Loading...
HomeMy WebLinkAboutPLANS.024 ALUM ROCF 7 RIDGED POLYSTYRENE INSULATION EXISTING MOBILE HOME ROOF EXTRUDED ALUM. ATTACH RAIL wl#8X1114 S.M.S.-3' O.C. BUTYL RUBBER SEAL 024ALUM FLASHING BUM RUBBER SEAL UDEDALUM ATTACH RAIL wl#8X1 1I4 S.M.S. 3' O.C. 2X3 P.T. WI#BX3' W.S. @ 9' O.C. 024ALUM ROOF INTO EXISTING COACH FRAME_ ,,,",,, ,- ,, -: - FRAME G COACH ► \ I. -FASTING P4T10 ROOF EXISTING WALL CHANNEL ALTERNATE COACH & PATIO ROOF ATTACHMENT #1 CONNECTION DETAIL (NTS) (NO 4th WALL) I .024 ALUM ROOF 7 RIDGED POLYSTYRENE INSULATION EXISTING MOBILE HOME ROOF . EXTRUDED ALUM. ATTACH RAIL w/#8X11!4 S.M.S. 3'O.C. BUTYL.RUBBERSEAL ZI .024 ALUM ROOF FLASHING 1 i � UD ALUM. ATTACH RAIL wl#8X11N S.M.S.3' O.C. 2X3 P.T. W/ #BXT W.S. @ 6' O.C. BUM RUBBER SEAL INTO EXISTING ROOF /�/�/ .024 ALUM ROOF 30# FELT ON TOP OF ors_ PANS 2X3 P.T. BLOCKS CUT TO FIT INTO �fj PANS w/ (2) #8 S.M.S. PER PAN -`�v� W �� i EXISTING PANS wl EXISTING COACH INSULATION INSERTS FRAME EXISTING ALUM. COL &BEAM ALTERNATE COACH & PATIO ROOF ATTACHMENT #2 CONNECTION DETAIL (NTS) .(w/ 4th WALL) .024 ALUM 1 7 RIDGED POLYSTYRENE INSULATION EXISTING MOBILE HOME ROOF-7 - 2X3 P.T. WI .024 ALUM ROOF F-EITRL'DED ALUM. ATTACH RAIL .024 ALUM ROOF CONT. OVER 7 RIDGED POLYSTYRENE INSULATION wl SBXt 114 S.M.S. 3' O.C. RIDGE WI FACTORY SE AS @ 48' O.C. EXISTING PATIO ROOF FASCIA EDGE DETAIL OR - - - — — BUTYL RUBBERSEAL - GUTiER£DGE DETAIL- - - COACH AND-PAIlOROOF_ .024 ALUM FLASHING INTO PAN '� _-_--__---_- CONNECTION DETAILS AND CAULK ORCONTINUE _ __-___---____ FOAM INSULATION FLASHING TO GUTTER '' ®L, _ �. ---+--- \-----------�__� _) �, 248 SMS W NEOPRENE iqJ1 ) I -INSULATION _ ® I r,�-- 024A.LUM ROOF WASHERS TO TOP OF EACH P:1 k / I !I 2X3P.T.wl,-W'W.S.Q6'O.C.� Z0 P.T. BLOCKS CUT TO FIT INTO yy PANS w/ (2) 98 S.M.S. PER PAW -EXISTING _ I OVERHANG EX!STINGALUM LPOLYSTYRENEFOAM COL. & BEAM INSERT EACH PAI1 _ _ .024 ALUM ROOF RNA`TUA IO�AN RO_C�F OTT, CFIUI I' i GET, )k[ �N. 7 r 1 GED POLYSTYRENE INSULATION �/ EA,�TING MOBILE HOME ROOF RUDEDALU.M.ATTACHRAIL � �. �_r 024ALUM ROOF wl#eX1114S.M.S.TO.C. L.�,',"! 30# FELT ON TOP OF M PANS BURUBBER SF1L 024 ALUM FLASHING INTO PAN AND CAULK OR CONTINUE FLASHING TO GUTTER 2X3 P.T. W!#0 2- B SMS W NEOPRENEE INTO EX STING WASHERS TO TOP OF EACH Pm EXISTING I MC5ILEHCMEROOF SINGLE WIDE (NTS) TYPICAEROOr SECTIO N N.T.S. 094W STAINLESS STEEL HEX( HEAD FROM ATTACHMENT RAIL TO EXISTING MOBILE HOME FRAME @ 5' O.C. MIN. INTO EATSTINC FRAMING EXTRUDED ALUM. ATTACH RAIL 118''11' WIDE BUM RUBBER CONT. wl #2X11A S.M.S. T O.C. .024 RO! L ALUMINUM INSULATION �SUTYLRUBBER SEAL - RGOF ATTACH CONT 2 A' P.T. TO EXISTING . MOBILE HOME FRAMING W/#8K!' WOOD SCREWS (il SPACING TO STRAIGHTEN WOOD ONLY, IN LIEU OF FULL FRAMUNG ATTACHMENT PER DETAILS EXISTING PANS w/ INSULATION INSERTS TT i— 'Ti�l�T ,� �, �/f/ .024 ALUM GUTTER /� WI STRAPS 4'-0O.C. 2X3 P.T. BLOCKS CUT TO FIT INTO •1 l� y/ I DDanNG COACH PANS wl (2) #8 S.M.S. PER PAN , FRAME EXISTING ,OV�_RHAWG ExinNGALUM. POLYSTYRENE FOAM GUTTER EDGE DETAIL COL &BEAM INSERT EACHPAN A N.T.S. ALTERNATE PATIO PAN R00� ATTACHMENT DETAIL "B" N.T.S. I - ® py EC BUM RUBBER SI 7 RIDGED POLYSTYRENE INSULATION OVERLAPPING .024'ALUM OVERLAPPING EXTRUDED ALUM, ATTACH RAIL w! #8X1 114 S.M.S. T O.C. ,,_�2X3 P.T. w188X3' W.S. @ 3. O.C. / %- FOAM FILLER I EXTRUDED ALUM. ATTACH RAIL EXISTING CENTER ER CAP "STING COACT! FRAMING wl#8X1114S.M.S.TO.C. r-BUTYLRUBBER SEAL 'A' p 7 # BLE-Y-Y-IDERIG EMTIAIL--� 024 ALUM ROOF — r .. N.T.S. 2' RIDGED FOLYSTYRENEE INSULATION OVERLAPPING .024ALUM ROOF \ .024 ALUM ROOF 7 RIDGED POLYSTYRENE INSULATION STYRENE-BUTADIENE FACTORY SEAM DESIGN FOR RUBBER SEALANT DLISTINGMOBIL HQ'AE:ROGF wl0XIEDAM.S.Y O.C.H RAIL ALUMINUM ROOF COVERI_GS: BETWE=_NSHEET &CLEAT �wl#BX11/4S.M.S.3°. I PATO ROOF 3' 3 e ROOF NT DETAILS r NOTE: THIS uTERINTE NA YdEUSEOT00lATIN PROGRESSINSPECTRW OF FRWNG ROTE TIi�COl4iECIIGV MAYBE ISEO ATOLL MtUlECf10NAREASAS ALTERNAIECWTU:CIION O Z O U EXTRUDEDALUMINUM ATTACHMENT RAIL wi Ax1414 STAINLESS STEEL SCREWS 0 S' O.C. INTO EXISTING MOBILE HOME PRE -PUNCHED HOLES. FRAMING & ROOFING ALTERNATE ATTACHMENT RAIL FASTENING #1 N.T.S. .024 GALVALUME CLEAT 48' O.C. (IYP) EXTRUDED ALUM, ATTACH R4iL w/#W%S.M.S. 3' O.C. / P.T. WOOD BLOCK%/ 0-3-W.S. Q SPANNING TO STRAIGHTEN WOOD ONLY OVER SOLID ROOFS ONLY#PRODUCT APPROVAL #FL57s0-R4 eimL RUBBER sEAL .OVER ATTACHED STRUCTURES PRODUCT APPROVAL #FL17570-RO 024 ALUM FASCIA N.T.S. AT 9DJACuNT PATIO ROOF NOTES: 2X3 P.T.W'#2 w^,v.S. @ 6' O.C. PROVIDE.024 FLASHING 1.) �TPlS DESIGN CONFORMS TO TI L� 2017 FLORIC B!IILDING CODE FQR A_; 4 �f.. - INTO EX STING C(.1CH FRAME/ INTO PATIC ROOF (MIN 81 C ATE GC R II BU! DING FGR WIND,LOADJING OF.185 MPH EXPa5liFiE''C A$ wme SMS @ 17 O.C. DETERMWCD BY ASCE STAND- 7.� 2.) THIS-DESIUN-CONFORMS-TO-F LE6R[DA STATUTE 15C-2.0081 FOR EXISTING EXTRUDED WALL CHfNNEi MOBILE/MANUFACTURED HOME REPAIR AND REMODELING. 3.) ALUMINUM ROOFING IS DESIGNED FOR USE.OVER A SOLID ROOF ONLY IT EXISTING COACH FRAME DOSTINAN14'- ROOF MAX SPANI4'$' TAPERED INSULATION AS REQUIRED EXISTING WALL CHANNEL FOAM FLLER 'AIIE3NATE�-AC PATIO QOF AfJACL�IIENJ=# EXISTING CENTERCCAP r� STING COACH FRAMING �p� CONNECTION DETAIL (NTS) (NO DROP BETWEEN ROOFS) DOUBLE WIDE RIDGE DETAIL USING ALTER.WATE #1 ATTACHMENT ( NTS) MOBILE HOME ALUMINUM ROOF OVER PLAN FOR 185 MPH EXPOSURE C E^.'rTIiJG COACH SHALL NOT BE USED AS A STRUCTURAL ROOF SYSTEM. 4.) THE P000 -,COVERING SHALL NOT OVERHANG THE EXISTING.ROOF. 5.) ENGINEER IS NOT RESPONSIBLE FOR STRUCTURAL INTEGRITY OF EXISTING ROOF. THE -STRUCTURE OF THE EXISTING ROOF SHOULD BE ABLE TO SUPPORT THE CONSTRUCTION LOADING -FOR THE NEW ROOF SYSTEM. r' T it a 6.) MAXIM4'-0 UM WIDTH OF A SINGLE WIDE MOBILE HOME NOT TO EXCEED 1. !a7 %IT1 L E RAI L T.) MAXIML;..i WID. H OF A DOUBLE WIDE MOBILE HOME NOT TO EXCEED 28'-0 �� I N• I �• 81 INSUUJIGN TO DCPOI YSTYPENE FORM APROX DENSITY 1# PER S F 0.) MAXIMUM HEIGHT OF MOBILE HOME NOT TO EXCEED 16-W. 10.) MINIMUM THICKNESS OF ALL ROOF FLASHING TO BE .G4 ALUM. 11.) THE R-VALUE OF THE 2' EPS INSULATION IS Rom:/. ssal=e ;re. Si of 2 OWNER: , 'L= G� `-a � ,j SNOT V.'V_I ` ciN;:ESS GATED' ADDRESS: & SEALED WITH EMBOSSED C� rL F}rJQ� ��PrN� N'p C_T -"�ENGIN SEAL CITY: P l.JZC STATE: ZIP: �L�9 S� ( �.�Z�� LOT# BLOCK# PANGE; 3�' � JAMES BUoHOUSE, P.E. PROFESSIONAL ENGINEER 20311 STATE OF FLORIDA W Q 0 C3 to co cq v�•C cza 4S, ca �� eq Cb "y Cb IJ .Cp C 4 cv . �o V to Hto BO W U01 64 I 3tl/E�( p4� ,�� 0.6 to We CAD tj u 024 ALUM 7 RIDGED POLYSTYRET `INSULATION 3'M!NTHICK BONDED PANEL � NOTEi EXTRUDED ALUM. ATTACH RAIL wl#BX11/4 S.M.S. 3' O.C. EXTRUDED ALUM. ATTACH RAIL w/#BX1 1/4 S.M.& 3' O.C: 12'xl2'x.024'ALUM CAP 7 MAX2fl WIDTH rBUTYLRUBBERSEAL " PARK MODEL.DETAIL A BON E w/ N EL I TO SCREWS B 8' O.C. THRU N.T.S. BONDED PANEL INTO EXISTING BEAM' 024 ALUM FLASHING FILE., OPY fEXTRUDED ALUM. ATTACH RAIL wl #8X1 114 S.M.S.3' O.C. BUM RUBBER SEAL a 1 .024ALUM BASHING _ EXTRUDED ALUM. ATTACH RAIL BU w/#8X1 1/4 S.M.S. 3' O.C. MAX 17 SPAN BONDED PANEL 12'xl2'x.024 ALUM CAP / 1' MAX O.H. EXISTINGALUM. j EXISTING' LAP OF ROOF ROLL TO BE ON DOWNWARD SIDE COL &BEAM / OVERHANG OR FRAMING BONDED PANEL ROOF EDGE DETAI N.T.S. . .024 ALUM ROOF ' 7 RIDGED POLYSTYRENE UDED ALUM. ATTACH RAIL INSULATION wl#SX11/4 S.M.S. T O.C. BUM RUBBER SEAL `� 1 .024 ALUM FLASHING 3'MINTHICK BONDED PANEL 2W' PT wl #B:T SMS @ O INTO NOTE: EXTRUDED METAL & BONDED PANEL MAX 17 SPAN BONDED PANEL j 1' MAX O.H. _ 032EXTRUDED FASCIA EXISTING ALUM. / EXISTING ORGUTTER COL &BEAM OVERHANGy� OR FRAMING \\\\\\ BONDED PANEL ROOF EDGE DETAIL #1 N.T.S. MOBILE HOME ALUMINUM ROOF OVER PLAN FOR 185 MPH EXPOSURE C MAX 14' WIDTH PARK MODEL DETAIL B N.T.S. UTYL RUBBER SEAL 2 A4' PT CONT. W/#BX3' WOOD SC', Ei @ 6' O.C. TO RIDGE BEAM & 1-#8x3' WOOD' SCREW TO EACH TRUSS \ \ .024 ALUM ROOF 2' RIDGED POLYSTYRENE INSULATION fi- 2-W WOOD TRUSS @ 1J' r 24'O.C. w/ 1/2' SHEATHING EXTRUDED ALUM. ATTACH RAIL w/ #BX1 1/4 S.M.S. 3' O.C. J 1> , ,. BUTYL RUBBER SEAL I---- FASCIA EDGE & DETAILS, SEA— 1 2x4 P.T. w/ #8x3'WOOD SCREWS MAX 18' O.H.--I @ 6' O.C. TO FASCIA W/ 14/8x3' TO EACH TRUSS TAIL @ 24'O.C. CONTINUOUS 2' FASCIA TYP. m q m co O _ � � � O O1. 4 0 Z H 'NOTE: NOTES ARE TYPICAL FOR BOTH SIDES OF ROOF 20 o. U, TYL RUBBER SEAL O 25c4' PT CONT. w/ 2- #8x3' WOOD SCREWS TO EACH TRUSS �toc :. \ \ .024 ALUM ROOF 2' RIDGED POLYSTYRENE INSULATION rji ' 25c4' WOOD TRUSS @ O �T , 24'O.C. w/ 1/Y SHEATHING EXTRUDED ALUM. ATTACH RAIL p w cle G"Ge w/#BX7 1/4 S.M,S.3' O.C. S �} BUTYL RUBBER SEAL � -� o� tp SEE GUTTER & _---COFASCIA EDGE Tel 1 j DETAILS. S 1+, 1.rA k3 2x4 P.T. w/#Bx3'WOOD SCREWS a, MAX 18' O.H:--�� Cd112' O.C. TO FASCIAw/ 14/8x3' 1�cQ TO.EAC H TRUSS TAIL @ 24'O.C. t, ; CONTINUOUS 2' FASCIATYP. tC FRENE E, to ISO 95+GL INSULATION BOARD MAY (�, �LIEU OF THE POLYSTYRENE BOARD IN THE SAME 2' THICKNESS.' y .w OWNER ADDRESS: CITY: STATE: 21P: LOT# BLOCK# RANGE: ch N W N 4 g SHEET No.: S2 Of 2 NOT VALID UNLESS DATED & SEALED WITH EMBOSSED 4 ENGINE ' SEAL 4/L l Z . se JAMES BUSHOUSE, P.E. PROFESSIONAL ENGINEER 20311 (_) STATE OF FLORIDA