dNOA is being issued under the applicabie-ro[tWwld-regulations governing the use of construction materials. The
ocumentation submitted has been reviewed and accepted by Miami -Dade County RER -.Product Control Section to
`7 used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall:noi'be valid after the expiration date stated below. The Miami Dade County Product Control
Section (in 1Vfami=Dade County) and/or the AHT (in areas other than Miami -Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner; the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, .or suspend the use of such product or material within their jurisdiction. RFR reserves the right
mto revoke this acceptance, if it is determined by Miami Dade County Product Control Section that this product or
aterial fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: TRI--BUILT Sand-R SA Shingle, Smooth HT S/A and S/A HT TU Underlayment Products
"ELD!G: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement. "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
injthe applicable bu ilding code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of
any for sales, advertising or any other purposes shall automaticall product
y terminate this NOA: Failure to comply with any
sec11
tion of this NOA shall be cause for termination and removal of NOA.
AbVERTISEMENT: The NOA number preceded by the words Miami --Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be
doge in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manu%ctumr or its distri-butors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages 1 through S.
The submitted documentation was reviewed by Gaspar J Rodriguez.
NOA No.:15-1123.06
Expiration Date: 09/29R0
Approval Date: 04MM6
Page 1 of 5
APPROVAL
Roofing
Underlayment
SBS
'is acceptance is for TRI-BUILT Sand-R SA Shingle, Smooth HT S/A and S/A HT TU Underlayment Products,
described in this Notice of Acceptance, for use with approved prepared roof assemblies as described in this Notice
Acceptance; designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the
nidaBuilding Code.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Prod uet Dimension Specification ' tion
i Built Sand-R SA Shingle 36" x 65' rolls ASTM D1970 Self -adhering glass fleece reinforced, SBS
derlayment modified bitumen roofing underlayment.
rnufacha ingLocation #1-3
Smooth HT S/A 36" x 65' rolls ASTM D1970 Self -adhering glass fleece reinforced,
meat elastomeric bitumen roofing underlayment.
aingLocation #1-3
S/A HT TU 39 3/a" x 65 3A' TAS 103 and Self -adhering glass fleece reinforced, SBS
went rolls ASTM D 1970 modified bitumen roofing underlayment.
wingLocation #3
LOCATION:
11. Drummondville, Quebec (Canada)
2. Wadsworth, OH
3. Gulpol% MS
EVIDENCE SUBMITTED:
Test
Underwriters Laboratories, Inc.
Trmtty ERD S40540.02.13-1
S40540.11.13
S43530.02.14-1 Rl
S44870.04.14-4
S44870.04.14-1
S44870.04.14-3
S40540.10.14
SOPC-SC8520.04.15
Test Identifier
R21824
Test NamelReeport
Date
UL790
09/11/15
ASTM D1970
02/19/13.
ASTM D1970
11/19/13
TAS 103
05/14/14
ASTM D1970
04/10/14
ASTM D1970
04/10/14
ASTM D1970
04/02/14
ASTM D1970
10/31/14
TAS 103
04/27/15
NOA No.:15-1123.06
ErPiration Date: 09ams
APproval Date: 04/28/16
Page 2 of 5
Deck Type 1i
Wood, Non -insulated
Deck.Deseription:
19/32" or greater plywood or wood plank
System E(1):
Base sheet mechanically fastened, membrane adhered.
Base Sheet:
One or more plies of ASTM D226 Type II or ASTM D2626 with a minimum 4" side lap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and
two staggered rows 12" o.c. the field of the roll.
Membrane:
One ply of Tri-Built S/A HT TU Underlayment, Tri-Built Smooth HT S/A Underlayment
or 1'&Built Sand-R SA Shingle Underlayment with minimum 3-inch side laps and 6-inch
end laps. Starting at the fast course, parallel to the eave, align the membrane carefully by
completely unrolling and setting it exactly where it will W installed. Once aligned, rewind one
half of the length Gently score the release paper on the high side of this roll, ensuring not to
cut through the membrane's thickness. Unroll this first half by evenly peeling back the release
paper while simultaneously and slowly pushing out the membrane. Repeat process for
remaining one half of the length. Once installed, the membrane must be pressure rolled with a
metal or rubber roller. Pressure shall be applied over the entire surface, paying particular
attention to all side and end laps.
Surfacing:
Approved for Mechanically Fastened Metal Roofing, Wood Shake & Shingles, Asphalt
Shingles, Slate, Simulated Slate.
� k Type 1:
Description:
Wood, Non -insulated
19/32"
Deck
or greater plywood or wood plank.
System E(2):
Base sheet mechanically fastened, membrane adhered.
Base Sheet:
One or more plies of ASTM D226 Type II or ASTM D2626 with a minimum 4" side lap and. a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and
two staggered rows 12" o.c. the field of the roll.
Membrane:
One ply of I -Bufit S/A HT TU Underlayment with minimum 3-inch side laps and 6-inch
end laps. Starting at the first coarse, parallel to the eave, align the membrane carefully by
completely unrolling and setting it exactly where it will be, installed: Once aligned; rewind one
half of the length Gently score the release paper on the high side of this roll, ensuring not to
cut through the membrane's thickness. Unroll this first half by evenly peeling back the release
paper while simultaneously and slowly pushing out the membrane. Repeat process for
remaining one half of the length. Once installed, the membrane must be pressure rolled with a
metal or rubber roller. Pressure shall be applied over- the entire surface, paying particular
attention to all side and end laps.
I he 'I n--Built S/A HT TU Underlayment shall be. back nailed to deck with approved annular
ing shank nails and tin caps at a maximum 12" oc. at the side laps and 6" o.c. at the end laps.
Vo nails or tin caps shall be exposed.
"Pproved for Mechanically Fastened Cement or Clay Roof tiles. Tn Built S/A HT TU
Jnderlayment may be used with any approved roof tile system adhered as specified in their
,urrent NOA using any foam adhesive listed and having a current adhesive NOA approval.
NOA No.:15-1123.06
Expiration Date: 09/29/20
Approval Date: 04M/16
Page 3 of 5
'sr
1 :Fire cl as�fitton is not part of this acceptance,
2.: This acceptance is for prepared roofing applications. Minimum deck requirements shall he in compliance with
the:applicable building code. TriBuilt S/A HT TU Underlayment, TriBuilt Smooth HT S/A Underlayment or
Sri=Built Sand-R. SA Shingle Underlayment shall be installed in strict compliance with the applicable building
code.
5.
6.
7.
8.
9.
Tri Built S/A HT TU Underlayment Tri-Built Smooth HT S/A Underlayment or Tri Built Sand-R SA Shingle
Underlayment shall be applied to a smooth, clean and dry surface, free from irregularities. Re -fasten any loose
decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and
debris prior to application. When a smooth, clean and/or dry surface cannot be obtained, the substrate shall be.
primed with Elastocol Stick prior to application.
Tri-Built S/A HT TU Underlayment, Tri-Built Smooth HT S/A Underlayment or Tri Built Sand-R SA Shingle
Underlayment shall not be applied over an existing roof membrane as a recover system but may be applied over a
roofing Base/Anchor sheet underlayment.
Tri Built S/A HT TU Underlayment is acceptable for use in foam adhesive set and mechanically fastened roof tile
systems as specified in the surfacing option of the approved assemblies.
Tri Built Smooth HT S/A Underlayment or Tri Built Sand R SA Shingle Underlayment shall not be left exposed
as a temporary roof for longer than 30 days,
Tri-Built S/A HT TU Underlayment shall not be left exposed as a temporary roof for longer than 180 days of
application -
TA Built S/A HT TU Underlaymem, TH Built Smooth HT S/A Underlayment or Tri Built Sand SA Shingle .
Underlayment may be used with any approved roof covering listing Tri Built S/A HT TU Underlayment, Tri-Built
Smooth HT S/A Underlayment or TriBuilt Sand-R SA Shingle Underlayment. If Tri Built S/A HT.TU
Underlayment, Tri-Built Smooth HT S/A Underlayment or Tri Built Sand R SA Shingle Underlayment is. not
listed, a request may be made to the Authority Having Jurisdiction (AHl) or the 1VTami Dade County Product
Control Department for approval based on the necessary documentation to detail compatibility of the products,
wind uplift resistance and fire resistance results.
When applying the membrane in the valley, start at the low point and work to the, high point, rolling the
membrane from the center outward in both directions. For ridge applications, center the membrane and roll from
the center outwards in both directions.
Membrane shall be applied to protrusions, slope changes, valley, curb, and other roof top penetration details
before any other sections of the roof.
NOA No.:15-1W.06
EW" ion Date: 09R9120
Approval Date.. O'IrM6
Page 4 of 5
PrO#06' ted herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administradw
Code.
1."',33les; must be staged onto Tri-Built S/A HT TU Underlayment not to exceed I O-high, to the standard maximum
i0of pitch of02 for flat tiles and 5:12 for lugged tUcs. Lugged tiles staging at slope > 5:12 shall use alternate
staging method (bottom tile shall be inverted followed by eight tiles high on slope, as illustrated M Figure I
below).
rarm. -t - tuternate staging Method
At roof slopes greater than the Preceding limitations all tiles shall be loaded onto a nominal I " x 2" horizontal
batten to prevent slippage.
All membranes or packaging shall bear the imprint or identifiable cmadang of the mm&chff&s n or logo.city,state and the following statement: "Nami-Dade county ftduct comoi Approved" or the Miami -Dade,
County Product Control Seal as shown below.
INNEENNUMIRM
END OF TIT ACCEPTANCE
NOA No.: 15-1123.06