HomeMy WebLinkAboutcompactionHeadquarters- - _ '
On IL ENGINEERING Mailing
I'
11345 U.S: Highway 1 PO, Box 78-1377
Sebastian, FL.32958 Z%LXA%% AND.TESTING Sebastian, EL32978
Orlando SOIL COMPACTION REPORT Phone:. 772=589-0712
723 Progress Way ASTM D 1557 and ASTM D 6938 C.A.# 5693
Sanford, FL. 32771 KSMengineering.net
DATE TESTED: May 6, 2022
KSM JOB # : 2204428-1pd/BS/KT
PERMIT #: 2107-0079
CONTRACTOR: Horizon Pools
NUC # 456
Nuc Model: MC-1 Elite
JOB LOCATION: 7907 S. Indian River
Drive
Nuc Serial #: 31456
Fort Pierce, Florida
ITEM TESTED Pool Backfill Compaction
TEST LOCATION
PEN
DRY MAX. DRY PERCENT
OF SAMPLE DEPTH
READ
DENSITY PROCTOR VALUE COMPACTION
1 North 0'-1'
40 D
108.0 112.5 96.0%
2 1'-2'
40 D
- 95.0% +
3 2'-3'
40 D
- 95.0% +
4 3'-4'
40 D
- 95.0% +
5 South 0'-1'
40 D
107.1 112.5 95.2%
6 1'-2'
40 D
- 95.0% +
7 2'-3'
40 D
- 95.0% +
8 3'-4'
40 D
- 95.0% +
9 West 0'-1'
40 D
108.4 112.5 96.4%
10 1'-2'
40 D
- " 95.0% +
11 2'-3'
40 D
- " 95.0% +
12 3'-4'
40 D
1195.0% +
Soil Description:
Brown Sand
114.0 1 1 1 1 1 1 1 1
In Place Moisture:
E 113.0I-
10.4 %
I I l I I I I
Proctor Optimum Moisture:
H 112.0 -} • • — I — l- — I — i- —i —
10.0
Proctor Max. Dry Density: P.C.F.
T 111.0 I —
112.5
@ Test Locations the Density &
P
110.0 �— -� — •I. L_ .. J .. _ .I. _ ..1_ .. _ .
Penetrometer reading indicate th`�t► I ��'
C I I I I I I I
Degree of Compaction Meets � G p►. 1Nfc i
109.0F
Minimum Requirement \�� ►��. �aeNs .'4��i�
I I I I
For Unplumbed Backfill �' F
I I I
108.0
Respectfully Submitted: No69841
p I I I I I I I
_
=
R 107.0 4—..4.._4._..k----4 _4.— -4.._.,
Y 5 6 7 8 9 10 11 12 13
Moisture - % of Dry Weight
;um„v Digitally sigd'�`� •, FCoREop
.• �'��` Disclaimer: Contractor is responsible to maintain the pool backfill
by Eric A McArQ. S'
,.°;;,,,,,..,.. �`s'10NAU `li?��`
in
the condition that KSM completed the indicated passed
Date: ������ IljXX
2022.05.09
compaction test. KSM is not responsible .if the poolbackfill has
12:29:46-04'00'
been
altered from the approved inspected condition.
Eric A. McAra, P.E. Office Manager
PE # 69841 5/6/2022
Email to: tkiss.horizonpools@gmail.com
Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing
Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting
Proudly Serving Florida since 1990
Certified Women Owned Business - WBE