HomeMy WebLinkAboutEPL DISPLAY CARDENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 78
The lower the EnergyPerformance Index, the more efficient the home.
,,.Port St. Lucie, FL,
1. New construction or existing
New (From Plans)
2. Single family or multiple family
Single-family
3. Number of units, if multiple family
1
4. Number of Bedrooms
4
5. Is this a worst case?
No
6. Conditioned floor area (ft2)
3638
7. Windows** Description
a. U-Factor., Sgl,U=1.07
Area .
438.67ft2
SHGC: SHGC=0.30
b. U-Factor: Sgl, U=1'.05
288.00 ft2
SHGC: SHGC=0.28
c. U-Factor: Sgl, U=0.77
136.00 ft2
SHGC: SHGC=0.22
d. U-Factor: other (see details)
68.99 ft2
SHGC: other (see details)
Area Weighted Average Overhang Depth:
8.711 ft.
Area Weighted Average SHGC:
0.284
8. Floor Types Insulation
Area
a. S'ab-On-Grade Edge Insulation R=0.0
3638.00 ft2
b. N/A R=
ft2
c. N/A R=
ft2
9. Wall Types
Insulation
Area
a. Concrete Block - Int Insul, Exterior
R=4.1
3321.00 ft2
b. Frame - Wood, Adjacent
R=11.0
325.43 ft2
c. N/A -
R=
ft2
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=38.0
3638.00 ft2
b. N/A
R=
ft2
c. N/A
R=
ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: AC 1 First Floor
6 360
b. Sup: Attic, Ret: Attic, AH: AC 1 First
Floor
6 220
12. Cooling systems
kBtu/hr
Efficiency
a. Central Unit
58.5
SEER:14.00
b. Central Unit
17.8
SEER:14.00
13. Heating systems
kBtu/hr
Efficiency
a. Electric Heat Pump
55.5
HSPF:8.00
b. Electric Heat Pump
17.6
HSPF:8.00
14. Hot water systems
a. Natural Gas
Cap: 40 gallons
EF: 0.59
b. Conservation features
None
15. Credits
Pstat
I certify) that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this Home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
BuilderjSignature:,+ r�te: 2 23 C S-
Address of New Home: 3oog M W QaaCJ4MAI City/FL Zip: PS L 3 lt9i
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
su�port staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
Yorkshire' Model
HVAC Load Calculations
for
Standard Pacific Homes
Oh
CI
RHVACWAC LoAD9
Prepared By:
Chris Wildroudt
Engineered Air LLC CACO45860
2520 N Andrews Ave Ext
Pompano Beach, FL 33064
954 974-7277
Wednesday, December 04, 2013
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Rhvac -,Residential &Light Commercial HVAC..Loads
Ehte'Software'Development, Inc;
Engineered Air; LLC
Yorkshire Model
Mallate,'FL 33063
_ Pa e 2
Project Report
_General. Pr_o'ect,lnformation
Project Title: Yorkshire Model
Designed By:. Chris Wldroudt
Project Date: 12-4-13
Client Name: Standard Pacific Homes
Colmpany Name: Engineered Air LLC CACO45860
Company Representative: Chris' Wildroudt
. Company Address: ' 2520 N Andrews Ave Ext
(30mpany City: Pompano Beach, FL 33064
Company Phone: 954 974-7277
Company Fax: 954 973-1883
®e'si' n ®ata
Reference City: West Palm Beach, Florida
Bui,lding Orientation: House faces East
Daily Temperature, Range: Medium
Labtude: 26 Degrees
Elevation: 15 ft.
Altitude Factor: 0.999
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: 45 42.23 n/a n/a 70 n%a
Suinmer: 91 78 56% 50% 75 59
Ch"d&_kfiLl NOWs
Total Building Supply CFM: 2,343 CFM Per Square ft.: 0.635
Square ft. of Room Area: 3,688 Square ft. Per Ton: 665
Volume (ft) of Cond. Space: 39,351
Buildin Loads
Total Heating Required Including Ventilation Air: 43,384 Btuh 43.384 MBH
Total Sensible Gain: 51,529 Btuh 77 %
Total Latent Gain: 15,063 Btuh 23 %
Total Cooling Required Including Ventilation Air: 66,592 Btuh 5.55 Tons (Based On Sensible + Latent)
Rhvac is an ACCA approved Manual J and Manual D computer program.
Ca`culations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
yollr design conditions.
i
SAEW CONSTRUCTION\Chris
Elite Files\Stan Pac Prado Yorkshire.rh9 Wednesday, December 04, 2013, 2:35 PM
Rh'vac
- Residential & Light�Commercial HVAC Loads
Elite Software Development, Inc.
En
sneered Air, LLC .
®
Yorkshire Model
Mal
ate, FL 33063
Page 3'
T�'.tal Building Summary Loads
Area
Sen
Lat
Sen
Totai
pmponent
Descri
lion
Qua_n,_
Loss ._
Gain
Gain
in
Lo-E
French Door:,Glazing-Low-E French Door, u-value
96
1,848
0
1,628
1,628
10.77, SHGC 0.22.
Lo-E
Fixed Glass: Glazing -Low E. Fixed Glass, u-value
46.2
460
0
600
600
10.4, SHGC 0.31 '
Lo-E
operable`. Glazing-Low-E Operable Glass, u-value
155.8
2,335
0
5,404
5,404
10.6, SHGC 0.31
Lo-E
French Door: Glazing-Low-E French Door, u-value
40
770
0
956
956
I0:,77, SHGC 0.22
Lo-E
operable: Glazing-Low-E Operable Glass, u-value
282.8
4,238
0
5,931
5,931
I0.6, SHGC 0.31
Lo-E
S G D: Glazing -Low E Sliding Glass Door, u-value
288
4,248
0
5,708
5,708
10.59, SHGC 0.32
Lo-E
Fixed Glass: Glazing=Low E Fixed Glass, u-value
22.8
229
0
296
296
J0.4,
SHGC 0.311
Door-Metal - Fiberglass Core
21.4
192
0
192
192
13A-4ocs:
Wall -Block, board insulation only, R-4 board 2389.4
8,543
0
5,569
5,569
insulation, open core, siding finish
12E-Obw:
Part -Frame, R-19 insulation in 2 x 6 stud
304.1
311
0
311
311
cavity, no board insulation, brick finish, wood studs
16D-30:
Roof/Ceiling-Under Attic with Insulation on Attic
1566
1,253
0
1,553
1,553
Floor (also use."for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark Tile,
Slate or Concrete, R-30 insulation
22A-pl:
Floor -Slab on grade, No, edge insulation, no
339
8,382
0
0
0
insulation below floor,. any floor cover, passive, light
dry soil
Subtotals for structure:
32,809
0
28,148
28,148
People:
7
2,100
1,960
4,060
Equipment:
4,700
5,100
9,800
Lighting:
1400
4,774
4,774
Ductwork:
3,905
3,230
4,638,
7,868
10tration: Winter CFM: 243, Summer CFM: 125
6,670
5,033
2,191
7,224
Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
0
0
AED Excursion:
0
0
4,718
4,718
To al Building Load Totals:
43,384
15,063
51,529
66,592
06eck Fi'
Tonal Building Supply CFM: 2,343
CFM Per
Square ft.:
0.635
Square ft. of Room Area: 3,688
Square ft. Per Ton:
665
Volume (ft3) of Cond. Space: 39,351
941101Loads
Total Heating Required Including Ventilation Air: 43,384
Btuh
43.384
MBH
To al Sensible Gain: 51,529
Btuh
77
%
To al Latent Gain: - 15,063
Btuh
23
%
To al Cooling Required Including Ventilation Air: 66,592
Btuh "
5.55
Tons (Based On Sensible
+ Latent)
Nofesjig!
:jji1:1ijmii1�s11j1
Rhj
ac is an ACCA approved Manual J and Manual D computer program.
Calculations
are performed per ACCA Manual J 8th Edition, Version 2, and
ACCA Manual D.
All
Computed results are estimates as building use and weather may vary.
Be
I(sure to select a unit that meets both sensible and latent loads
according
to the manufacturer's
performance data at
your
design conditions.
S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Prado Yorkshire.rh9 Wednesday,.December 04, 2013, 2:35 PM
Rhvac -Residential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Engineered Air, LLC
®
, Yorkshire Model
Mar ate, FL 33063
Pa a 4.
y Loads
System 1 AC 1 -'First. Floor SuMmar
Component
Area
Sen
�JJJJWSen
ffi
Total
IDN' PiJ-5-511 MWWOan,
Loss
Gain
Gain
Gain
Lo-E French,Door: Glazing-Low-E French Door, u-value
96
1,848
0
1,628
1,628
0.77, SHGC 0:22
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
46.2
460
0
600'
600
0.4, SHGC 0.31
Lo-E operable: Glazing-Low-E Operable Glass, u-value
155.8
, 2,335
0
5,404
5,404
0.6,, SHGC 0.31
Lo-E French Door: Glazing-Low-E French Door, u-value
40
770 '
0.
956
956
j0.77, SHGC 0.22
-
Lo-E operable: Glazing-Low-E Operable Glass, u-value
148.8
2,230
0
2,404
2,404
10.6, SHGC 0.31
Lo-E S G D: Glazing -Low E Sliding Glass Door, u-value
288
4,248
0
5,708
5,708
10.59, SHGC 0.32
11J, Door -Metal - Fiberglass Core
21.4
192
0
192
192
13A-4ocs: Wall -Block, board insulation only, R-4 board 1756.6'
6,280
0
4,095
4,095
linsulation, open core, siding finish
12E-0bw: Part -Frame, R-19 insulation in 2 x 6 stud
128
131
0
131
131
'cavity, no board insulation, brick finish, wood studs
16D-30: Roof/Ceiling-Under Attic with Insulation on Attic
697
558
0
691
691
Floor (also use for Knee -Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark Tile,
Slate or Concrete, R-30.insulation
22AI-pl: Floor -Slab on grade, No edge insulation, no
248
6,132
0
0
0
!insulation below floor, any floor cover, passive, light
dry soil
_
Su totals for structure:
25,184
0
21,809
21,809
People:
5
1,500
1,400
2,900
Equipment:
4,000
3,500
7,500
Lighting:
1000
3,410
3,410
Ductwork:
2,995
924
3,536
4,460
Infiltration: Winter CFM: 185, Summer CFM: 95
5,098
3,847
1,675
5,522
Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
0
0
AED Excursion:
0
0
3,954
3,954
System 1 AC 1 - First Floor Load Totals:
i
33,277
10,271
39,283
49,555
Check Fi ures
Supply CFM: 1,787
CFM Per Square ft.:
0.634
Square ft. of Room Area: 2,819
Square ft.
Per Ton:
683
Volume (ft3) of Cond. Space: 30,079
S, stem loads
Total Heating Required Including Ventilation Air: 33,277
Btuh
33.277
MBH
Total Sensible Gain: 39,283
Btuh
79
%
Total Latent Gain: 10,271
Btuh
21
%
Total Cooling Required Including Ventilation Air: 49,555
Btuh
4.13
Tons (Based On Sensible + Latent)
Nofes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version
2, and
ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads
according
to the manufacturer's performance data
at
your design conditions.
S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Prado Yorkshire.rh9 Wednesday, December 04, 2013, 2:35 PM
Rhvac -Residential & Light Commercial HVAC Loads , Elite Software Develo ment, Inc.
.Engineered Air, LLC - Yorkshire Model
®%
Mar` ate,, FL 33063 _ Page 5
System ZAC 2. -_Second ,Floor Summary Loads '
Compo"Went "'` y Area Sen+ ' ' ' Lat S' n T=otal
=.
Quan Gain Gain, Gam
Lo-E operable: Glazing-Low-E Operable Glass, u-value 134 2,008 0 3,527 3,527
j0.6, SHGC 0.31
Lo-E Fixed Glass: Glazing: -Low E.Fixed Glass, u-value 22.8 229 0 296 296
�0.4, SHGC 0.31
13 14ocs: Wall -Block, board insulation only, R-4 board 632.7 2,263 0 1,474 1,474
insulation, open core, siding finish
12Obw: Part -Frame, R-19 insulation' in 2 x 6 stud 176.1 180 ' 0 180 180
cavity, no board insulation, brick finish, wood studs
D 16-30: Roof/Ceiling-Under Attic with Insulation on Attic 869 695 0 862 862
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark Tile,
Slate or Concrete, R-30 insulation '
22 pl: Floor -Slab on grade, No edge insulation, no 91 2,250 0 0 0
insulation,,below floor, any floor cover, passive, light
dry soil
Subtotals for structure: 7,626 0 6,339 6,339
People: 2 600 560 1,160
Eq y ipment: 700 1,600 2,300
Lig� ting: 400 1,364 1,364
Ductwork: 910 2,306 1,102 3,408
Infiltration: Winter CFM: 57,.Summer CFM: 29 1,572 1,186 516 1,702
Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0
AEp Excursion: 0 0 764 764
Syit AC C 2 - Second Floor Load Totals: 10,107 4,792 12,245 17,037
4
Supply CFM: 557 CFM Per Square ft.: 0.641
Square ft. of Room Area: 869 Square ft. Per Ton:" 612
Volume (ft3) of Cond. Space: 9,272
$stemLoads,
a- � x. :SFa ..9.�> ,��i .�, _, _7%. .:�15.�a, ?� r ^H, �};r�+s�<.„� ..x � sK�',,3a:...., ;Pt .3'�.,4%�k .t.7S�r+.•v;.�ar�FS'�:^;.z. Pam.
Total Heating Required Including Ventilation Air: 10,107 Btuh 10.107 MBH
Total Sensible Gain: 12,245 Btuh 72 %
Total Latent Gain: 4,792 Btuh 28 %-
Total Cooling Required Including Ventilation Air: 17,037 Btuh 1.42 Tons (Based On Sensible + Latent)
rNote,� .. �yyy _ N !:w,.,t `° 5 "-g:•VPC-'�, r'<s,. *a" + 40 - 4 11"..
S 4,'v;. `4. T. Y.�° YES f�Yit ..�.� � �.✓�"H � ilse�n *?%e tml . iKY s.%x.� ,vine J,
Rhvac
is an ACCA approved. Manual J and Manual D computer program.
Calculations
are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All
computed results are estimates as building use and weather may vary.
Be
sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your
design conditions.
S:\N'EW CONSTRUCTION\Chris
Elite Files\.Stan Pac Prado Yorkshire.rh9 Wednesday, December 04, 2013, 2:35 PM