Loading...
HomeMy WebLinkAboutGENERATOR PAPERWORKINCLUDES: • True Power"' Electrical Technology • Two Line LCD Multilingual Digital EvolutionT" Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp Pre -Wired Switch or 200 Amp Service Rated Switch. See Page 4 for Details. • Electronic Governor • External Main Circuit Breaker, System Status & Maintenance Interval LED Indicators • GFCI Duplex Outlet • Sound Attenuated Enclosure • Flexible Fuel Line Connector • Composite Mounting Pad • Natural Gas or LP Gas Operation CENTURION® SERIES Dnnielnn�inl ��nr�rilr�•r i�nnnrn�nrn Standby Power Rating Model 006256-1 & 006257-3 (Steel - Gray) - 16 kW 60 Hz Model 006258-3 (Steel - Gray) - 20 kW 60 Hz Model 006553-2 (Aluminum - Gray) - 22 kW 60— z C-- LISTED L-JU11:1 tt:o t • 5 Year Limited Warranty Note: CUL certification only applies to unbundled units and units packaged with pre -wired switches. Units packaged with the Smart Switch are UL certified in the USA only. • Capability to be installed within 18" (457 mm) *Only if located away from doors, windows and fresh air intakes, and unless other - of a building* wise directed by local codes. FEATURES O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC'S success in "IMPROVING POWER BY DESIGN." But it doesn't stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at -+1%. O 'TRUE. POWERT' ELECTRICAL TECHNOLOGY: Superior harmonics 0 SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer and sine wave form produce less than 5% Total Harmonic Distortion for network provides parts and service know-how for the entire unit, from the utility quality power. This allows confident operation of sensitive electronic engine to the smallest electronic component. equipment and micro -chip based appliances, such as variable speed HVAC systems. O GENERACw TRANSFER SWITCHES. Long life and reliability are O TEST CRITERIA: synonymous with GENERAC POWER SYSTEMS. One reason for this PROTOTYPE TESTED NEMA M61-22 EVALUATION confidence is that the GENERAC product line includes its own transfer SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY systems and controls for total system compatibility. w GENERACQO ,� .� T 1JSALL O -•L� * * Mobil`, t— PROMISELink 16/20/22 kW Engine GENERAC@ Centurion Series features and benefits • Generac (OHVI) design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • Quiet Test'" Greatly reduces sound output and fuel consumption during bi-weekly exercise, compared to other brands. •"Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. •Full'pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. -Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. -High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. -Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. -Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch • Fully automatic Transfers your vital electrical loads to the energized source of power. • Pre -wired, color -coded conduits Ensures the easiest, trouble -free installation. (Pre -fired switches only) • Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution'"' Controls -Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. -Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. -Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 60% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exerciser Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibilty and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. • Electronic governor Maintains constant 60 Hz frequency. Unit -SAE weather protective enclosure Sound attenuated enclosure ensures quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building." Installation System • 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. -Composite mounting pad Eliminates the need to pour a concrete pad unless required by local municipalities. GENERACW Centurlon Series 16/20/22 kW specifications Generator Modell 006256-1, 006257-3 (16 kW) 006258-3 (20 kW) 006553-2 (22 kW) F elit#i#1 Gratflr�wte Faei P yx 16 0001Nar Wait5w° ' ;:22D00.Waifs* Maximum Continuous Power Capacity (NG) 16,000 Walls* 18,000 Watts* 19,500 Watts' '. °„ ta//� ;:�� OEM ;, �_ '"��,,,. a `�:+"+`+"+9 z�4t) 2,r flE C . ".' ��� y ,, ., .- Rated Maximum Continuous Load Current — 240 Volts (LP/NG) 66.6/66.6 83.3/75 91.6/81.3� f) 3# r1#oflrlll5tnrt#Qt1°.` tLesstffatl:5 RRE , " ;'.Less111ian5r,.", ro lestlin:"5; Main Line Circuit Breaker 65 Amp 90 Amp 100 Amp ;;Phase a a ` , Number of Rotor Poles 2 2 2 (�lla#et q er#CY F� 601Iz , .,� x � ,. 60"Hz Power Factor , 1.0 1.0 1.0 atety�� rer#1tr# : 'ft� 91 _ �� ' � � �,-, _,� ��.,�,.� � ,� ? � . , � :, g; ��*tfp:•26R12 Uo ts'a'nd 5�5 CC�;A Mlnrmu u.�' '�,,,�,,. �x Unit Weight (lb/kg) 471/213 6 451/204 6 426/238 6 :. ��„ W$`• �� 48 G2�. 5d.,.x•29 ,121£j, 6 8 K732 Sound ;output in dB(A) at 23 It (7 m) with generator operating at normal load** 66 66 67 oundt io dB " dnor or rn& ttre t y �� f Exercise Duration 5 min 5 min 5 min Engine of,E ` jrte" 3s .feGENE(i#tG' OKVi V, . N.' GE[VRaly'QNt(i 1hTtN(N j y , D. ". 7,Ff IERAC i?#iV��V ITW i �71me x _� Number of Cylinders 2 2 2 Cylinder Block Aluminum w/ Cast Iron Sleeve Aluminum w/ Cast Iron Sleeve Aluminum w/ Cast Iron Sleeve fi , iiCt $tfte ¢° na„' yi ` sx . Lt# Eifi,1I7IYu d ,� IY$ ` a y. �. ,71 Ignition', System Solid-state w/ Magneto Solid-state w/ Magneto Solid-state w/ Magneto rn rfS item, =�3 ,, �.... ,;°' ecE"ram b x,lecironr�,: eE f�niG94° ,a,. �. Compression Ratio 9.5:1 9.5:1 9.5:1 Oil Capacity Including Filter Approx. 1.9 gV1.8 L Approx. 1.9 gI/1.8 L Approx. 1.9 gI/1.8 L L ffi 7 Fuel Cdnsumption Natural Gas W/hr (m3/hr) 1/2 Load 193 (5.47) 205 (5.8) 184 (5.21) Full Load 312 (8.83) 308 (8.72) 281 (7.96) Liquid Propane 0/hr (gal/hr) (Vhr] 1/2 Load 69.2 (1.9) [7.2] 75.6 (2.08) [7.87] 83 (2.16) [8.16] Mode Buttons: Auto Automatic Start on Utility failure. Programmable exercise. eUd 8 . . �x .;Wn 'iarf w�ftt sla are f Qi urn sfa s on f`uti#i faits; iransfer"t+rttp#aCQ. Off Stops unit. Power is removed. Control and charger still operate. iatlyloR n, f��;4, z-. Slaptlard -.a ,.M Engine Run Hours Indication Standard y 9.; Utility Voltage Loss/Return to Utility Adjustable (Brownout Setting) From 140-171 V/190-216 V °° ur S to ps #e Ezlt tQ,#5�1Ql ri t tlt#SE � " y W Run/Ala m/Maintenance Logs 50 Events Each I set Qht,7"lust {DeG Starter Lock -out Starter cannot re-engage until 5 sec. after engine has stopped. Charger FaulVMissing AC Warning Standard .�.� m_,,�..,,,_.�.,�,.-„„,„„,�•�°�...°.-,mow.. � t QY effe" fSie �tti}z a1lr [K#igr( ' r€ flirt '� a -', ,f '3tafiila[d r ti, A �s Automatic Voltage Regulation with Over and Under Voltage Protection Standard Ur1d r> . 'Q f i1Q2 f rft:f? AtCQ GR. ` .. s v"5 ! r x. Standard- P , c , a Safety Fused/Fuse Problem Portection Standard Overcrarik/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown Standard _,.,.... '. �,w "t3;tm x sxs.a etas&sef^"-�°.?" , taliEard s�. s.,,,.,v"``° « �,Fr.�:• . -auf 's..,.._'a`*O",A_mz.,.,..,__.,,.F.,.�„a, ._..,_...HH..._..._.»„�.�`-" Internal aulVlncorrect Wiring Protection {Standard •3T w' / L.0 a{ Y ff6,�b 3 ..� ; 7,77„"UtadRrd, kR, .:F„ yet,r Field Upgradable Firmware Standard **Sound !levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby: Applicable fnr nunnluin......—, n .w fnr tho 1.,-tinn of thn nfi l ih, — r nnfann AIn nvnrinad r Mlih, in mnilahln fnr fhio -tine I II -tin— in •,nnn 1,i ,ifh RCF61 A iemnAA and Nhir9711 * f,A—i-u GENERAC Centurion Series 16/20/22 kW switch options Pre -Mired Features available on 16 kW model only • Electrically operated, mechanically -held contacts for fast, positive connections. • Rated for all classes of load,100% equipment rated, both inductive and resistive • 2 pole, 250 VAC contactors. • 30 millisecond transfer time. • Dua[ coil design. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA 1 (indoor rated) enclosure is standard on the 100 amp switch. • Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effective install. • Pre -wired 30 foot (9.1 meter) whip to connect to the provided 5 foot (1.5 meter) pre -wired whip and external connection box. • Pre -wired 2 foot (0.61 meter) whip, color coded to connect into the existing electrical panel. Dimensions Model 006256-1 (16 I(W) Current Rating (Amps) 100 p Utility Voltage Monitor (Fixed)* -Pick-up 80% -Dropout 65% Exerciser bi-weekly for 12 minutes* Standard j) �;{[�{ r�}.j 1 ,q'•Y. fir. 3.3Jt..P.F�.,,,.,y.'Cw,x4?.......G'�.w..kc. Total of Pre -wired Circuits 16 No. 15A120V 5 No. 20 A 120 V 5 No. 20 A 240 V 1 No. 30 A 240 V - No. 40 A 240 V 1 No. 50 A 240 V 1 Circuit Breaker Protected Available RMS Symmetrical Fault Current @ 250 Volts 10,000 *Function of Evolution Controller t Can be set to weekly or monthly Mechanical Dimensions Height Width Depth H1 H2 W1 W2 in 23.5 26.4 8.3 12.6 6.3 mm 597 671.7 211 320.7 159.6 Wire Ranges Conductor Lug Neutral Lug Ground Lug 2/0-#14 210-#14 2/0-#14 Service.Rated Switch Features • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2 pole, 250 VAC contactors. • Service equipment rated,.dual coil design. • Rated for both aluminum and copper conductors. • NEMA/UL 311 aluminum outdoor enclosure. • Main contacts are silver plated or silver all oy to resist welding and sticking. Dimensions 200 Amps 120/240, is Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 27.24 1 30.0 11.4 13.5 7.09 mm 692.0 1 762.4 289.0 343.0 180.0 Model 006257-3 (16 kW) 006258-3 (20 kW) 006553-2 (22 kW) Current Rating (Amps) 200 Utility Voltage Monitor (Fixed)* -Pick-up 80% -Dropout 65% Exercise week) for 12 minutes* Standard t d0r Enclosure Type NEMA/UL 3R Lug Range 250 MGM - #6 *Function of Evolution Controller GENERAC Centurion Series 16/20/22 kW available accessories tlth' �lCt �a d " �OSGfICID �;1,75M a Generac's Mobile Link allows you to check the status of your generator from anywhere that you have access to an Internet connection from a PC or with any smart device. You will even be 006463-3 Mobile Link- notified when a change in the generator's status occurs via e-mail or text message. Available in the U.S. only. Every standby generator requires a battery to start the system. Generac offers the recommended 005819-0 26R Wet Cell Battery 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact®). If the temperature regularly falls below 32 IF (0 °C), a cold weather kit is required to maintain 006212-0 Cold Weather Kit optimal battery and oil temperatures. Kit consists of a battery warmer and oil filter heater with built-in thermostats. Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electri- 005621-0 Contact Kit cal load you may not need. Not compatible with 50 amp pre -wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators. This 005666-0 Fascia Base Wrap Kit offers a sleek, contoured appearance as well as offering protection from rodents and insects by (Standard on 22 kW) covering the lifting holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect 005704-0 Paint Kit from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. 006484-0:16 kW Generac's scheduled maintenance kits provide all the hardware necessary to perform complete 006485-0: 20 & 22 kW Scheduled Maintenance Kit routine maintenance on a Generac automatic standby generator. Completely wireless and battery powered, Generac's wireless remote monitor provides you with 006664-0 Wireless Remote Monitor instant status information without ever leaving the house. Not compatible with Centurion*" ES systems. Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to 006873-0 increase its power management capabilities. It provides additional power management flexibility I (50 Amps) not found in any other power management system. dimensions & PCs Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. izo.o mi LEFT SIDE VIEW FRONT VIEW Model UPC 006256-1 696471062564 006257-3 696471062571 006258-3 696471062588 006553-2 696471065530 GENERAC Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2016 Generac Power Systems, Inc. All dahts reserved. All specifications are subiect to chance without notice. Bulletin OK8459-F 02/12/16