20 N 14 Metal Low-E Single Yes 1 0.32 6.652800 1.33 ft-0 i 210 in None •" None 21 S 15 Metal Low-E Single Yes 1.07 0.3 13.67280 1.33 ft 0 j 2 ft 0 in None None. , GARAGE W # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 640 ft' 640 ft' 78 ft 16 ft `1" INFILTRATION # IScope Method SLA CFM 50 ELA EgLA ACH' ACH 50 1 Wholehouse Best Guess. 0.000500 4771.2 261.93 492.60 : 0,3750 7.2908 r . HEATING SYSTEM # System Type Subtype Efficiency. l Capaciti'� Block Ducts 1 Electric Heat Pump None HSPF: 8. 55'5. kBtu/hr 1 sys#1 i 2 Electric Heat Pump None HSPF: 8>;` . - .17.6 kBtu/fir • .. 2 sys#2 COOLING SYSTEM ` # System Type Subtype Efficiency .,Capacity: 'Aic Flow ,' ,SHR r,,," Block; , '.• Ducts 1 Central Unit Split SEER:;1* 58.5 kBtu/hr �755 +cfm 0 75 1' - sys#1 • 2 Central Unit Split SEER: -14 17.8 kBtu/hr `. 534'cfm 0,75, , 2 sys#2- HOT WATER SYSTEM # System Type SubType Location EF Cap Use : S@tPnt Conservation 1 Natural Gas None Garage 0.59 40 gal 70,gal 120 deg,. None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model #. Collector Model # Area volume • '. FEF'. (None None ftz 3/23/2015 10:14 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software i Page 4 of 6 DUCTS ---- Supply --- ---- Return ---- Air Percent HVAC # # Location R-Value Area Location Area' Leakage Type Handler CFM 25 Leakage QN RLF• Heat Cool 1 2 Attic 6 Attic 6 360 ftz 220 ftZ Attic Attic 120 ftZ 120 ftZ Default Leakage Default Leakage AC 1 First F (Default) (Default) % AC 1 First F (Default) (Default) % 1 1 2 2, TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [[ ]]Jan [X] Jan [[ ]]Feb [X] Feb Mar JX� Mar Apr May (X] Jun rlJul Jun Jul rX Aug [ Aug Sep Oct Sep Oct rl Nov Nov DecHeating Dec Venting [ ] Jan � r 1 Feb Mar Apr May L 1 Jun . Jul [ . Aug Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 , 12 Cooling (WD) AM 78 78 78 78 78 78 78• 78 8080 80 80 PM 80 80 78 78 78 78 78 .78 78, 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78" 78 .78 ., 78 " PM 78 78 78 78 78 78 78 78 78 78 78' 78 Heating (WD) AM 66 66 66 66 66 ' �68 68 68 68 68 68 68 PM 68 68 68 68 68 ,68 68 68 68 68, 66 66 Heating (WEH) AM 66 66 66 66 66 68 - 68 68 68 68 68 .68 ' I PM 68 68 68 68 68 • 68 68 68 '68 68 66 . 66 3/23/2015 10:14 AM I I EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist. - Florida Department of Business and Professional Regulations Residential Whole Building Performance .Method F DRESS: PERMIT.#: Port St. Lucie, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections. for?full"details.. { COMPONENT SECTION SUMMARYOF REQUIREMENT(S). r. _ "CHECK Air leakage 402.4 To- be caulked, gasketed, weatherstripped or.otherwise;sealed. - Recessed lighting IC -rated as meeting ASTM E 281.Windows and A doors = 0.30 cfm/sq.ft."Testing or:visual inspection required: Fireplaces:` gasketed doors & outdoor combustion air. Most'cornlp :'envelope leakage report or visually verify Table 40242., .. Thermostat & 403.1 At least one thermostat shall be provided, for.eadh;separate heatingand controls cooling system. Where forced -air furnace is, primary" system,. programmable thermostat is required:; Heat:p..urrips;with supplemental `r: electric heat must prevent supplemental heaf4hen compressor can meet the load. Ducts 403.2.2 J, All ducts, air handlers, filter boxes and' building cavities: -which fo"'rm the primary air containment passageways `for airA stribution•systems'shall*,.' be considered ducts or plenum chambers,,shall be constructed 'and` sealed in accordance with`Section' 503':2.7;2 of this code. , 403.3.3 - Building framing cavities shall not be.used,as:supply'ducts Water heaters 403.4 Heattrap required'for verticaltpipe'risers.' Comply with efficiencies in - Table 403.4.3.2. Provide switch or.',clearly marked circuit breaker. (electric) or shutoff (gas). Circulatingsystem pipes insulated to = R-2 + accessible manual OFF switch:' Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical " ventilation ventilation systems shall not exceed'the 'm_ inimum ASHRAE 621evel'. No make-up air from attics, crawlspaces, garages or outdoors ,adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a. total horsepower"(HP).:of = 1 �& Spas HP shall have the capability of -operating at two'or more speeds. -Spas and heated pools must have viipdr4etardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required'. Gas heaters minimum thermal efficiency=78% (82% after '4/16/133.-Heat pump pool heaters minimum COP= 4.0. Coo ling/heating 403.6 Sizing calculation performed,& attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency Special verification required. . equipment occasion cooling or heating capacity, requires separate system or variable capacity system. Electric heat >1,OkW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 3/23/2015 10:14 AM I I EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6