Manufacturer: MI Windows and Doors, LLC
650. West Market St fDGratz, Pennsylvania 17030v I�
Product Line:. 5764 - Vertical Mullion SC NED
BY
Compliance: St LUde (;Ounty
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of �y
Business and Professional Regulation for Statewide Acceptance per Rule 61G20-3.005 method 1(d). The product
listed herein complies with requirements of the current Florida Building Code.
Supporting Technical Documentation:
1. Approval document: drawing number 08-01439 Revision B, prepared, signed and sealed'by Luis Roberto
Lomas P.E
2. Mullion analysis report No. 512063-1A and -2A per AAMA 450-10 Option 3, prepared, signed and sealed, by
Luis Roberto Lomas P.E.
Limitations and Conditions of use:
• Maximum design pressure: refer to design pressure charts in approval document.
• Maximum single window unit size: 52 1/8" x 84"
• Window units attached to mullion must have their own separate approval..
• This product is not rated to be used in the HVHZ.
• This product is impact resistant and does not require impact protection in Wind -Borne Debris Regions, up to
Wind Zone 3.
• Design pressure of mulled units shall be controlled by the lesser design pressure of the assembly
components; mullion or individual units.
• All windows attached to mullion must be manufactured by MI Windows and Doors, Inc.
Installation:
Mullion must be installed in strict accordance with manufacturer's instructions and approval document 08-01439
Revision B.
Certification of Independence:
Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the
product(s) for which this report is.being issued. Also, I don't have nor will acquire a financial interest in any other
entity involved in the approval process of the listed product(s).
1 of 1
�N`J�S.• . • • :�9%�.
�.*. 0 51
VT
�.
y10 , TAT:E OF w
ORVOt
ssYONAL����`.
!II(L11
Luis R. Lomas, P.E.
FL No.: 62514
10/18/2017
iI T I Ll ECO. LNC.
TILLIT TESTING & ENGINEERING COMPANY
A. 11LL11,, JK., Y.C.
REPORT NO.:
PRODUCT EVALUATION - REPORT
tilteco@ao4:com
R. P.E. License No. 44167
FL E.B. License No. 00067.19
17-0725.03 --
DATE: July 25, 2017
l�
PRODUCT CATEGORY: Hurricane Shutters
-fcp— A, f
PRODUCT SUB -CATEGORY: Storm .Panel
PRODUCT NAME: 24 Gage Bertha Galvanized Steel Storm Panel
SUBMITTED BY: Eastern Metal Supply Inc
4268 Westroads Drive
West Palm .Beach, Florida 33407
1. PURPOSE OF EVALUATION:
This.is a Product Evaluation Report issued by Walter A. Tillit, Jr,, P.E. (System
ID # 1906) to the Eastern Metal Supply Inc.,, Rule Chapter No. 61G20-3,
Method 1D of. the -Florida Department of Business and Professional
Regulation:
This product is being issued an Evaluation Report .as described herein, and has
been verified for compliance in accordance with'. 2017 Sixth Edition of the
Florida Building Code, and to verify that the. product is for the purpose intended
at least equivalent to that required by the Code.
This Product Evaluation Report shall be subject to review and revision in case of
a Building Code change that may all
its limitations and conditions.
2. EVIDENCE SUBMITTED:
2.1. PRODUCT EVALUATION DOCUMENT (P E D )•
Drawing No. 17-089 (Revises Drawing # 15-041), titled
Galvanized Steel Storm panel (2" Deep)", sheets 1 thru 10
Tilteco, Inc.; signed and sealed by Walter A.Tillit, Jr., P�
This drawing is an integral part of this Evaluation Report. ,%ai
N.W. 36th Street, Suite 305, Miami, Florida 33166 - Phone: (305)
"24 Gage Bertha
4531
PRODUCT EVALUATION REPORT NO. 17-0725.03
2.2. TEST REPORTS:
Large missile impact and cyclic load test were performed. under ASTM E-1886,
E4996 standard as per section 1609.1.2 of the Florida building Code. Uniform
Static Load Tests as per Section 17.09.5.2, ASTM E-330. Test reports prepared
'by American Testing Lab of South Florida, Report No. 0304:01-08, dated May
12, 20.0.8, and signed and sealed by William R. Mehner, P.E. and Henry Hattem
P.E., Report No 1220.01-5, dated July 16, 2007, signed and sealed by William R.
Mehner, P.E., and Henry Hattem, P.E., Report No 0926.01-03, dated January 15.,
2004, signed and sealed by William R. Mehner, P.E. and Henry Hattem, P.E.
Tensile test reports # 8CM-256, by QC Metallurgical Inc. Laboratory, dated
March 21, 2008 signed and sealed by Frank. E. Grate, Jr. P.E., as per ASTM E: 8.
2.3. STRUCTURAL ENGINEERING CALCULATIONS:
This revision includes new calculations to verify the ' moment of inertia of storm
panel where its end lips include now hemmed edges. Comparison is made in
relation to panel with non -hemmed "edges.
On 24 Gage Bertha Galvanized Steel Storm Panel (2" Deep) for maximum
panel length vs. design wind load, as well as maximum anchor spacing vs.
design wind load and panel. length based on rational and. comparative analysis,
and in accordance with sections 1604 of the Florida Building Code. Calculations
prepared by Tilteco, Inc., dated May 12, 2008, signed and sealed by Walter A.
Tillit, Jr., P.E.
3. MISSILE IMPACT RESISTANCE:
Based on new calculations explained on item 2:3 above, we have concluded that
storm panels with hemmed edges .comply also with large missile impact under
section 1609.1.2 of the Florida Building Code, as per ASTM. E-1886, E- 996
Standard.. Large missile impact under section 1609.1.2 of the Florida Building
Code, as per ASTM E-1886, E-1996 Standards, with missile level "D" (basic
protection).
4. WIND LOADS RESISTANCE.
24 Gage Bertha Galvanized Steel Storm Panel (2" Deep) has been verified to
sustain wind pressures. Maximum panel length shall be as indicated on sheet 2
of 10 of Product Evaluation Document (P.E.D.), Drawing # 17-089. Maximum
Anchor Spacing shall be as indicated on sheets 6, 7 and 10 of®,%%.Product
Evaluation Document (P.E.D.), Drawing No. 17-089. ,ao' %���Xtha
Galvanized Steel Storm Panel (2" Deep) has been verifie¢ma°f �`Yode.C_0Z! ptra ce
to work as a non -porous storm shutter assembly, as per
rti
a NO.44167
E +
O 4 M
���L•�Qba�o
11 PRODUCT EVALUATION REPORT NO. 17-0725.03
.5. INSTALLATION:
Installation shall be performed strictly in accordance with the details indicated on
sheets 4 thru 6 and 8 and 9 of 10 of Product Evaluation Document (P.E.D.),
drawing No. 17-089. Minimum separation to glass shall be as indicated on
sheets 4 thru 6, 8 and 9 of 10. of Product Evaluation Document (P.E:D,), drawing
17-089.
Shall be strictly in accordance with General Notes and Components indicated on
sheets 11. 2 and 3 of 10, of Product Evaluation Document (P.E.D.), drawing No.
17=089.
Anchor specifications shall be as indicated on sheets 1, 5, 6, 8 .and 9 of 10 of
Product Evaluation Document (P.E.D.), drawing No..17-089.
7. LIMITATIONS AND CONDITIONS OF USE:
7:1. Shall be strictly in compliance with General.' Notes No.. 1 and 7 thru 12,
indicated 'on sheet 1 of 10, of Product Evaluation Document (P.E.D.), drawing
No. 17-089 prepared by Tilteco, Inc. and signed and sealed by Walter A. Tillit,
Jr.,. P.E.
i
7.2. Product shall not be installed within HIGH VELOCITY HURRICANE ZONES
as defined on section 1620.2 of the Florida Building Code..
7.3. Product shall only be installed into poured concrete, concrete block and
wood frame structures.
Product Evaluation Report prepared by Walter A., THIN, Jr.,. P.E. (Florida
License No. 44167), President of Tilteco, Inc. (Florida EB-0006719)..