Loading...
HomeMy WebLinkAboutTRUSS PAPERWORKs� A INA-1 ROOF TRUSSES A FL.OFJDA. C.ORPORAnON Important Notes / Please Review Prior to Truss Installation: 1) Trusses are to be handled, installed and braced in accordance with the following standards: ANSI/TIP 1-2007; WTCA 1-1995 —"Standard Responsibilities in the Design Process Involving Metal Plate Connected Wood Trusses", and "BCSI 1-03 Guide to Good Practice For Handling, Installing, & Bracing of Metal Plate Connected Wood Trusses" published by WTCA and Truss Plate Institute. Any of this material can be obtained by contacting A-1 Roof Trusses. Spanish versions are also available. i 2) All temporary and permanent bracing design, connection, material, and labor by others. 3) Truss designs are for an individual component, not for a truss system. Reactions and uplifts may vary from building designers calculated loads. The building designer is ultimately responsible for clarifying any discrepancies. 4) If provided by truss manufacturer, any engineered beams provided have been sized using information design guides or software provided by the beam manufacturer. The building designer should verify all loads uplifts, and bearing requirements. Truss manufacturer is not responsible for specifying beams, other than those provided by truss manufacturer. 5) Unless specified, roof trusses are not designed for any additional attic storage loads. 6) On flat surfaces, adequate drainage must be provided to avoid ponding. 7) It is the builder's responsibility to assure there is adequate room for A/C ducts, electrical wiring and plumbing runs to assure they do not interfere with the truss chords. (Roof and floor:) Truss chords and webs cannot be art. Attic access opening should be located between trusses unless otherwise noted. 8) Unless specified, valley framing design, connection, material and labor to be supplied by the builder. 9) Attached drawings are standard details that cover most installation standards. Structural details provided by the building designer supersede any attached details. 10) Trusses are not designed to carry the chimney, cupola, steeple, or other structures unless specified. Structure should be framed through the trusses to be supported by the foundation. In cases where trusses are designed to carry the structure above all loads and uplifts MUST be verified by building designer. Connection of structure to trusses must, be provided by the building designer. 1 1) The specific engineered truss drawings are subject to other terms, conditions, and details on the truss placement plan and/or individual truss design drawings. 12) Trusses are designed to carry ONLY the specified loads on the engineered drawings. Point loads for materials, erection personnel, equipment, whether temporary or permanent, are -not allowed unless specified on sealed engineered drawings. Any questions or comments feel free to contact A-1 Roof Trusses at 772-409-1010. 4451 St. Lucie Blvd., Fort Pierce, FL 34946 772-409-1010 Office 772-409-1015 Fax www.AItruss.com Name., us P - Address: P4STRUCTURAL CONNECTORS' customer., k' Company Contact: Hangers, Number. iv . - 6A. TMAZMN j Pi M• N q 4"PI M I.F. •V v qeT U .A _ fidpo !i IN 5 Fa T1 JUS24 1881 655 750 820 510 4- 10d (Header) F1.821,39, 2 - lod (Joist) 0510.01, RR 25779 LUS24 670 765 825 490 4-10d (Header) 12 - lod (Joist) T2 JUS26 Iasi, 850 975 1060 1115 4-10d (Header) FL$21.4Z 4 -10d (Joist) 11- 0510.01, RR 25779 LUS26 665 990 1070 j16.5 4 - 10d (Header) I I 1 4 - 10d (Joist) T3 MSH422 183:4 - - - 22 - 10d (Face - Face Max Nailing) F1.822.36, 6 -10d (Face - Top Max Nailing) us- 6 - 10d (Joist - Face Max Nailing) 0303,06, 6 - 10d (Joist - Top M ax Nailing) RR 25836, 4-10d (Top -Top Max Nailing) 13116-R THA422 2245 2245 2245 6- 16d (Carded Member- Face Mount) 6- lad (Conled Member - Top Flange) 22 -16d(Face - Face Mount) 2 - 16d (Face - Top flange) 4 - 16d (rap - Top Flange) TT W422 1835 1835 1835 2- 10dx1-112 or2 -10d x 1-112(Carried Member) 20 - 10d or2 - lod (Face) .4 -10d (Top) �fflllllll USP Structural Connectors 1�� T4 TH D26 1781, 2485 2855 3060 2170 - 18 -16d (Face) FL13285.35 12 -10d x 1-1/2 (Joist) , 06- 0921.05, RR 25843 HTU26 2940 3340 3600 1555 11 -10d x 1-112 (Carried Member) 20 -10d x 1-112 (Carried Member - Max Nailing) 20 -16d (Carrying Member) 20 -16d (Carrying Member- Max Nailing) T5 . TH D26-2 1781. 2540 2920 3175 2285 - 18 - 16d (Face) FL13285.35 1.2 -10d (Joist) , 06- 0921.05, RR 25843, 13116-R HHU526--2 2785 3155 3405 1550 14 -16d (Face) 6-16d (Jaist) HrU26-2 2940 3340 3900 2175 - 20 - led (Carried Member - Max Nailing) 20 -16d (Carrying Member- Mox.Nailing) T6 THD28 1781. 3865 3965 3965 2330 - 28.16d (Face) FL13285.35 16 - 10d x 1-1/2 (Jaist) , 06- 0921.05, RR 25843 HTU28 3820 4340 4680 2I40 26 -10d x 1-112 (Carried Member - Max Nailing) 26 -16d (Carrying Member- Max Nolft) T7 THD28-2 17U 3950 4540 4935 2595 - - 28 - 16d (Face) FL13285.35 16 -10d (Joist) , 06- 0921.05, RR 25843, .13116-R HHUS28.2 4210 4770 5140 2000 22 -16d (Face) 8 -16d (Joist) HTU28-2 3820 4340 4680 3485 - 26 - lod (Corded Member - Max Nailing) 26 - I6d (Carrying Member- Max Nailing) T8 TH D46 178:4 2540 2920 3175 2285 - - 18 - 16d (Face) FL13285.35 12 -10d (Joist) '06- 0921.05, - -RR 25843,- , -- - -- - — - — - - - - 13116-11 USP Structural Connectors HHUS46 2790 3160 3410 1550 - 14 -16d (Face) T9 THD4B 1781, 3950 4540 4935 2595 28 - 16d (Face) FL19285.35 16 - 10d (Joist) 092i.05, RR 25843, 13116-R HHUS48 42I0 4770 5140 2000 - 22 -16d (Face) 8-16d (Joist) T10 TH DH26-2 1881, 3915 45505 4795 2235 20 -16d (Face) FL821.75, 8- 16d (Joist) 06- 0921.05, RR 257T9, 13116-R HGUS26-2 4355 4875 5230 2155 - - 20 -16d (Face) a -16d (Joist) T11 THDH26-3 1881, 391.5 4505 4795 2235 20 -16d (Face) FL821.75, 8 - 16d (Joist) 06- 0921.05, RR 25779 HGUS26-3 4355 4875 5230 2155 - 20 -16d (Face) 8.16d (Joist) T12 THDH28-2 1881, 6535 7515 8025 2665 36 -16d (Face) FL82L77, 10 -16d (Joist) RR 25779, 13116-R HGUS28-2 7460 7460 7460 3235 36 -16d (Face) 12 -16d (Joist) T13 THDH28-3 1884 6770 7785 8025 2665 - - - 36-16d (Face) FL821.77, 12 - 16d (Joist) 06- 0921.05, RR 25779 HGUS28-3 7460 7460 7460 3235 - - 36 -16d (Face) 12 -16d (Joist) USP Structural Connectors Im Name; - ^4Ot, U vs P Address; STRUCTURAL + CONNECTORS' Customer. AN nek* -ccmpaw Contact: Number. Fastener'Comparlson Table _i- v ='a. e.�'••Y�,�ii _'f' 2y�`-b-�T.r';':['_-�_�t� -�' L�:?�ifL�':'-.t: \:fees^ i'i-.•;i.. _•?'. �lt;;:rw-.o �-�i?'4^� - .-�i.•.:y^-., — ',�i •i_..=r_'---✓'%��..-^_ : ;3wF�' .ems-:r_---• S."�3-+;...- a...— ,,,?� �. �chedaFe-Q`•��=�=:;- - _�.-.✓Y. w�LE.l:�=•-,fit-tir. _ �'��S"S- �s.:rn"1=•-%.?cit!/.ivriM�sV��v.'."_':]. ti�v.�a�.� ..^i-a.1�^�-r - .. 4�L.�.�--^t..A-Vie..-" �La.-rs"w-. ��%tc•��ui2G+=� c%:."5:..-�'_+=ina��w�'_�..�=�.r.-^_bra-.�_iv_.v_: - 6ro ��V� _ =EISPiStock: - _-uh�cti�^-v.-,:a. ..`-'v' �"R ^ems Y'•-�• eren :N �>�,�_ � - -`'• - - - - - - - -- -`'� �'f�'-' - - �` ..4����rRequtrad�Fasterrers���r �. - T1 JUS24 4-10d (Header) LUS24 4-10d (Header} 2 -10d (Joist) 2-10d (Joist} - T10 THDH26-2 20 -16d (Face) HGUS2&2 20-16d (Face) 8 -16d (Joist) 8-16d (Joist) - T31 THDH26-3 20 -16d (Face) HGUS2&3 20-16d (Face) 8 -16d (Joist) 8 -16d (Joist] - T12 THDH28-2 36-16d(Face) HGUS282 36-16d(Face) 10 -16d (Joist) 12 -16d (Joist) - T3.3 THDH28-3 36-16d(Face) UGUS28--3 36-16d(Face) 12 -16d (Joist) ) 12 -16d (Joist} - T2 JUS26 4 -10d (Header) LUS26 4-10d (Header) 4 -10d (Joist) 4 -10d (Joist) - T3 MSH422 22-10d (Face - Face Max Nailing) THA422 6-16d (Carried Member- Face Moun(l 6 -10d (Face -Top Max Nailing) 6-10d (Carried Member - Top Flange) 6 -10d (Joist - Face Max Nailing) 22-16d (Face - Face Mount) 6 -10d (lolst -Top Max Nailing) 1-16d (Face - Top Flange) 4 - lOd (Top -Tap Max Nailing) 4-16d (fop - Top Range) - T4 THD26 18 -16d (Face) HTU26 II - IOdx 1-.Z12 (Carried Member) 22 -1od x 1-i/2 (Joist) 10 - IDd x I-12 (Carried Member - Max Nailing) 20 -16d (Carryfng Member) 20 -16d (Carrying Member - Max Nailing) - TS T HD26-2 18 -16d (Face) HHUS26-2 14 -16d (Face) 12 -10d (Joist) 6-16d (Joist) - T6 THD28 28 -16d (Face) HTU29 26 - Wd x 1-12 (Carried Member - 16 -10d x 1-1/2 (Joist) Max Nailing) 26 -16d (Carrying Member - Max Nailing) T7 THD28-2 28 -16d (Face) HHUS28 2 22 -16d (Face) 16 -10d (Joist) 8 -16d (Joist) - T8 THD46 18 -16d (Face) HHUS46 14-16d(race) 12 -10d (Joist) 6-16d (Joist) - T9 THD48 28-16d(Face) 77NNUS48 22-I6d(Face) I 116 -10d (Joist) 8 -16d (Joist) USP Structural Connectors j ec us P Address; STRUCTURAL CONNECTORS Customer. A Mirek7 Company Contact: Pq 5 3_. JUS24 THDH28-2 ?: P W 1 3 9hG'� MSH422 THD28 Number. - WMMF�:�-- (Qty. 1) THDH28-3 (Qty. 1) THD26 Left,3 flange a `:� F � ,N; Y (Qty. 1) 1 THD28-2 (Qty.- 1) 1 THDH26-3 (Qty.-1) JUS26 L t flange (Qty-1) THD26-2 Left flange ght flange (W.-1) 1 THD46 (Qv. 1z ht flange • I P ght 3nge, 2V!1) USP Structural Connectors JIM 1' Address: STRUCTURAL Customer_ CONNECTORS` AMTek'Company Contact Leif flange I CM 8ht flange (QtY' Number. USP Structural Connectors i 113OK14 aO1oXsE5mg1bM Ws 4- hR •2-945 - 9 -- - 0 13 e 2915 54A TYPICAL HIPJACK CONNECTION TSTBK MAX 55 PSF MAX ROOF LOAD mum 170 MPH EX C H=26 MAX "A'13 4 24 to 2. 72 N$1LE0 3x4 NAILM 3 12 4i4EID T1 MLM 11 all comerjack ,ry With 2-i6d the miIsTCC-C t, p. 1: d 81 C k 14 15 7 is a ° UVLED AILM HAILED1 Rux:lj - NAILED NAIM NAILSD 15d toe nail4 24- slump 6-1 od:1.5- each end r ewe ys<� R a Plate Offsets X : LOADING (p-f) SPACING 2 D-0 CS1 OP_FL in (hoc) Well Lid PLATES GRIP ' TCLL 30.0 Plates Increase 125 TC 0.71 Vert(LL) -13M 6 7 >999 350 MTZD 244119D TCDL 15.0 Lumber Increase 125 BC D-49 Vert(TL) -0.09 6-7 >999 P-40 BCLL 0.0 ' Rep Stress Inc NO WS 0.50 Hoe(il) 0.01 6 nra nia SCOL 10.0 CodaFRC2010rTP12M7 (Matrix M) Weighe441b FT - 0-1 CHORD 2x4 SYP t.4 3B CHORD 2�;4 SP N0.2 S 2x4 SP No.3 BRACING TOP CHORD Structural rood sheathing directiyapplied or 5-0.0 cc purtins. SOT CHORD Structural mood sheathng d'uectiy applied or B-94 or: bracing. KTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in aa:ord?m:e tdth Stabifi2ir CTIONS pbTsize) 4-IM*rVlechanlcal,2-608*10-i5 (min.0-1-8).6-350WILchanical Max Horz2-308(LC 4) Max Up5ft4--156(LC 4). 2,-362(LC 4), 6--159(LC 6) Max Grv4-219(LC 2). 2-734(LC 4 5-41MC 2) CES (Ib) - Max. CompjWlam Ten. -AN forces 250 (ib) or less a=ept when sholcn. CHORD 2-11--933i645, 11-12--656307, 3-12--84Si303 CHORD 214--ol/846.14-15--i39f848,7-15—l39tS4B.7-16--4391846.6-t6--432" IS 3-6-9161-175 1) Wind: ASGE 7 10;170mph (3-second gust) Vasd-132mph; TOOL-S.Opsf; BCDL-5.0pst; h-25h; Cs. It; Exp C; Ens., GCpWL18; MWFRS (envelope); cantilever left and right exposed; Lumber DOL-1.33 plate grip DOL-1.33 2) This Miss is not designed to support a ceiling and is not Intended for use where aesthetics are a consideration. 3) Plates checlred for a plus or ninus 0 degree rotation about Itscenter. 4) This buss has been designed fora 10.0 psf botlorn chord five load nonconcurrent with any other live loads. 5)' TWs truss hs bcen designed fnr a Eve load of 20.0psf on the bottor a chord In all areas wherea rect2ngl a 3-&0 fall by 2-D-0 wide bill fit between the bottom chord and arry other members. ``llllll(It�f�' ' N 34869 _lr ='O �QU _ �� .. STATE OF�� s"ONA\- 111l1ti11111�� 1109 COASTAL BAY BOYNTON BC,FL 33435 10120/12 TYPICAL ALTERNATE BRACING DETAIL -FOR EXTERIOR FLAB GIRDER TRUSS 12 TRUSS -24' c.c. UPLIFT CONNECTION, SEE ROOF TRUSS EXTERIOR FLAT GIRDER 0 4 12d MAX 30°' (,21 - 5" ) xa #2 Sp BOTH FACES ��,•• ti;cErvs�•••� r, 24 et N 34869 �• =�Q Y �� I M Pra' �N H =,° • • STATE OF ,•� `��, r.011 ANAL►�� �`� 1109 COASTAL BAY BOYNTON BG,FL 33435 10/29/12 STANDARD PIGGYBACK'1-RUSS rFEBRUARY 14, 2D12F CONNECTION DETAIL (PERPENDICULAR} ST PIGGY PERP. o � O UVL -U] MiTek Industries, Inc. DETAIL IS NOT APPLICABLE FOR TRUSSES TRANSFERING DRAG LOADS (SHEAR TRUSSES ADDITIONAL CONSIDERATIONS BY BUILDING ENGINEERIDESIGNER ARE REQUIRED. PIGGY -BACK TRUSS (CROSS-SECTION VIEW) Referto actual truss design drawingfor additional piggyback truss information. NEAR SIDE tWTek hmUS ies. Chesteff1Wd, MO Page 1 of 1 MAX MEAN ROOF HEIGHT=30 FEET BUILDING CATEGORY 11 WIND EXPOSURE B or C WIND DESIGN PERASCE 7-98, ASCE 7-02, ASCE 7-08100 MPH (MWFRS) WIND DESIGN PER ASCE 7-10125 MPH (MWFRS) DURATION OF LOAD INCREASE FOR WIND LOADS:1.60 THIS DETAIL SHALL BE ONLY USED FOR RESISTING A VERTICAL WIND UPLIFT UP TO 190 LBS IdIAXIMUMAT EACH CONNECTION POINT. BUILDING DESIGNER IS RESPONSIBLE FOR THE LOAD EXCEEDING THIS LIMITATION AND10R IN OTHER DIRECTIONS. ATTACH PIGGYSACKTRUSS TO BASE TRUSS WITH (2) -16d (0.131" X3.Bj NAILS TOENAILED. FAR SIDE NOTES FOR TRUSS: I. 2. FLATTOP CHORD OF BASE TRUSS BASE TRUSS (SIDE VIEW) Refer to actual truss design drawing for additional base truss Information. NOTES FORTOE-NAIL: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGREES WITHTHE MEtMER AND STARTED 113 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN: 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. THIS DETAIL IS VALID FOR ONE -PLY PIGGYBACK TRUSS ONLY: THE CHORD MEMBER OF PIGGYBACK AND BASE TRUSSES MUST BE SOUTHERN PINE OR DOUGLAS FIR -LARCH LUMBER: THE SPACING OF PIGGYBACK TRUSSES AND BASE TRUSSES IS 2 FT OR LESS; THE PIGGYBACKTRUSSES SHOULD BE PERPENDICULARTO BASE TRUSSES. PIGGYBACK TRUSS MAY NOT CANTILEVER OVER BASE TRUSS OR HAVE AN OVERHANG WHICH WILL CREATE A HIGHER UPLIFT AT CONNECTING POINT. xN134869b.0 � : ]0 L U Z STATE OF _ w` 1109 COASTAL BAY BOYNTON BC,FL 33435 '10/19/12 1 14, 2012 I Standard Gable End Detail SHEET 2 - ® MTek Industries, Cheaeri'wK MO Page 2 of 2 ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD II IL I Trusses Cal 247 ox. o� HORVONTAL BRACE 2YE DIAGONALBRACE SPACED 48- O.C. (SEE SECTION A A) ATTACHED TO VERTICAL WITH ') -16d COMMON WIRE NAILS AND ATTACHED MITek Industries, Inc. Roof Sheathin , TO BLOCKING WITH (s) -10d COMni(INS. t V-3' SPO,4SIBIUiYOFTHEBLDGDESIGNEROfl j IRACETO CT ENGINEER)ARCHTECTTODESIGN THE A AGON NAB DIAGONAL LDI GONI LB 1PHRAGMAND ITS ATTACHMENTTOTHE -PURLIN76dNAILS O RESISTALL OUT OF PLANE LOADS THAT TFROM THE BRACING OFTHE GABLE ENDS 2X4PURLIN FASTENED TO FOUR TRUSSES WITH TWO I6d NAILS EACH- FASTEN PURUN i \ TO BLOCKNG W1n-JO 15d NAILS.(MIN) Diag. Brace at113poi nts , �� \ PROV0DE2x4BLOCI.9NG.BETWEENTHETRUSSES SUPPORTING THE BRACE AND THETWOTRUSSES if needed ON EITHER SIDE AS NOTED. TOENAIL BLOCKING TRUSSES TO ILS AT EACH END. ( ToBLOCWNG ATTDIAGOI A BRACE WITH (5} -10d COMMON WIRE NAILS. End Wall :��-. - �•-_ CHUNG SHEATHING BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRU Ci UR4L GABLE TRUSSES MAY BE BRACED AS NOTED: METHOD 1 : ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE OF THE S1 RUC TURAL GABLE AND FASTEN PER THE FOLLOWING NAILING SCHEDULE METHOD2:ATTACH2X SCABSTOTHEFACEOFEACHVEFMCAL MEMBER Ot�THE STRUCTURAL GABLE PER THE FOLLOWING NAILING SCHEDULE. SCABS ARETO BE OF THE SAME SIZE. GRADE AND SPECIES AS THE TRUSS VERTICALS NAILING SCHEDULE: • FOR WIND SPEEDS 120 MPH (ASCE 7-S8. 02, 05),150 MPH (ASCE 7-10) OR LESS, NAILALL MEMBERS WITH ONE ROW OF 10d (.731- X X) NAILS SPACED 6- 0.0. - FOR W IND SPEEDS GREATER 120 MPH (ASCE 7-58, 02, 0!% 150 MPH (ASCE 7.10) NAB. ALL MEMBERS WITH TWO ROWS OF 10d 031- X 37 NAILS SPACED 9- O.C. (2X 4 STUDS MINIMUM) M14XIMUM STUD LENGTHS ARE LISTED C ALL BRACING METHODS SHOWN ON PA( / VAUDANDARETOBEFASTENEDTOTHESCABSOR INLAYEDSTUD VERTICAL STUDS OFTHE STANDARD GABLE TRUSS ON THE INTERIOR SIDE OFTHE STRUCTURE. fAN ADEQUATE DIAPHRAGM OR OTHER METROq Q�j CING MUST STRUCTURAL BE PRESENT TO PROVIDE FULLLATERAL fNRpORf BOTTOM GAOLETRUSS / CHOROTORESISTALLOUTOFPLANE 'dA E ING•$IjOWN INTHIS DETAIL IS FORTHE VERTICLI()x . y. �j� NOTE :THIS DETAIL IS TO BE USm ONLY FOR :. N 34869 • . STRUCTURAL GABLES W TIH INLAYED S UDS.TRUSSESWITHOUTINLAYED I � - rt STUDS ARE NQTADDRESSED HERE 0 1 LIJ_ I _ 0. STATE OF ._f� STANDARD ' '�� :fiLORION GABLETRUSs / Jtttlll{IIi1\� 1109 COASTAL BAY BOYNTON BC,FL 3343E M STANDARD PICAYETACK I FEBRUARY 14, 2U12 I TRUSS CONNECTION DETAIL I ST; PIGGY PLATE I I� LJIJ O moo �� 00 a MI i ek Induslries, Inc. This detail is applicable for the following wind conditions: ASCE 7-98, ASCE 7-02, ASCE 7-05, ASCE 7-10 Wind Standards under ap enclosure and exposure conditions as long as no uplift exceeds 377 lbs. Refer to actual piggyback truss design drawing for upt. NOTE: This Detail is valid for one ply trusses spaced 24' o c. or less. PIGGYBACKTRUSS fiefer to actual truss design drawing fcr additional piggyback truss information. SPACE PURLINS ACCORDING TO THE MAMMUM SPACING ONTHE TOP CHORD DFTHE BASE TRUSS (SPACING MDT TO EXCEED W O.C.Q. A PURUN TO BE LOCATED AT EACH BASE TRUSS JOINIE MTek Industries, Chesw&wd, MD Page 1 of 1 Attach piggyback truss to the base truss with 3"xe' TEE -LOCK Multi -Use connection plates spaced 48" o.c. Plates shall be pressed into the piggyback truss at 48' o.c. staggered from each face and nailed to the base truss with four (4)- 6d (t TxO-099") i nails in each plate to achieve a maximum uplift capacity of 377 lbs. at each 3"x8' TEE -LOCK Multi -Use connection plate. i (Minimum of 2 plates) _ Attach each puriin to the top chord of the base truss. (Purlins and connection by others) BASE TRUSS Refer to actual truss design drawing for additional base truss information. N 34869 --U) rY� -� 03 Luz:a • STATE OF �� "'CORVDN --' Cj�� A%- 1109 COASTAL BAY BOYNTON BC,FL 33435 10/19/12 FEB RUARY 14, 2012 EMIED zoo UPI MiTeklindustries, Inc. RE VALLEY TRUSS IE ROW OF 16d 6' O.C. . TRUSSED VALLEY SET DETAIL I ST VALLEY SYP [. of— GA5LE END. COh•61r1ON TRUSS OR GODERTRUSS Mirek Industries, Cheshe fizid. Mo Page 1 Oi 1 GENERAL SPECIFICATIONS 1. NAIL SIZE = 3.5' X 0.131"=16d 2. INSTALL VALLEYTRUSSES (24- O.G MAXIMUM) AND SECURE PER DETAILA 3. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS_ 4. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EOUILIVANTTO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. S. NAILING DONE PER NDS - Di S. VALLEY STUD SPACING NOT TO EXCEED 43' Q.C. 7. ALL LUMBER SPECIES TO BE SYP. GABLE END. COMMON TRUSS OR GIRDER TRUSS WIND DESIGN PER ASCE 7-95. ASCE 7-02. ASCE 7.05 12D MPH / WIND DESIGN PER ASCE7-1Q 15D MPH ATTACH 2x4 CONTINUOUS N0.2 SYP MAX ROOF PITCH ROOF ITCHMINIMUMf2 MAXIMUM 1GA2 TO THE ROOF W/TWO 16d (0.131- X 3.5") NAILS CATEGORY It BUILDING INTO EACH BASE TRUSS. EXPOSURE C OR B WIND DURATION OF LOAD INCREASE : 11EDI I 1 I MAXTOPCHORDTOTALLOAD-Gp%W /I!! MAX SPACING - 2V O.C. (BAS1;-A)1Q�V��, MINIMUM REDUCED DEAD `O D FtvLT19F- •.: ��� ON THE TRUSSES �? AIL A KIMUM 1" SHEATHING) .T.S. # • N 34869 ' �' 1D 19/lz w� STATE OF 1109 COASTAL BAY BOYNTON BC,FL 33435 a•, OCTOBER 1. 2006 iJ a MTek Industries, Inc. Z O is M 1tD z 0 Z4 cfi VALUES SHOM AF—;= CAPACITY PER TOE -NAIL APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED v LATERAL TOE -NAIL DETAIL I ST TOENAIL SP MTekln&mtries,Chestwfleld,MO Page 1 oF1 NOTES: I. TOE I4MLS SHALL BE DRIVEN AT AN ANGLE OF 45 DEGREES WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT. (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN. ? THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOI D UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OFTHETWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. wTOE-NAIL SINGLE SHEAR VALUES PER NDS 2001 (ibinail) SYPI DF HF SPF SPF-S .131 BB.O 00.6 69.9 MA 59.7 •135 93Z 056 74.2 726 63.4 .162 108.9 99.6 SBA, 64.5 7313 .128 74-7 67.9 50.9 57.6 503 .131 75.9 59.5 603 59.0 51.1 .148 H7 4 74.5 64.6 1 631 52S EXAMPLE. (3)-16d NAILS (.162" crmm.x 3S I WITH SPF SPECIES BOTTOM CHORD Forluad duration increase of 1.15: 3 (nails) X 84.5 (Ib/nail) X 1.15 (DOL) = 291.5lb Maximum Capacity ANGLE MAY VARY FROM 30' TO 50' 45.00' ANGLE MAY VARY FROM 30° TO 60° THIS DETAIL APPLICABLE TO THE THREE END DETAILS SHOWN BELOW VIEVS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY SIDE VIEW (2Ga, 2^4) 2 MLS NEAR SIDE NEAR SIDE 45.00° SIDE NEW (2"b7N.41 3 LS x x NEAR SIDE NEAR SIDE NEAR SIDE ANGLE MAY I VARYFROM30° TO 60° I 45.00° `,�11t1It111����r i �`�♦�J��vs Etv F N M869 Eli `p'• 10/1s/3.2 STATE OF 1109 COASTAL BAY BOYNTON BC,FL 33435 ER 1, 2006 � ' ^ LJL I 0 00 a od � a MTeli Industries, Inc. SIDE VIEW NEAR i I FAR.. SIDE UPLIFT TCR&NA - DETAIL . I ST-TOENAIL UPLIF MI-rak Industries, Chesterfield. MO ' Page T of 1 NOTES: 1. TOE NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGREES WITH THE MEMBER AND START ED 113 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER. VALUE OF THE BOTTOM CHORD SPECIES OR TOP PLATE SPECIES FOR MEMBERS OF DIFFERENT SPECIES. TOI OF VIERS SHOWN ARE FOR ILWSTRAl1GN PURPOSES ONLY TOE -NAIL WITHDRAWAL VALUES PER NDS 2001 (Ib/nail) CWV1. I S(P DF HF SPF SPF S O 131 59.5 45.1 1 31.6 29.9 20.3 J135 I 60.3 47.5 I 32.6 30.7 209 in .162 I 72.3 57A 39.1 35.9 25.1 ai z .128 53.1 419 29.7 27.0 18A OJ 131 543 429 293 27.7 18B N 148 51A 4B_3 332 31.3 21,3 m 0 .120 45.9 �4 Z3.4 159 O Al s 49.11 38.6 26.5 25A 17-0 o .1,31 50.1 1 38.5 27.1 25.5 17.4 .143 55.6 4q 6 30.6 26.9 19.6 VALUES SHOW4 ARE CAPACITY PERT01= NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) -16d NAILS (.162" diam. x 3.5") WITH SPF SPECIES TOP PLATE ForlM1ind DOL of 1.33: 3 (naifs)�X36.8 (Ibinail)X 1.33 (DOL forwind) = 146.81b Maximum Allowable Uplift Reaction Oua To Wind For'vMnd DOL of 1.60: 3 (nails)X 36.6 (lb/naa)X 1.60 (DOL for wind)=176.61b Maximum Allowable UpGftReaction Due To Wind If the upl'ili reaction specified on the Truss Design Drawing (s more than 145.8 lbs (176.5 Ibs) another mechanical uplift connection must be used. USE (3) TOENAILS ON 2A BEARING WALL USE (4) TOENAILS ON 26 BEARING WALL END VIEW 10/19/12 111litt/7/ ` �JN." • 4�cEIvsF * ' N 34869 "FT CZ • _ STATE OF • ��� i •'• fi�ORf1�p'.-'• 1�` t� 1109 COASTAL BAY BOYNTON BC,FL 33435