HomeMy WebLinkAboutEVALUATION REPORT - METAL ROOFING.r
CREEK
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Manufacturer:
Manufacturing:
Quality Assurance:
SCOPE
Category:
Subcategory:
Code Sections:
Properties:
PRODUCT DESCRIPTION
BORAL ROOFING, LLC
3093 "A" Industry Street
Oceanside, CA 92054
(760)435-9842
www.aerardusa.com
Oceanside, CA
UL LLC (QUA9625)
Roofing
Metal Roofing
1504.3.1, 1504.3.2, 1518.9, 1523.6.5.2.4
Wind Resistance, Physical Properties
Certificate of Authorization No. 29824
17520.Edinburgh Dr
Tampa, FL 33647
(813) 480-3421
FLORIDA BUILDING CODE, 6' EDITION (2017)
Issued June 14, 2018
is SCANNED
BY
Lucie County
Pine Crest Shake
Profile: 16 in. x 52 in, panel; leading edge is turned down 1 in. and back edge is bent up and horizontally
back 1.5 in. Panel side laps are 2 in.
Description: Preformed, fastened, stoned -coated steel panels with No. 14 granule
Material: Min. 26 ga. ASTM A792 AZ50; Fy = min. 40 ksi; Shall conform with FBC Section 1507.4.3
Cottaae Shinale
Profile: 14 in. x 51 in. panel; leading edge is turned down 1 in. and back edge is bent up and horizontally
back 1.5 in. Panel side laps are 2 in.
Description: Preformed, fastened, stoned -coated steel panels with No. 14 granule
Material: Min. 26 ga. ASTM A792 AZ50; Fy = min. 40 ksi; Shall conform with FBC Section 1507.4.3
BOR18002 FL27408 Page 1 of 14
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
I
Pacific Tile
i
Profile:
Description:
Material:
BORAL ROOFING LLC
Metal Shingles
16 in. x 52 in. panel; leading edge is turned down 1 in. and back edge is bent up and horizontally
back 1.5 in. Panel side laps are 2 in.
Preformed, fastened, stoned -coated steel panels with No. 14 granule
Min. 26 ga. ASTM A792 AZ50; Fy = min. 40 ksi; Shall conform with FBC Section 1507.4.3
Barrel Vault Tile
Profile: 13-1/2 in. to 14 in, x 45-1/8 in. panel
Description: Preformed, fastened, stoned -coated steel panels with No. 14 granule
Material: Min. 26 ga. ASTM A792 AZ50; Fy = min. 40 ksi; Shall conform with FBC Section 1507.4.3
BOR18002 FL27408
I IOA cvaILUUUII IUPUII IS IAUVIutlU IUI OLULU UI riuma IJIUUUGI UPIAUVUI UllUul Mum U VLu-O. I Flu 111dFlUIaGWICI Snan flullly IiRCCn
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GD E E i j BORAL ROOFING LLC
Ii I1 Metal Shingles
TECHNICAL SERVICES, LLC
INSTALLATION
Note - Refer to the APPROVED ASSEMBLIES section of this report for the maximum design pressures of the approved
assemblies.
Unless otherwise specified in this report the following installation details shall be met for the named products:
Direct -to -Deck Installation Patterns
Pine Crest Shake - Direct -to -Deck Pattern 1 Pine Crest Shake - Direct -to -Deck Pattern 2
Cottage Shingle - Direct -to -Deck Pattern 1
Pacific Tile - Direct -to -Deck Pattern 1
Cottage Shingle - Direct -to -Deck Pattern 2
Pacific Tile - Direct -to -Deck Pattern 2
BOR18002 FL27408
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
l v
V
CREEK
TECHNICAL SERVICES, LLC
Direct -to -Deck Installation Patterns
i
i Pacific Tile - Batten Pattern 1
I
I
Barrel Vault - Batten Pattern 1
BORAL ROOFING LLC
Metal Shingles
Barrel Vault - Direct -to -Deck Pattern 2
Batten Spacing
Panel
Sod Battens Fastener woad Battens
Roof Panel
Pine Crest Shake - Batten Pattern 2
Pacific Tile - Batten Pattern 2
Barrel Vault - Batten Pattern 2
1\
BOR18002 FL27408
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Granite Ridge Installation Patterns
j
Roof Panel
j hn�Ply -Sheathing
I
j Granite Ridge - Direct-to-Deck
J 461116"
! T T T T T T T
BOR18002 FL27408
BORAL ROOFING LLC
Metal Shingles
Panel Fastener
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
r
BORAL ROOFING LLC
CREEK Metal Shingles
TECHNICAL SERVICES, LLC
APPROVED ASSEMBLIES
Slope: 3:12 or greater
Solid or closely fitted min. 15/32 in. plywood sheathing for new and existing construction at
Roof Deck: max. 24 in. span; In the HVHZ, new construction shall be min. 19/32 in. plywood at max.
24 in. span; Designed by others in accordance with FBC requirements.
Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment
Underlayment: shall be ASTM D 226, Type II installed in accordance with Section 1518.2 or any approved
underlayment for use in the HVHZ.
26 ga. Metal Panel installed as shown in INSTALLATION with four (4) #10-16 x 2-1/2 in.
HWH corrosion resistant wood screws through the vertical leg at the headlap'beginning at
Attachment: the center of the side lap and four (4) #10-16 x 2-1/12 in. HWH corrosion resistant wood
screws through the horizontal leg at the back of panel beginning at the side lap. Fasteners
shall penetrate through the deck a minimum 3/8" and shall comply with section 1506.6 and
1507.4.4.
Maximum Design -52.6 psf
Pressures: Pressure calculated using 2:1 marcmin of safety
B
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
C
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
42ft
D
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
31ft
19ft
2 Penmeter
r,;
..--ryZOne
B
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
55ft
36ft
NA
C
60 ft
60 ft
60 ft
60 ft
50 ft
26 ft
NA
NA
NA
D
60 ft
60 ft
60 ft
48 ft
21 ft
I NA
NA
NA
NA
B 60 ft 60 ft 60 ft 60 ft 35 ft NA NA NA NA
C 60 ft 60 ft 33 ft 19 ft NA NA NA NA NA
D 60 ft 35 ft NA NA NA NA NA NA NA
Notes: 1) Exposure category for the structure location shall be as defined in the International Building Code 2) Limitations are
based on the exposed area of 10ft2 or less 3) Topographic factors such as escarpments or hills are not included in the above
assessment 4) Applicable for Enclosed Buildings without overhangs 5) NA = "Not Allowed" 6) Kd = 0.85 7) Projects with mean roof
heights of greater than 60 ft shall be evaluated by a licensed design professional 8) See page 13 for details for dimensions and
locales of Zone 1, 2, and 3 9) V,,,t is shown in the above table. Design pressures are calculated using. Veld = Vui,g0.6.
For hip roofs 2:12 to 5.6:12, Zone 3 shall be treated as Zone 2
BOR18002 FL27408
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEij BORAL ROOFING LLC
Il Metal Shingles
TECHNICAL SERVICES, LLC
Slope: 3:12 or greater
Solid or closely fitted min. 15/32 in. plywood sheathing for new and existing construction at
Roof Deck: max. 24 in. span; In the HVHZ, new construction shall be min. 19132 in. plywood at max.
24 in. span; Designed by others in accordance with FBC requirements.
Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment
Underlayment: shall be ASTM D 226, Type II installed in accordance with Section 1518.2 or any approved
underlayment for use in the HVHZ.
26 ga. Metal Panel installed as shown in INSTALLAT101V with eight (8) #10-16 x 2-1/2 in.
HWH corrosion resistant wood screws through the vertical leg at the headlap beginning at
Attachment: the center of the side lap and eight (8) #10-16 x 2-1/2 in. HWH corrosion resistant wood
screws through the horizontal leg at the back of panel beginning at the side lap. Fasteners
shall penetrate through the deck a minimum 3/8" and shall comply with section 1506.6 and
1507.4.4.
Maximum Design -127.5 psf
Pressures: Pressure calculated using 2:1 margin of safety
Maxr GahielHip�Roof
r
s 6 _ ^�
,a <<
a ��aslc WI'd ,Speed
Ex osurEw as
„ �00_ 1"1#)f0a �3Q 10 1a01 170, 18=
�.
IRE' � s-y^� "`t�a'a ssvy� � .«` � � s
g!
B 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft
C 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft
D 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft
a&..�_'-. �� „3:... h a'a.�a. r�a�.. ,«.�.... _� .'r_ .__ ��'.r�.«.x .��.. _. ..._, ,,,, - .. ::°":... ;,z.•' ,��a. hN� „«.w"
B 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft
C 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft
D 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft
B 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft
C 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 48 ft
D 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 38ft 20ft
Notes: 1) Exposure category for the structure location shall be as defined in the International Building Code 2) Limitations are
based on the exposed area of 10ft2 or less 3) Topographic factors such as escarpments or hills are not included in the above
assessment 4) Applicable for Enclosed Buildings without overhangs 5) NA = "Not Allowed" 6) Kd = 0.85 7) Projects with mean roof
heights of greater than 60 ft shall be evaluated by a licensed design professional 8) See page 13 for details for dimensions and
locales of Zone 1, 2, and 3 9) V it is shown in the above table. Design pressures are calculated using Vnd = V�lt40.6.
For hip roofs 2:12 to 5.6:12, Zone 3 shall be treated as Zone 2
BOR18002
FL27408
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
i
I
I
1
CREEK
TECHNICAL SERVICES, LLC
BORAL ROOFING LLC
Metal Shingles
Slope: 3:12 or greater
Solid or closely fitted min. 15/32 in. plywood sheathing for new and existing construction at
Roof Deck: max. 24 in. span; In the HVHZ, new construction shall be min. 19/32 in. plywood at max.
24 in. span; Designed by others in accordance with FBC requirements. .
Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment
Underlayment: shall be ASTM D 226, Type II installed in accordance with Section 1518.2 or any approved
underlayment for use in the HVHZ.
Nominal No. 2 2x2 SYP wood battens spaced 14-1/2 in. o.c. and oriented perpendicular to
Battens: the wood joists. Battens secured with one (1) #8-11 x 3 in, bugle head wood screw at
each rafter/truss intersection. In the Non-HVHZ, If counter batten/batten installation is
used, refer to COUNTER BATTEN/BATTEN INSTALLATION section of this report.
26 ga. Metal Panel installed as shown in INSTALLATION with five (5) #10-16 x 2 in. HWH
Attachment: corrosion resistant wood screws (four (4) fasteners for Barrel Vault) through the vertical leg
at the headlap beginning at the center of the side lap. Fasteners shall comply with section
1506.6 and 1507.4.4.
Maximum Design -82.6 psf
Pressures: Pn:ssure calculated using 2:1 margin of safety
' r Maximum Mean Roof Heights far Gable/lisp Roofs f
tj
Slopes 2
exposure
96asic Wind Speed (mph} x
'.,160, 170
B 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft. 60 ft 60 ft 60 ft
C 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft
u
D 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft
�,�_. �y,°. done 2 =,Pe_ rimeer
B 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft
C 60 ft 60 ft 60 ft 60 ft 60 ft 1 60 ft 60 ft 60 ft 1 38 ft
D 60 ft 60 ft 60 ft 1 60 ft J 60 ft 1 60 ft 1 60 ft 1 30ft 1 19ft
B 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 44ft 30ft
C 60 ft 60 ft 60 ft 60 ft 60 ft 35 ft 19 ft NA NA
D 60 ft 60 ft 60 ft 60 ft 30 ft NA NA NA NA
Notes: 1) Exposure category for the structure location shall be as defined in the International Building Code 2) Limitations are
based on the exposed area of 10ft2 or less 3) Topographic factors such as escarpments or hills are, not included in the above
assessment 4) Applicable for Enclosed Buildings without overhangs 5) NA = "Not Allowed" 6) Kd = 0.85 7) Projects with mean roof
heights of greater than 60 ft shall be evaluated by a licensed design professional 8) See page 13 for details for dimensions and
locales of Zone 1, 2, and 3 9) V,,,t is shown in the above table. Design pressures are calculated using Veld = V,dt40.6.
For hip roofs 2:12 to 5.6:12, Zone 3 shall be treated as Zone 2
BOR18002
FL27408
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
i
CREEK
TECHNICAL SERVICES, LLC
BORAL ROOFING LLC
Metal Shingles
Slope:
3:12 or greater
Solid or closely fitted min. 15/32 in. plywood sheathing for new and existing construction at
Roof Deck:
max. 24 in. span; In the HVHZ, new construction shall be min. 19/32 in. plywood at max.
24 in. span; Designed by others in accordance with FBC requirements.
Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment
Underlayment:
shall be ASTM D 226, Type II installed in accordance with Section 1518.2 or any approved
underlayment for use in the HVHZ.
Nominal No. 2 2x2 SYP wood battens spaced 14-1/2 in. o.c. and oriented perpendicular to
Battens:
the wood joists. Battens secured with one (1) #8-11 x 3 in, bugle head wood screw at
each rafter/truss intersection. In the Non-HVHZ, If counter batten/batten installation is
used, refer to COUNTER BATTEN/BATTEN INSTALLATION section of this report.
26 ga. Metal Panel installed as shown in INSTALLATION with ten (10) #10-16 x 2 in. HWH
Attachment:
corrosion resistant wood screws (eight (8) fasteners for Barrel Vault) through the vertical
leg at the headlap beginning at the center of the side lap. Fasteners shall comply with
section 1506.6 and 1507.4.4.
Maximum Design
-150 psf
Pressures:
Pressure calculated using 2:1 margin of safety
B 1 60 ft 1 60 ft 1 60 ft 1 60 ft 1 60 ft 1 60 ft 1 60 ft 1 60 ft 1 60 ft
C 1 60 ft 1 60 ft 1 60 ft 1 60 ft 1 60 ft 1 60 ft 1 60 ft 1 60 ft 1 60 ft
B
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
6.0ft
C
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
D
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
.::70ne3.
# W
Corner
Z,K,�� p ;g
B 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft
C 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft+60 ft
D 60 ft 60 ft 60 ft 60 ft 60ft60 ft 60 ft 60 ft50 ft
Notes: 1) Exposure category for the structure location shall be as defined in the International Building Code 2) Limitations are
based on the exposed area of 10ft2 or less 3) Topographic factors such as escarpments or hills are not included in the above
assessment 4) Applicable for Enclosed Buildings without overhangs 5) NA = "Not Allowed" 6) Kd= 0.85 7) Projects with mean roof
heights of greater than 60 ft shall be evaluated by a licensed design professional 8) See page 13 for details for dimensions and
locales of Zone 1, 2, and 3 9) V„ it is shown in the above table. Design pressures are calculated using Veld = VuiA-6.
For hip roofs 2:12 to 5.6:12, Zone 3 shall be treated as Zone 2
BOR18002
FL27408
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
BORAL ROOFING LLC
Metal Shingles
Slope: 4:12 or greater
Solid or closely fitted min. 15/32 in. plywood sheathing for new and existing construction at
Roof Deck: max. 24 in. span; In the HVHZ, new construction shall be min. 19/32 in. plywood at max.
24 in. span; Designed by others in accordance with FBC requirements.
Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment
Underlayment: shall be ASTM D 226, Type II installed in accordance with Section 1518.2 or any approved
underlayment for use in the HVHZ.
26 ga. Granite Ridge installed with seven (7) #9-15 x 1-1/2 in. HWH corrosion resistance
wood screws along back flange of panel as shown below (max. 6-1/4 in. o:c. fastener
Attachment: spacing). Side laps should be staggered a minimum of 9 inches. Fasteners shall
penetrate through the deck a minimum 3/8" and shall comply with section 1506.6 and
1507.4.4.
Maximum Design' - -110 psf
Pressures: Pressure calculated using 2:1 margin of safety per 1504.9
B 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 1 60 ft 1 60 ft 1 60 ft
C 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 1 60 ft 1 60 ft 1 56ft
D 60 ft 60 ft 60 ft 1 60 ft 1 60 ft 1 60 ft 1 60 ft 1 44ft 1 25ft
B 60 ft 60 ft 60 ft 1 60ft 1 60 ft 1 60 ft 1 60 ft 1 57ft 38ft
C 60 ft 60 ft 60 ft 60 ft 1 60 ft 1 40 ft 1 23 ft I NA NA
D 60 ft 60 ft 60 ft 1 60 ft 1 33 ft 1 19 ft I NA I NA NA
Notes: 1) Exposure category for the structure location shall be as defined in the Florida Building Code 2) Limitations are based
on the exposed area of 1 Oft or less 3) Topographic factors such as escarpments or hills are not included in the above assessment
4) Applicable for Enclosed Buildings without overhangs 5) NA = "Not Allowed" 6) Kd = 0.85 7) Projects with mean roof heights of
greater than 60 ft shall be evaluated by a licensed design professional 8) See page 13 for details for dimensions and locales of
Zone 1, 2, and 3 9) Vmt is shown in the above table. Design pressures are calculated usinq Vasa = Vmtg0.6 per 1609.3.1.
For hip roofs 2:12 to 5.6:12, Zone 3 shall be treated as Zone 2
BOR18002 FL27408
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein. ,
. f
f
CREEK
r TECHNICAL SERVICES, LLC
BATTEN/COUNTER BATTEN INSTALLATION (NON-HVHZ ONLY)
BORAL ROOFING LLC
Metal Shingles
The following tables provide requirements for batten/counter batten installations based on design wind load
requirements as defined in Chapter 16 of the FBC. Counter battens shall be minimum No.2 SPF IA dimensional
lumber having the minimum specific gravity specified in the tables below. Battens shall be minimum No. 2 SPF 2x2
dimensional lumber having the minimum specific gravity specified in the tables below.
Batten and Counter Batten Spacing and Fastener Requirement for Reroofing with Counterbatten and Rafter of Specific Gravity z 0.36
nd�
Type
Roof Type and Slope
Gable Roof Slope 3:12 to 6.1:121
Gable
Roof Slop a >6.1:12 to 12:12
Zone 1
Zone 2
Zone
3
Zone
1
Zone 2& 3
Speed
(mph)
Exposure
B
C
B
C
B
C
B
C
B
C
Fastene?
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
#6
5100
Batten'
2
1
2
1
2
1
2
1
2
2
2
2
2
1
2
1
2
1
2
1
Counterbatten = 1.25" 4
14
14
14
14
14
14
14
14
10
14
10
14
14
14
14
14
14
14
14
14
Counterbatten = 1.00,,4
14
14
14
14
14
14
14
14
10
14
10
14
14
14
14
14
14
14
14
14
I
Counterbatten = 0.75" 4
14
14
14
14
10
14
10
14
7
10
7
10
14
14
14
14
14
14
14
14
110
Batten
2
1
2
1
2
2
2
2
3
2
3
2
2
1
2
1
2
1
2
1
Counterbatten = 1.25" 4
14
14
14
14
14
14
14
14 1
10 1
14
10
14
14
14
14
14
14
14
14
14
Counterbatten = 1.00..)4
14
14
14
14
10
14
10
14
7
10
7
10
14
14
14
14
14
14
14
14
Counterbatten = 0.75" 4
14
14
14
14
7
10
7
10
4
7
4
7
14
14
14
14
10
14
10 1
14
120
Batten
2
1
2
1
2
2
2
2
3
2
3
2
2
1
2
1
2
1
2
1
Counterbatten = 1.25,,4
14
14
14
14
10
14
10
14
7
14
7
14
14
14
14
14
14
14
14
14
Counterbatten = 1.00,,4
14
14
14
14
10
14
10
14
7
10
7
10
14
14
14
14
14
14
14
14
Counterbatten = 0.75" 4
10
14
10
14
7
10
7
10
4
7
4
7
10
14
10
14
10
14
10
14
130
Batten'
2
1
2
1
3
2
3
2
4
3
4
3
2
1
2
1
2
2
2
2
Counterbatten = 1.25" 4
14
14
14
14
10
14
10
14
7
10
7
10
14
14
14
14
14
14
14
14
Counterbatten = 1.0o..)4
14
14
14
14
7
10
7
10
4
7
4
7
14
14
14
14
10
14
10
14
Counterbatten = 0.75',4
10
14
10
14
4
7
4
7
4
4
4
4
10
14
10
14
7
10
7
10
140
Batten'
2
1
2
1
3
2
3.
2
4
3
4
3
2
2
2
2
2
2
2
2
Counterbatten = 1.25..4
14
14
14
14
10
14
10
14
4
10
4
10
14
14
14
14
10
14
10
14
Counterbatten = 1.00i4
10
14
10
14
7
10
7
10
4
7
4
7
10
14
10
14
10
14
10
14
Counterbatten = 0.75..)4
10
14
10
14
4
7
4
7
4
4
4
4
7
10
7
10
7
10
7
10
150
Batten3
2
2
2
2
3
2
3
2
5
3
5
3
2
2
2
2
3
2
3
2
Counterbatten = 1.25,,4
14
14
14
14
7
14
7
14
4
10
4
10
10
14
10
14
10
14
10
14
Counterbatten = 1.00,.4
10
14
10
14
4
7
4
7
4
4
4
4
10
14
10
14
7
10
7
10
Counterbatten = 0.75" 4
7
10
7
10
4
7
4
7
NA
4
NA
4
7
10
7
10
7
10
7
10
160
Batten
2
2
2
2
4
3
4
3
5
4
5
4
3
2
3
2
3
2
3
2
Counterbatten = 1.25..)4
10
14
10
14
7
10
7
10
4
7
4
7
10
14
10
14
10
14
10
14
Counterbatten = 1.00,,4
10
14
10
14
4
7
4
7
4
4
4
4
7
10
7
10
7
10
7
10.
Counterbatten = 0.75" 4
7
10
7
10
4
4
4
4
NA
4
NA
4
7
10
7
10
4
7
4
7
170
Batten3
3
2
3
2
4
3
4
3
6
4
6
4
3
2
3
2
3
2
3
2
Counterbatten = 1.25.,4
10
14
10
14
4
10
4
10
4
7
4
7
10
14
10
14
7
14
7
14
Counterbatten = 1.00..)4
7
10
7
10
4
7
4
7
NA
4
NA
4
7
10
7
10
7
10
7
10
Counterbatten = 0.75" 4
4
10
4
10
4
4
4
4
NA
NA
NA
NA
4
7
4
7
4
7
4
7
180
Batten
3
2
3
2
4
1 3
1 4
3
6
5
6
5
3
2
3
2
3
3
3
3
Counterbatten = 1.25i4
10
14
1 10
14
4
1 10
1 4
10
4
7
4
7
7
14
7
14
7
14
7
14
Counterbatten = 1.00,,4
7
10
1 7
10
4
1 4
1 4
4
NA
4
NA
4
7
1 10
7
10
4
7
4
7
Counterbatten = 0.75" 4
4
7
1 4
7
NA
1 4
1 NA
4
NA
I NA
NA
NA
4
1 7
4
1 7
1 4
7
1 4
7
Notes: 1) For hip roofs between 3:12 and 5.6:12 Zone 3 shall be treated as Zone 2
2) The batten and counter batten fasteners shall minimum 16d x 3.5-inch ring shank nails and #8 x 3-inch wood screws
3) For batten to counter batten attachment, the number of fasteners at each intersection are shown for each wind load
condition
4) For counter batten to rafter/truss attachment, the fastener spacings along each counterbatten are shown for each wind
load condition. The counter batten fastener shall penetrate into the rafter/truss a minimum distance (p) as shown on
the table
5) NA = not applicable
BOR18002
FL27408
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
1 This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
I
1 CREEK
TECHNICAL SERVICES, LLC
BORAL ROOFING LLC
Metal Shingles
Batten and Counter Batten Spacing and Fastener Requirement for Reroofing with Counterbatten and Rafter of Specific Gravity 2 0.5
Ult.
Wind
Speed
Type
Roof Type and Slope
Gable Roof Slope 3:12 to 6.1:121
Gable Roof Slope >6.1:12 to 12:12
Zone 1
Zone 2
Zone 3
Zone 1
Zone 2& 3
(mphj
Exposure
B
C
B
C
B
C
B
C
B
C
Fastener
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
5100
Batten
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
Counterbatten = 1.25,,4
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
Counterbatten = 1.00,.4
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
Counterbatten = 0.75" 4
14
14
14
14
10
14
10
14
7
14
7
14
14
14
14
14
14
14
14
14
110
Batten
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
Counterbatten = 1.25'.4
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
Counterbatten = 1.00,,4
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
I
Counterbatten = 0.75,,4
14
14
14
14"
14
14
14
14
10
14
10
14
14
14
14
14
14
14
14
14
120
Batten
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
Counterbatten = 1.25i4
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
Counterbatten = 1.00,,4
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
Counterbatten = 0.75" 4
14
14
14
14
14
14
14
14
10
14
10
14
14
14
14
14
14
14
14
14
130
Batten
2
1
2
1
2
1
2
1
2
2
2
2
2
1
2
1
2
1
2
1
Counterbatten = 1.25" 4
14
14
14
14
14
14
14
14
14
14
14
14,
14
'14
14
14
14
14
14
14
Counterbatten = 1.0o..)4
14
14
14
14
14
14
14
14
10
14
10
14
14
14
14
14
14
14
14
14
Counterbatten = 0.75"4
14
14
14
14
10
14
10
14
7
10
7
10
14
14
14
14
14
14
14
14
140
Batten
2
1
2
1
2
1
2
1
2
2
2
2
2
1
2
1
2
1
2
1
Counterbatten = 1.25..)4
14
14
14
14
14
14
14
14
10
14
10
14
14
14
14
14
14
14
1 14
14
Counterbatten = 1.00,,4
14
14
14
14
14
14
14
14
10
14
10
14
14
14
14
14
14
14
14
14
Counterbatten = 0.75',4
14
14
14
14
10
14
10
14
7
10
7
10
14
14
14
1 14
14
14
14
14
150
Batten3
2
1
2
1
2
1
2
1
3
2
3
1 2
2
1
2
1
2
1
2
1
Counterbatten = 1.25'.4
14
14
14
14
14
14
14
14
10
14
10
14
14
14
14
14
14
14
14
14
Counterbatten = 1.00" 4
14
14
14
14
10
14
10
14
7
10
7
10
14
14
14
14
14
14
14
14
Counterbatten = 0.75" 4
14
14
14
14
10
14
10
14
4
7
4
7
14
14
14
14
14
14
14
14
160
Batten
2
1
1 2
1
2
2
2
2
3
2
3
2
2
1
2
1
2
1
2
1
Counterbatten = 1.25,,4
14
14
14
14
14
14
14
14
10
14
10
14
14
14
14
14
14
14
1 14
1 14
Counterbatten = 1.00,,4
14
14
14
14
10
14
10
14
7
10
7
10
14 .
14
14
14
14
14
14
14
Counterbatten = 0.75,,4
14
14
14
14
7
10
7
10
4
7
4
7
14
14
14
1 14
10
14
10
14
170
Batten
2
1
2
1
2
2
2
2
3
2
3
2
2
1
2
1
2
1
2
1
Counterbatten = 1.25.,4
14
14
14
14
10
14
10
14
7
14
7
14
14
14
14
14
14
14
14
14
Counterbatten = 1.00,,4
14
1 14
14
14
10
14
10
14
7
10
7
10
14
14
14
14
14
14
14
14
Counterbatten = 0.75,.4
10
14
10
14
7
10
7
10
4
7
4
7
10
14
10
14
10
14
10
14
180
Batten'
2
1
2
1
3
2
1 3
1 2
1 3
1 3
3
3
2
1
1 2
1
2
1 2
2
2
Counterbatten = 1.25i4
14
14
14
14
10
14
10
14
7
10
7
10
14
1 14
14
14
14
14
14
1 14
Counterbatten = 1.0o..)4
14
14
14
14
7
10
7
10
4
7
4
7
14
14
14
1 14
10
14
10
14
Counterbatten = 0.75i4
10
14
10
14
1 7
10
1 7
10
4
4
4
4
10
14
10
1 14
7
10
7
10
Notes: 1) i-or nip roots between ;3:1L ana 5.b:11 Lone 3 shall be treated as Lone "L
2) The batten and counter batten fasteners shall minimum 16d x 3.5-inch ring shank nails and #8 x 3-inch wood screws
3) For batten to counter batten attachment, the number of fasteners at each intersection are shown for each wind load
condition
4) For counter batten to rafter attachment, the fastener spacings along each counter batten are shown for each wind load
condition. The counter batten fastener shall penetrate into the rafter a minimum distance (p) as shown on the table
I
BOR18002 FL27408
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Gable
Hip
IA
BORAL ROOFING LLC
Metal Shingles
2 1 2
,3 2 3
3 2 3 a
2 1 2
Dimension "a" shall be 10% of the least horizontal dimension or (0.4 x Mean Roof Height), whichever is smaller, but
not less than either 4% of the least horizontal dimension or 3ft.
LIMITATIONS
1. Fire classification is not within the scope of this evaluation.
2. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3. Reroofing shall be in accordance with FBC Section 1511 outside the HVHZ or Section 1521 within the
HVHZ.
4. Installation of the evaluated products shall comply with this report, the FBC and RAS 133 in the HVHZ, and
the manufacturer's published application instructions. Where discrepancies exist between these sources,
the more restrictive and FBC compliant installation detail shall prevail.
5. All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
REFERENCES
Entity
Report No.
'Standard
Year
PRI Construction Materials Technologies (TST5878)
BORR-099-02-01A
ASTM B 117
2016
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
BORR-099-02-01 B
ASTM G 155
2005a
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
BORR-099-02-01C
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
BORR-099-02-01 D
UL 580
2006
UL1897
2012
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
BORR-099-02-01 E
UL 580
2006
UL1897
2012
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
BORR-099-02-01 F
ASTM E 8
PRI Construction Materials Technologies (TST5878)
BORR-099-02-01 G
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
GRT-007-02-01
ASTM B 117
2016
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
GRT-008-02-01
ASTM G 155
2005a
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
GRT-022-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
GRT-026-02-01
UL 580
2006
UL1897
2012
TAS 125
2003
CREEK Technical Services, LLC
Anchorage
ASCE 7
2010
Calculations
ANSI/AWC NDS
2015
BOR18002 FL27408
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
>` CREEK BORAL ROOFING LLC
Metal Shingles
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
`,`,���Yt IR
%%% G� j,P .....
J-EN`sF'�Sj��.
No 74021
1
L STATE OF/
41
�.
41iIn1N�l
CERTIFICATION OF INDEPENDENCE
*,.. M. 2018.06.14
11:43:19
ucmM�Web=sen0.nr a.�x•w .. ....
_041001
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
I
END OF REPORT
BOR18002 FL27408
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.