HomeMy WebLinkAboutNOAF
ILE CO3'PY,,c6,v2,'),,
Permitting Dip'Irtment
St. Lucie Couhtb
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
THESE 'PLANS AND ALL PRO
NOTICE OF ACCEPTANCE (NOA) ARE SUBJECT Tn Uff-r-n1
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
,;;k7,$W F (786) 315-2599
GAF REQUIRED BY FIELm lNSP�CTORS TNAi SCANNED
1 Campus Drive MAY BE NECESURY IN ORM TO Py
Par s ipanny, NJ 07054 COhrPLY MTH ALL APPLICABLE CODES. S$ Lucle county
SCOPE:
This, NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used, in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
Thisl NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
Thisl product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Leak Barriers and Roof Deck Protection
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will. occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall Ibe available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 14-0915.02 and consists of pages 1 through 7.
The submitted documentation was reviewed by Hamley Pacheco, P.E.
NOA No.: 16-1213.04
MIAMMADEC01 Expiration Date: 02/21/18
Approval Date: 11/16/17
Page 1 of 7
f-
ROOFING COMPONENT APPROVAL
Cat6gory: Roofing
Sub;Cate$!ory: Underlayment
Material: SBS/Polypropylene/Asphalt
PRODUCTS DESCRIPTION:
Product
WeatherWatch®
Mineral Surfaced Leak
Bar�'ier
Manufacturing
Location #1, 10
StormGuard® Film
Surfaced Leak Barrier
Manufacturing
Loc Ition #1,10
LibertyTM SBS Self -
Adhering Base/Ply
Sheet
Manufacturing
Location #1,10
Deck -Armor "I
Premium Breathable
Roof Deck Protection
Manufacturing
Location #2
Tiger PawTM Roof Deck
Protection
i
FeltBuster® Higli=)
Tractog_Synflietc!
Shingle -Mate' Roof
Deck! Protection
Location #4, 5
Dimensions
Test
Specification
Product
Description
36" x 50' rolls ASTM D 1970 Granular surfaced modified, fiberglass reinforced,
36" x 66.7' rolls bituminous sheet material for use as a leak barrier
underlayment in sloped roof assemblies.
Designed as an ice & rain shield.
36" x 66.7' rolls ASTM D 1970 Modified, fiberglass reinforced, bituminous sheet
material for use as a high temperature leak barrier
underlayment in sloped roof assemblies.
Designed as an ice & rain shield.
393/8" x 66' rolls ASTM D 1970 Self -adhering SBS roof membrane.
ASTM D 4601
Type II
54" x 222' rolls ASTM D 226 A UV -stabilized polypropylene breathable
48" x 100' rolls Type II underlayment. To be used for roof deck
protection as an underlayment in sloped roof
assemblies.
48" x 250' rolls ASTM D 226 A UV -stabilized polypropylene non -breathable
48" x 100' rolls Type II underlayment. To be used for roof deck protection
as an underlayment in sloped roof assemblies.
48 250' rolls ASTM D 226 A UV -stabilized polypropylene non -breathable
Type I underlayment. To be used for roof deck protection
as an underlayment in sloped roof assemblies.
36" x 144' rolls ASTM D 226 Fibergass-reinforced asphalt felt underlayment. To
Type I be used for roof deck protection as an
underlayment in sloped roof assemblies.
NOA No.: 16-1213.04
MIAMFOAflECOI) Expiration Date: 02/21/18
Approval Date: 11/16/17
Page 2 of 7
M NUFACTURING LOCATION:
1.
Mt. Vernon, IN
2.
North Bay, Ontario
3.
Mission, British Columbia
4.
Pryor, OK
5.
McGregor, TX
6.
I Qingdao, China
7.
Charleston, SC
S.
Spartanburg, SC
9.
Dadra, India
10. Savannah, GA
EVID
ENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Integek Testing Services NA Ltd.
3077464-01
ASTM D 1970
08/23/06
3090131
Wind Uplift and Self Sealability
08/23/06
100258583COQ-OIOA
ASTM D 226 Type II
01/11/11
100673818COQ-003
ASTM D 226 Type II
06/13/13
10157289000Q-005
ASTM D 226 Type II
04/17/14
F8549.02-106-18
ASTM D 226 Type II
11/08/16
PRI Construction Materials
RGM-023-02-01
ASTM D 4798
05/16/07
Technologies, LLC.
GAF-112-02-01
ASTM D 226 Type II
03/15/06
GAF-238-02-01
ASTM D 1970
03/03/10
GAF-323-02-01
ASTM D 1970
11/30/11
GAF-324-02-01
ASTM D 1970
11/30/11
GAF-325-02-01
ASTM D 1970
11/30/11
GAF-326-02-01
ASTM D 1970
11/30/11
j
GAF-275-02-01
ASTM D 1970
11/11/10
GAF-344-02-01
ASTM D 1970
04/23/12
GAF-339-02-01
ASTM D 226 Type I
03/14/12
ELK-311-02-01
ASTM D 1970
09/11/07
GAF-446-02-01
ASTM D 226 Type I
09/26/13
GAF-518-02-01
ASTM D 226 Type I
06/04/14
TrinitylERD
GAF-SC13285.03.17-1
ASTM D1970
03/08/17
GAF-SC13285.03.17-3
ASTM D1970
03/01/17
GAF-SC13285.03.17-4
ASTM D1970
03/01/17
GAF-SC13285.02.17-2
ASTM D4601 Type II
02/08/17
NOA No.: 16-1213.04
hflAhit t7A0E �;� Expiration Date: 02/21/18
Approval Date: 11/16/17
Page 3 of 7
APPROVED ASSEMBLIES:
Deck Type 1: Wood, non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E (1): Anchor sheet mechanically fastened to deck, membrane adhered.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle -Mate® Roof Deck Protection OR one or more plies
of ASTM D 226 Type II, Deck -Armor" Premium Breathable Roof Deck Protection, FeltBuster®
High -Traction Synthetic Roofing Felt, or Tiger PaA TJ' Roof Deck Protection with a minimum 4"
side lap and a 6" end lap mechanically fastened to the deck with approved nails and tin caps 6"
o.c. at the laps and four staggered rows 12" .o.c. in the field of the roll.
If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape (follow the tape's manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fastneners.
Membrane: One or more plies of WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film
Surfaced Leak Barrier, or LibertyTM SBS Self -Adhering Base/Ply Sheet membrane with a
minimum 3" side lap and 6" end lap. Place the first course of membrane parallel to the eave,
rolling the membrane to obtain maximum contact. Remove the release membrane as the
membrane is applied. Vertical strapping of the roof with WeatherWatch® Mineral Surfaced
Leak Barrier or StormGuard® Film Surfaced Leak Barrier is acceptable.
Surfacing: Approved Roofing Assembly.
Deck Type 1: Wood, non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(2): Membrane mechanically fastened to deck.
Separator Sheet: One or more plies of GAF GAFGLAS® Ply 4, GAFGLAS® Flex-PlyTM 6, Rosin Paper, ASTM D
226 Type I or Type II, Shingle -Mate® Roof Deck Protection, Deck-Armoi, Premium
Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, or Tiger
Pawl' Roof Deck Protection loose laid.
Membrane: One or more plies of WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film
Surfaced Leak Barrier, or LibertyTM SBS Self -Adhering Base/Ply Sheet membrane mechanically
fastened with a minimum 3" side lap and a 6" end lap to deck through the separator sheet with
approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. in the field of the
roll.
i
Surfacing: Approved Roofing Assembly.
NOA No.: 16-1213.04
ctrAMttaAD�ouNTY Expiration Date: 02/21/18
Approval Date: 11/16/17
Page 4 of 7
Deck Type 1:
Wood, non -insulated
Deck Description:
"/32" or greater plywood or wood plank
System E (3):
Anchor sheet mechanically fastened to deck, membrane adhered.
Secondary Water
Install a minimum 4" wide WeatherWatch® Mineral Surfaced Leak Barrier or StormGuard® Film
Barrier:
Surfaced Leak Barrier membrane over the joints of the plywood roof deck prior to installation of
(Optional)
the base sheet. Do not overlap end or side joints. All side and end laps should be butted firmly
side by side, flush with each other but not overlapped. Do not leave the WeatherWatch® Mineral
Surfaced Leak Barrier or StormGuard® Film Surfaced Leak Barrier membrane exposed for more
than 30 days without a roof deck protection underlayment protecting the secondary water barrier.
Base Sheet:
Two plies of ASTM D 226 Type I or Shingle -Mate® Roof Deck Protection OR one or more plies
of ASTM D 226 Type II, Deck -Armor m Premium Breathable Roof Deck Protection,
FeltBusterl High -Traction Synthetic Roofing Felt, or Tiger Paw1m Roof Deck Protection with a
minimum 4" side lap and a 6" end lap mechanically fastened to the deck with approved nails and
tin caps 6" o.c. at the laps and four staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape (follow the tape manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fasteners.
Sur i acing:
Approved Roofing Assembly.
I
Deck Type 1:
Wood, non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E (4): Anchor sheet mechanically fastened to deck, membrane adhered.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle -Mate® Roof Deck Protection OR one or more plies
of ASTM D 226 Type II, Deck-Armoill Premium Breathable Roof Deck Protection,
FeltBuster® High -Traction Synthetic Roofing Felt, or Tiger Paw' Roof Deck Protection with a
minimum 4" side lap and a 6" end lap mechanically fastened to the deck with approved nails and
tin caps 6" o.c. at the laps and four staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape (follow the tape's manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fastneners.
Membrane: One or more plies of StormGuard® Film Surfaced Leak Barrier membrane with a minimum 4"
side lap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the
membrane to obtain maximum contact. Remove the release membrane as the membrane is
applied.
Siirfacmg' ;Approved for Metal roof ng (StormGuard®;Film; Surfaced L eak Barrier; Slate, and Asphalt
Shingle assemblies':
WMIAMMADECOUNTYIN
NOA No.: 16-1213.04
Expiration Dater 02/21/18
Approval Date: 11/16/17
Page 5 of 7
LIMITATIONS:
1. (Fire classification is not part of this acceptance.
2. ' WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-
lAdhering Base/Ply Sheet, Shingle -Mate' Roof Deck Protection, Deck-ArmoF' Premium Breathable Roof Deck
(Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection shall not be
used as roof tile underlayment.
3. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
lapplicable building code. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak
Barrier, LibertyTM SBS Self -Adhering Base/Ply Sheet, Shingle -Mate® Roof Deck Protection, Deck-ArmorTM
(Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger PawTM
IRoof Deck Protection shall be installed in strict compliance with applicable Building Code.
4. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-
lAdhering Base/Ply Sheet, Shingle -Mate® Roof Deck Protection, Deck-ArmorTM Premium Breathable Roof Deck
Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection membranes
shall be applied to a smooth, clean and dry surface with deck free of irregularities. (
5. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self -
Adhering Base/Ply Sheet, Shingle -Mate® Roof Deck Protection, Deck-ArmorTM Premium Breathable Roof Deck
Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger Pawl1 Roof Deck Protection membranes
I
hall not be applied over an existing roof membrane.
6. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self -
Adhering. Base/Ply Sheet, Shingle -Mate® Roof Deck Protection, Deck-ArmorTM Premium Breathable Roof Deck
Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection shall not be
left exposed as a temporary roof for longer than 30 days of application.
7. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self -
Adhering Base/Ply Sheet, Shingle -Mate® Roof Deck Protection, Deck-ArmorTM Premium Breathable Roof Deck
Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection may be used
with any approved roof covering Notice of Acceptance listing WeatherWatch® Mineral Surfaced Leak Barrier,
StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self -Adhering Base/Ply Sheet, Shingle -Mate® Roof
Deck Protection, Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic
Roofing Felt, and Tiger PawTM Roof Deck Protection as a component part of an assembly in the Notice of
Acceptance. If WeatherWatch® Mineral Surfaced Leak Barrier, StormGuardo Film Surfaced Leak Barrier,
LibertyTM SBS Self -Adhering Base/Ply Sheet, Shingle -Mate® Roof Deck Protection, Deck-ArmorTM Premium
Breathable Roof Deck Protection, FeltBuster° High -Traction Synthetic Roofing Felt and Tiger PawTM Roof Deck
Protection are not listed; a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade
County Product Control Department for approval provided that appropriate documentation is provided to detail
compatibility of the products, wind uplift resistance, and fire testing results.
8. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application. Install when temperatures are 45' F and
rising.
9. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in both directions.
10. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
o�v erlap areas.
11. FIlash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Qrt�aM® NOA No.: 16-1213.04
�a�r��tiuNnr Expiration Date: 02/21/18
+ Approval Date: 11/16/17
Page 6 of 7
e
l
LIMITATIONS:
(Notice of Acceptance and applicable Building Code.
12. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
13. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
KAWDADE COUNTY
END OF THIS ACCEPTANCE
i
MIAMI-DARE COUNTY
NOA No.: 16-1213.04
Expiration Date: 02/21/18
Approval Date: 11/16/17
Page 7 of 7