Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFu i= 4-4:t::7, FOR405-2017 L Kul ` 81 V -C) el(P FLORM RIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method RECEIVED Project Name: REED RESIDENCE Builde Name: DAVE GOLDEN HOMES, INC. �CAN Street: SLASH PINE TRAIL Permi Office: ST LUCIE COUNTY NCI) City, State, Zip: FORT PIERCE, FL, 34951 NOV 0 7 2018 Permii Number: BY Owner: Judsd lion: ST LUCIE COUNTY a �l Lucie County Desigi Location: FL, Fort Pierce °IR I,�l! le �1L�Fi l P'p(I't11$ R411 St. Lucie (Florida Climate Zone 2 ) I 1. New construction or existing New (From Plans) 9. Wall Types(1694.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior b. Frame Wood, Adjacent R=4.1 1446.00 ft2 - R=11.0 248.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is thi� a worst case? No 10. Ceiling Types (2228.0 sqft.) Insulation Area a. Under Attic (Vented) R=38.0 2228.00 ft2 6. Condiitioned floor area above grade (ftz) 2228 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/Aucts R _ z f 11 R ft2 7. Windows(255.7 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU CLST 6 175 a. U-Factor: Sgl, U=0.65 189.00 ft2 SHIGC: SHGC=0.25 b. U-Factor: Sgl, U=0.70 66.67 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 i a. Central Unit 40.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.333 ft. Area Weighted Average SHGC: 0.263 14. Hot water systems I a. Electric Cap: 50 gallons 8. Floor Types (2228.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2228.00 ft2 b. Conservation features b. N/A I R= ft2 None c. N/A 1 R= ft2 15. Credits None Glass/FIor Area: 0.115 Total Proposed Modified Loads: 66.02 PASS � Total Baseline Loads: 66.90 1 hereby that the plans and specifications covered by Review of the plans and O�T$E �ertify this calculation are in compliance with the Florida Energy specifications covered by this Code calculation indicates compliance with the Florida Energy Code. rr•l%" PREPARR.11 Ry.Before DATE: A construction is completed this building will be inspected for compliance with Section 553.908 a * m. I hereby certify that this building, ' compliance Florida Statutes. with the Florida Energy Code. 7gnis COD WE OWNER%AGENT• BUILDING OFFICIAL: DATE: 2y I y DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Complia'nce requires an' Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope I leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). i I I 8128/20181I10:24 AM I I i EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6 i FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: ! REED RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2228 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: DAVE GOLDEN HOMES, IN Rotate Angle: 0 Street: SLASH PINE TRAIL Permili Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, FamilyI Type: Single-family FL, 34951 New/sting: Exillent: New (From Plans) Comm I � I CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V I Design r Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range 1 FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low i BLOCKS Number Name Area Volume 1 Entire House 2228 18510 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated i 1 I MASTER BEDROO 343 3430 No 0 1 1 Yes Yes Yes I 2 M CLST 2 21 168 No 0 1 No Yes Yes 3 I M CLST 1 28 224 No 0 1 Yes Yes Yes 4 I M BATH 156 1248 No 0 1 Yes Yes Yes 5 I M TOILET 18 144 No 0 1 No Yes Yes 6 UTILITY ROOM 60 480 No 0 1 No Yes Yes 7 AHU CLST 12 96 No 0 1 No Yes Yes 8 HALLWAY 69 552 No 0 1 No Yes Yes 9 I KITCHEN 309 2472 Yes 0 1 Yes Yes Yes 10 i FAMILY ROOM 312 2496 No 0 1 Yes Yes Yes 11 DINING 228 1824 No 0 1 Yes Yes Yes 12 I FOYER 114 912 No 0 1 Yes Yes Yes 13 BEDROOM 2 181 1448 No 0 1 1 Yes Yes Yes 14 I CLST 2 18 144 No 0 1 Yes Yes Yes 15 BATH 2 99 792 No 0 1 Yes Yes Yes 16 CLST 3 18 144 No 0 1 Yes Yes Yes 17 BEDROOM 3 182 1456 No 0 1 1 Yes Yes Yes 18 �1 HALL 60 480 No 0 1 No Yes Yes I I 8/28/2018110:24 AM I I I EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 6 FORM IR405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS I # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 39 ft 0 343 ft2 — 1 0 0 I 2 Slab -On -Grade Edge Insulatio M CLST 2 1 ft 0 21 ft2 e 1 0 0 I 3 Slab -On -Grade Edge Insulatio M CLST 1 7 ft 0 28 ft2 e 1 0 0 4 Slab -On -Grade Edge Insulatio M BATH 12 ft 0 156 ft2 e 1 0 0 I 5 Slab -On -Grade Edge Insulatio M TOILET 1 ft 0 18 ft2 — 1 0 0 I 6 Slab -On -Grade Edge Insulatio UTILITY ROOM 1 ft 0 60 ft2 e 1 0 0 I 7SIab-On-Grade Edge Insulatio AHU CLST 1 ft 0 12 ft2 e 1 0 0 8Slab-On-Grade Edge Insulatio HALLWAY 1ft 0 69ft2 e 1 0 0 I 9Slab-On-Grade Edge Insulatio KITCHEN 13 ft 0 309 ft2 e 1 0 0 i I 10SIab-On-Grade Edge Insulatio FAMILY ROOM 13 ft 0 312 ft2 — 1 0 0 I 11Slab-On-Grade Edge Insulatio I DINING 12 ft 0 228 ft2 e 1 0 0 12SIab-On-Grade Edge Insulatio I FOYER 6 ft 0 114 ft2 e 1 0 0 13SIab-On-Grade Edge Insulatio i BEDROOM 2 27 ft 0 181 ft2 e 1 0 0 I 14SIab-On-Grade Edge Insulatio I CLST 2 2 ft 0 18 ft2 — 1 0 0 15SIab-On-Grade Edge Insulatio I BATH 2 11 ft 0 99 ft2 — 1 0 0 16SIab-On-Grade Edge Insulatio I CLST 3 2 ft 0 18 ft2 — 1 0 0 17SIab-On-Grade Edge Insulatio I BEDROOM 3 27 ft 0 182 ft2 _ 1 0 0 18SIab-On-Grade Edge Insulatio I HALL 1 ft 0 60 ft2 — 1 0 0 I i ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) I 1 Hip Composition shingles 2413 ft2 0 ft2 Medium 0.6 No 0.9 No 0 22.6 ATTIC ,/ II V I # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2228 ft2 N N 8/28/2018110:24 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6 I FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT I CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 38 Blown 343 ft2 0.1 Wood I 2 Under Attic (Vented) M CLST 2 38 Blown 21 ft2 0.1 Wood 3 Under Attic (Vented) M CLST 1 38 Blown 28 ft2 0.1 Wood i 4 Under Attic (Vented) M BATH 38 Blown 156 ft2 0.1 Wood 5 Under Attic (Vented) M TOILET 38 Blown 18 ft2 0.1 Wood i I 6 Under Attic (Vented) UTILITY ROOM 38 Blown 60 ftz 0.1 Wood I 7 Under Attic (Vented) AHU CLST 38 Blown 12 ftZ 0.1 Wood 8 Under Attic (Vented) HALLWAY 38 Blown 69 ftZ 0.1 Wood 9 Under Attic (Vented) KITCHEN 38 Blown 309 ft2 0.1 Wood 10 Under Attic (Vented) FAMILY ROOM 38 Blown 312 ft2 0.1 Wood 11 Under Attic (Vented) DINING 38 Blown 228 ft2 0.1 Wood 12 Under Attic (Vented) FOYER 38 Blown 114 ft2 0.1 Wood 13 Under Attic (Vented) BEDROOM 2 38 Blown 181 ft2 0.1 Wood 1 14 Under Attic (Vented) CLST 2 38 Blown 18 ft2 0.1 Wood I 15 Under Attic (Vented) BATH 2 38 Blown 99 ft2 0.1 Wood 1 16 Under Attic (Vented) CLST 3 38 Blown 18 ft2 0.1 Wood 17 I Under Attic (Vented) BEDROOM 3 38 Blown 182 ft2 0.1 Wood 18 Under Attic (Vented) HALL 38 Blown 60 ft2 0.1 Wood WALLS 1 Adjacent viCaty Width Height Sheathing Framing Solar Below SpaceArpn le Et Frnr-finn, 1 N Exterior Concrete Block - Ext InsMINSTER BE 4.1 3 0 10 0 30.0 ft2 0 0 0.6 0 2 S Exterior Concrete Block - Ext InsMASTER BE 4.1 21 0 10 0 210.0 ft2 0 0 0.6 0 3 W Exterior Concrete Block - Ext InsMASTER BE 4.1 15 0 10 0 150.0 ft2 0 0 0.6 0 4 S Exterior Concrete Block - Ext Insu#A CLST 1 4.1 7 0 8 0 56.0 ft2 0 0 0.6 0 5 S Exterior Concrete Block - Ext InsulM BATH 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 6 i W Exterior Concrete Block - Ext InsuKITCHEN 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 7 W Exterior Concrete Block - Ext InCAMILY ROO 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 8 E Exterior Concrete Block - Ext Insul DINING 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 9 E Exterior Concrete Block - Ext Insul FOYER 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 10 N Exterior Concrete Block - Ext InfiffDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 11 I E Exterior Concrete Block - Ext InfiffDROOM 2 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 _ 12 II N Exterior Concrete Block - Ext Insul CLST 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 13 I N Exterior Concrete Block - Ext Insul BATH 2 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 14 N Exterior Concrete Block - Ext Insul CLST 3 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 15 i N Exterior Concrete Block - Ext InfiffDROOM 3 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 _ 16 W Exterior Concrete Block - Ext InfiffDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 17 E Garage Frame - Wood UTILITY RO 11 23 8 184.0 ft2 0 0.25 0.600000 0 18 I S Garage Frame - Wood DINING 11 8 8 64.0 ft2 0 0.25 0.600000 0 I I I 8/28/2018 10:24 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 6 • I FORM IR405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. I Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 3 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 1 ft 4 in 1 ft 4 in None None 2 S 5 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft' 1 ft 4 in 1 ft 4 in None None I 1 3 W 6 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 1 ft 4 in 1 ft4 in None None 4 W 6 Metal Low-E Single Yes 0.7 0.3 N 20.0 ft2 1 ft 4 in 1 ft 4 in None None 1 5 I W 7 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 1 ft 4 in 1 ft 4 in None None 6 W 7 Metal Low-E Single Yes 0.7 0.3 N 20.0 ft2 1 ft 4 in 1 ft 4 in None None 1 7 E 8 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 1 ft 4 in 1 ft 4 in None None 8 E 9 Metal Low-E Single Yes 0.7 0.3 N 6.7 ft2 1 ft 4 in 1 ft 4 in None None 9 E 9 Metal Low-E Single Yes 0.7 0.3 N 20.0 ft2 1 ft 4 in 1 ft4 in None None 10 E 11 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 1 ft 4 in 1 ft 4 in None None 11 N 13 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 1 ft 4 in 1 ft 4 in None None 12 W 16 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 ft 4 in 1 ft 4 in None None j GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 I 506 ft2 506 ft2 2B ft 8 ft 11 I INFILTRATION I # Sicope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Who ilehouse Proposed ACH(50) .00037 2159.5 118.55 222.96 .2708 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPI 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts i 1 Central Unit/ Split SEER: 16 40 kBtu/hr 1200 cfm 0.8 1 sys#1 I HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None I SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 I I I I I I I I 8/28/2018 j10:24 AM I I EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6 FORM IR405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS — Supply — — Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool f 1 Attic 6 175 ft2 Attic 18 ft2 Default Leakage AHU CLST (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Coolin Jan Feb Heating Jan Feb Mar Mar A r f Apr f Me M y Jun f Jun Jul f Jul Au Aug n Se Sep[]Oct [ ]Oct Nov Nov Dec Dec Ventin Jan Feb Mar [X] A r [ Ma [ Jun [ Jul Au Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling I(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 1 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 i PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 - 68 68 68 68 i PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 1 PM 68 68 68 68 68 68 68 68 68 68 68 68 I MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 ` M CLST 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft = 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 UTILITY ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 FAMILY ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER D'fault(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 D {fault(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/s .ft. ft2 ft 0.3 HALL I Name: I Rating Compant: I I I I i i 8/28/2018 0:24 AM I EnergyGauge® USA Section R405.4.1 Compliant Software i Page 6 of 6 i 20117 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA i TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: REED RESIDENCE Builder Name: DAVE GOLDEN HOMES, INC. Street: SLASH PINE TRAIL Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: Y U Olwner: Jurisdiction: ST LUCIE COUNTY = Design Location: FL, Fort Pierce U I COIMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall i The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. I Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit I insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls) The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the .cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. i Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors I The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation I Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrowlcavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building Ibe sealed to the drywall. thermal envelope shall be air tight and IC rated. PlumbinIg and wiring Batt insulation shall be cut neatly to fit around wiring a I plumbing in exterior walls, or insulation that on I installation readily conforms to available space shall extend behind 6ping and Wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. When required to be sealed, concealed fire sprinklers shall only be sealed ECon-al'e',,d in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. in aaauion, mspecnon or iog wahs shah be in accordance with the provisions of UU-400. 8/28/2018I10:25 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 1 1 ' • j 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. I 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) i 4.. Number of bedrooms j 5,. Is this a worst case? (yes/no) 6'. Conditioned floor area (sq. ft.) 3. 1 4. 3 13. Cooling system: Capacity 40.0 a) Split system SEER 16.0 5. No b) Single package SEER c) Ground/water source SEER/COP 6. 2228 d) Room unit/PTAC EER e) Other 7� Windows, type and area a) U-factor:(weighted average) 7a. 0.663 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.263 c) Area 7c. 255.7 8i Skylights i a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9�1 Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. c) Concrete, raised (R-value) 9c. I 10. Wall type and insulation: i A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) j B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 111. Ceiling type and insulation level a) Under attic b) Single assembly j c) Knee walls/skylight walls d) Radiant barrier installed 10A1. 10A2. 4.1 14. Heating system: Capacity 27.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.98 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g) Other 110131. 11.0 10B2. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 38.0 b) Cross ventilation No 11 b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has comEpon ith the Florida Building Code, Energy Conservation, through the above energy saving features which will be insor exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed b installed code compliant features. i Builder Signature: W �� Date: Address of New Home: SLASH PINE TRAIL City/FL Zip: FORT PIERCE, FL 34951 I 8/28/2018 10:25:02 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1