Loading...
HomeMy WebLinkAboutPRODUCT EVALUATION REPORT - METAL ROOFINGGulfcaaNt SUPPLY & MANUFACIURING Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC. 26 Ga. 51L4'' Crimp Roof Panel over 15132" Plywood Florida Product Approval #11651 J 3 R3 Florida Building Code 2017 Per Rule 61 G20-3 Method: 'i --E) Category: Roofing Subcategory, Metal Roofing C.c)rnpliance Method: 61 G20-.3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 Newberry, HL 32669 %6 \F-L S Engineer Evaluator: Dan Kuhn, RE. #75519 Florida Evaluation APSE ID: 10743 Validator: Lacke Bowden, P.E. #49704 9/450 Alysbljry Place Montgomery, AIL 36117 y NE IV 4, No, STATE ol= :,4z- 0 ID 'F1-?.......... /0j4qA L -4�4 1 %% 0f0j#111qi'01y0/05/2017 Contents: Evaluation Report Pages 1 - 5 mm 9 m 10"2 A.z a Compliance Statement: Product Description: Panel Material/Standards: Panel Dirnension(s): Panel Fastener: Substrate Description: Design Uplift Pressures: FL# 11651.13 R3-s OCTOBER 5, 2017 The product as described in this report has demonstrated cornpliar1-ce with ; Florida Building Code 2017, Sections 1504.3.21. 5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage, thro:agh a,if.ene'd roof panel with fasteners in the panel flat over minirnurn �`::�" 0yv,;ood dec. Non Structural application. Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM � 65--- G90 confio'rn-l..1, to Florida Building Code 2017 Section 1507.4.31. Paint Finish Optional Yield Strength: 80.0 ksi I Corrosion Resistance: Panel Material shall comply with Florida Bui!:-+ing Code 2017, Section '1507.4.3. Thickness: 0.018" Minimum Width: 24" Coverage Rib Height: 3/s" Major Rib #9-15x1.5" with sealing washing in the flat of the panel or approved equa: 1/4" minirnum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2017, Sect;;,>j 1'_;C �.6, 1 `:G (Minimum 15432" thick, APA Rated plywood over supports at rnaximurn 24" C Design of plywood and plywood supports are outside the sco e of this � evaluation. Must be designed in accordance vvI Florida Building Cocle 201 7 Table "A" �..... Fastener Pattern 12 •-12" Fi5i Z 9.5 F ... ....... .. ..... ...t'... Design Pressure includes a Safety Factor = 2.0. I I M'Val;, >Ii:: ,c:e: "he product described herein has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Re'lor" 'Sr-0Pe: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3. Peri+:!. ctt : pan,. lards: The product described herein has demonstrated compliance with: 0 UL 580-06 - Test for Uplift Resistance of Roof Assemblies M Te f I i FL# 11651. z G UL 189/-12 - Uplift Test for Roof Covering Systems. I. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 117-0053T-05 & 117-0331T-08 2. Certificate of independence By Dan Kuhn, P.E. (FL# 75519) C Kuhn Engineering, LLC (FBC Organization # ANE ID: 10743) F qu'l ,valence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL '1897-98 test standard is equivalent to the UL 1897-12 test standard. r .nci., Entity: he manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. R? Iflg1e: Nlinimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Install per Manufacturer's recommended details. Shall comply with Florida Building Code 2017 section 1507.1.1. ication: Fire classification is not part of this acceptance. i•'r11: Shear Diaphragm values are outside the scope of this report. 5, 2017 J Design Procedure: For roofs within the parameters listed on the load -LaL-I-ie, !(:.,rn miu. 1J 1. at a minimum meet, those listed for the applicable wind z,).,)e. i;!:! ru,-',:)fs outs the parameters listed on the load table, design win--' load: shall 1 u,Iermined' for each project in accordance with FBC 201 '7 Section 1 6C,) 0i" I using allowable stress design. The maximun-i fastener 1-1 s 11 not be exceeded. This evaluation report is n.-A., apl-Dlicable in i-Ii, I cAv Hurricane Zone. Refer to current NOA o. HVl-[7 eva!:,Izr-'ir n ;q:%u:; of th i product in High Velocity Hurricane Zone. i q jx X ...... ........ 'N" ......... . . . . . . . . . .. . . ...... . . IN Note: Dimension (a) is defined as 10% of the minimum width of the building or 70PJF.'::: '-- 1� 40% of the mean height of the roof, whichever is smalle , however (a) cannot be less than either 4% of the minimum width of the building or 3 feet. TYPE 1 FASTENER PATTERN -----(1) #9-15 x -I.1/2,: HWH w/Seall g Washer �Q211 --­­,1211 - .._. --- -------------- - --------------- ---------------- =------- ,dt Panel Lap_--/ TYPE 2 FASTENER PATTERN kE[?uE ---------(1) #9..1 a x 1-1/2" HWH w/Sealing Washer ..--- ----�.------._----- `---ia 2 ------- ------------------ ....................:........................................... EAVE I I' 1 i6151. i 1 :,i OCTC):J R 5, "2011 V niv 3-11 % S R,r, < �•.r, >��" K N. C,_ t e (✓t_4 l ENGINM LOAD TADLE. 26 Ga, 6Vawrimp Roof Panel over 15/32" Plywood j WIIND i7ASTENER SUBSTRATE ('PtEil .,,r,`1.1/4" Fcr.eiretio�} ((.911J.15/s2 j il'yvrood ' 120 1 130 1 140 1 150 1 160 1 170 1 180 ON CENTER I ON CENTER I ON CENTER I ON CENTER I ON CENTER� ON CE14TER � ON CENTER SPACING SPACING SPACING ;PACING; SPACING SPACING SPACING 16" TYPE 1 1 16" TYPE 1 1 16" TYPE 1 1 16" TYPE 1 1 16" TYPE 1 1 16" TYPE 1 1 16" TYPE 1 1.) PAN'EL DES`.RiPTION: `_:'r CRIMP, MIN. 26 GA., GRADE 80, 24"COVERAGE. 2.) PAN EL FAST E..NER: K, 1 SX1.5" HW';- WITH SEALING WASHER W/ MIN. A" PENETRATION. .) "..k. ?('•It11'F:} L.1.LCFUu: a i..0 PANEL UPLIFT PRESSURE:-94.25 PSF@ 16" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN, -131.0 P C.: ; STENEr, ;:CIi11G T'r'PE 2 FASTENER, PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.) :>l':^v'dt: OD M CKING: ,01.1%2" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. 5') a.;: " SL) ON RO; SLOF,-S LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.) 'u"AD, TA,_3I, := ;:,SE[) C;P:: WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING COE)'F 017. F:iP ii,1p 'tut;C _ ' I AVE .7OP2E. ;ROOF t — — — — ---- -------- �i Z I d:N. r.. Gulfcda SUPPLY & P94NUFAi:"f;lfiING j TYPE 1 FASTENER PATT f (1) m1 x 1-1 / " HWH w/Sealing Washer ire, t Panel Lap f TYPE 2 FASTENER PATTERN i--------------- (1) -1 x 1-1 / " I°°~ WH /Sealing Washer 2 P P .__ - 5 P—__--__ __ 1 1 y __________9.511 ------------- - gyp, 1 g °]: •%"•.V•'\'s.�.ICO..._e.._._ ________PRE' /:Z�� i i 651.13 R3 vG IOBER 5, 2017 ;fib, n•,f:. � ',: ,, q�ORdd9Bgipp��t w C d q a b N No. 75519 N " y .� • aY a S P' OF N q N + f y ��seo IV.Eli@.o ,� p 1 �:'ti:r �wl^.igl r'��` L, 5• ter �:C