HomeMy WebLinkAboutENERGY EFFICIENCY CODEFu i= 4-4:t::7,
FOR405-2017 L Kul ` 81 V -C) el(P
FLORM RIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
RECEIVED
Project Name: REED RESIDENCE
Builde
Name: DAVE GOLDEN HOMES, INC.
�CAN
Street: SLASH PINE TRAIL
Permi
Office: ST LUCIE COUNTY
NCI)
City, State, Zip: FORT PIERCE, FL, 34951
NOV 0 7 2018
Permii
Number:
BY
Owner:
Judsd
lion: ST LUCIE COUNTY
a
�l Lucie County
Desigi Location: FL, Fort Pierce
°IR I,�l! le �1L�Fi l P'p(I't11$ R411
St. Lucie (Florida Climate Zone 2 )
I
1. New construction or existing
New (From Plans)
9. Wall Types(1694.0 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
b. Frame Wood, Adjacent
R=4.1 1446.00 ft2
-
R=11.0 248.00 ft2
3. Number of units, if multiple family
1
c. N/A
R= ft
4. Number of Bedrooms
3
d. N/A
R= ft2
5. Is thi� a worst case?
No
10. Ceiling Types (2228.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=38.0 2228.00 ft2
6. Condiitioned floor area above grade (ftz)
2228
b. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
c. N/Aucts
R _ z
f
11
R ft2
7. Windows(255.7 sqft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: AHU CLST
6 175
a. U-Factor: Sgl, U=0.65
189.00 ft2
SHIGC: SHGC=0.25
b. U-Factor: Sgl, U=0.70
66.67 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
i
a. Central Unit
40.0 SEER:16.00
c. U-Factor: N/A
ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth:
1.333 ft.
Area Weighted Average SHGC:
0.263
14. Hot water systems
I
a. Electric
Cap: 50 gallons
8. Floor Types (2228.0 sqft.)
Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation
R=0.0 2228.00 ft2
b. Conservation features
b. N/A I
R= ft2
None
c. N/A 1
R= ft2
15. Credits
None
Glass/FIor Area: 0.115
Total Proposed Modified Loads: 66.02
PASS
�
Total Baseline Loads: 66.90
1 hereby that the plans and specifications covered by
Review of the plans and
O�T$E
�ertify
this calculation are in compliance with the Florida Energy
specifications covered by this
Code
calculation indicates compliance
with the Florida Energy Code.
rr•l%"
PREPARR.11 Ry.Before
DATE: A
construction is completed
this building will be inspected for
compliance with Section 553.908
a
* m.
I hereby certify that this building,
' compliance
Florida Statutes.
with the Florida Energy Code.
7gnis
COD WE
OWNER%AGENT•
BUILDING OFFICIAL:
DATE: 2y
I
y
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Complia'nce requires an' Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope I leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
i
I
I
8128/20181I10:24 AM
I
I
i
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 1 of 6
i
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: !
REED RESIDENCE
Bedrooms: 3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2228
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
DAVE GOLDEN HOMES,
IN
Rotate Angle: 0
Street:
SLASH PINE TRAIL
Permili Office:
ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State,
Zip:
FORT PIERCE,
FamilyI Type:
Single-family
FL, 34951
New/sting:
Exillent:
New (From Plans)
Comm
I
�
I
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
V I Design
r
Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
1
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
i
BLOCKS
Number
Name
Area
Volume
1
Entire House
2228
18510
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
i
1 I
MASTER BEDROO
343
3430 No
0
1
1
Yes
Yes
Yes
I
2
M CLST 2
21
168 No
0
1
No
Yes
Yes
3 I
M CLST 1
28
224 No
0
1
Yes
Yes
Yes
4
I
M BATH
156
1248 No
0
1
Yes
Yes
Yes
5 I
M TOILET
18
144 No
0
1
No
Yes
Yes
6
UTILITY ROOM
60
480 No
0
1
No
Yes
Yes
7
AHU CLST
12
96 No
0
1
No
Yes
Yes
8
HALLWAY
69
552 No
0
1
No
Yes
Yes
9 I
KITCHEN
309
2472 Yes
0
1
Yes
Yes
Yes
10 i
FAMILY ROOM
312
2496 No
0
1
Yes
Yes
Yes
11
DINING
228
1824 No
0
1
Yes
Yes
Yes
12
I
FOYER
114
912 No
0
1
Yes
Yes
Yes
13
BEDROOM 2
181
1448 No
0
1
1
Yes
Yes
Yes
14 I
CLST 2
18
144 No
0
1
Yes
Yes
Yes
15
BATH 2
99
792 No
0
1
Yes
Yes
Yes
16
CLST 3
18
144 No
0
1
Yes
Yes
Yes
17
BEDROOM 3
182
1456 No
0
1
1
Yes
Yes
Yes
18 �1
HALL
60
480 No
0
1
No
Yes
Yes
I
I
8/28/2018110:24 AM
I
I
I
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 2 of 6
FORM IR405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
I # Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulatio
MASTER BEDRO 39 ft
0
343 ft2
—
1
0
0
I
2 Slab -On -Grade Edge Insulatio
M CLST 2
1 ft
0
21 ft2
e
1
0
0
I
3 Slab -On -Grade Edge Insulatio
M CLST 1
7 ft
0
28 ft2
e
1
0
0
4 Slab -On -Grade Edge Insulatio
M BATH
12 ft
0
156 ft2
e
1
0
0
I
5 Slab -On -Grade Edge Insulatio
M TOILET
1 ft
0
18 ft2
—
1
0
0
I
6 Slab -On -Grade Edge Insulatio
UTILITY ROOM
1 ft
0
60 ft2
e
1
0
0
I
7SIab-On-Grade Edge Insulatio
AHU CLST
1 ft
0
12 ft2
e
1
0
0
8Slab-On-Grade Edge Insulatio
HALLWAY
1ft
0
69ft2
e
1
0
0
I
9Slab-On-Grade Edge Insulatio
KITCHEN
13 ft
0
309 ft2
e
1
0
0
i
I 10SIab-On-Grade Edge Insulatio
FAMILY ROOM
13 ft
0
312 ft2
—
1
0
0
I
11Slab-On-Grade Edge Insulatio
I
DINING
12 ft
0
228 ft2
e
1
0
0
12SIab-On-Grade Edge Insulatio
I
FOYER
6 ft
0
114 ft2
e
1
0
0
13SIab-On-Grade Edge Insulatio
i
BEDROOM 2
27 ft
0
181 ft2
e
1
0
0
I 14SIab-On-Grade Edge Insulatio
I
CLST 2
2 ft
0
18 ft2
—
1
0
0
15SIab-On-Grade Edge Insulatio
I
BATH 2
11 ft
0
99 ft2
—
1
0
0
16SIab-On-Grade Edge Insulatio
I
CLST 3
2 ft
0
18 ft2
—
1
0
0
17SIab-On-Grade Edge Insulatio
I
BEDROOM 3
27 ft
0
182 ft2
_
1
0
0
18SIab-On-Grade Edge Insulatio
I
HALL
1 ft
0
60 ft2
—
1
0
0
I
i
ROOF
Roof
Gable
Roof
Solar
SA Emitt
Emitt
Deck
Pitch
# Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
I
1 Hip Composition shingles 2413 ft2
0 ft2
Medium
0.6
No 0.9
No
0
22.6
ATTIC
,/ II
V I # Type
Ventilation
Vent Ratio (1
in)
Area
RBS IRCC
1 Full attic
Vented
150
2228 ft2
N N
8/28/2018110:24 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6
I
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
I
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) MASTER BEDRO
38
Blown
343 ft2
0.1
Wood
I
2
Under Attic (Vented) M CLST 2
38
Blown
21 ft2
0.1
Wood
3
Under Attic (Vented) M CLST 1
38
Blown
28 ft2
0.1
Wood
i
4
Under Attic (Vented) M BATH
38
Blown
156 ft2
0.1
Wood
5
Under Attic (Vented) M TOILET
38
Blown
18 ft2
0.1
Wood
i
I
6
Under Attic (Vented) UTILITY ROOM
38
Blown
60 ftz
0.1
Wood
I
7
Under Attic (Vented) AHU CLST
38
Blown
12 ftZ
0.1
Wood
8
Under Attic (Vented) HALLWAY
38
Blown
69 ftZ
0.1
Wood
9
Under Attic (Vented) KITCHEN
38
Blown
309 ft2
0.1
Wood
10
Under Attic (Vented) FAMILY ROOM
38
Blown
312 ft2
0.1
Wood
11
Under Attic (Vented) DINING
38
Blown
228 ft2
0.1
Wood
12
Under Attic (Vented) FOYER
38
Blown
114 ft2
0.1
Wood
13
Under Attic (Vented) BEDROOM 2
38
Blown
181 ft2
0.1
Wood
1 14
Under Attic (Vented) CLST 2
38
Blown
18 ft2
0.1
Wood
I
15
Under Attic (Vented) BATH 2
38
Blown
99 ft2
0.1
Wood
1 16
Under Attic (Vented) CLST 3
38
Blown
18 ft2
0.1
Wood
17
I
Under Attic (Vented) BEDROOM 3
38
Blown
182 ft2
0.1
Wood
18
Under Attic (Vented) HALL
38
Blown
60 ft2
0.1
Wood
WALLS
1
Adjacent
viCaty
Width
Height
Sheathing Framing
Solar
Below
SpaceArpn
le
Et
Frnr-finn,
1
N
Exterior Concrete Block - Ext InsMINSTER BE
4.1
3
0 10
0
30.0 ft2
0
0
0.6
0
2
S
Exterior Concrete Block - Ext InsMASTER BE
4.1
21
0 10
0
210.0 ft2
0
0
0.6
0
3
W
Exterior Concrete Block - Ext InsMASTER BE
4.1
15
0 10
0
150.0 ft2
0
0
0.6
0
4
S
Exterior Concrete Block - Ext Insu#A CLST 1
4.1
7
0 8
0
56.0 ft2
0
0
0.6
0
5
S
Exterior Concrete Block - Ext InsulM BATH
4.1
12
0 8
0
96.0 ft2
0
0
0.6
0
6
i W
Exterior Concrete Block - Ext InsuKITCHEN
4.1
13
0 8
0
104.0 ft2
0
0
0.6
0
7
W
Exterior Concrete Block - Ext InCAMILY ROO
4.1
13
0 8
0
104.0 ft2
0
0
0.6
0
8
E
Exterior Concrete Block - Ext Insul DINING
4.1
12
0 8
0
96.0 ft2
0
0
0.6
0
9
E
Exterior Concrete Block - Ext Insul FOYER
4.1
6
0 8
0
48.0 ft2
0
0
0.6
0
10
N
Exterior Concrete Block - Ext InfiffDROOM 2
4.1
14
0 8
0
112.0 ft2
0
0
0.6
0
11
I E
Exterior Concrete Block - Ext InfiffDROOM 2
4.1
13
0 8
0
104.0 ft2
0
0
0.6
0
_ 12
II N
Exterior Concrete Block - Ext Insul CLST 2
4.1
2
0 8
0
16.0 ft2
0
0
0.6
0
13
I N
Exterior Concrete Block - Ext Insul BATH 2
4.1
11
0 8
0
88.0 ft2
0
0
0.6
0
14
N
Exterior Concrete Block - Ext Insul CLST 3
4.1
2
0 8
0
16.0 ft2
0
0
0.6
0
15
i N
Exterior Concrete Block - Ext InfiffDROOM 3
4.1
14
0 8
0
112.0 ft2
0
0
0.6
0
_ 16
W
Exterior Concrete Block - Ext InfiffDROOM 3
4.1
13
0 8
0
104.0 ft2
0
0
0.6
0
17
E
Garage Frame - Wood UTILITY RO
11
23
8
184.0 ft2
0
0.25
0.600000
0
18
I S
Garage Frame - Wood DINING
11
8
8
64.0 ft2
0
0.25
0.600000
0
I
I
I
8/28/2018 10:24 AM
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 4 of 6
• I
FORM IR405-2017 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
I
Wall
Overhang
#
Omt ID Frame
Panes
NFRC
U-Factor SHGC Imp
Area Depth
Separation
Int Shade
Screening
1
W 3 Metal
Low-E Single
Yes
0.65 0.25 N
30.0 ft2 1 ft 4 in
1 ft 4 in
None
None
2
S 5 Metal
Low-E Single
Yes
0.65 0.25 N
12.0 ft' 1 ft 4 in
1 ft 4 in
None
None
I
1 3
W 6 Metal
Low-E Single
Yes
0.65 0.25 N
30.0 ft2 1 ft 4 in
1 ft4 in
None
None
4
W 6 Metal
Low-E Single
Yes
0.7 0.3 N
20.0 ft2 1 ft 4 in
1 ft 4 in
None
None
1 5
I
W 7 Metal
Low-E Single
Yes
0.65 0.25 N
30.0 ft2 1 ft 4 in
1 ft 4 in
None
None
6
W 7 Metal
Low-E Single
Yes
0.7 0.3 N
20.0 ft2 1 ft 4 in
1 ft 4 in
None
None
1 7
E 8 Metal
Low-E Single
Yes
0.65 0.25 N
30.0 ft2 1 ft 4 in
1 ft 4 in
None
None
8
E 9 Metal
Low-E Single
Yes
0.7 0.3 N
6.7 ft2 1 ft 4 in
1 ft 4 in
None
None
9
E 9 Metal
Low-E Single
Yes
0.7 0.3 N
20.0 ft2 1 ft 4 in
1 ft4 in
None
None
10
E 11 Metal
Low-E Single
Yes
0.65 0.25 N
30.0 ft2 1 ft 4 in
1 ft 4 in
None
None
11
N 13 Metal
Low-E Single
Yes
0.65 0.25 N
12.0 ft2 1 ft 4 in
1 ft 4 in
None
None
12
W 16 Metal
Low-E Single
Yes
0.65 0.25 N
15.0 ft2 1 ft 4 in
1 ft 4 in
None
None
j
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
I
506 ft2
506 ft2
2B ft
8 ft
11
I
INFILTRATION
I
# Sicope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Who
ilehouse Proposed ACH(50)
.00037
2159.5 118.55 222.96 .2708
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COPI
27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow
SHR Block
Ducts
i
1
Central Unit/
Split
SEER: 16
40 kBtu/hr 1200 cfm
0.8 1
sys#1
I
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap
Use SetPnt
Conservation
1
Electric
None
Garage
0.98 50 gal 62.3 gal 120 deg
None
I
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector
Model #
Area
Volume FEF
None None
ft2
I
I
I
I
I
I
I
I
8/28/2018 j10:24 AM
I
I
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 5 of 6
FORM IR405-2017 INPUT SUMMARY CHECKLIST REPORT
DUCTS
— Supply
—
—
Return —
Air
CFM 25
CFM25
HVAC #
# Location R-Value
Area
Location
Area
Leakage
Type
Handler
TOT
OUT QN RLF
Heat Cool
f 1 Attic 6
175 ft2
Attic
18 ft2
Default Leakage
AHU CLST
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Coolin Jan Feb
Heating Jan Feb
Mar
Mar
A r
f Apr
f
Me
M y
Jun
f Jun
Jul
f Jul
Au
Aug
n Se
Sep[]Oct
[ ]Oct
Nov
Nov
Dec
Dec
Ventin Jan Feb
Mar
[X] A r
[
Ma
[ Jun
[ Jul
Au
Se
[X] Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling I(WD) AM
78
78
78
78
78
78
78
78
80 80
80
80
1 PM
80
80
80
80
78
78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78
78
78
78
80 80
80
80
i PM
80
80
80
80
78
78
78
78
78 78
78
78
Heating (WD) AM
65
65
65
65
65
65
65
68 -
68 68
68
68
i PM
68
68
68
68
68
68
68
68
68 68
68
68
Heating (WEH) AM
65
65
65
65
65
65
65
68
68 68
68
68
1 PM
68
68
68
68
68
68
68
68
68 68
68
68
I
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
`
M CLST 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
= 0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
UTILITY ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
AHU CLST
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FAMILY ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
D'fault(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
D {fault(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 Ibs/s .ft.
ft2
ft
0.3
HALL
I Name:
I
Rating Compant:
I
I
I
I
i
i
8/28/2018 0:24 AM
I
EnergyGauge® USA Section R405.4.1 Compliant Software
i
Page 6 of 6
i
20117 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
i
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: REED RESIDENCE Builder Name: DAVE GOLDEN HOMES, INC.
Street: SLASH PINE TRAIL Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, 34951 Permit Number:
Y
U
Olwner: Jurisdiction: ST LUCIE COUNTY
=
Design Location: FL, Fort Pierce
U
I
COIMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
i
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
I
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
I
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls)
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the .cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows,
skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
i
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors I
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space
walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
I
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts,
penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrowlcavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage
separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed
lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
Ibe
sealed to the drywall.
thermal envelope shall be air tight and IC rated.
PlumbinIg and wiring
Batt insulation shall be cut neatly to fit around wiring a
I
plumbing in exterior walls, or insulation that on
I
installation readily conforms to available space shall
extend behind 6ping and Wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register
boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
When required to be sealed, concealed fire sprinklers shall only be sealed
ECon-al'e',,d
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. in aaauion, mspecnon or iog wahs shah be in accordance with the provisions of UU-400.
8/28/2018I10:25 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
1 1 ' • j
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
I
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
i
4.. Number of bedrooms
j
5,. Is this a worst case? (yes/no)
6'. Conditioned floor area (sq. ft.)
3. 1
4. 3 13. Cooling system:
Capacity 40.0
a) Split system
SEER 16.0
5. No b) Single package
SEER
c) Ground/water source SEER/COP
6. 2228 d) Room unit/PTAC
EER
e) Other
7� Windows, type and area
a) U-factor:(weighted average) 7a. 0.663
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.263
c) Area 7c. 255.7
8i Skylights
i a) U-factor:(weighted average)
8a. NA
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
9�1 Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
c) Concrete, raised (R-value)
9c.
I
10. Wall type and insulation:
i A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
j B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
111. Ceiling type and insulation level
a) Under attic
b) Single assembly
j c) Knee walls/skylight walls
d) Radiant barrier installed
10A1.
10A2. 4.1
14. Heating system: Capacity 27.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.98
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%
g) Other
110131. 11.0
10B2.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a. 38.0
b) Cross ventilation No
11 b.
c) Whole house fan No
11c.
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has comEpon
ith the Florida Building Code, Energy Conservation, through the above energy
saving features which will be insor exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed b installed code compliant features. i
Builder Signature: W �� Date:
Address of New Home: SLASH PINE TRAIL City/FL Zip: FORT PIERCE, FL 34951
I
8/28/2018 10:25:02 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1