Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutTRUSS PAPEREWORK114
Lumber design values are in accordance with ANSI/TPI 1 section 6.3
RERs L gns rely on lumber values established by others.
q ( � OCT 112018 � FILE COPY
MiTek USA, Inc.
6904 Parke East Blvd.
Site Information: Tampa, FL 33610-4115
Customer Info: Dave Golden Homes Project Name: Reed Res. Model:
Lot/Block: Subdivision: t� ( 16 f l 0
Address Slash Pine Trail
City: Ft. Pierce State: FL I L VIKLX
NamelAddress and License # of Structural Engineer of Record, If there is one, for the building.
Name License #:
Address:
City: State:
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TPI2014 Design Program: MiTek 20/20 8.2
Wind�Code: ASCE 7-10 [All Heigh][I Wind Speed: 170 mph
Roof Load: 37.0 psf Floor Load: N/A psf
This package includes 52 individual, Truss Design. Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
cnnfnrmS to 81 G15-31.003. section 5 of the Florida Board of Professional Engineers Rules.
No.
�Seal#
Truss Name
Date
No.
Seal#
Tru�NameDate
1
IT14564047
A01
7/13/18
18
T14564064
A187/13/18
12
48IA02
I7/13/18
119
IT14564065IA19G
17/13/18
I
13 1IT14564049
I
A03 17/13/18
120
I
T14564066 I
A20 17/13/18
I
14 PT14564050IA04
17/13118
121
IT14564067IA21
I7/13/18
I
15
IT14564051 IA05
17/13/18
122
IT14564068IA22G
17/13/18
I
16 I
T14564052
I A06
17/13/18
123
I T14564069
I B01
17/13/18 I
17 I
T14564053
I A07 17/13/18
124 I
T14564070
I B02
17/13/18 I
18 I
T14564054
I A08
17/13/18
125
I T14564071
I B03
17/13/18 I
19
IT14564055
IA09
17/13/18
126
1T14564072
B04
17/13/18 I
110
I T14564056
I A10
17/13/18
127
I T14564073
I B05G
17/13/18 I
11
I T14564057
I A11
17/13/18
128
I T14564074
I C01
17/13/18 I
112
I T14564058
I Al2
17/13/18
129
I T14564075
I CO2
17/13/18 I
113
I T14564059
I A13
17/13/18
I30
I T14564076
I MV2
17/13/18 1
114
I T14564060
I A14
17/13/18
131
I T14564077
I MV4
17/13/18 I
115
IT14564061
IA15G
17/13/18
132
1T145640781MV6
17/13/18 I
116 iI
T14564062
I A16
17/13/18
133
I T14564079
I MV7
17/13/18 I
117 II
T14564063
I A17
17/13/18
134
I T14564080
I MV8
17/13/18 1
The truss drawing(s) referenced above have been prepared by MiTek
USA, Inc. under my direct supervision based on the parameters
provided by East Coast Truss.
TrussiDesign Engineer's Name: Albani, Thomas
My license renewal date for the state of Florida is February 28, 2019.
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the "engineer named is licensed in the jurisdiction(s) identified and that the
designslcomply with ANSlfrPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to'' MiTek. \ Any project specific information included is for MiTek's customers
file reference purpose only, and was not taken into account in the preparation of
these designs. MiTek has not independently verified the applicability of the design
parameters or the designs for any particular building. Before use, the building designer
should verify applicability of design parameters and property incorporate these designs
into the loverall building design per ANSUTPi 1, Chapter 2.
A.
CEN;S
No 3.9.38
ik
00V. 4�.N
:cc
Thomas A. Albanl PE NOW,
Oc,,U A, ln'ai FL"OA06d
6904: Par)(6. East BIVd. lam jkt FL 33610
Date:.
July 13,2018
Albani, Thomas 1 of 2
J36445 - J36445-Dave Golden Homes -Reed Res.
Site Information:
Customer Info: Dave Golden Homes Project Name: Reed Res. Model:
L6t/Block: Subdivision:
Address: Slash Pine Trail
City: Ft. Pierce State: FL
No.
eal#
FT14564081
Truss Name
Date
35
IMV10
7/13/18
I36
IT14564082
I MV10A
17/13/18
13i7
IT14564083
I MV12
17/13/18 I
138
IT14564084
I MV14
17/13/18 I
13'9
IT14564085
I MV16
17/13/18 I
140
I T14564086
I ZCJ 1
17/13/18 I
141
IT14564087
I ZCJ1A
I7/13/18 I
142
IT14564088
I ZCJ3
17/13/18 I
143
IT14564089
I ZCJ3A
17/13/18
144
IT14564090
I ZCJ5
17/13/18
145
IT14564091
I ZCJ5A
17/13/18 I
I4,6
IT14564092
I ZEJ6G
17/13/18 I
141
IT14564093
I ZEJ7
17/13/18 I
148
IT14564094 I
ZERA
I7/13/18 I
149 IT14564095
I
ZERT 17/13/18
I
15;0 I
T14564096 I
ZHJ7 17/13/18
1511 IT14564097IZHJ7A
17/13/18
I
152 IT14564098IZHJ7B
17/13/18
I
2 of 2
Job s
Truss
Truss Type
Qty
Ply
Golden Homes -Reed Res.
�J36445-Dave
T14564049
J36445
I
A03
Hip
1
1
Job Reference o tional
East Coast Truss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:20 2018 Page 1
I D:YE5jAwrU u64TB gd P Dzn GdgyyX Wd-n8OwlMXB C ga6 H I H Qf T_S4sJJtF ROXI C F6f5wMOyyU_T
7-5-7 13-11-1 21-0-0 24-10-0 32-5-3 40-0-6 45-10-0 7-0-
7-5-7 6-5-10 7-0-15 3-10-0 7-7-3 7-7-3 5-9-10 2-8
Scale = 1:80.5
5x5 =
5x8 =
5.00 12
1 6x6 _ 4x6 =
4x8 =
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/deft L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.86
Vert(LL)
0.57 17-18 >840 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.79
Vert(CT)
-0.74 17-18 >648 180
M18SHS
244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.75
Horz(CT)
0.34 12 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -AS
Weight: 232 lb
FT = 0%
LUMBER- I
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2 `Except*
BOT CHORD
Rigid ceiling directly applied.
.1-17,12-14: 2x4 SP No.1
WEBS
1 Row at midpt 4-16, 9-13
WEBS 2x4 SP No.3 `Except`
9-13: 2x4 SP No.2, 9-12: 2x6 SP No.2
REACTIONS. (Ib/size) 12=2652/0-7-10, 1=1359/0-7-10, 10=-554/0-3-0
Max Horz 1=401(LC 6)
Max Uplift 12=-1604(LC 8), 1=-853(LC 8), 10=-652(LC 13)
Max Grav 12=2652(LC 1), 1=1359(LC 1), 10=240(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-4550/2743, 2-4=-3682/2255, 4-5=-2644/1628, 5-6=2278/1530, 6-7=-2020/1298,
1 7-9=-1460/937,9-10=-1120/2036
BOT CHOfjD 1-18=-2406/4481, 17-18=-2407/4487, 16-17=-1784/9594, 15-16=-705/1810,
13-15=-583/1302, 12-13=-2059/1293, 10-12=-1808/1133
WEBS 2-17=873/616, 4-17=-158/456, 4-16=-1187/817, 5-16=363/722, 6-16=-411/988,
6-15=-260/171,7-15=-180/746,7-13=-853/622,9-13=-1858/3321,9-12=2164/1415
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) Plates checked for a plus or minus 0 degree rotation about its center.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
8) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
12=1604', 1=853, 10=652.
10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
A.
No 39380
i-33
'/,OR
,IO N A �1����`.
11111
Thomas A. Albani PE No.39380
MIek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
II II\r 13 gf11 R
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111II.7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must vedfy the applicability of design parameters and properly incorporate this design into the overall HppV I
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing �y� iTek-
is always required for stability and to prevent collapse with possible personal Injury,and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
* rl
D
Job y
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564048
J36445
A02
Roof Special
3
1
Job Reference o tional
Last coast Tuss, I-.t. merce, t-L 04`J40
48
B-1-1 7-4-15
8-1-1
-"'- z.uu 11z
ts.zzu s may z4 zuiu mi I ex mausines, Inc. hr1 JUI 13 1z:=iu zults rage 1
7-4-15 5-8-7 5-8-7 5-8-7 5-9-10
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
, Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.85
Vert(LL)
0.56 17-19
>861
240
TCDL 1 7.0
Lumber DOL
1.25
BC 0.94
Vert(CT)
-0.77 17-19
>626
180
BCLL - 0.0
Rep Stress Incr
YES
WB 0.73
Horz(CT)
0.33 12
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -AS
12
4x6 =
6x6 =
45.8-8 45-
PLATES GRIP
MT20 244/190
M18SHS 244/190
Weight: 231 lb FT = 0%
LUMBER-1
BRACING -
TOP CHORD
2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD
2x4 SP No.2 *Except*
BOT CHORD
Rigid ceiling directly applied.
1-18,12-15: 2x4 SP No.1
WEBS
1 Row at midpt 2-17, 6-16, 9-13
WEBS
2x4 SP No.3 `Except`
9-13: 2x4 SP No.2, 9-12: 2x6 SP No.2
REACTIONS.
(lb/size) 12=2816/0-7-10, 1=1338/0-7-10, 10=-698/0-3-0
Max Horz 1=-436(LC 6)
Max Uplift 12=-1823(LC 8), 1=-841(LC 8), 10=-908(LC 13)
Max Grav 12=2816(LC 1), 1=1344(LC 13), 10=195(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-4515/2676, 2-4=-3380/2059, 4-5=-2538/1590, 5-6=-1925/1264, 6-7=-1744/1148
7-9=-892/544, 9-10=-1317/2469
BOT CHORD 1-19=-2338/4476, 17-19=-2339/4477, 16-17=-1573/3365, 14-16=-656/1590,
13-14=-232/730, 12-13=-2436/1481, 10-12=-2200/1312
WEBS 2-19=0/295, 2-17=1101/759, 4-17=-189/448, 4-16=1066/757, 5-16=-824/1459,
6-16=327/457, 6-14=-458/325, 7-14=-469/1134, 7-13=-1141/735, 9-13=-1726/3117,
9-12=-2269/1464
`,,111111111111',
NOTES-
P S A. �
�� q
1) Unbalanced live loads have been for this design.
�` • G E N • • •.'9 '�
roof considered
��
S� •'. v� ���
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; 6=54ft; L=46ft; eave=6ft; Cat.�•�'\
11; Exp Cj Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ;end vertical left and right exposed; porch right
N O 39380
exposed Lumber DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
: F : �
�� -
will fit be}ween the bottom chord and any other members, with BCDL = 10.Opsf.
7) Bearing 1
�� "� �• Q:•�
at joint(s) considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
of
��
41 R ` �
capacity bearing surface,
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Gt=lb)
AL `�
12=1823;1=841,10=908.
���I11111111��`
9) This truss design requires that a minimum of 7116" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
Thomas A. Albani PE No.39380
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek'
is always �equired for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 36610
JUIy 13,zu it
Job s
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564047
J36445
A01
Roof Special
1
1
Job Reference (optional)
East Coast Truss, Ft. Pierce, FL 34946
8-1-1 7-4-15
48
5.00 12
8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:18 2018 Page 1
I D:YE5jAwrUu64TBgdPDznGdgyyXWd-rmHAKgWNhDK02?72X3y_?REzUSkF30lyfLcgH7yyU_V
7-4-15 5-8-7 5-8-7 5-8-7 5-9-10
,.uu 114 -_.- 11
6x6 =
Scale = 1:77A
4x6 =
8-1-1 15-6-1 20�-0
28-7-7
34-3-15 40-0-6
40 -3
45.8-8 45- -0
8-1-1 7-4-15 4-9-15
8-3-7
5-8-7 5-6-7
0 - 3
5-4.5 0- -8
Plate Offsets (X,Y)— f1:0-0-10.Edoel
I
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/deft Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.86
Vert(LL)
0.57 16-18 >849 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.94
Vert(CT) -0.77 16-18 >626 180
M18SHS
244/190
BCLL .0.0 `
Rep Stress Incr YES
WB 0.75
Horz(CT)
0.33 11 n/a n/a
BCDL 10.0
Code FBC2017rrPI2014
Matrix -AS
Weight: 229 lb FT = 0%
LUMBER- I
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2 *Except*
BOT CHORD
Rigid ceiling directly applied.
1-17,11-14: 2x4 SP No.1
WEBS
1 Row at midpt 2-16, 6-15,
9-12
WEBS 2x4 SP No.3 *Except*
9-12: 2x4 SP No.2, 9-11: 2x6 SP No.2
REACTIONS. (lb/size) 11=2823/0-7-10, 1=1338/0-7-10, 10=-770/0-3-0
Max Horz 1=419(LC 7)'
Max Uplift 11=-1861(LC 8), 1=-838(LC 8), 10=-928(LC 13)
Max Grav 11=2823(LC 1), 1=1345(LC 13), 10=331(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-4511/2693, 2-4=-3375/2078, 4-5=2538/1609, 5-6=1925/1277, 6-7=-1743/1148
1 7-9=-890/526, 9-1 0=-1 368/2454
BOT CHORD 1-18=-2401/4459, 16-18=-2402/4460, 15-16=-1637/3348, 13-15=-704/1590,
12-13=-261/732, 11-12=-2433/1481, 10-11=2198/1309
WEBS 2-18=0/295, 2-16=-11011758, 4-16=189/448, 4-15=-10661757, 5-15=837/1456,
6-15=-325/453, 6-13=458/336, 7-13=-489/1130, 7-12=11401749, 9-12=175513112,
9-11=-2272/1493
NOTES-
``t1%t1111111///,'I
q
1) Unbalanced roof live loads have been considered for this design.
%% .
,��` .•.�!✓ E•N S+'•.'92�i�
�' F �'
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; 6=54ft; L=46ft; eave=6ft; Cat.
'•
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch right
No 39380
exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
' -0
i -10
will fit betYveen the bottom chard and any other members, with BCDL = 10.Opsf.
7) Bearing 1
i 0
Q:••
at joint(s) considers parallel to grain value using ANS11TPI 1 angle to grain formula. Building designer should verify
(� .• Q �����
's F;
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joints) except Ut=lb)
.0 `��
�j� S/O �` ,�%
11=1861, 1=838, 10=928.
I���ONA1 1'���
9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
Thomas A. Albanl PE No.39380
Mrrek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
Julv 13 2018
i
® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111.7473 rev. 1010312015 BEFORE USE. ■
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only: Additional temporary and permanent bracing M iTek"
is always rkquired for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the
fabrication,, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPIt Quality Criteria, DSB.89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job 1
Truss
Truss Type
Qty
Ply
Golden Homes -Reed Res.T14564050
L6445-Dave
J36445
A04
Hip
1
1b
Reference o tional
East Coast l russ, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:21 2018 Page 1
3x8
6-9-7 6-1-5 6-1-5 7-10-0 6-8-11 7-0-4
6-9-7 12-10-11 19-0-0
0-0
wnr— i.ru.c
N f�!
N
9
3x6 11
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 10.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TP12014 _
CSI.
TC 0.84
BC 0.85
WB 0.91
Matrix -AS
DEFL. in (loc) I/deft Ud
Vert(LL) 0.67 15-16 >720 240
Vert(CT) -0.85 15-16 >570 180
Horz(CT) 0.44 9 n/a n/a
PLATES
MT20
M18SHS
Weight: 215 lb
GRIP
244/190
2441190
FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2 `Except`
TOP CHORD
Structural wood sheathing directly applied, except end verticals.
5-6: 2x4 SP No.1
BOT CHORD
Rigid ceiling directly applied.
BOT CHORD 2x4 SP No.2 *Except*
WEBS
1 Row at midpt 8-10
1-14,9-11: 2x4 SP No.1
WEBS 2x4 SP No.3 *Except*
8-9: 2x6 SP No.2
REACTIONS. (lb/size) 9=1493/0-6-9, 1=1493/0-7-10
Max Horz 1=427(LC 7)
Max Uplift 9=-932(LC 8), 1=-930(LC 8)
FORCES. �(lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-5067/3113, 2-4=-4354/2692, 4-5=-3413/2131, 5-6=-3212/2078, 6-7=2647/1696,
1 7-8=-2382/1495,8-9=-14381948
BOT CHORD 1-16=-2824/4915, 15-16=-2829/4925, 13-15=-2287/4167, 12-13--1607/3151,
11 -1 2=-1 196/2418, 10-11 =-1 190/2177
WEBS 2-15=-751/538, 4-15=-134/406, 4-13=-10791724, 5-13=-337/620, 5-12=-128/437,
6-12=545/1187, 7-11 =-1 39/412, 7-10=-582/453, 8-1 0=-1 175/2068
I IAI
NOTES-
1) Unbalanced live loads have been for this design.
,,``,`�P S .
��`
roof considered
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
%%
,'%,` '•\G E N S •'•,
II; Exp C;I Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ;end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
NO 39380
4) All plateslare MT20 plates unless otherwise indicated.
5) Plates checked for a plus or minus 0 degree rotation about its center.
6) This truss has been designed for 10.0 bottom live load live loads.
+
a psf chord nonconcurrent with any other
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
i 44,/
will fit between the bottom chord and any other members.
8) Bearing at joint(s) 9, 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
�01'�� Q.•�
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Qt=lb)
f; , ,���
/ • •�\ �%
I'll N A 1- �0
9=932, 1=930.
!/O
10 This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the to chord and 1/2" sum
9 q 9 PP Y P 9YP
sheetrock be applied directly to the bottom chord.
Thomas A. Albans PE No.39380
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473 rev. 1010312015 BEFORE USE. ■!
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not •
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing WOW
always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication( storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job y
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564051
J36445
A05
Hip
1
1
Job Reference (optional)
East Coast Tjuss, Ft. Pierce, FL 34946
6-1-7 5-5-5 5-5-5
3x8
5x8 =
8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:22 2018 Page 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-jXWg92ZRkRggXcRpmulw9HOiy36 ?ClYayalQuyyU R
5-11-0 5-11-0 5-8-11 6-0-3
3x4 = 5x5 =
5 21 6
Scale = 1:68.7
6-1-7 11-6-11
17-0-0 20-0-0
28-10-0 34-6-12
40-6-15
6-1-7 5 5-5
5-55 3-4-0
8 6-0 5-8-11
6-0.3
Plate Offsets (X,Y)- 11:0-0-7,Edgel. 14:0-5-12.0-2-81
i
LOADING (,PST)
SPACING-
2-0-0
CSI.
DEFL.
in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.70
Vert(LL)
0.70 14-16 >691 240
MT20 244/190
TCDL, 7.0
Lumber DOL
1.25
BC 0.89
Vert(CT)
-0.90 14-16 >540 180
M18SHS 244/190
BCLL 0.0
Rep Stress Incr
YES
WB 0.75
Horz(CT)
0.48 9 n/a n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix -AS
Weight: 214 lb FT = 0%
LUMBER- I
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD 2x4 SP No.2 *Except*
BOT CHORD Rigid ceiling directly applied.
1-15,9-12: 2x4 SP No.1
WEBS
1 Row at midpt 5-11
WEBS 2x4 SP No.3 *Except*
8-9: 2x6 SP No.2
REACTIONS. (lb/size) 1=1493/0-7-10, 9=1493/0-6-9
Max Horz 1=390(LC 7)
Max Uplift 1=-930(LC 8), 9=-932(LC 8)
FORCES.
(Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-5055/3121, 2-3=-4512/2803, 3-4=-3691/2308, 4-5=-3902/2458, 5-6=2403/1628,
6-7=-2646/1689, 7-8=-2207/1398, 8-9=-1440/943
BOT CHORD 1-17=-2837/4876, 16-17=-2843/4889, 14-16=-2418/4306, 13-14=-1813/3419,
11-13=-1899/3534, 10-11=-1113/2023
WEBS 2-16=-576/421, 3-16=-107/356, 3-14=-963/646, 4-14=-307/558, 4-13=-399/851,
5-13=-322/870, 5-11=-1491/878, 6-11=362/696, 7-11=207/545, 7-10=-686/490,
8-10=-1131/1958
NOTES.
,`,�t,�PS� A ,q 4 ��
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
��" �`
.'�\Ci E N S ••.; 9,�,���
II; Exp C 1 Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
���,`�`
'• �' F ��
DOL=1.60 plate grip DOL=1.60
3) Provide dequate drainage to prevent water ponding.
NO 39380
4) All plates are MT20 plates unless otherwise indicated.
5) Plates checked for a plus or minus 0 degree rotation about its center.
6) This truss has been designed for 10.0 bottom
+
a psf chord live load nonconcurrent with any other live loads.
7) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
!
: -33 '
•'
will fit between the bottom chord and any other members.
8) Bearing at joint(s) 1, 9 considers parallel to grain value using ANSIrrPI 1 angle to formula. Building designer should
i �:/
grain verify
of
�F 0R1�'�•�%
capacity bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
� \!� �
��j ,S/ • • • • • •�,v ���
��,,,0 N A"i
1=930, 91 932.
10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
Thomas A. Albanl PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
Julv 13.2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111II-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall HV ff
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing ivi iTek'
is always required for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the
fabrication' storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FL 36610
Job i
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564052
J36445
A06
Hip
1
1
Job Reference a tional
casr wart r russ, rr. rrerce, rL J4Uga
5-5-7 10-2-11
5-5-7 4-9-5
5.00 12
2x4
r; \
u 2
I
_ 1
0
3x8
18
3x4
u.zzu s may z4 zulij MI i ex 1naUSlrles, Inc. rn Jul 13 1z:33:z3 zuits rage 1
I D:YE5jAwrUu64TBgdPDznGdgyyXWd-Bj43NOa3VIyg8m07KcY9iUxssTSgkf1 hpcJayKyyU_Q
15-0-0 20-4-0 1: 7-0 30-10-0 35-6-12 401-15
4-9-5 5-4-0 53-0 5-3-0 r 4-8-11 5-0-3
Scale = 1:68.7
5x8 =
2x4 II
3x4 =
5x6 =
4
5
6
22 7
3xq 5-
3x4
3
8
4x8
9
15
17 16
7x8 =
14 13
3x8 M18SHS =
4x6 =
12
3x4 =2.00 12
3x4 =
3x4 =
11 %
4x4 = 10
3x6 11
25-7-0 30-10-0
Plate Vttsets (X.Y)—
11:U-U-/ Edgel 14:0-5-12 0-2-81. 17:0-5-12.0-2-81
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc) I/deft Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.75
Vert(LL)
0.84 15-16 >573 240
MT20
244/190
TCDL 1 7.0
Lumber DOL
1.25
BC 0.85
Vert(CT) -1.05 15.16 >460 180
M18SHS
244/190
BCLL 0.0
10.0
Rep Stress Incr
YES
WB 0.74
Horz(CT)
0.54 10 n/a n/a
BCDL
Code FBC2017/TP12014
Matrix -AS
Weight: 214 lb
; FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied, except end
verticals.
BOT CHORD 2x4 SP No.1
'Except'
BOT CHORD
Rigid ceiling directly applied.
13-15: 2x4 SP No.2
WEBS 2x4 SP No.3 *Except*
9-10: 2x6 SP No.2
REACTIONS. (lb/size) 1=1493/0-7-10, 10=1493/0-6-9
Max Horz 1=353(LC 7)
Max Uplift 1=-930(LC 8), 10=-932(LC 8)
FORCES. ;(lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-5070/3181, 2-3=-4821/2980, 3-4=-3997/2489, 4-5=-5022/3140, 5-6=5022/3140,
6-7=-3639/2350, 7-8=-2562/1653, 8-9=1997/1271, 9-1 0=-1 4481936
BOT CHORD 1-18=-2900/4852, 16-18=-2543/4378, 15-16=-2026/3710, 14-15=-2021/3694,
12-14=-1229/2348,11-12=-1007/1832
WEBS 2-18=-272/304, 3-18=-122/404, 3-16=-754/552, 4-16=-261/542, 4-15=901/1568,
5-15=286/271,6-15=-911/1619, 6-14=-1095/738, 7-14=-972/1659, 7-12=313/207,
8-12=-285/654,8-11=-776/538,9-11=-1061/1833
NOTES.
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C;J Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide dequate drainage to prevent water ponding.
4) All plate are MT20 plates unless otherwise indicated.
5) Plates checked for a plus or minus 0 degree rotation about its center.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
8) Bearing at joint(s) 1, 10 considers parallel to grain value using ANSI/fPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
1=930, 10=932.
10) This truss design requires that a minimum of 7116" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetroi k be applied directly to the bottom chord.
,,`,`` PSIIAII/q��`,,'
% 0••
J��`r •' \G EN
No 39380
Jo
N
111A11
Thomas A. Albanl PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MTeM connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall �•
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the piTe
fabrication storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564053
J36445
A07
Roof Special
1
1
I
Job Reference o tional
tast 4,0ast I fuss, rt. rietce, rL owafro
5 3-11 9-11-10 17-10-8 22-6-8 27-2-8 , 32-3.0 3 12 4 40-10-2 44 8 0
5-3-11 4-7-15 7-11-14 4 3-1� 4-7-14 3-9-14
Scale = 1:81.3
22 - 2.00112 16 15 14 13
3x6 — 5x10 = 2x4 II 3x4 = 5x5 =
9-7-13 9-11,10 17-10-8
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC20171TP12014
CSI.
TC 0.70
BC 0.54
WB 0.71
Matrix -AS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in (loc) I/deft L/d
0.50 22-25 >240 240
0.44 22-25 >273 180
0.12 13 n/a n/a
PLATES GRIP
MT20 2441190
Weight: 287 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied, except end verticals.
BOT CHORD 2x4 SP No.1 'Except`
BOT CHORD
Rigid ceiling directly applied. Except:
10-15: 2x4 SP No.2
10-0-0 oc bracing: 15-17
WEBS 2x4 SP No.3 *Except*
WEBS
1 Row at midpt 4-21, 7-21, 10-18, 11-13
4-22,12-13: 2x6 SP No.2
I
REACTIONS. (Iv/size) 22=2156/0-7-10, 13=1179/0-5-8, 2=42/0-3-0
Max Horz 2=334(LC 7)
Max Uplift 22=-1645(LC 8), 13=-711(LC 8), 2-250(LC 7)
Max Grav 22=2156(LC 1), 13=1218(LC 14), 2=90(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-384/802, 34=685/1077, 4-6=-997/571, 6-7=-847/610, 7-8=-1989/1309,
J 8-9=-1941/1288,9-10=-1501/1020,10-11=-1431/896
BOT CHORD 2-22=-772/115, 21-22=-963/617, 19-21=-836/1546, 18-19=-1158/2092, 17-18=-707/1302,
10-17=-321/275, 13-14=-372/650
WEBS 3-22=-3531459, 4-22=-1800/1182, 4-21 =-1 088/1910, 7-21 =-1 003/658, 7-19=-443/798,
8-19=-535/398, 8-18=-572/397, 9-18=-658/1084, 11-17=-474/917, 11-14=351/250,
11 -1 3=-1 225/698, 14-17=-4101791
`,A1PS1 Al1q� '
e
NOTES- I
1) Unbalanced roof live loads have been considered for this design.
��� O #
•'�\ G E N S �'•, 9/jj �j
,� ,<�
•� �' F i
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
��
II; Exp C;IEncl., GCpj=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left exposed; porch left exposed;
No 39380
Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
'
6) - This truss has been designed for a live load of 20.6psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
i -33 '. 441 Z
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
Q.•
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
j
Q
�j,\ R ,
22=1645 13=711, 2=250.
8) This truss design that 7/16" be directly to the top 1/2"
-C1 •.0 . • `�?
�O
requires a minimum of structural wood sheathing applied chord and gypsum
sheetrock be applied directly to the bottom chord.
��� N
I�fil
l t 111111,
Thomas A. Albanl PE No.39380
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111II.7473 rev. 10/03/2015 BEFORE USE.
Design val!d for use only with MTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek•
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication; storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building. Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qly
Ply
J36445-Dave Golden Homes -Reed Res.
T14564054
J36445
A08
Roof Special
1
1
I
Job Reference (optional)
East Coast Truss, Ft. Pierce, FL 34946
4-7-15
4-11-7 4-11-7
r—
8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:26 2018 Page 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-clmB?PcxogLF?Dka?k5sK7ZRAgVhx?L8VaYFZfyyU_N
8 9.2.8 3 4 - -e 36.2.4 4No
2 8.0
I 4-8-0 -1-8 3-10.0 2-0-4 4.7-14 3-9.14
Scale = 1:82.3
l
or
rn
m
4
M
24 2.00 12 18 17 16 15
3x6 — 5x10 = 2x4 II 3x8 = 3x6 II
LOADING I(psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 110.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TPI2014
CSI.
TC 0.49
BC 0.71
WB 0.77
Matrix -AS
DEFL. in (loc) I/deft Ud
Vert(LL) 0.49 24-27 >246 240
Vert(CT) 0.43 24-27 >276 180
Horz(CT) 0.12 15 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 302 lb FT = 0%
LUMBER- I BRACING -
TOP CHORD 2x4 SP No.1 TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD 2x4 SP No.1 'Except` BOT CHORD Rigid ceiling directly applied.
Except:
12-17: 2x4 SP No.2 10-0-0 oc bracing: 17-19
WEBS 2x4 SP No.3 'Except' WEBS 1 Row at midpt 6-24. 8-23
4-24,14-15: 2x6 SP No.2
REACTIONS. (lb/size) 24=2107/0-7-10, 15=1190/0-5-8, 2=80/0-3-0
Max Horz 2=317(LC 8)
Max Uplift 24=-1616(LC 8), 15=-718(LC 8), 2=-256(LC 7)
Max Grav 24=2107(LC 1), 15=1211(LC 14), 2=113(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-308/664, 3-4=-665/977, 4-6=-560/957, 6-7=-1201/751, 7-8=-1087/745,
8-9=-1877/1268, 9-10=-1940/1318, 10-11=-1735/1200, 11-12=-1482/1015,
12-13=-1398/906, 13-14=-745/462, 14-15=-1170/722
BOT CHORD 2-24=-682/40, 23-24=-258/615, 21-23=-851/1578, 20-21=-720/1356, 19-20=-703/1262,
12-19=-347/240
WEBS 3-24=-409/540, 4-24=-325/270, 6-24=-2084/1291, 6-23=346/826, 7-23=55/270,
365/754,
81
I q,11111
3-19 —4715880, 13-16=81107/712, 1416 —5 5/1 06, 16 1425/736
A.
NOTES-
� .\• G E /�SF ••'•,'92�i
�'••. ��
1) Unbalanced roof live loads have been considered for this design. '�
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat. NO 39380
11; Exp Cs Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left exposed; parch left exposed;
Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding. —
4) Plates checked for a plus or minus 0 degree rotation about its center. '
-10 • �
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. i
- E F ;
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide 00. 40�
will fit be itween the bottom chord and any other members, with BCDL = 10.Opsf.
7) Provide mechanical truss to bearing
�i�'�(•�• ,� Q Q;•• `��
�j``s ' R `
connection (by others) of plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
• `�? �%
• •� ��\
*/I
24=161fi„ 15=718, 2=256.
lS�
111,�O N A�
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
������
sheetrock be applied directly to the bottom chord.
Thomas A. Alban[ PE No.39380
MIek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall p mybuilding design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing f iTek�
is always,required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the V�
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke EBlvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, rkrk 3ast East
Job y
Truss
Truss Type
City
Ply
J36445-Dave Golden Homes -Reed Res.
T14564055
J36445
A09
Hip
1
1
�
Job Reference (optional)
East Coast Truss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:27 2018 Page 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-4UJZDIdaZ_T6dNJnZSc5sK5ZB4wlgSkHjEHo56yyU_M
1-2- 5.3-11 9-11-10 14-5-13 19-0-0 24-8-11 30-5-5 36-2-0 36- -4 40-10-2 44-8-0
-2-8 5-0-11 4-7115 4.6-3 4-6-3 5-8-11 5-8-11 5-8-11 0- -4 4-7-14 3-9-14
Scale = 1:79.9
i
5.00 12 5xB =
3x4 = 2x4 II 5x5 =2x4 II
7 8 2728 9 10 11
24-8-11 29-8-0 36-2-4 37-2-4 40-10-2
44-8-0
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017frP12014
CSI.
TC 0.67
BC 0.45
WB 0.76
Matrix -AS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in (loc) I/defl Ud
0.49 23-26 >242 240
0.44 23-26 >272 180
0.12 14 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 291 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied, except end verticals.
BOT CHORD 2x4 SP No.1 'Except*
BOT CHORD
Rigid ceiling directly applied. Except:
11-16: 2x4 SP No.2
10-0-0 oc bracing: 16-18
WEBS 2x4 SP No.3 *Except*
WEBS
1 Row at ini 6-23
4-23,13-14: 2x6 SP No.2
REACTIONS. (lb/size) 23=2149/0-7-10, 14=1180/0-5-8, 2=48/0-3-0
Max Horz 2=317(LC 8)
Max Uplift 23=-1638(LC 8), 14=-713(LC 8), 2=269(LC 7)
Max Grav 23=2149(LC 1), 14=1204(LC 14), 2=70(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-352/730, 3-4=-708/1049, 4-6=607/1026, 6-7=-1088/683, 7-8=-1597/1111,
8-9=-1985/1320,9-10=-2040/1373,10-11=-1372/918,11-12=-1379/882,12-13=-741/459,
13-14=-1164/717
BOT CHORD 2-23=-740/81, 22-23=-178/455, 20-22=-472/1046, 19-20=-915/1638, 18-19=-717/1300
WEBS 3-23=-412/539, 4-23=-311/257, 6-23=-2068/1278, 6-22=-410/876, 7-22=-538/417,
7-20=-613/970, 8-20=-707/507, 8-19=-287/555, 9-19=-321/311, 10-19=-565/978,
12-18=445/865, 12-15=11061695, 13-15=-581/1003, 15-18=-413/781, 10-18=-356/252
111111
`tt,PS1
NOTES-
i,
1) Unbalanced roof live loads have been for this design.
E N S'••'9�j, ��
considered
�� `�( �G
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp Cj Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left exposed; left exposed;7
porch
Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
No 39380
4) Plates checked for a plus or minus 0 degree rotation about its center.
-chord
5) This truss has been designed for a 10.0 psf bottom live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
i -33 •, 44/ -
will fit beeen the bottom chord and any other members, with BCDL = 10.Opsf.
7) mechanical
���'IN p.••
Provide connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) except Ct=lb)
���
Q
'•.0 �
23=16381, 14=713, 2=269.
�j�
R
ss/ •�`
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 112" gypsum
���
�fI,I10 N Al
sheetrock be applied directly to the bottom chord.
1���,,
Thomas A. Alban[ PE No.39380
MITek USA, Inc, FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,7II-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall my
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Mirek"
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB.89 and BCSI Building Component 6904 Parke East Blvd.
Safety Infl rmation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
u
Job 1
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564056
J36445
A10
Hip
1
1
I
Job Reference (optional)
oast l Uast 1 iu—, rl. rleree, rL 04W40 6.44U 5 May 44 LV 16 Wit I eR muu5irle5, mc. rn Jul lJ 1L:JS:zu LVIn rage -i
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-YhtyQ5eCKHbzFXuz797KPYejgUE3PttRyulLeYyyU_L
�1
0
5-3-11 4-7-15 7-M 5-11-11 6-8-5 4-2-2 ' 2-4-2 '1-11-12' 3-OA 3-5-12
Scale = 1:78.5
5.00 12 5x8 = 3x4 =
3x4 = 2x4 II 3x6 = 6x6 =
' 6 7 28 8 g 10 11
voe ,�
24 - 2.00112 17 16 15 14
3x6 — 5x10 = 2x4 II 3x8 = 3x6 II
1 29-8-0 33-10-2 , 36-2-4
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc) I/defj Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.74
Vert(LL)
0.49 24-27 >246 240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.52
Vert(CT)
0.43 24-27 >280 180
BCLL 0.0
Rep Stress Incr
YES
WB 0.83
Horz(CT)
0.13 14 n/a n/a
BCDL 10.0
Code FBC2017fTP12014
Matrix -AS
Weight: 282 lb FT = 0%
LUMBER- i
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied, except end verticals.
BOT CHORD 2x4 SP No.1 'Except'
BOT CHORD
Rigid ceiling directly applied. Except:
11-16: 2x4 SP No.2
10-0-0 oc bracing: 16-18
WEBS 2x4 SP No.3 *Except*
WEBS
1 Row at midpt 4-23
4-24,13-14: 2x6 SP No.2
REACTION. (lb/size) 24=2278/0-7-10, 14=1163/0-5-8, 2=-50/0-3-0
Max Horz 2=317(LC 8)
Max Uplift 24=-1712(LC 8). 14=-693(LC 8), 2=-325(LC 7)
FORCES. 1(lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-509/943, 3-4=-829/1216, 4-6=-744/423, 6-7=-1545/1038, 7-8=-2339/1507,
8-10=-2339/1507, 10-11=-1792/1179, 11-12=1295/831, 12-13=670/417,
13-14=-11241695
BOT CHORD 2-24=-869/230, 23-24=-1201/759, 22-23=-302/636, 20-22=-894/1576, 19-20=-103511824,
18-19=-647/1182,11-18=-382/272
WEBS 3-24=-378/485, 4-24=-1747/1209, 4-23=-1127/1917, 6-23=-875/663, 6-22=-762/1262,
7-22=-834/609, 7-20=-541/916, 8-20=-301/294, 10-20=-446/758, 13-15=-560/971,
12-15=-1108/691, 15-18=-382/683, 12-18=473/911, 11-19=-551/925, 10-19=725/504
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: AS'CE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
11; Exp C;I Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left exposed; porch left exposed;
Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other jive loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
24=1712114=693,2=325.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
``o PSiA��A��1,0,
No 39380
">] / ; X z
Thomas A. Albanl PE N0.39380
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
AWARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MY-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing ivi iTek•
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabricalionj storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job , '
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564057
J36445
A11
Hip
1
1
Job Reference o tional
Cast coast russ, rt. rierce, rL o14a140
1-2 5-3-11 9-11-10 15-0-(
1-2-8 5-3-11 4-7-15 5-0-6
I
r;
u5
1`1
0
4-11-13
B.LLV 5 May L9 LU I0 IVu I ex mt1U51rteS, Inc. rn Jut 13 1L:33:37 zuits rage 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-yGZ427g4dCzY67dYoHh11 AGHshCfcE_tesFOEtyyU_I
?4-9-14 29-1-8 29 Br0 33 6-0 36-2 , 40-2-0 44 8-0
4-10-1 4-3-10 0.6-8 3-10-0 2-8-44 3-11-12 4-6-0
Scale = 1:78.5
2x4 11
5x8 = 5x8 =
3x4 = 3x4 = 3x6 = 3x4 —_ 2x4 II
5 6 7 29 8 9 10 11 12
25 24 4X4 = z.uu112 17 16 15 14
3x61 = 5x10 = 2x4 II 3x8 = 3x6 II
1-10. 15-0-0 19-11-13 24-9-14 29-8-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.56
Vert(LL) 0.29
19 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.72
Vert(CT) -0.41
18-19 >999 180
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.87
Horz(CT) 0.17
14 n/a n/a
BCDL 10.0
Code FBC2017rrP12014
Matrix -AS
I
Weight: 277 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied, except end verticals.
BOT CHORD 2x4 SP No.2
*Except*
BOT CHORD
Rigid ceiling directly applied. Except:
11-16: 2x4 SP No.3
10-0-0 oc bracing: 16-18
WEBS 2x4 SP No.3 *Except*
4-24,13-14: 2x6 SP No.2
REACTIONS. All bearings 3-7-10 except Qt=length) 14=0-5-8, 2=0-3-0, 25=0-3-8.
(lb) - Max Horz 2=317(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) except 24=-1618(LC 8), 14=-667(LC 8), 2=-465(LC 18),
25=-150(LC 5)
Max Grav All reactions 250 lb or less atjoint(s) 2, 25 except 24=2427(LC 1), 24=2427(LC 1). 14=1101(LC 1)
FORCES. I(lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-855/1455, 3-4=-1145/1708, 5-6=-985/678, 6-7=-1890/1232, 7-8=-2701/1707,
8-10=-2701/1707, 10-11=-1429/929, 11-12=-1407/921, 12-13=-769/487, 13-14=-1055/677
BOT CHORD 2-25=-1319/566, 24-25=-1319/566, 23-24=-1673/1060, 20-22=-579/1006,
19-20=-1140/1924,18-19=-1268/2104
WEBS 3-24=-396/442,4-24=-1920/1323,4-23=-1195/1945,5-23=-1169/811,5-22=828/1358,
7-20=-773/555, 7-19=-560/956, 10-19=-446/817, 15-18=-430/809, 12-18=797/1383,
12-15=-1069/670, 13-15=-527/918, 10-18=-953/640, 6-22=-994/694, 6-20=-706/1152
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
11; Exp C; Encl.; GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left exposed; porch left exposed;
Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1618 lb uplift at joint 24, 667 lb uplift at
joint 14, 465 lb uplift at joint 2 and 150 lb uplift at joint 25.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
No 39380
13
Thomas A. Albani PE No.39380
MITek USA, Inc. FL Cent 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
® WARNING . Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall p�•
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing WOW Is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the
fabrication storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job I
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T145640513
J36445
Al2
Hip
1
1
Job Reference (optional)
Last coast ilruss, ri. tierce, rL 54U41)
6-9-14 6-2-2 6-7-15
d.ZZU s May L4 LUl6 MI I eK industries, Inc. r❑ Jul 73 12:33:3'L 2U76 Page 1
�:YE5jAwrU u64TB qd P DznGdgyyXWd-RS7S GShiO W5 Pk8 C kM?CGZOpQ95XN Lg WOtW 7ZnJyyU_H
26-2-1 32-10-0 40-6-15
5x8 = 2x4 II
G nn F1 _9 3 19 4
6-6-3 6-7-15 7-8-15
3x4 = 5x8 =
20 5 21 6
Scale = 1:68.8
15 14 1' 12 11 lU 9 8
3x6
2x4 II 3x4 = 4x6 = 3x8 = 3x4 = 4x6 = 4x4 = 3x6 II
=� ,
1 6-9-14 13-0-0
19-7-15
26-2-1
32-10-0
40-6-15
6-9-14 6-2-2
6 7-15
6 6 3
6-7-15
7-8-15
Plate Offsets (X.Y)—
f3:0-5-12.0-2-81.f6:0-5-12 0-2-81
I
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.59
Vert(LL)
0.37 12-14
>999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.82
Vert(CT)
-0.47 12-14
>999 180
BCLL 0.0 '
Rep Stress Incr YES
WB 0.92
Horz(CT)
0.14 8
n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -AS
Weight: 220 lb FT = 0%
LUMBER- I
BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
BOT CHORD 2x4 SP No.2 BOT CHORD
WEBS 2x4 SP No.3 *Except* WEBS
7-8: 2x6 SP No.2
REACTIONS. (lb/size) 1=1493/0-7-10, 8=1493/0-6-9
Max Horz 1=314(LC 7)
Max Uplift 1=-930(LC 8), 8=932(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-3320/2074, 2-3=-2708/1753, 3-4=-2802/1910, 4-5=2802/1910, 5-6=-2558/1757,
6-7=1955/1256, 7-8=-1415/951
BOT CHORD 1-15=-1843/3069, 14-15=-1843/3069, 12-14=-1380/2446, 11-12=-1452/2558,
9-11=-926/1720
WEBS 2-15=0/264, 2-14=-754/514, 3-14=-174/452, 3-12=-291/605, 4-12=-378/354,
5-12=-200/366, 5-11 =-605/467, 6-11=-680/1152, 6-9=-339/317, 7-9=928/1666
Structural wood sheathing directly applied, except end verticals.
Rigid ceiling directly applied.
1 Row at midpt 7-9
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
11; Exp C 1 Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 930 lb uplift at joint 1 and 932 lb uplift at
joint 8.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
�` QO. 4�
�`,'��•'�,�G E N `SF•'9�i�'�
No 39380
i 0•• _-y-� • ���
0%%%
,O
ll, It
Thomas A. Albani PE No.39380
MITek USA, Inc. FL Cent 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
i, dv 1 4 7r11 R
A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,711-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and property incorporate this design into the overall HT ff
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication4 storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
6
Job t
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564059
J36445
A13
Hip
1
1
Job Reference o tional
test coast i1russ, ri. rierce, rL a4tIg0
5-5-13 5-6-3
5.00 12
6-OF
5x8 = 3x6 =
4 27 28 5
b.zzu s May z4 zuiu wit I eK maustnes, mc. rri jut 16 1Z:33:33 zuitf rage 1
I D:YE5jAwrUu64TBgdPDznGdgyyXWd-vehrTohK9gDGLlmwvijV6bLaXVvt46pA6Ak6JIyyV_G
22-11-0 28-9-10 34-10-0 40-4-3 45-10-0
5-10-10 5-10-10 6-0-6 5-6-3 5-5-13
2x4 II 3x6 = 3x6 = 5x8 —
6 7 8 29 9
Scale = 1:79.0
20 19 18 17 16 15 14 13 12
4x6'-- 3x6 11 4x10 = 4x6 = 3x8 = 3x6 _ 4x10 = 3x6 11 4x6
' _
3x6 = 4x6 =
5-5-13 11-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.67
Vert(LL) 0.40 16-17 >999 240
' MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.67
Vert(CT) -0.50 16.17 >960 180
BCLL 0.0 •
Rep Stress Incr YES
WB 0.98
Horz(CT) 0.12 12 n/a n/a
BCDL. 10.0
Code FBC2017/TP12014
Matrix -AS
Weight: 242 lb FT=0%
LUMBER-
I BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
BOT CHORD 2x4 SP No.2 BOT CHORD
WEBS 2x4 SP No.3 `Except' WEBS
3-20,10-12: 2x6 SP No.2
REACTIONS. (lb/size) 2=1464/0-7-10, 12=2487/0-7-10, 11=-494/0-3-0
Max Horz 2=218(LC 7) /
Max Uplift 2=975(1_C 8), 12=-1673(LC 8), l l=-588(LC 13)
Max Grav 2=1464(LC 1), 12=2487(LC 1). 11=193(LC 8)
FORCES. ;(Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3146/1939, 3-4=-2635/1684, 4-5=-2865/1919, 5-6=-2759/1852, 6-8=2759/1852,
8-9=-2114/1454,9-10=-1019/677,10-11=-988/1698
BOT CHORD 2-20=-1710/2891, 19-20=-1710/2891, 17-19=-1340/2388, 16-17=-164112865,
15-16=-1176/2114, 13-15=-379/851, 12-13=-1503/961, 11-12=-1503/961
WEBS 3-19=615/404, 4-19=-124/385,4-17=-380/726, 5-17=-326/268,6-16=-308/298,
8-16=-506/835, 8-15=-865/639, 9-15=-100411620, 9-13=879/623, 10-13=-1469/2573,
10-12=2322/1539
Structural wood sheathing directly applied.
Rigid ceiling directly applied.
1 Row at midpt 9-15. 10-13
NOTES- '
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch right
exposed; ILumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 975 lb uplift at joint 2, 1673 lb uplift at
joint 12 and 588 lb uplift at joint 11.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock, be applied directly to the bottom chord.
♦`♦�,,,PS' l A. A�����i
♦` 0
No 39380
O% Al ra •w�:
1
0 N A,111*4
��,♦.
Thomas A. Albanl PE No.39380
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
Julv 13-201S
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,7II.7473 rev. 10/03/2015 BEFORE USE. ■■■■
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing iw iTek'
is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the
fabrication (storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Informatlon available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job ,
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564060
J36445
A14
Hip
1
1
I
Job Reference (optional)
East Coast Tmss, Ft. Pierce, FL'34945
1-2 I 5-5-13 9-0-0 16-0-6
-2- 5-5-13 3 6-3 7-0-6
0
1 2
5x10 =
=
5.00 12 3x6
4 26 5 27
6.zzu 9 may z4 zu18 MI I eK mausines, Inc. Fn iui 13 1z:33:34 zultr rage 1
'BgdPDznGdgyyXWd-NrFDh8izv7L7zSL7TQEkepukvuElpaBJKgUgrCyyU_F
1 36-10-0 1 40-4-3 I 45-10-0 47-0-@
6-10-10 6-10-10
2x4 II 3x6 = 3x6 =
6 7 28 8 29
7-0-6 3-6-3 5-5-13
5x10 =
9
Scale = 1:79.0
4x6 'i
4X11
3
10
Ba
0
4x6 =
kFA
19 18 17 16 15 14 13
3x6 II 3x8 = 5x8 = 3x8 = 5x8 = 3x8 = 3x6 I
46 =
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/deft L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.76
Vert(LL)
0.51 16-17 >945 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.76
Vert(CT) -0.65 16-17 >745 180
BCLL 0.0
Rep Stress Incr YES
WB 0.91
Horz(CT)
0.11 13 n/a n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix -AS
Weight: 235 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied.
WEBS 2x4 SP No.3 "Except`
WEBS
1 Row at midpt 9-15
3-19,10-13: 2x6 SP No.2, 3-18,10-14: 2x4 SP No.2
REACTIONS. (lb/size) 2=1420/0-7-10, 13=2850/0-7-10, 11=-748/0-3-0
Max Horz 2=187(LC 7)
Max Uplift 2=-950(LC 8), 13=-1870(LC 8), 11=891(LC 17)
Max Grav 2=1420(LC 1), 13=2850(LC 1), 11=263(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3008/1859, 3-4=-2685/1725, 4-5=-3281/2163, 5-6=-3113/2060, 6-8=-3113/2060,
I 8-9=-2043/1403,10-11=-1468/2547
BOTCHO ID 2-19=1584/2731, 18-19=-1584/2731, 17-1 8=1 363/2459, 16-17=-1891/3283,
15-16=-1135/2051, 13-14=-2291/1459, 11-13=-2291/1459
WEBS 3-18=-411/266, 4-18=-114/357, 4-17=-597/1036, 5-17=-354/329, 6-16=-356/343,
8-16=-743/1220, 8-15=-994/750, 9-15=-1489/2384, 9-14=-1375/909, 10-14=-1554/2719,
10-13=-2698/1705
NOTES- I
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch right
exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 950 lb uplift at joint 2, 1870 lb uplift at
joint 13 nd 891 lb uplift at joint 11.
8) This trust design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 112" gypsum
sheetrocbe applied directly to the bottom chord.
`,A.
`r,r,llllll//j��,
No 39380
' X:
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cent 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not pal
•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall p building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing p iTek"
is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the
fabricatiorl, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job t
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564061
J36445
A15G
Hip Girder
1
2
Job Reference (optional)
Iasi L oast T russ, t't. VlerCe, I-L39y40 o.LLV s Ivwy— cv. cani.rt uiuuau,.o,uw." I--IG.JJ cVio ray.i
+i 5-5-13 '1-6-3' 54-13 5-3-1 5-3-1 5-3-1 5-3-1 541-13 '1-6-3' 5-5-13 1-2-8'
Scale = 1:78.7
I 3x6 = 46 =
5.00 12 4.8 �5x8 = 3x6 = 46 = 2x4 II 3x6 = 3x6 = 5x8 =4x8
3 4 32 33 5 3435 36 637 7 38 8 39 9 10 40 41 42 43 11 44 45 12 13
26 25 46 47 2448 49 23 22 50 51 52 21 53 54 20 19 55 56 57 18 58 59 17 16
46 = 3x10 II 5x5 = 6x6 = 08 = 4x4 = 5x5 = 04 = 4x6 =
4x4 = 44 = 6x6 = 3x10 II
LOADING (psf) SPACING- 2-0-0 CST. DEFL. in (loc) I/deft L/d
TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 Vert(LL) 0.78 21-22 >624 240
TCDL 17.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -1.04 21-22 >465 180
BCLL 10.0 Rep Stress Incr NO WB 0.63 Horz(CT) 0.14 14 n/a n/a
BCDL p.0 Code FBC2017rrP12014 Matrix -MS
LUMBER- I BRACING -
TOP CHORD 2x4 SP No.2 *Except* TOP CHORD
i 4-7,9-12: 2x4 SP No.1 BOT CHORD
BOT CHORi 2x6 SP No.2 `Except`
19-23: 2x6 SP SS
WEBS 2x4 SP No.3 `Except*
3-26,13-16: 2x8 SP DSS
4-24,5-22,6-21,10-21,11-20,12-18: 2x4 SP No.2
REACTIONS. (lb/size) 2=3100/0-7-10, 16=3724/0-7-10, 14=-0/0-3-0
Max Horz 2=-153(LC 6)
Max Uplift 2=-2001(LC 8), 16=-5155(LC 8), 14=REL
Max Grav, 2=3188(LC 36), 16=3724(LC 1). 14=1830(LC 8)
FORCES. I(lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-7637/4638, 3-4=-7573/4661, 4-5=-10141/6067, 5-6=-11633/6612, 6-8=-11473/5997,
8-1 0=-1 1473/5997, 10-11=-9875/4328, 11-12=-6620/1500, 12-13=-2620/0,
13-14=-5480/634
BOT CHORD 2-26=-4143/7110, 25-26=-4143/7110, 24-25=-4121/7094, 22-24=-5841/10202,
21-22=-6386/11693, 20-21=-4102/9935, 18-20=-1297/6680, 17-18=0/2821,
16-17=-538/5174,14-16=-538/5174
WEBS 3-25=458/450, 4-25=-415/819, 4-24=-1949/3521, 5-24=-14331943, 5-22=621/1703,
6-22=502/264, 6-21=-230/701, 8-21=-592/615, 10-21=-1903/1863, 10-20=-1480/1510.
11-20=-3225/3740, 11-18=2425/2207, 12-18=-4639/5611, 12-17=-2414/3541,
13-17=-4245/3259, 13-16=3651/4724
PLATES GRIP
MT20 244/190
Weight: 552 lb FT = 0%
Structural wood sheathing directly applied or 2-11-1 oc purlins.
Rigid ceiling directly applied or 6-0-0 oc bracing.
NOTES- ,
1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (6), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=61t; Cat.
11; Exp C Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch right
exposed;i Lumber DOL=1.60 plate grip DOL=1.60
5) Provide adequate drainage to prevent water ponding.
6) Plates checked for a plus or minus 0 degree rotation about its center.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
♦,,`,`�nnPS�A
No 39380
o
FS .p R \ O,. ;♦�
A1 EEC � ♦
1000
Thomas A. Albani PE No.39380
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
® I WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,1II-7473 rev. 1010312015 BEFORE USE. R
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, notj
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall iA'�`
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Addilional temporary and permanent bracing A
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the rLiTek•
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPIt Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Infbrmatlon available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job .
Truss
Truss Type
City
Ply
J36445-Dave Golden Homes -Reed Res.
' T14564061
J36445
A15G
Hip Girder
1
Job Reference(optional
East Coast Truss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:39 2018 Page 2
ID:YE5jAwrUu64TBgdP DznGdgyyXWd-jo26ksm5kgzP3DE4GzgvLsbaNMUwj2U6BRWPyyU_A
NOTES.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2001 lb uplift at joint 2 and 5155 lb uplift at joint 16.
10) "A" indicates Released bearing: allow for upward movement at joint(s) 14.
11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 336 lb down and 375 lb up at 7-0-0. 184 Ib down and 193 lb up at
9-0-12, I184 lb down and 193 lb up at 11-0-12, 184 lb down and 193 lb up at 13-0-12, 184 lb down and 193 lb up at 15-0-12, 184 lb down and 193 lb up at 17-0-12, 184
lb down and 193 lb up at 19-0-12, 184 lb down and 193 lb up at 21-0-12, 184 lb down and 193 lb up at 22-11-0, 184 lb down and 193 lb up at 24-9-4, 184 lb down and
193 lb up at 26-9-4, 184 lb down and 193 lb up at 28-9-4, 184 lb down and 193 lb up at 30-9-4, 184 lb down and 193 lb up at 32-9-4, 184 lb down and 193 lb up at
34-9-4, land 184 lb down and 193 lb up at 36-9-4, and 319 lb down and 309 lb up at 38-10-0 on top chord, and 374 lb down and 262 lb up at 7-0-0, 81 lb down and 29 lb
up at 910-12, 81 lb down and 29 lb up at 11-0-12, 81 lb down and 29 lb up at 13-0-12, 81 lb down and 29 lb up at 15-0-12, 81 lb down and 29 lb up at 17-0-12, 81 lb
down and 29 lb up at 19-0-12, 81 lb down and 29 lb up at 21-0-12, 81 lb down and 29 lb up at 22-11-0, 81 lb down and 29 lb up at 24-9-4, 81 lb down and 29 lb up at
26-9-4. 81 lb down and 29 lb up at 28-9-4, 81 lb down and 29 lb up at 30-9-4. 81 lb down and 29 lb up at 32-9-4, 81 Ib down and 29 lb up at 34-9-4, and 81 lb down and
29 lb up at 36-9-4, and 155 lb down and 140 lb up at 38-9-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASES) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pig
Vert: 1-4=-54, 4-12=-54,12-15=-54,2-14=-20
Concentrated Loads (lb)
Vert: 4=-167(B)7=-116(B)12=-116(B)25=-350(B)21=-61(B)8=-116(B)17=-14(B)9=-116(B)32=-116(B)33=-116(B)34=-116(B)36=116(B) 37=-116(B)
38=-116(B) 39=-116(B) 40=116(B) 41=116(B) 43=116(B) 44=-116(B) 45=-116(B) 46=61(B) 47=-61(B) 48=-61(B) 49=-61(B) 50=-61(B) 51=-61(B) 52=-61(B)
53=-61(B) 54=-61(13) 55=-61(B) 56=-61(B) 57=-61(B) 58=-61(B) 59=-61(B)
i
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111I1-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not'
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall WOW
of
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the ivi iT
fabrication storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 QualityCriteria, DSB-89 and SCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. g P 6904 Parke East Blvd.
Tampa, FL 36610
Job ,
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564062
J36445
A16
Hip
1
1
Job Reference o tional
Last GOast I fuss, Ft. Fierce, t-L 3494b O.ZZU 5 Nlay Z4 GU 10 IVII I eK muu5ine5, mu. rn UUt t0 I4:00:4I LU 10 rage I
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-gBAs9XoMGHD7JXOTNOsNRHhtzjaEyk1 LxQgXblyyLj_8
- -8 6-10-9 13-0.0 19-5-9 24- 1-2 29- 0 33-6-0 36- -4 42-2-0 44.8-0
-2-8 6-10-9 6-1-7 6-5.9 5-5-9 4-8-14 3-10-0 2-8-4 5-11-12 2-6-0
5x8 =
4x8 = 4x6 = 4x6 =
Scale = 1:78.5
4x8
2x4 II 3x6 2x4 II 5x8 =
=
m m
4 Lh
25 24 -- 22
21 -- ---' — 16 15 14 13
_ 3x6 II 4x6 = 3x8 =
3x6
2x4 II
2x4 II 3x8 = 3x6 II
3x8 =
29-9-12
0. 6-7-13 13-0-0 1953
24-11-2 2 11-
V
2 36-24 7-2 42-2-0 1 1
0. -8 6E-5 64-3 6b-9
5-5-9 -0-0
3-7-2
0-1- 2411-12 28-0
0-1-12
Plate Offsets (X.Y)— f4:0-5-12.0-2-81, 15:0-3-8.0-2-01. 16:0-3-O.Edoel It 1:0-5-12.0-2-81.
117:0-2-12.0-3-01.
(19:0-5-12,0-4-01. 124:0-3-8.0-1-81
LOADING '(psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.97
Vert(LL)
0.66
20 >688 240
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.90
Vert(CT) -0.81
20 >562 180
--
BCLL 0.0
Rep Stress Incr YES
WB 0.97
Horz(CT)
0.34
13 n/a n/a
BCDL !10.0
Code FBC2017/TPI2014
- Matrix -AS
Weight: 279 lb FT = 0%
LUMBER- I
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied, except end verticals.
BOT CHORD 2x4 SP No.2 *Except*
BOT CHORD
Rigid ceiling directly applied. Except:
7-21,10-15: 2x4 SP No.3
10-0-0 oc bracing: 19-21, 15-17
WEBS 2x4 SP No.3 *Except*
WEBS
1 Row at midpt 3-24, 4-22
3-25,12-13: 2x6 SP No.2, 3-24: 2x4 SP No.2
REACTIONS. (lb/size) 13=1239/0-5-8, 25=2917/0-7-10, 2=-756/0-3-0
Max Horz 2=317(LC 8)
Max Uplift 13=-751(LC 8), 25=1991(LC 8), 2=899(LC 18)
Max Grav 13=1239(LC 1), 25=2917(LC 1), 2=314(LC 8)
FORCES. i (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
—TOP CHORD 2-3=-1709/2664, 3-4=451/239, 4-5=-1386/913, 5-7=-3486/2178, 7-8=-4648/2857,
8-9=-4648/2857, 9-10=-2075/1284, 10-11=-2049/1282, 11-12=-583/364, 12-13=-1215/745
BOT CHO 2-25=-2382/1368, 24-25=-2382/1368, 22-24=-202/343, 7-19=-764/550, 18-19=-2166/3574,
ID
17-18=-1995/3263, 10-17=-256/245
WEBS 1 3-25=-2730/1835, 3-24=-1732/2968, 4-24=1068/762, 4-22=-85511436, 5-22=-1457/999,
19-22=-927/1494, 5-19=-142912373, 7-18=-713/1220, 9-17=-15211992, 14-17=-292/521,
11-17=-1146/1911, 11-14=-1084/712, 12-14=-633/1072, 9-18=-959/1655
%% p S� A. q,,,,,,
NOTES-
1) Unbalanced roof live loads have been considered for this design.
,0`
�'•�Ci E N S •'•, 9/jj��j
�' F '• �i
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
'•
11; Exp C Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left exposed; porch left exposed;
: No 39380
Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This trusss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
i -�3 / 44/
40
will fit between the bottom chord and any other members,
i �
Q.•�
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 751 lb uplift at joint 13, 1991 lb uplift at
�'�� O i , Q ,���
joint 25 and 899 lb uplift at joint 2.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
'� is....... • `& `%
/� S/ �` s�
sheetrock be applied directly to the bottom chord.
�I,,�� N A; t `
Thomas A. Albanl PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall p building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing R iTek"
I
always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
A
fabrication., storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Intl rmation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
i
T14564063
J36445
A17
Half Hip
1
1
Job Reference o tional
East Goast I russ, Ft. Fierce, FL 3484b
4-9-11
1-10-2 ' 2-3-13
S.ZZU s May Z4 ZU I0 w0I ex muUstnes, in0. rn JUI 10 14.00;4J zu to rdye 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-cZHdaDpcouUrYrXrVpvrWimGCXJkQgBePk9egAyyU_6
11-0-0
1 16-9-13 22-7-10 2 -7-1 30-7-11 37-6-0 44-M
0 5-9-13 5-9-13 -0.0 7-0-1 6-10-6 7-2-0
1-OE
Scale = 1:78.5
4x4 = 3x8 =
5x8 = 2x4 II 3x4 = 3x6 = 2x4 11 4x6 =
3x4
5.00 12 3x4 %5 6 2829 7 8 9 10 1130 12 13
11-0-0
6-0-5 ' 2-3-13
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.79
Vert(LL)
0.37 19-20 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.71
Vert(CT)
-0.46 19-20 >993 180
BCLL 0.0
Rep Stress Incr
YES
WB 0.86
Horz(CT)
0.11 14 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -AS
Weight: 271 lb FT = 0%
LUMBER- I
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied, except end verticals.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied.
WEBS 2x4 SP No.3 *Except*
WEBS
1 Row at midpt 6-20, 11-18, 11-15, 13-15
13-14,3-24: 2x6 SP No.2
REACTIONS. (lb/size) 14=1248/0-5-8, 24=2641/d-7-10, 2=-535/0-3-0
Max Horz 2=325(LC 8)
Max Uplift 14=-781(LC 8), 24=-1860(LC 8), 2=-638(LC 14)
Max Grav 14=1248(LC 1), 24=2641(LC 1), 2=200(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOPCHORD 2-3=-1405/2109, 3-4=-451/653, 4-5=-221/344, 6-7=-1788/1140, 7-8=-1788/1140, I
8-9=-2658/1677, 9-11=-2206/1394, 11-12=-1548/970, 12-13=-1548/970, 13-14=-1179/797
SOT CHORD 2-24=-1873/1085, 23-24=-1873/1085, 22-23=-910/528, 19-20=-1667/2639,
18-19=-1877/2960, 17-18=1417/2259, 15-17=-1417/2259
WEBS 3-24=-2425/1599, 3-23=-1100/1949, 4-23=-949/630, 4-22=-701/1012, 5-22=-1520/951,
5-21=-764/1265, 6-21 =1 143/787, 6-20=-121811954, 7-20=-350/336, 8-20=-1010/626,
8-19=-247/460, 9-19=-1076/1701, 9-18=-1915/1301, 11-17=0/283, 11-15=-857/539,
12-15=-383/382,13-15= 1131/1804
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
11; Exp Cj Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left exposed; porch left exposed;
Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Plates chlecked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truIps has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members. -
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 781 lb uplift at joint 14, 1860 lb uplift at
joint 24 and 638 lb uplift at joint 2.
7) This truss design requires that a minimum of 7116" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
r
I1
No 39380
50
O N A
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111II.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrications storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Inf rmation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564064
J36445
A18
Half Hip
1
1
Job Reference (optional)
East Coast Truss, Ft, Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:45 2018 Page 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-YyPN_vrsKWkZn8hEcExJb7raYK_SuZBxs2elk3yyU_4
1-2-8 4-9- 4 6-7-13 9-0-0 13-4-12 17-1 •5 - •10 -1 30- -11 3 •6-0 44-8-0
-2.6 4.9-14 1-9-15 2-4.3 4-4-12 4-6-9 4-6-5 -0- 7-0-1 6-10-5 7.2.0
4x8 = 2x4 I
5.00 12 5x5 = 3x8 = 2x4 II 3x4 = US =
4x6 % 4 52728 6 7 8 929 10
il�1
0
Scale = 1:78.5
3x8 = 3x4 11
11 12
23 22 21 - - 2x4 11 4x8 = 6x6 -- 17 16 15 14 13
3x8 = 3x6 II 6x81:100 F12 5x6 zz 3x8 = 4x6 = 2x4 II 5x5 =
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
YES
BCDL
10.0
Code FBC2017/TPI2014
LUMBER-1
TOP CHORD
2x4 SP No.2
BOT CHORD
2x4 SP No.2
WEBS
2x4 SP No.3 *Except*
12-13,3-23: 2x6 SP No.2
CSI.
DEFL. in
(loc) I/defl Lid
PLATES GRIP
TC 0.93
Vert(LL) 0.44
18 >999 240
MT20 244/190
BC 0.75
Vert(CT) -0.54
16-17 >835 180
WB 0.89
Horz(CT) 0.12
13 n/a n/a
Matrix -AS
Weight: 251 lb FT = 0%
BRACING -
TOP CHORD
Structural wood sheathing directly applied, except end verticals.
BOT CHORD
Rigid ceiling directly applied.
WEBS
1 Row at midpt 11-13
REACTIONS. (lb/size) 13=1196/0-5-8, 23=2985/0-7-10, 2=-828/0-3-0
Max Horz 2=274(LC 8)
Max Uplift 13=-747(LC 8), 23=-2058(LC 8), 2=-1001(LC 18)
Max Grav 13=1196(LC 1), 23=2985(LC 1), 2=364(LC 8)
FORCES. 1(lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-182212854, 34=-734/1179, 4-5=-611/988, 5-6=-2096/1314, 6-7=2096/1314,
I 7-8=-3026/1896, 8-1 0=-2563/1599, 10-11 =-2563/1599
BOT CHORi 2-23=-2586/1521, 22-23=-2586/1521, 21-22=-1502/910, 20-21=-374/578, 19-20=-374/578,
18-19=-187912999, 17-18=-2027/3207, 16-17=-1515/2412, 14-16=-112011793,
13-14=-112011793
WEBS 3-23=-2748/1784, 3-22=-131912336, 4-21=-202/325, 5-21=-2015/1271, 7-19=-1061/664,
7-18=-315/535, 8-18=-1149/1833, 8-17=-2114/1422, 10-16=-374/361, 11-16=548/880,
11-14=0/282, 11-13=-1975/1235, 4-22=-828/536, 6-19=260/248, 5-19=1103/1784
NOTES- '
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C;IEncl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left exposed; porch left exposed;
Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 747 lb uplift at joint 13, 2058 lb uplift at
joint 23 and 1001 lb uplift at joint 2.
8) This trussidesign requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock) be applied directly to the bottom chord.
9) This trussihas large uplift reaction(s) from gravity load case(s). Proper connection is required to secure truss against upward
movement at the bearings. Building designer must provide for uplift reactions indicated.
i
I9
`-101161111111l l q /111�,
No 39380
-33
/O N A � �����•
11111
Thomas A. Albanl PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing R ITeI�'
is always rettltquired for stability and to prevent collapse with possible personal injury and property damage, For general guidance regarding the 1 IC
fabrication,'storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564065
J36445
A19G
HALF HIP GIRDER
1
q
J
Job. Reference o tional
—.1 ]. I ... I . 1. 1 1—., 1 1 e
9-11-10
1-2-8 3-9-14 7-0-0 8-11-10 14-2-1,
1-241 3-9-14 3-2-2 1-11-10 -D-0 4-34
2x4 II
Sx8 =
5.00 12 4x4 = 3x8 =
3 31 4 5 32 6 33 34
4x6 =
—ff�] -" 25 50 24 51
27 48 26 49 81,8 % 2x4 II
3x8 II 5x6 J2.00 12
O.GN 5 Iway L'4 L1110 call t eK Industries, inc. rn Jul 1.5 -iz:3S:JU ZVId rage 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-vwCG2cv?82MruvaBPnXUIBYbcLjEZsUgOJMWPGyyU ?
5-1-12
2x4 II 4x8 = 3x6 =
3x6 = 3x4 = 3x4 = 2x4 II
7 8 35 36 9 37 10 38 39 11 1240 4241 13
2352 53 22
48 = 10x10 __ 21 55 56 57 20 58 19 5?
5x8 M18SHS 3x4 = 46 =
3x8 =
4-34
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud
TCLL 20.0 Plate Grip DOL 1.25 TC 0.20 Vert(LL) 0.47 22 >965 240
TCDL 7.0 Lumber DOL 1.25 BC 0.59 Vert(CT) -0.80 22 >567 180
BCLL 0.0 Rep Stress Incr NO WB 0.76 Horz(CT) 0.20 16 n/a n1a
BCDL 10.0 Code FBC20171TPI2014 Matrix -MS
LUMBER- BRACING -
TOP CHORD 2x4 SP 285OF 1.8E TOP CHORD
BOT CHORD 2x6 SP SS *Except*
22-25: 2x6 SP DSS, 19-21,16-19: 2x4 SP No.1 BOT CHORD
WEBS 2x4 SP No.3 *Except*
15-16.,2x6 SP No.2, 4-25,10-22: 2x4 SP No.2, 3-27: 2x8 SP DSS
REACTIONS. (lb/size) 16=3119/0-5-8, 27=3916/0-7-10, 2=-0/0-3-0
Max Horz 27=226(LC 8)
Max Uplift 16=-1864(LC 8), 27=-5368(LC 8), 2=REL
Max Grav 16=3173(LC 30), 27=3916(LC 1), 2=1920(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-5876/747, 3-4=-3261/0, 4-5=-4904/0, 5-6=-4942/0, 6-7=-13243/4017,
7-9=-13243/4017, 9-10=-14756/6005, 10-11=-9636/4781, 11-13=-7949/4272,
13-14=-7949/4272, 14-15=-4808/2729, 15-16=-3008/1845
BOT CHORD 2-27=631/5565, 26-27=-99/4626, 25-26=014198, 24-25=-788/10006, 23-24=-788/10006,
22-23=5945/14709, 21-22=5683/13216, 20-21=-4273/9903, 18-20=-4781/9636,
17-18=2729/4808
WEBS 3-26=-2419/3453,4-26=-4478/51,4-25=0/5443,5-25=-510/528,6-25=-5578/4489,
6-24=-3/430, 6-23=-3549/3653, 7-23=-419/425, 9-23=-1701/2119, 9-22=-781/648,
10-22=-3702/10182, 10-21=-9066/3946, 10-20=-624/0, 11-20=0/511, 11-18=-1946/589,
13-18=-564/582, 14-18=-1781/3625, 14-17=-2409/1517, 15-17=-3065/5419,
3-27=-3630/4866
S-1-12 5-5-8
Scale = 1:78.5
3x4 = 4x6 =
43 '44 14 45 46 15 47
60 61 17 62 63 16 64
4x4 = 3x6 II
PLATES
GRIP
MT20
244/190
M18SHS
244/190
Weight: 790 Ito
FT = 0%
Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 2-27,26-27.
NOTES-
1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc, 2x6 - 2 rows staggered at 0-9-0 cc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left exposed; porch left exposed;
Lumber DOL=1.60 plate grip DOL=1.60
5) Provide adequate drainage to prevent water ponding.
6) All plates are MT20 plates unless otherwise indicated.
7) Plates checked for a plus or minus 0 degree rotation about its center.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
® WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
n fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Id
%nn PS I'll A. q ���,,'
No 39380
ir
iC)
��.o
����I11111111��
Thomas A. Alban] PE No.39380
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
MITek•
6904 Parke East Blvd.
Tampa, FL 36610
Job r I
Truss
Truss Type
Qty,
Ply
J36445-Dave Golden Homes -Reed Res.
T14564065
J36445
A19G
HALF HIP GIRDER
1
Job Reference o tional
east uoas t russ, i-L merce, rL s4a4e 8.ZZo S May 24 2018 MITek Industries, Inc. Fri Jul 13 12:33:50 2018 Page 2
NOTES -
I D:YE5jAwrU u64TBgdPDznGdgyyX Wd-vwCG2cv?82 Mruva B P nXU IBYbcLj EZsUgOJ M W P GyyU_?
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1864 lb uplift at joint 16 and 5368 lb uplift at joint 27.
A" 11) " indicates Released bearing: allow for upward movement at joint(s) 2.
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 254 lb down and 387 lb up at 7-0-0, 184 lb down and 193 lb up at
8-0-12, 159 lb down and 153 lb up at 10-0-12, 159 lb down and 153 lb up at 12-0-12, 159 lb down and 153 lb up at 14-0-12, 159 lb down and 153 lb up at 16-0-12, 159
lb down and 153 lb up at 18-0-12, 159 Ib down and 153 lb up at 20-0-12, 159 lb down and 153 lb up at 22-0-12, 184 lb down and 193 Ib up at 24-0-12, 184 lb down and
193 Iblup at 26-0-12, 184 lb down and 193 Ib up at 28-0-12, 184 lb down and 193 lb up at 30-0-12, 184 lb down and 193 lb up at 32-0-12, 184 lb down and 193 lb up at
34-042, 184 lb down and 193 lb up at 36-0-12, 184 lb down and 193 lb up at 38-0-12, 184 lb down and 193 lb up at 40-0-12, and 184 lb down and 193 lb up at 42-0-12,
and 168 lb down and 189 lb up at 44-0-12 on top chord, and 81 lb down and 18 lb up at 7-0-12, 81 lb down and 29 lb up at 8-0-12, 107 lb down and 67 lb up at 9-11-10,
107 lb 'down and 67 lb up at 12-0-12, 107 lb down and 67 lb up at 14-0-12, 107 lb down and 67 lb up at 16-0-12, 107 lb down and 67 lb up at 18-0-12, 107 lb down and
67 lb up at 20-0-12, 107 lb down and 67 Ib up at 22-0-12, 81 lb down and 29 lb up at 24-0-12, 81 lb down and 29 lb up at 26-0-12, 81 lb down and 29 lb up at 28-0-12,
81 lb down and 29 lb up at 30-0-12, 81 lb down and 29 lb up at 32-0-12, 81 lb down and 29 lb up at 34-0-12, 81 Ib down and 29 lb up at 36-0-12, 81 lb down and 29 lb
up at 38-0-12, 81 lb down and 29 lb up at 40-0-12, and 81 Ib down and 29 lb up at 42-0-12, and 94 lb down and 23 lb up at 44-0-12 on bottom chord. The
design'/selection of such connection device(s) is the responsibility of others.
LOAD CASES) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform lLoads (plf)
,Vert: 1-3=-54, 3-15=-54, 2-26=-20, 25-26=-20, 22-25=-20, 21-22=-20, 16-21=-20
Concentrated Loads (lb)
Vert: 25=103(F) 3=-167(F) 5=-83(F) 24=103(F) 10=116(F) 13=-116(F) 18=61(F) 31=-116(F) 32=-83(F) 33=83(F) 34=-83(F) 35=-83(F) 36=-83(F) 37=-83(F)
38=116(F) 39=116(F) 41=-116(F.) 42=116(F) 43=-116(F) 44=-116(F) 45=-116(F) 46=-116(F) 47=-132(F) 48=-61(F) 49=-61(F) 50=-103(F) 51=-103(F) 52=-103(F)
53=-103(F) 54=-103(F) 55=-61(F) 56=61(F) 57=-61(F) 58=-61(F) 59=-61(F) 60=-61(F) 61=-61(F) 62=-61(F) 63=-61(F) 64=68(F)
® WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 117II.7473 rev. 1010312015 BEFORE USE. Bel'
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not L��-CC•��.��"»YYYCCCq
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall,
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing ivi iTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication,'storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
,
TrussTruss
Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.T14564066
FJ36445
A20
Monopitch
4
1
Job Reference (optional)
East Coast Truss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:51 2018 Page 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-N6meFyvdvMUY39OzU2jrO5hwl3EIRMpFz53yjyyL _
-1-2-8 , 5-1-7 9-10-9
1-2-8 5-1-7 4-9-2
4 Scale = 1:33.4
5
4x4 = 3x8 =
9-10-9
9-9-1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.55
Vert(LL) 0.39
5-8 >294 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.60
Vert(CT) -0.34
5-8 >340 180
BCLL 0.0
Rep Stress Incr YES
WB 0.21
Horz(CT) -0.01
5 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -AS
Weight: 49 lb FT = 0%
LUMBER- I
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied, except end verticals.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied.
WEBS 2x6 SP No.2 *Except*
3-5: 2x4 SP No.3
REACTIONS. (lb/size) 5=353/0-6-9, 2=426/0-3-0
Max Horz 2=290(LC 8)
Max Uplift 5=477(LC 8), 2=490(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown
TOP CHORD 2-3=-470/373
BOT CHORD 2-5=-546/424
WEBS 3-5=-417/523
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
11; Exp C!, Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left exposed; porch left and right
exposed Lumber DOL=1.60 plate grip DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation about its center.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
•
4) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
%%%`wA PS A. A
will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 477 lb uplift at joint 5 and 490 lb uplift at
0\v •.....,
�`�;• �� G E N 3F•
2.
joint
6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
: No 39380
sheetrock be applied directly to the bottom chord.
I
Thomas A. Albanl PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll•7473 rev. 1010312015 BEFORE USE.
,
Design valid for use only with MTekO connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
Hit
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication,, storage, delivery, erection and bracing of trusses and truss systems, see ANStITPI1 quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Truss
Truss Type
City
Ply
J36445-Dave Golden Homes -Reed Res.
FJ36445'
T14564067
�I%21
Half Hip
1
1
Job Reference (optional)
East Coast Truss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:51 2018 Page 1
I D:YE5jAwrU u64TBgdP DznGdgyyX Wd-N6me FyvdvM U iV39OzU2j rO5h ul3JIRQpFz53yjyyU_
-1-2-8 4-9-14 9-0-0 9-10-9
1-2-8 4-9-14 4-2-2 NO,
4 5 Scale = 1:31.0
r}
4x4 = 4xl0 =
0-18
4-9-14
9-10-9
5-0-11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc) I/defl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.55
Vert(LL) 0.38
6-9 >303 240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.60
Vert(CT) -0.33
6-9 >350 180
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.20
Horz(CT) -0.01
6 n/a n/a
BCDL 10.0
Code FBC2017rrP12014
Matrix -AS
Weight: 53 lb FT = 0%
LUMBER- I
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied, except end verticals.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied.
WEBS 2x4 SP No.3 *Except*
5-6: 2x6 SP No.2
REACTIONS. (lb/size) 6=353/0-6-9, 2=426/0-3-0
Max Horz 2=274(LC 8)
Max Uplift 6=471(LC 8). 2=-497(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-489/414
BOT CHORD 2-6=-573/443
WEBS 3-6=-417/530
.NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; !Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left exposed; porch left and right
exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This trussi has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 471 lb uplift at joint 6 and 497 lb uplift at
joint 2.
7) This truss design requires that a minimum of 7116" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
`%% PS11A�1q1--,,,
�E IV <e �9
No 39380
* r.
_ E. • LC/ .
Thomas A. Albanl PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE. r
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing A
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek'
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Inforination available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job ,
I
Truss
Truss Type
ply
Ply
J36445-Dave Golden Homes -Reed Res.
T14564068
J36445
A22G
Half Hip Girder
1
1
I
Job Reference (optional)
Last t;oast I cuss,
I
I
1-1. tierce, FL'3494b 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:52 2018 Page 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-rIKOSIwFgfcz7DjaXCZyNceu19Rr1 sNzTdrdT9yyTzz
1-2-8 3-9-14 7-0-0 9-10-9
1-2-8 3-9-14 3-2-2 2-10-9
Scale = 1:24.3
3x4 = 3x8 = 6 3x6 11
3-9-14
LOADING (psf)
SPACING- 2-0-D
CSI.
TCLL 20.0
Plate Grip DOL 1.25
TC 0.40
TCDL 7.0
Lumber DOL 1.25
BC 0.45
BCLL 0.0
Rep Stress Incr NO
WB 0.35
BCDL 110.0
Code FBC2017rrPI2014
Matrix -MS
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS I 2x4 SP No.3 'Except-
5-6: 2x6 SP No.2
REACTIONS. (Ib/size) 6=914/0-6-9, 2=575/0-3-0
Max Horz 2=224(LC 21)
Max Uplift 6=1244(LC 8), 2=-725(LC 8)
DEFL. in (loc) I/defl Ud PLATES GRIP
Vert(LL) 0.13 7-10 >871 240 MT20 244/190
Vert(CT) 0.11 7-10 >999 180
Horz(CT) -0.01 6 n/a n/a
Weight: 53 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-10-8 oc puffins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 5-2-3 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-938/1095, 3-4=-689/865, 4-5=-594/826, 5-6=-856/1153
BOT CHORD 2-7=-1149/855
WEBS 3-7=-281/374, 5-7=-1239/887
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left exposed; porch left and right
exposed;) Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1244 lb uplift at joint 6 and 725 lb uplift
at joint 2.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 228 lb down and 413 lb up at
7-0-0, and 147 lb down and 216 lb up at 9-0-12 on top chord, and 350 lb down and 544 lb up at 7-0-0, and 89 lb down and 116 lb
up at 9-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
I
LOADCASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pli)
Vert: 1-4=-54, 4-5=-54, 6-8=-20
Concentrated Loads (lb)
Vert: 4=-167(B) 7=-350(B) 11=-127(B) 12=-66(B)
♦♦,o ,�� PSG
No 39380
` 1 r
40
7C r
•.
,O N A� 'E�%` ��
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall p� �q�•
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing I iTek•
is always gqulred for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the Vl
fabricatywri lstorage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
I
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.T14564069
rJ36
445
B01
Common
2
1
I
Job Reference (optional)
East Coast Truss, Ft. Pierce, FL 34946
6-3-6
3x4 =
5-7-10
3x4 =
LOADING (psf) SPACING- 2-0-0 CSI.
TCLL 20.0 Plate Grip DOL 1.25 TC 0.46
TCDL 17.0 Lumber DOL 1.25 BC 0.75
BCLL 0.0 - Rep Stress Incr NO WB 0.26
BCDL 10.0 Code FBC2017/TP12014 Matrix -AS
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.1
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 6=880/0-7-10, 2=949/0-7-10
Max Horz 2=235(LC 7)
Max Uplift 6==547(LC 8), 2=-655(LC 8)
Max Grav 6=963(LC 14), 2=1029(LC 13)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1939/1108, 3-4=-1756/1036, 4-5=-1766/1049, 5-6=-1951/1124
BOT CHORb 2-9=-935/1907, 7-9=-527/1206, 6-7=-952/1756
WEBS 4-7=-332/779, 5-7=-402/374, 4-9=-313/769, 3-9=-397/364
ID:
8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:53 2018 Page 1
5-7-10
3x4; = 3x4 =
:3-10-0
6-3-6
Scale = 1:40.5
Io
3x4 =
7-6-2
8-1-15
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
Vert(LL)
-0.21
7-9
>999
240
MT20 244/190
Vert(CT)
-0.29
7-9
>978
180
Horz(CT)
0.05
6
n/a
n/a
Weight: 103 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph_TCDL=4.2_psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 547 lb uplift at joint 6 and 655 lb uplift at
joint 2.
7) Load case(s) 2, 12, 13, 14, 15, 16, 19, 20 hasthave been modified. Building designer must review loads to verify that they are correct
for the intended use of this truss.
8) This truss idesign requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrocklbe applied directly to the bottom chord.
LOAD CASES) Standard
1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=54, 4-6=-54, 10-13=-20
2) Dead + 0.75 Roof Live (balanced) + 0.75 Attic Floor: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-44, 4-6=-44, 9-13=-20, 7-9=-50, 7-10=20
12) Dead: Lumber Increase=0.90, Plate Increase=0.90 Pit. metal=0.90
Uniform Loads (pit)
Vert: 1-4=-14, 4-6=-14, 9-13=-20, 7-9=-60, 7-10=-20
OP's A- ' q4 �0
.,�•�, •' G E N &lo
.'9.y�.
No 39380
"'r ; :
ORit
s,o N A�
1111
Thomas A. Albanl PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,1II.7473 rev. 10/03/2015 BEFORE USE.
Design valid,,for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall MiTek'
design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing ivi iTek'
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
J36445-Dave Golden Homes -Reed Res.
'
T14564069
J36445
BO1
Common
2
1
Jab Reference o tional
East Coast Truss, Ft. Pierce, FL 34946 8,220 S May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:53 2018 Page 2
I D:YE5jAwrU u64TBgd P Dzn GdgyyX Wd-J Vu PgextRzkQI N l m4v4BwpA2nZjNmKz6iHaA?byyTzy
LOAD CASES) Standard
13) Dead I+ 0.75 Roof Live (bal.) + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-52, 2-4=-61, 4-6=-28, 9-13=-20, 7-9=-50, 7-10=-20
Horz: 1-2=8, 2-4=17, 4-6=16
14) Dead + 0.75 Roof Live (bal.) + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60
Uniforin Loads (plf)
Vert: 1-2=-19, 24=-28, 4-6=-61, 9-13=-20, 7-9=-50, 7-10=-20
Horz: 1-2=-25, 2-4=-16, 4-6=-17
15) Dead + 0.75 Roof Live (bal.) + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-37, 24=45, 4-6=45, 9-13=-20, 7-9=-50, 7-10=-20
Horz: 1-2=-7, 2-4=1, 4-6=-1
16) Dead + 0.75 Roof Live (bal.) + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-37, 24=45, 4-6=45, 9-13=-20, 7-9=-50, 7-10=-20
Horz: 1-2=-7, 2-4=1, 4-6=-1
19) 3rd Dead + 0.75 Roof Live (unbalanced) + 0.75 Attic Floor: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
i Vert: 14=44, 4-6=-14, 9-13=20, 7-9=-50, 7-10=-20
20) 4th Dead + 0.75 Roof Live (unbalanced) + 0.75 Attic Floor: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=14, 4-6=44, 9-13=-20, 7-9=-50, 7-10=20
I
i
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111II.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall p�•
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing iTe k•
is always rdquired for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the �y f
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qry
Ply
Golden Homes -Reed Res.T14564070
[J316445-Dave
J36445
B02
Common
3
1
Reference (optional)
East Coast Truss, Ft. Pierce, FL 34946
6-3-6
6-3.6
5-7-10
8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:54 2018 Page 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-nhSntyVCHsHMXtzecbQS 1jEvy2EVnCFxxKjXlyyTzx
5-7-10
5-10-0
Scale = 1:40.0
6
I�
3x4 = 3x4 = 3x4 = 3x4 = 3x4 =
15-8-1
LOADING '(psf)
TCLL ko
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Code FBC2017/TP12014
CSI.
TC 0.44
BC 0.77
WB 0.26
Matrix -AS
DEFL. in
Vert(LL) -0.22
Vert(CT) -0.31
Horz(CT) 0.05
(loc) I/deft L/d
7-9 >999 240
7-9 >911 180
6 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 102 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.1
BOT CHORD
Rigid ceiling directly applied.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 6=864/0-3-0, 2=932/0-7-10
Max Horz 2=230(LC 7)
Max Uplift 6=-536(LC 8), 2=-644(LC 8)
Max Gram 6=945(LC 14), 2=1013(LC 13)
I
FORCES. I(lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1902/1083, 3-4=-1720/1011, 4-5=-1644/979, 5-6=1823/1045
BOT CHORD 2-9=-923/1869, 7-9=-513/1166, 6-7=-881/1614
WEBS 4-7=-272/673, 5-7=341/338, 4-9=-318/776, 3-9=393/362
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASICE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C;I Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 536 lb uplift at joint 6 and 644 lb uplift at
joint 2.
7) Load case(s) 2, 12, 13, 14, 15, 16, 19, 20 has/have been modified. Building designer must review loads to verify that they are correct
for the intended use of this truss.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
LOAD CASES) Standard
1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plo
Vert: 1-4=-54, 4-6=-54, 10-13=-20
2) Dead + 075 Roof Live (balanced) + 0.75 Attic Floor: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-44, 4-6=-44, 9-13=-20, 7-9=-50, 7-10=-20
12) Dead: Lumber Increase=0.90, Plate Increase=0.90 Pit. metal=0.90
Uniform Loads (plo
Vert: 1-4=-14, 4-6=-14, 9-13=-20, 7-9=-60, 7-10=-20
No 39380
` * r
IIIl1��,
Thomas A. Albani PE N0.39380
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 16,2uld
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,1II-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not •
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall Lai
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job , I
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564070
J36445
B02
Common
3
1
Job Reference (optional)
East Coast;Truss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:54 2018 Page 2
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-nhSntyVCHsHMXtzecbQS 1jEvy2EVnCFIo(KjX 1 yyTzx
LOAD CASE(S) Standard
13) Dead � 0.75 Roof Live (bal.) + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-52, 24=-61, 4-6=-28, 9-13=20, 7-9=50, 7-10=-20
Horz: 1-2=8,2-4=17,4-6=16
14) Dead + 0.75 Roof Live (bal.) + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-19, 2-4=-28, 4-6=61, 9-13=20, 7-9=50, 7-10=20
Horz: 1-2=-25, 24=-16, 4-6=-17
15) Dead + 0.75 Roof Live (bal.) + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-37, 2-4=-45, 4-6=45, 9-13=20, 7-9=50, 7-10=20
Horz: 1-2=-7, 2-4=1, 4-6=-1
16) Dead + 0.75 Roof Live (bat.) + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=37, 2-4=-45, 4-6=45, 9-13=-20, 7-9=-50, 7-10=20
Horz: 1-2=-7, 2-4=1, 4-6=-1
19) 3rd Dead + 0.75 Roof Live (unbalanced) + 0.75 Attic Floor: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-44, 4-6=-14, 9-13=20, 7-9=-50, 7-10=-20
20) 4th Dead + 0.75 Roof Live (unbalanced) + 0.75 Attic Floor: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pin
Vert: 1-4=14, 4-6=-44, 9-13=-20, 7-9=50, 7-10=20
i
® WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall ��•
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the
fabrication, Storage, delivery, erection and bracing of trusses.and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job ,
Truss
Truss Type
City
Ply
J36445-Dave Golden Homes -Reed Res.
T14564071
J36445
B03
Hip
1
1
Job Reference to tional
East CoastiTruss, Ft. Pierce, FL 34946
4
0
6-3.6
8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:54 2018 Page 1
4-8-10 ' 1-10-0 1 4-8-10
56
6-3.6 1-2-8 '
Scale = 1:42.8
3x4 = 3x4 = 3x4 = 3x4 =
3x4 =
15-8-1
I�
0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.68
Vert(LL) -0.21 11-13 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.75
Vert(CT) -0.30 11-13 >939 180
BCLL 0.0
Rep Stress Incr
NO
WB 0.25
Horz(CT) 0.05 9 n/a ' n/a
BCDL 10.0
Code FBC2017rrP12014
Matrix -AS
Weight: 104 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.1
BOT CHORD Rigid ceiling directly applied.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=947/0-7-10, 9=947/0-7-10
Max Horz 2=224(LC 7)
Max Uplift 2=-652(LC 8), 9=-652(LC 8)
Max Grav 2=1031(LC 13), 9=1031(LC 14)
FORCES. !(Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1930/1091, 3-4=-1756/1023, 4-5=1594/992, 5-6=-1151/814, 6-7=-15951992,
7-8=1757/1023, 8-9=-1930/1091
BOT CHORD 2-13=-870/1895, 11-13=-489/1226, 9-11=-870/1728
WEBS 3-13=-357/336, 6-11=-292/741, 8-11=-358/336, 5-13=-292/741
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C;JEncl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 652 lb uplift at joint 2 and 652 lb uplift at
joint 9.
8) Load case(s) 2, 12, 13, 14, 15, 16, 19, 20 has/have been modifed. Building designer must review loads to verify that they are correct
for the intended use of this truss.
9) This truss) design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plo
Vert: 1-4=-54, 4-7=-54, 7-10=-54, 14-17=-20
2) Dead + 0.75 Roof Live (balanced) + 0.75 Attic Floor: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit)
Vert: 1-4=44, 4-7=-44, 7-10=-44, 13-14=-20, 11-13=-50, 11-17=-20
Att�q����,,
i No 39380
I1111111�
Thomas A. Alban] PE No.39380
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
JUIy 13,LUlt1
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTeke connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing 11 A'T�1.R'
is always reV I required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the I 1
fabrication, rstorage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564071
J36445
B03
Hip
1
1
Job Reference (optional)
C-L wdar i iu-, rr. nc-, ru 04VW B.ZZU S May 24 ZU78 MI I eK Industries, Inc. I-n Jul 13 12:33:55 2018 Page 2
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-Ft095Ky8za_8_hS9CK6f?EGLzMPgEFbP9b3H4UyyTzw
LOAD CASE(S) Standard
12) Dead:I Lumber Increase=0.90, Plate Increase=0.90 Plt. metal=0.90
Uniform Loads (plf)
Vert: 14=14, 4-7=-14, 7-10=-14, 13-14=-20, 11-13=-60, 11-17=-20
13) Dead + 0.75 Roof Live (bat.) + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-52, 2-4=-61, 4-7=45, 7-9=-28, 9-10=-19, 13-14=-20, 11-13=-50, 11-17=-20
Horz: 1-2=8, 2-4=17, 7-9=16, 9-10=25
14) Dead + 0.75 Roof Live (bat.) + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
j Vert: 1-2=19, 2-4=-28, 4-7=45, 7-9=-61, 9-10=-52, 13-14=20, 11-13=50, 11-17=-20
Horz: 1-2=-25, 24=16, 7-9=-17, 9-10=-8
15) Dead t 0.75 Roof Live (bal.) + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) 1 st Parallel): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=37, 24=45, 4-7=-45, 7-9=45, 9-10=37, 13-14=-20, 11-13=-50, 11-17=-20
Horz: 1-2=-7, 2-4=1, 7-9=-1, 9-10=7
16) Dead + 0.75 Roof Live (bal.) + 0.75 Attic Floor + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pit)
Vert: 1-2=-37, 2-4=-45, 4-7=-45, 7-9=-45, 9-10=-37, 13-14=-20, 11-13=50, 11-17=-20
Horz: 1-2=-7, 2-4=1, 7-9=-1, 9-10=7
19) 3rd Dead + 0.75 Roof Live (unbalanced) + 0.75 Attic Floor: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-44, 4-7=44, 7-10=-14, 13-14=-20, 11-13=-50, 11-17=-20
20) 4th Dead + 0.75 Roof Live (unbalanced) + 0.75 Attic Floor: Lumber Increase=1.25, Plate Increase=1.25
Uniforrp Loads (plf)
T Vert: 1-4=-14. 4-7=44, 7-10=44, 13-14=-20, 11-13=-50, 11-17=-20
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,1I1.7473 rev. 1010312015 BEFORE USE.
Design valid1for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall p
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing I iTek•
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the V I
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB.89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Ll
Job *
Tmss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564072
J36445
B04
Hip
1
1
Job Reference (optional)
East Goast I russ, Ft. Fierce, FL 34946 B.ZZU s May 24 2U18 MI I ek industries, Inc, Fri Jul 13 12:33:55 Z018 Page 1
I D:YE5jAwrUu64TBgdPDznGdgyyXWd-FtO95Ky8za_8_hS9CK6f?EGONMPOEGdP9b3H4UyyTzw
2-8 9-0-0 14-10-0 -2 23-10-0 25-0-8-12-8 4-9-14 4-0
4-9-14
Scale = 1:42.8
4x4 =
4 18
4x8 =
19 5
I$
4x4 = 3x8 =
3x4 =
04 =
3x4 =
9-0-0
14-10-0
23-10-0
1 9-0-0
5-10-0
9-0-0
Plate Offsets (X.Y)— 15:0-5-4.0-2-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES
GRIP
TCLL F0.0
Plate Grip DOL 1.25
TC 0.46
Vert(LL) -0.16
9-17 >999 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.71
Vert(CT) -0.34
9-17 >850 180
BCLL 0.0
Rep Stress Incr YES
WB 0.19
Horz(CT) 0.06
7 file n/a
BCDL
0.0
Code FBC2017/TP12014
Matrix -AS
Weight: 111 lb
FT = 0%
LUMBER- I
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied.
WEBS I 2x4 SP No.3
REACTIONS. (lb/size) 2=947/0-7-10, 7=94710-7-10
Max Horz 2=187(LC 7)
Max Uplift 2=-651(LC 8), 7=-651(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1802/1156, 3-4=-1489/945, 4-5=-1343/926, 5.6=-1489/945, 6-7=-1802/1156
BOT CHORD 2-11=-947/1678, 9-11=-652/1342, 7-9=-947/1648
WEBS 3-11=417/326, 4-11=-91/356, 5-9=-91/357, 6-9=418/326
NOTES-
1) Unbalanced .of live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
ll; Exp C;JEncl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
,,��1� �'
`,� % n Prj i�, q�� ..
\" ,
9�j�
6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
�`Z`,• �� G E N S�•; ���
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 651 lb uplift at joint 2 and 651 lb uplift at
N O 39380
joint 7.
8) This trussldesign requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock� be applied directly to the bottom chord.
•���
�••
Thomas A. Alban] PE No.39380
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1-7473 rev. 1010312015 BEFORE USE. ■■
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not,
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building des gn. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
Is always re�uired for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the ivi iTek•
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, OSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job ,
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564073
J36445 I
B05G
Hip Girder
1
1
Job Reference (optional)
CGM I ...L I IU5 , R. rjvi Ou, rL 04C40
-1-2I , 3-9-14 7-0-0 11-11-C
1-2-B 3-9-14 3-2-2 4-11-0
'J'"u s may z4 zU"Id MI I eK InaustrleS, Inc. t-n dui 1J 1z:JJ:b/ Zulu Page 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-CG7vW0_OVC FsD_cYJ1974fLgeA4Oi7BidvYO8MyyTzu
16-10-0 20-0-2 2310-0 25-M
4-11-0 3-2-2 3-9-14 1-2-8
Scale = 1:42.8
5x8 = 1x4 II 5x8 =
F nn 4 22 23 24 5 25 26 27 6
,u
3x6 = lx4 II 3x4 = 3x8.= 5x5 WB= 3x4 = 1x4 II 3x6 =
16-10-0
LOADING,(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP
TCLL 120.0 Plate Grip DOL 1.25 TC 0.73 Vert(LL) 0.36 13 >794 240 MT20 244/190
TCDL 7.0 Lumber DOL 1.25 BC 0.70 Vert(CT) -0.40 13-14 >716 180
BCLL i 0.0 Rep Stress Incr NO W0.38 Horz(CT) 0.12 8 n/a n/a
BCDL 110.0 Code FBC2017rrP1B 2014 Matrix -MS
LUMBER-1 BRACING -
TOP CHORD 2x4 SP No.2 `Except' TOP CHORD
4-6: 2x4 SP No.1 BOT CHORD
BOT CHORD 2x4 SP No.1
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIOiS. (lb/size) 2=1819/0-7-10, 8=1819/0-7-10
Max Horz 2=151(LC 7)
Max Uplift 2=-1348(LC 8), 8=-1348(LC 8)
Max Grav 2=1852(LC 29). 8=1852(LC 30)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4110/2876, 3-4=-3909/2828, 4-5=4329/3203, 5-6=4329/3203, 6-7=3909/2828,
7-8=-4112/2876
BOT CHORD 2-15=-2541/3857, 14-15=-2541/3857, 13-14=-2442/3695, 11-13=-2442/3602,
10-11=-2541/3745, 8-10=-2541/3745
WEBS 3-14=-422/354,4-14=-300/636,4-13=-644/911,5-13=-631/651, 6-13=-6441912,
6-11=-300/637. 7-11=-423/354
Weight: 119 lb FT = O%
Structural wood sheathing directly applied or 2-5-7 oc purlins.
Rigid ceiling directly applied or 3-10-14 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
,,`,,,A�TII�III/I/I',I
`�� ��`PCJA<� �I..
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
,,�,`�� •�YCi E
'� �'
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
'. �j
DOL=1.6'0 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
► NO 39380
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
—
6) ' This truiss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
-0
will fit between the bottom chord and any other members.
'mechanical
;, -33 �• 441
7) Provider connection (by others) of truss to bearing plate capable of withstanding 1348 lb uplift at joint 2 and 1348 lb uplift
�i�'�(��
at joint 8.
• Q
R `
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 336 Ib down and 375 Ib up at
nn u 9-0-12, 184 lb down
�j``s .�
and
down 111 down and 193 lb up at 12-9-4, and 184
and 193 lb up at 14 9-4 lb down 375 lb
S/O N A�
ndt336 and up1at316 0 0 on top chord, and 374 b lb up and 262 at 7 0-0, 81b
lb down and 29 lb up at 9-0-12, 81 lb down and 29 lb up at 11-0-12, 81 lb down and 29 lb up at 12-9-4, and 81 lb down and 29 lb
up at 14 9-4, and 374 lb down and 262 Ib up at 16-9-4 on bottom chord. The design/selection of such connection device(s) is the
Thomas A. Albans PE No.39380
responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
MITek USA, Inc. FL Cent 6634
6904 Parke East Blvd. Tampa FL 33610
1
Date:
LOAD CASE(S) Standard
July 13,2018
i
A WARNING - Verify design READ NOTES ON
parameters and THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with Mnek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must vedfy the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the
M iTek°
fabrication) storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPIi Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
6904 Parke East Blvd.
Tampa, FL 36610
Job ,
Truss
Truss Type
Oty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564073
J36445
B05G
Hip Girder
1
1
Job Reference c tional
test uoaSt I russ, ri. rlerce, rL 54y40 0"" J wrdy 4" GV 10 MI I GR 11Iu0D111Z 1110. ill J 1 10 IGd f Gu 10 rdy0 G
I D:YE5jAwrU u 64TBgdP DznGdgyyX Wd-CG7v WO_0 VC FsD_cYJ1974fLg eA4Oi7BidvY08MyyTzu
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
UniformlLoads (plf)
IVert: 14=-54, 4-6=-54, 6-9=-54, 16-19=-20
Concentrated Loads (lb)
Vert: 4=-167(F) 6=-167(F) 14=-350(F) 11=350(F) 22=-116(F) 24=-116(F) 25=-116(F) 27=-116(F) 28=-61(F) 29=-61(F) 30=-61(F) 31=-61(F)
®WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 10/03/2015 BEFORE USE. R
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, notB
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek`
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabricatlonl storage, delivery, erection and bracing of trusses and truss systems, see ANSlITPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type .
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564074
J36445
C01
ROOF SPECIAL
1
2
Job Reference (optional)
Cast coast I russ, Ft. Fierce, FL 34946
F--
5
2x4 11
8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:57 2018 Page 1
I D:YE5jAwrU u 64TBgdPDznGdgyyX Wd-CG7vW0_OVC FsD_CYJ1974fLj_AF5i C3idvYO8MyyTzu
7-4-0
7-4-0
2x4 II
Scale = 1:17.6
1-11-12
3-8-0
5-4-4
7-4-0
1-11-12
1-8-4
1-8-4
1-11-12
I
LOADINGI(psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.51
Vert(LL) 0.30
2 >278 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.06
Vert(CT) 0.26
2 >321 180
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.30
4 n/a n/a
BCDL 110.0
Code FBC2017/TPI2014
Matrix -AS
Weight: 55 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied, except end verticals.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 5=261/Mechanical, 4=261/Mechanical
Max Horz 5=124(LC 5)
Max Uplift 5=331(LC 4). 4=-331(LC 5)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or
less except when shown.
TOP CHORD 1-5=-269/314, 34=269/312
NOTES- '
1) 2-ply truss to be connected together as follows:
Top chords connected with 10d (0.131"x3") nails as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected with 10d (0.131"xW) nails as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads*e considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp Ci Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch left
and rightlexposed; Lumber DOL=1.60 plate grip DOL=1.60
4) Provide drainage
`�>,1111111���
adequate to prevent water ponding.
5) Plates checked for a plus or minus 0 degree rotation about its center.
��tt �{
♦♦♦ O�NS
E
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
'
♦♦,`�,. G N
7) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
8) Refer to girder(s) for truss to truss connections.
No 39380
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 331 lb uplift at joint 5 and 331 lb uplift at
joint 4.-
10) This truss design requires that a minimum of 7116" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetroick be applied directly to the bottom chord.
; �, C(/ Z
C?
S1O N q11 E�.�♦♦
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not�-
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing L♦
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the MiTek*
fabrication I storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component 69o4 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job r
Truss
Truss Type
City
Ply
J36445-Dave Golden Homes -Reed Res.
T14564075
J36445
CO2
Roof Special
2
1
Job Reference (optional) I
East Coast Truss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:58 2018 Page 1
I D:YE5jAwrU u 64TBgd P DznGdgyyX Wd-gShHjL?0 GV NjrSBktSg MdtuvzabFRfJ rsZl xgpyyTzt
3-8-0 7-4-0
3-8-0 3-8-0
4x6 =
5.00 12
3-8-0
a_r_n
znn
Scale = 1:13.6
Plate Offsets
(X.Y)— 12:0-3-O.Edgel
LOADING j(psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl L/d
PLATES GRIP
TCLL 120.0
Plate Grip DOL k 1.25
TC 0.50
Vert(LL) 0.12 2 >748 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
Vert(CT) -0.16 2 >549 180
BCLL 0.0
Rep Stress Incr NO
Horz(CT) 0.13 3 n/a n/a
BCDL �00.0
Code FBC2017/TP12014
Matrix -AS
Weight: 19 Ill FT = 0%
LUMBER- li BRACING -
TOP CHORD 2x6 SP No.2 TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied.
REACTIONS. (lb/size) 1=267/Mechanical, 3=267/Mechanical
Max Horz 1=66(LC 7)
Max Uplift 1=-116(LC 8), 3=-116(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES.
1) Unbalan ed roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
11; Exp C' Encl., GCpi=0.18; MWFRS (directional); cantilever left and,right exposed ; end vertical left and right exposed; porch left
and rightlexposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) NA
I
5) Refer to girder(s) for truss to truss connections.
6) Provide echanical connection (by others) of truss to bearing plate capable of withstanding 116 lb uplift at joint 1 and 116 lb uplift at
joint 3.
7) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20 hasihave been modified. Building designer must review
loads to verify that they are correct for the intended use of this truss.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord
9) In the LOI D CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=74(1`=-20), 2-3=-74(F=-20)
2) Dead + 0175 Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-64(F=-20), 2-3=-64(F=-20)
3) Dead + Uninhabitable Attic Without Storage: Lumber Increase=0.90, Plate Increase=0.90 Ph. metal=0.90
Uniform Loads (plf)
Vert: 1-2=-34(F=-20), 2-3=-34(F=-20)
4) Dead +0,6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60
AI,q/---,,
No 39380
441
%0`�•
11111
Thomas A. Alban) PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPIt Quality Criteria, DSB-e9 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job r 1
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564075
J36445
CO2
Roof Special
2
1
Job Reference o tional
East CoastlTruss, Ft. Pierce, FL 34946
8,220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:58 2018 Page 2
I D:YE5jAwrUu64TBgdPDznGdgyyXWd-gShHjL?OGVNjr8BktSgMdtuvzabFRfJrsZlxoovvTzt
LOAD CASE(S) Standard
Uniform Loads (plo
Vert: 1-2=-2(F=-20), 2-3=16(F=-20)
Horz: 1-2=-27, 2-3=44
5) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=16(F=-20), 2-3=-2(17=20)
Horz: 1-2=44, 2-3=27
6) Dead + 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-57(F=-20), 2-3=-13(F=-20)
Horz: 1-2=23, 2-3=21
7) Dead +0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-13(F=-20), 2-3=-57(F=-20)
Horz: 1-2=-21, 2-3=-23
8) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (pig
Vert: 1-2=32(F=20), 2-3=32(1`=20)
Horz: 1-2=-61, 2-3=61
9) Dead + 6.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=1(F=-20), 2-3=-1(F=-20)
Horz: 1-2=-28, 2-3=28
10) Dead +I0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=36(F=20), 2-3=-36(F=-20)
Horz: 1-2=2, 2 3n=-2
11) Dead +0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-36(F=-20), 2-3=-36(F=-20)
Horz: 1-2=2, 2-3=-2
12) Dead: Lumber Increase=0.90, Plate Increase=0.90 Pit. metal=0.90
Uniform, Loads (plf)
Vert: 1-2=-34(F=-20), 2-3=-34(F=-20)
13) Dead +i0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=81(F=-20), 2-3=48(F=-20)
Horz: 1-2=17, 2-3=16
14) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60
Uniform) Loads (plf)
)Vert: 1-2=48(F=-20), 2-3=-81(F=-20)
Horz: 1-2=-161 2-3=-17
15) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 1 st Parallel): Lumber Increase=1.60, Plate Increase=1.60
Uniform, Loads (plf)
!Vert: 1-2=-65(17=20), 2-3=-65(F=-20)
iHorz: 1-2=1, 2-3=-1
16) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60
UniformiLoads (plf)
Vert: 1-2=-65(F=-20), 2-3=-65(F=-20)
Horz: 1-2=1, 2-3=-1
17) 1st Dead + Roof Live (unbalanced): Lumber Increase=1.25, Plate Increase=1.25
Un'Iformll-oads (plf)
Vert: 1-2=44(1`=20), 2-3=-34(F=-20)
18) 2nd Dead + Roof Live (unbalanced): Lumber Increase=1.25, Plate Increase=1.25
UniformlLoads (plo
Vert: 1-2=-34(F=-20), 2-3=-74(F=-20)
19) 3rd Dead + 0.75 Roof Live (unbalanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pif)
IVert: 1-2=-64(F=-20), 2-3=-34(F=-20)
20) 4th Dead + 0.75 Roof Live (unbalanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform (Loads (plf)
Vert: 1-2=-34(F=-20), 2-3=-64(F=-20)
WARNING- Verfly design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. *R
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not qp
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall iA.�`
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing f V I !Take
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
i
Job l i
Truss
Truss Type
city
Ply
J36445-Dave Golden Homes -Reed Res.
T14564076
J36445
MV2
Valley
4
1
�
Job Reference o tional
East Goas6 I russ, Ft. Fierce, FL "549415
2x4
8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:34:02 2018 Page 1
I D:YE5jAwrUu64TBgdPDznGdgyyXWd-YDxoZj2XJkt8KIUV61kinj2iCBzmNTI RmBG9gayyTzp
2-0-0
2-0-0
5.00 (12
Scale = 1:6.9
LOADING I(psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TP12014
CSI.
TC 0.04
BC 0.03
WB 0.00
Matrix-P
DEFL. in (loc) Ildefl L/d
Vert(LL) n/a n/a 999
Vert(CT) n/a n/a 999
Horz(CT) -0.00 2 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 5 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or
10-0-0 oc bracing.
REACTIONS. (lb/size) 1=47/2-0-0, 2=34/2-0-0, 3=13/2-0-0
Max Horz 1=32(LC 8)
Max Uplift 1=-23(LC 8), 2=-40(LC 8)
Max Grav 1=50(LC 13), 2=41(LC 13), 3=25(LC 3)
FORCES. i(lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASICE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
11; Exp C;IEncl., GCpi=0.18; MWFRS (directional),, cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation about its center.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/fPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
mechanical
,,��►�
A q<�
7) Provide connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2.
�%P,S•
i
No 39380
1
%•!
%`�
`Ci
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always rerluired for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
l.'
f V� 6 1C
MiTek'
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
6904 Parke East Blvd.
Tampa, FL 36610
Job
I
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
)
T14564077
J36445
MV4
Valley
2
1
Job Reference (optional)
2x4
o.zCV 5 Ivldy G9 zU 10 IVII t eR inuUstrles, Inc;. rn Jul 10 1z:64:uz zUlts rage 1
I D:YE5jAwrUu64TB gdPDznGdgyyX Wd-Y DxoZj2XJkt8XIUV61 k Inj2fsBxDNTI RmB G9gayyTzp
4-0-0
4-0-0
Scale = 1:11.1
2
2x4 11
LOADING (psf)
SPACING-
2-0 0
CSI.
DEFL.
in (loc)
Ildefl
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.25
Vert(LL)
n/a
Na
999
TCDL 7.0
Lumber DOL
1.25
BC 0.19
Vert(CT)
n/a -
n/a
999
BCLL 0.0
Rep Stress Incr
YES
WE 0.00
Horz(CT)
-0.00 3
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-P
LUMBER -I BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3 BOT CHORD
I
REACTIONS. (lb/size) 1=116/4-0-0, 3=116/4-0-0
Max Horz 1=99(LC 5)
Max Uplift 1=-69(LC 8), 3=-75(LC 8)
1 Max Grav 1=119(LC 13), 3=135(LC 13)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (10) or less except when shown
PLATES GRIP
MT20 244/190
Weight: 13 lb FT = 0%
Structural wood sheathing directly applied or 4-0-0 oc purlins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 1-10; Vuut 110mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=61`1; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation about its center.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
,,,AA PS i A.
%% Q\v, . ......
�e �I
No 39380
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MrTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Qty
Ply
J36445-Dave Golden Homes -Reed Res.T14564078
�VrussType
J36445 '
MV6
2
1
Job Reference (optional)
East Coas( Truss, Ft. Pierce, FL 34946
8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:34:03 2018 Page 1
I D:YE 5jAwrUu64T B qdP DznGdgyyX Wd-OQ VAm33942??yv3hg? GXKwbi8bA16wYa?r?i MOyyTzo
6-0-0
6-0-0
3
2x4
2x4 11
LOADING j(psf)
SPACING- 2-0-0
CSI.
TCLL i20.0
Plate Grip DOL 1.25
TC 0.73
TCDL 7.0
Lumber DOL 1.25
BC 0.56
BCLL 0.0
Rep Stress Incr YES
WB 0.00
BCDL 10.0
Code FBC2017/TP12014
Matrix-P
DEFL. in (loc) I/dell Lid PLATES GRIP
Vert(LL) n/a n/a 999 MT20 2441190
Vert(CT) n/a n/a 999
Horz(CT) -0.00 3 n/a n/a
LUMBER- BRACING -
TOP CHO D 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3 BOT CHORD
REACTIONS. (lb/size) 1=190/6-0-0, 3=190/6-0-0
Max Horz 1=163(LC 7)
Max Uplift 1=-113(LC 8), 3=-123(LC 8)
Max Grav 1=195(LC 13), 3=221(LC 13)
FORCES. I (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown
Scale = 1:20.3
Weight: 20 lb FT = 0%
Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat. _
11; Exp Cf Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) Plates clecked for a plus or minus 0 degree rotation about its center.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
1=113, 3L123.
I
%%PSi A,l
E NS • q�i �i
No 39380
"111i11111
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 117II-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall pp�•
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing I VI iTek•
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication.l storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
M
Job , I
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564079
J36445
MV7
Valley
1
1
Job Reference (optional)
r t �) I iubs, rI. rtvice, rL 09y90
I
11.Z4U s May 49 ZU'It1 NII I ex mousfnes, Inc. r-ri Jul 1 J 1Z:34:U3 zuid rage 1
ID:YE5jAwrUu64T Bqd P DznG dgyyX Wd-OQVAm33942??yv3hg? GXKwbq GbG36vTa?r?i M OyyTzo
6-9-7
6-9-7
5 4
2x4 tx4 II 2x4 II
Scale = 1:21.9
LOADING (psf)
SPACING- 2-0-0
CS;'
DEFL. in
(loc) I/deft L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.21
Vert(LL) n/a
n/a 999
MT20 244/190
TCDL 17.0
Lumber DOL 1.25
BC 0.15
Vert(CT) n/a
n/a 999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.07
Horz(CT) , -0.00
4 n/a n/a
BCDL 10.0
Code FBC2017rrP12014
Matrix-P
Weight: 24 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 SP No.3
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. (Ib/size) 1=67/6-9-7, 4=95/6-9-7, 5=275/6-9-7
Max Horz 1=188(LC 5)
Max Uplift 1=-15(LC 8), 4=-64(LC 5), 5=-211(LC 8)
Max Grav 1=79(LC 14), 4=114(LC 13), 5=313(LC 13)
FORCES, i(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
Il; Exp C; IEncl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation about its center.
3) Gable requires continuous bottom chord bearing.
4) This trussl has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) will hiibetween the struss has n designed
herd r a live load of other members. .n the bottom chord in all areas where a rectangle 3-6;0 tall by 2-0-0 wide
`` ��►� Al��I�
�� pp I ,
q�e ��j�
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb)
5=211.
��� O;kS
• .
•q2 �.
-•,0ENoo
.``.`-.
No 39380
�i FS O R C??♦
N A,
Thomas A. Albani PE No.39380
MTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
WARNING- Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall /�•
building desi�gn. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing ff Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the IV I
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Truss __JTruss
Type
Oty
Ply
J36445-Dave Golden Homes -Reed Res.
FobI
1
MV8
Valley
2
1
Job Reference o tional
a tray w <� io rvu i en niuusuros, uic. rn dui to iz:oq:Uq zu ld rage l
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-Vc3Z P3nrL7sZ3euEjnms87zc bFrLVkEVIFuSyyTzn
8-0-0
8-0-0
3
2x4 % 1x4 51 42x4 II
Scale = 1:25.2
I
I
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Vdefl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.30
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 7.0
BCLL 0.0
Lumber DOL 1.25
Rep Stress Incr YES
BC 0.22
WB 0.08
Vert(CT) n/a n/a 999
Horz(CT) -0.00 4 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-P
Weight: 29 lb FT = 0%
LUMBER-1 BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP N0.3 BOT CHORD
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 1=85/8-0-0, 4=112/8-0-0, 5=331/8-0-0
Max Harz 1=226(LC 5)
Max Uplift 1=21(LC 8), 4=-76(LC 5), 5=-253(LC 8)
Max Grav 1=97(LC 14), 4=134(LC 13), 5=376(LC 13)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 1 2-5=-286/280
Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation about its center.
3) Gable reg6ires continuous bottom chord bearing.
4) This truss?has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit betvIteen the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except Ut=lb)
5=253.
No 39380
O R�•
Thomas A. Alban[ PE No.39380
MITek USA, Inc. FL Cert 6634
69D4 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev, 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall 1 at
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing i V I iTe k'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd,
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res,
T14564081
J36445
MV10
Valley
1
1
I
Job Reference o tional
East Coast Fruss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:33:59 2018 Page 1
ID:YE5jAwrUu64' BgdPDznGdgyyXWd-8eFgwhOe1pVaTlmwRABb94Q5Szt5A56?4D1UDFyyTzs
5-" 9-2-8 10-0-0
5-6-0 3-8-8 0-9-8
3 4
2x4 7 6 5
1x4 11 tx4 11 2x4 II
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.39
TCDL
17.0
Lumber DOL
1.25
BC 0.28
BCLL
10.0
Rep Stress Incr
YES
WB 0.09
BCDL
10.0
Code FBC2017/TP12014
Matrix-S
DEFL. in (loc) I/deft Ud PLATES GRIP
Vert(LL) n/a n/a 999 MT20 244/190
Vert(CT) n/a n/a 999
Horz(CT) -0.00 5 n/a n/a
LUMBER- I BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3 BOT CHORD
OTHERS 2x4 SP No.3
REACTIONS. All bearings 10-0-0.
(lb) - Max Horz 1=270(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 6 except 7=-295(LC 8)
Max Grav All reactions 250 lb or less atjoint(s) 1, 5, 6 except 7=437(LC 13)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-7=-325/313
Scale = 1:28.6
Weight: 42 lb FT = 0%
Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
Rigid ceiling directly applied or 6-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60i plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 6 except
Qt=lb) 7=295.
`,,tAAPSr A1;tq��l,,'
No 39380
r • �� ` • 41
'eel /O N A� "� �
Thomas A. Albani PE No.39380
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. �*
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not[��•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall i�.i■`
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing iTe k'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the p
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSlfTPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
J36445-Dave Golden Homes -Reed Res.
T14564082
J36445
MV10A
GABLE
1
1
_,
Job Reference o tional
2x4
O.LGu s IVldy G9 zu to ivu I ex Inciustnes, Inc. t•n Jul 13 iz:,i=.0 zults Yage 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-BeFgwhOelpVaTlmwRABb94Q4xzstA5074D1UDFyyTzs
9-11-2
9-11-2
3
4 2x4 11
Scale = 1:30.5
LOADING I(psf)
SPACING- 2-0-0
CSI.
DEFL,
in (loc)
I/defl
Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.48
Vert(LL)
n/a
n/a
999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.36
Vert(CT)
n/a
n/a
999
BCLL 0.0
Rep Stress Incr YES
WB 0.10
Horz(CT)
-0.00 4
n/a
n/a
BCDL 10.0
Code FBC2017rrPI2014
Matrix-S
Weight: 38 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 SP No.3 except end verticals.
WEBS j 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 1=156/9-11-2, 4=93/9-11-2, 5=421/9-11-2
Max Horz 1=288(LC 5)
Max Uplift 1=-63(LC 8), 4=-73(LC 5), 5=-322(LC 8)
Max Grav 1=156(LC 1), 4=115(LC 13), 5=478(LC 13)
FORCES. '(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-5=-356/333
NOTES.
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; IEncl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation about its center.
3) Gable requires continuous bottom chord bearing.
4) This truss! has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb)
5=322.
Auq������
%% Q��;
No 39380
r * r
Ai
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 1010312015 BEFORE USE.
Design validlfor use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
•
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall p p
iTek•
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the ivi
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see 'ANSVTPII quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Inforination available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
a
Job ,
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564083
J36445 I
MV12
Valley
1
1
Job Reference o tional
-• - o.ccu s rviay 49 zv to rwi t en muusnies, inc. rn dui is Iz:34:uu zulb rage 1
I D:YE5jAwrU u 64TBgd P Dzn GdgyyXWd-crp281 OGo7 dQ5S L6?tigilzJs N F7vYM8Jtn2lhyyTzr
5-6-0 I 9-2-8 12-0-0
5-6-0 3-8-8 _ 2-9-8
I I Scale = 1:26.9
3x4 7 6 52x4 II
1x4 II 1x4 II
5-6-0 9-2-8 12-0-0
5_6_0 3-8-8 2-9-8
LOADING fpsf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Vdefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.22
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.17
Vert(CT) n/a n/a 999
BCLL 10.0
Rep Stress Incr YES
WB 0.09
Horz(CT) -0.00 5 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-S
Weight: 48 lb FT = 0%
LUMBER- I BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3 BOT CHORD
OTHERS 2x4 SP No.3
REACTIONS. All bearings 12-0-0.
(Ib - Max Horz 1=270(LC 5)
Max Uplift All uplift 100 lb or less atjoint(s) 1, 5 except 6=-134(LC 5), 7=-294(LC 8)
Max Grav All reactions 250lb or less atjoint(s) 1, 5, 6 except 7=435(LC 13)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 1 2-7=-324/313
Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft: B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift atjoint(s) 1, 5 except (jt=lb)
6=134,7=294.
0
•E S • �2��i �,.� G N F , • �
No 39380
o
Thomas A. Albani PE No.39380
MITek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
® WARNING - verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
! t
t
Job !
s
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T
T14564084
J36445
4
Valley
1
1
�
Job Reference o tional
cast Wall I IuJs, rr. rjuiuv, rL Jvygo 041"
s may z4 zultf Mt i eK Inausine
I D:YE5jAwrU u64TBs, Inc. rn Jut 13 1z:34:UU zU16 rage 1
gdPDzn GdgyyX Wd-crp2810G o7 dQ5 S L6?Uq i IzJYN F9vYP8Jtn2lhyyTzr
5-6-0 9-2-8 14-0-0
5-6-0 3-8-8 3 4-9-8 4
5.00 12
1
3x4 % 7
1x4 II
11 Scale = 1:28.7
5
2x4 II
6-6-0
9-2-8
14-0-0
5-6-0
3-8-8
4-9-8
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.24
Vert(LL) n/a
n/a 999
MT20 244/190
TCDL 17.0
Lumber DOL
1.25
BC OA6
Vert(CT) n/a
n/a 999
BCLL 0.0
Rep Stress Incr
YES
WB 0.09
Horz(CT) -0.00
5 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-S
Weight: 54 lb FT = 0%
LUMBER- I
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORb 2x4 SP No.2
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 14-0-0.
(16) - Max Horz 1=270(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) 1 except 5=-11 O(LC 5), 6=181(LC 5), 7=-287(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=293(LC 13), 7=422(LC 13)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown
WEBS 2-7=-316/304
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This trusts has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except Qt=lb)
5=110, 6=181, 7=287.
NS, A"A,1.*,f'0i
No 39380
►-0 • • ��
i� • : 411♦
Thomas A. Alban] PE No.39380
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing I'I'e �'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Infonr ation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
July 13,2018
Job
s
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
F
T14564085
J36445
6
Valley
1
1
Job Reference o tional
East Coast Truss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:34:01 2018 Page 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-41 NQLN1 uZQlHicvJYbD3EV WUanbMe?cHYXWbH7yyTzq
5.6-0 9-2-8 12-7-4 16-0-0
3 5-6-0 3-8-B _ 4-12 3-4-12 _
II Scale = 1:29.9
3x4 9 8 7 6
1x4 11 1x4 11 1x4 11 2x4 11
6-&0
9-2-8
12-7-4
16-0-0
5-6-0
3-8-8
34-12
3-4-12
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
([cc)
I/deft
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.22
Vert(LL)
n/a
n/a
999
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.17
Vert(CT)
n/a
n/a
999
BCLL 10.0
Rep Stress Incr
YES
WB 0.09
Horz(CT)
-0.00
6
n/a
n/a
BCDL 10.0
Code FBC2017rTP12014
Matrix-S
Weight: 65 lb FT = 0%
LUMBER-1 BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 cc purlins,
BOT CHORD 2x4 SP No.2 except end verticals.
'WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 16-0-0.
(16) - Max Horz 1=270(LC 5)
Max Uplift All uplift 100 lbor less at joints) 1, 6 except 8=-141(LC 5), 9=-294(LC 8), 7=182(LC 4)
Max Grav All reactions 250lb or less atjoint(s) 1, 6, 8 except 9=434(LC 13), 7=279(LC 1)
I
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 1 2-9=-324/311
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; t ncl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires continuous bottom chord bearing.
%0111111111 f II11J
5) This trusslhas been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
.
p NS A, ,q4 ���,'
6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
%%0,
`v e
E N g �'•; 9� ��
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 6 except (jt=lb)
♦��,`� .•'�(,
•• �' i
8=141, 9=294, 7=182.
No 39380
-� • LZ
-33
Thomas A. Mani PE No.39380
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
Jury io,LV Io
AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE.
Design valid;for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall i��■`
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB.89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
b
Truss
Truss Type
City
Ply
J36445-Dave Golden Homes -Reed Res.
�
[J36445
T14564086
ZCJ1
Jack -Open
6
1
Job Reference o lional
East Coast Truss, Ft. Pierce, FL 34946
8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:34:05 2018 Page 1
I D:YE5jAwrUu64TBgd P DznGdgyyX Wd-zo cxB l4PcfFjBD D4 nQ I?PLgA50_Qap2tT9 Up QvyyTzm
12-8 100
Scale = 1:6.5
2x3 =
i
LOADING (psf)
SPACING- 2-0-0
CSI.
TCLL 20.0
Plate Grip DOL 1.25
TC 0.19
TCDL 7.0
Lumber DOL 1.25
BC 0.03
BCLL 1 0.0
Rep Stress Incr YES
WB 0.00
BCDL 10.0
Code FBC20171TPI2014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
i
REACTIONS. (lb/size) 3=3/Mechanical, 2=142/0-7-10, 4=7/Mechanical
Max Horz 2=72(LC 8)
Max Uplift 3=4(1_C 5), 2=-191(LC 8), 4=-7(LC 1)
1-0-0
1_n_n
DEFL. in (loc) Well Ud PLATES GRIP
Vert(LL) 0.00 5 >999 240 MT20 244/190
Vert(CT) 0.00 5 >999 180_
Horz(CT) 0.00 4 n/a n/a
Weight: 5 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
Max Grav 3-12(LC 4), 2-142(LC 1), 4-32(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES -
I
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This trusslhas been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except Qt=lb)
2=191. j
``,tJ111111111jII,I
�`
�.,�� .• �G E NS
No 39380
` � r
411
OR
I �
O N A ►1- 0%
11111
Thomas A. Albanl PE No.39380
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
lulu 13 201R
A WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,7II.7473 rev, 1010312015 BEFORE USE.
Design valid for use only with MTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must vanity the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTeiC-
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314, Tampa, FL 36610
Job ;
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
i
T14564087
J36445
ZCJ1A
Jack -Open
6
1
i
Job Reference o tional
o.ccu b may cv cu io lvn l en muubmes, lrIG. "'Jul
I a 1L:aq:UD LUId rage 1
ID:YE5jAwrUu64TBgdPDznGdgyyX Wd-zocxBl4PcfFjBDD4nQI?PLgA50_Pap2tT9UpQvyyTzm
1-2-8 1-0-0
Scale = 1:6.5
2x3 =
1-0-0
0-10-8
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.19
Vert(LL) 0.00
5 >999 240
MT20 244/190
TCDL 17.0
Lumber DOL 1.25
BC 0.03
Vert(CT) 0.00
5 >999 180
BCLL 10.0
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00
4 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 5 lb FT = 0%
LUMBER- I
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 1-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=3/Mechanical, 4=-7/Mechanical, 2=142/0-3-0
Max Horz 2=72(LC 8)
Max Uplift 3=-11(LC 5). 4=-15(LC 13), 2=-213(LC 8)
Max Grav 3=7(LC 3), 4=18(LC 8), 2=142(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch left
and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss1has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit the ttom chord and any other members.
6) Refereoglyder(s) fortv6en
tru s to truss connections.
truss
7) Provide bearing
mechanical connection (by others) of truss to plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except (jt=lb)
2=213. I
Q`"',
�` . ' G E•N .'9
No 39380
_ r
i • P� Cc Z
F
,O�'�ss O N
Thomas A. Albani PE No.39380
MITek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
®WARNING -Verify design pararpefers and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111II.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTeM connectors. This design is based only upon parameters shown, and is for an individual building component, not �
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall Nil -
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Mirek•
is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPII Quality Criteria, DSB.89 and BCSI Building Component 6904 Parke East Blvd.
Safety Inforination available from Truss Plate Institute, 218 N. Lee Street, Suhe 312, Alexandria, VA 22314. Tampa, FL 36610
Job I
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564088
J36445
ZCJ3
Jack -Open
6
1
Jab Reference (optional)
East CoastlTruss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:34:06 2018 Page 1
i - ID:YE5jAwrUu64TBgdPDznGdgyyXWd-R?AJO551NzNapNoGL8pExZDLroJKJGllhpEMzLyyTzl
iI
1-2-8 3-0-0
2x3 =
Scale = 1:10.8
3-0-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc) I/deft L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.19
Vert(LL) -0.00
4-7 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.12
Vert(CT) -0.01
4-7 >999 180
BCLL ;0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 11 lb FT = 0%
LUMBER- I
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 3-0-0 oc purlins.
BOT CHORD 2x4•SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=62/Mechanical, 2=187/0-7-10, 4=33/Mechanical
Max Horz 2=121(LC 8)
Max Uplift 3=-60(LC 8), 2=-178(LC 8), 4=-3(LC 5)
Max Grav 3=74(LC 13), 2=191(LC 13), 4=50(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES- i
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This trusslhas been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except Qt=lb)
2=178.
,`11111111111�1�,
No 39380
:�•�IX, F '•<C/:
.0R�0, •N
C� .
1111111110
Thomas A. Albani PE NO.39380
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
®-ARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall WW �V I[
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing iTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the IYI
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
T14564089
J36445
ZCJ3A
Jack -Open
6
1
Job Reference o tional
❑a51 Boas[ i Fuss, rt. rlerce, rL s14ag0 mzzu s May z4 zuiu MI I eK maustrles, Inc. t-n Jul 13 12:34:UI ZVIU Page 1
I D:YE5jAwrUu64TBgdPDznGdgyyXWd-vBkhcQ6f8GVRQXNTvrKTUmIWbCfZ2jYAwTzM/nyyTzk
i -1-2-8 3-0-0
1-2-8 3-0-0
iI
2x3 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
floc)
I/defl
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.19
Vert(LL)
0.01
4-7
>999
240
TCDL 7.0
Lumber DOL
1.25
BC 0.12
Vert(CT)
-0.01
4-7
>999
180
BCLL 10.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MP
LUMBER-1
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 3=62/Mechanical, 4=33/Mechanical, 2=187/0-3-0
Max Horz 2=121(LC 8)
Max Uplift 3=72(LC 8), 4=-54(LC 5), 2=-242(LC 8)
Max Grav 3=65(LC 13), 4=50(LC 3), 2=187(LC 1)
Scale = 1:10.8
PLATES GRIP
MT20 244/190
Weight: 11 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=WOmph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch left
and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This trusslhas been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except at=lb)
2=242.
% NS t A. q4
No 39380
F
AX�
Thomas A. Albanl PE No.39380
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall �•
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the piTek"
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
K
TrussTruss
Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.T14564090
FJ36445
ZCJ5
Jack -Open
6
1
�
Job Reference (opt!
Last Coast I I Fuss, Ft. Fierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:34:07 2018 Page 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-vBkhcQ6f8GVRQXNTvrKTUmISZCbQ2jYAwTzwVnyyTzk
-1-2-8 5-0-0
5-0-0
Frale c 1• 17 R
I
2x4 =
5-0-0
5-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.44
Vert(LL) 0.04
4-7 >999 240
MT20 2441190
TCDL 17.0
Lumber DOL 1.25
BC 0.38
Vert(CT) -0.05
4-7 >999 180
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -AS
Weight: 18 lb FT = 0%
LUMBER- I
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied.
REACTIONS. (lb/size) 3=116/Mechanical, 2=256/0-7-10, 4=59/Mechanical
Max Horz 2=171(LC 8)
Max Uplift 3=120(LC 8), 2=-203(LC 8), 4=6(1_C 8)
Max Grav 3=137(LC 13), 2=264(LC 13), 4=86(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This trussl has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except Gt=lb)
3=120, 2=203.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
%011111111111.4,
.�%%% ONS A. 44e
� ' G E N
No 39380
� r
r * ry-
44/
O N lots
Thomas
Thomas A. Albani PE No.39380
MRek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 114II.7473 rev. 1010312015 BEFORE USE. �*
Design validlfor use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not q�•
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Welk'
always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 36610
I
Truss
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
r
Fb
]TrussType
T14564091
I
ZCJ5A
Jack -Open
6
1
Job Reference (optional)
Last coast! I russ, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:34:08 2018 Page 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-NN13pm7Hvadl2gyfrZdl_IdJcwZnAnJ97jT1DyyTzj
5-0-0
r 1-2-8 5-0-0
Scale = 1:17.8
2X4 =
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.44
Vert(LL) 0.09
4-7 >679 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.39
Vert(CT) 0.08
4-7 >784 180
BCLL 10.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -AS
Weight: 18 lb FT = O%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied.
REACTIONS. (lb/size) 3=116/Mechanical, 4=59/Mechanical, 2=256/0-3-0
Max Horz 2=171(LC 8)
Max Uplift 3=-139(LC 8), 4=95(LC 8), 2=311(LC 8)
Max Grav 3=123(LC 13), 4=86(LC 3), 2=256(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed; end vertical left and right exposed; porch left
and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss teas been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except Qt=lb)
3=139, 2=311.
8) This truss tlesign requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock i e applied directly to the bottom chord.
,��II11111111r,
A.
No 39380
AN
C? � E,0��.
�rrrlllllll��
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
.Ilfiv 13 2018
®WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid jor use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
is always re#red for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
TrussTruss
Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.T14564092
r
445
ZEJ6G I
Monopitch Girder
2
1
Job Reference (optional)
East Coast � russ, Ft. Pierce, FL 34946
1
o
ob
N
3x4 =
Special
8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:34:09 2018 Page 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-rasS 167wgul9ggXrOGNxZBroL?DW Wd1 TNmSOZgyyTzi
3-0-7 5-8-9
3-0-7 2-8-2
5-8-9
5-7-1
3
2x4 II
Scale = 1:22.9
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip COL 1.25
TC 0.43
Vert(LL) 0.13
3-5 >522 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.63
Vert(CT) -0.10
3-5 >634 180
BCLL 10.0
Rep Stress Incr NO
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 27 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 5-8-9 oc purlins,
BOT CHORD 2x6 SP No.2
except end verticals.
WEBS 2x6 SP No.2
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=477/0-6-9, 1=672/0-3-0
Max Horz 1=141(LC 8)
Max Uplift 3=-526(LC 8), 1=-434(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES'
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left exposed; porch left and right
exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation about its center.
3) This trusslhas been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit betlireen the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
3=526, 1 =434.
6) Use USP 1S1_11124 (With 10d nails into Girder & NA9D nails into Truss) or equivalent at 2-0-12 from the left end to connect truss(es)
to front face of bottom chord.
7) Use USP THD26-2 (With 16d nails into Girder & 10d nails into Truss) or equivalent at 4-1-11 from the left end to connect truss(es) to
front face of bottom chord.
8) Fill all nail holes where hanger is in contact with lumber.
9) Hanger(s)yor other connection device(s) shall be provided sufficient to support concentrated load(s) 256 lb down and 103 lb up at
0-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASES) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-54, 1-3=-20
Concentrated Loads (lb)
Vert: 1=-256(F) 6=-247(F) 7=-241(F)
%%%%01111' A'11 q1
J,` •E N • <e 2
No 39380
44/
t�si.<.pR10• •' ;%
Thomas A. Albanl PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
®WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111II-7473 rev. 1010312015 BEFORE USE. �*
Design valid jfor use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not e�•
a ss trusystem. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall pi•�`
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing �y�
is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the MiTek*
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP111 Quality Criteria, DSB.89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
J36445-Dave Golden Homes -Reed Res.
0 I
T14564093
J36445
ZEJ7
Jack -Open
36
1
Job Reference (optional)
CLJi liUGsl I IUsb, rt. ri-, rL 04V4D D.LGU s May 411 GU to Nn i ex umusnies, Inc. rrl dui iJ 7L:34:Ve LV to rage I
I D:YE5jAwrUu64TBgdPDznGdgyyXWd-rasS 167wgul9ggXrOGNxZBrgS?AHWd 1 TNmSOZgyyTzi
1-2-8 7-0-0
1-2-8 7-0-0
0
0
N
3x3 = 4
7-0-0
7-0-0
Scale: 1/2"=1'
Plate Offsets (X Y)— 12:0-1-2.Edgel
LOADING ��Psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.93
Vert(LL) 0.16
4-7 >536 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.80
Vert(CT) -0.21
4-7 >396 180
BCLL I0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017rTP12014
Matrix -AS
Weight: 24 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORb 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied.
REACTIONS. (lb/size) 3=170/Mechanical, 2=328/0-7-10, 4=81/Mechanical
Max Horz 2=222(LC 8)
Max Uplift 3=-178(LC 8), 2=-235(LC 8), 4=-9(LC 8)
Max Grav 3=200(LC 13), 2=340(LC 13), 4=121(LC 3)
FORCES. �Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES- i
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60, plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide `11111111111111
will fit between the bottom chord and any other members. ,%k% A NS A. ,q4
6) Refer to giirder(s) for truss to truss connections. ") e
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except at=lb) ��`�c`O •, \ C E N S •
3=178, 2=235. �' •. �i
8) This truss ilesign requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum ` NO 39380
sheetrock be applied directly to the bottom chord. r * r
��uiirl�ll
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
hdv 1� 7f11R
A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid for use oni'y with Mi rek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not •
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall �i.�`
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the AiTe k'
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314. Tampa, FL 36610
Job
Truss
Trus Type
Ply
J36445-Dave Golden Homes -Reed Res.
� I
]J,,sk-Open
�Qty
T14564094
J36445
ZEJ7A
2
1
Job Reference o tional
Last Goastll russ, Ft. Pierce, F•L M46 d.ZZU S may Z4 ZU18 mi I eK industries, Inc. F❑ Jul 13 12:34:1U Zu1t5 Page 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-JmQgES8YRBtOH_61a_uA6PNgYPVDF4HccQCa66yyTzh
1-28 700
1-2-8 7-0-0
3x3 = 4
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Lid
TCLL 20.0
Plate Grip DOL
1.25
TC 0.97
Vert(LL)
0.35
4-7
>241
240
TCDL I7.0
Lumber DOL
1.25
BC 0.82
Vert(CT)
0.30
4-7
>277
180
BCLL 10.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.01
3
n/a
n/a
BCDL 10.0
Code FBC2017frP12014
Matrix -AS
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3 BOT CHORD
REACTIONS. (lb/size) 3=170/Mechanical, 4=81/Mechanical, 2=328/0-3-0
Max Horz 2=222(LC 8)
Max Uplift 3=-204(LC 8), 4=-134(LC 8), 2=-386(LC 8)
Max Grav 3=180(LC 13), 4=121(LC 3), 2=328(LC 1)
FORCES. Slb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:22.0
PLATES GRIP
MT20 2441190
Weight: 24 lb FT = 0%
Structural wood sheathing directly applied.
Rigid ceiling directly applied.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch left
and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed toprovide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to gi�der(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
3=204,4=134,2=386.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock i e applied directly to the bottom chord.
t"PSG Al;,qi��,,,
No 39380
Thomas A. Alban] PE No.39380
MITek USA, Inc. Fl. Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
lulu 13 91"11 R
WARNINC7 -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,1II.7473 rev. 1010312016 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall i�.�
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing A
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the piTek•
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
0
Z
Truss
Truss Type
City
Ply
J36445-Dave Golden Homes -Reed Res.
�
I
Fi
T14564095
445
ZEJ7T
Jack -Open
7
1
Job Reference (optional)
East Coast, Truss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:34:11 2018 Page 1
I D:YE5jAwrUu64TBq dPDznGdgyyX Wd-ny_C S o9ACV?tv8g E8h PQecw5pps I—WOmr4x7 eYyyTzg
1-2-e 2-7-10 3-7-10 7-M
1-2-8 2-7-10 1-0-0 3A-6
I
2x3 =
2-7-10 3-7-10 7-0-0
i 9_7-1n 1_n-n A-A1i
Scale = 1:22.0
Plate Offsets (X.Y)— 13:0-2-0.0-1-51
LOADING ipsf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.62
Vert(LL) 0.16
5-6 >528 240
MT20 244/190
TCDL 17.0
Lumber DOL 1.25
BC 0.70
Vert(CT) -0.20
5-6 >411 180
-
BCLL , 0.0
Rep Stress Incr YES
WB 0.07
Horz(CT) 0.05
5 n/a n/a
BCDL 10.0
Code FBC20171TPI2014
Matrix -AS
Weight: 27 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied.,
BOT CHORD 2x4 SP No.3 *Except*
BOT CHORD
Rigid ceiling directly applied.
3-5: 2x4 SP No.2
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 4=137/Mechanical, 2=34010-7-10, 5=123/Mechanical
Max Horz 2=222(LC 8)
Max Uplift 4=137(LC 8), 2=231(LC 8), 5=47(LC 8)
Max Grav 4=160(LC 13), 2=352(LC 13), 5=144(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 3-9=-381/134
BOT CHORD 2-7=-254/362, 6-7=324/476, 3-6=-303/210
WEBS i 3-7=-295/245
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; End, GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60, plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss kas been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5 except Qt=lb)
4=137, 2=231.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
A��q��--,,
.% • • •E N • Ce ��
No 39380
r, . koo
S •••• `�
Thomas A. Albanl PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
.joy 13 gO1R
WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
I
Job
Truss
Truss Type
City
Ply
J36445-Dave Golden Homes -Reed Res.
T14564096
J36445
ZHJ7
Diagonal Hip Girder
3
1
Job Reference o tional
East Coast Truss,
Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:34:12 2018 Page 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-GBXaf8Aozp7jXl FQiOwfBgTJPDGwjvYv4khgA?yyTzf
-1-8-8 5-2-9 9-10-1
1� -8-8 5-2-9 4-7-8
2x4 = 1x4 II — — 5
5-2-9
9-10-1
Scale: 1/2"=l'
LOADING I(psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc) I/deft Lid
PLATES GRIP
TCLL F0.0
Plate Grip DOL
1.25
TC 0.44
Vert(LL) 0.05
6-7 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.49
Vert(CT) -0.08
6-7 >999 180
BCLL 0.0
Rep Stress Incr
NO
WB 0.34
Horz(CT) 0.01
5 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 41 lb FT = 0%
LUMBER- I
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 5-9-8 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 7-6-3 oc bracing.
WEBS I 2x4 SP No.3
REACTIONS. (lb/size) 4=128/Mechanical, 2=412/0-10-7, 5=317/Mechanical
Max Horz 2=221(LC 8)
Max Uplift 4=-134(LC 8), 2=418(LC 8), 5=-205(LC 8)
Max Grav 4=128(LC 1), 2=486(LC 28). 5=356(LC 28)
I
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-951/500
BOT CHORD 2-7=-601/877, 6-7=-601/877
WEBS 3-7=-29/285, 3-6=-934/640
NOTES- ,
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation about its center.
3) This trusslhas been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to giIrder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ut=lb)
4=134, 2=,418, 5=205.
7) Hanger(s)lor other connection device(s) shall be provided sufficient to support concentrated load(s) 105 lb down and 57 lb up at
1-4-15, 105 lb down and 57 lb up at 1-4-15, 124 lb down and 87 lb up at 4-2-15, 124 lb down and 87 lb up at 4-2-15, and 165 lb
{ down and i155 lb up at 7-0-14, and 165 lb down and 155 lb up at 7-0-14 on top chord, and 38 lb down and 34 lb up at 1-4-15, 38 lb
down and 34 lb up at 1-4-15, 25 lb down and 11 lb up at 4-2-15, 25 lb down and 11 lb up at 4-2-15, and 47 lb down and 21 lb up at
7-0-14, and 47 lb down and 21 lb up at 7-0-14 on bottom chord. The design/selection of such connection device(s) is the
responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plo
Vert: 1-4=-54, 5-8=-20
Concentrated Loads (lb)
Vert: 11=113(F=57, B=57) 12=-1(F=-0, B=-0) 13=-79(F=-40, B=40) 15=-14(F=-7, B=-7) 16=-61(F=-30, B=-30)
I
%%%�,�,,,���N A'lA�����i
No 39380
� * r
i �� • 441
i
Thomas A. Albanl PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
® WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verily the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Info alion available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job i Truss
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
Fruss.Type
J36445 ZHJ7A
Hip Girder
2
1
Job Reference o tional
East CoastlTruss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MTek Industries, Inc. Fri Jul 13 12:34:12 2018 Page 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-GBXafBAozp7jXIFQiOwfBgTISDGwjvPv4khgA?yyTzf
-1-8-8 5-2-9 9-10-1
1-8-8 5-2-9 4-7-8
2x4 =
1x4 II
Scale: 1/2"=1'
1
0-1 7
0- -
5-2-9
5-1-2
9-10-1
4-7-8
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC
0.50
Vert(LL) 0.12
6-7 >947 240
MT20 244/190
TCDL 17.0
Lumber DOL
1.25
BC
0.49
Vert(CT) 0.11
6-7 ✓>999 180
BCLL 0.0
Rep Stress Incr
NO
WB
0.34
Horz(CT) -0.02
5 n/a n/a
BCDL 11,0.0
Code FBC2017/TP12014
Matrix -MS
Weight: 41 lb FT = 0%
LUMBER- I
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 5-1-6 oc bracing.
WEBS 1 2x4 SP No.3
REACTIONS. (Ib/size) 4=128/Mechanical, 5=317/Mechanical, 2=412/0-4-4
Max Horz 2=221(LC 24)
Max Uplift 4=-147(LC 8), 5=-466(LC 8), 2=-652(LC 8)
Max Grav 4=128(LC 1), 5=317(LC 1), 2=465(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-810/1019
BOT CHORD 2-7=-1086/756, 6-7=-1086/756
WEBS 1 3-7=-314/285, 3-6=-805/1157
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch left
and right ePosed; Lumber DOL=1.60 plate grip DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation about its center.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit betwieen the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
4=147,5=466,2=652.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 98 lb down and 57 lb up at
1-4-15, 98 lb down and 57 lb up at 1-4-15, 111 lb down and 99 lb up at 4-2-15, 111 lb down and 99 lb up at 4-2-15, and 146 lb
down and 174 lb up at 7-0-14, and 146 lb down and 174 lb up at 7-0-14 on top chord, and 85 lb down and 36 lb up at 1-4-15, 85 lb
down and 36 lb up at 14-15, 18 lb down and 4 lb up at 4-2-15, 18 lb down and 4 lb up at 4-2-15, and 37 lb down and 49 lb up at
7-0-14, and 37 lb down and 49 lb up at 7-0-14 on bottom chord. The design/selection of such connection device(s) is the
responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-54, 5-8=-20
Concentrated Loads (lb)
Vert: 11=113(F=57, B=57) 12=-1(F=-0, B=-0) 13=-79(F=-40, B=40) 15=-14(F=-7, B=-7) 16=61(F=-30, B=-30)
%0NS,g4�ii�i
,,�•j•O •' G • �2�i
No 39380
ON A i E?C� �.
11111
Thomas A. Albanl PE No.39380
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
® WARNING'- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSM9 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Type
Qty
Ply
J36445-Dave Golden Homes -Reed Res.
r '
]Truss
T14564098
J36445
ZHJ7B
Diagonal Hip Girder
1
1
I
Job Reference o tional
East Coast Truss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Fri Jul 13 12:34:13 2018 Page 1
ID:YE5jAwrUu64TBgdPDznGdgyyXWd-kL5ysUAQk6Ga8SgcF6Rukl?UodcZSPg2lOQEiRyyTze
-1-8-8 4-3-7 5-2-9 7-8-5 9- 0-1
1-8-8 .3 4-3-7 0-11-2 2-5-12 2-1-12
IV
3x8 = . 1x4 \\
Scale = 1:24.4
0-1 7 4-3-7
7-8-5 9-1 0-1
0- - 4-2-0
34-14 2-1-12
Plate Offsets (X,Y)— f2:0-1-8,Edgel
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.40
Vert(LL) 0.15
8-11 >609 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.46
Vert(CT) 0.14
8-11 >678 180
BCLL 10.0 '
Rep Stress Incr NO
WB 0.15
Horz(CT) -0.01
6 n/a n/a
BCDL 10.0
Code FBC2017rrPI2014
Matrix -MS
Weight: 48lb FT=0%
i
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3 `Except'
4-8: 2x8 SP DSS
REACTIONS. All bearings Mechanical except Qt=length) 8=0-10-13, 2=0-4-4.
(Ili) - Max Horz 2=221(LC 24)
Max Uplift All uplift 100 lb or less at joint(s) 5, 6 except 8=-784(LC 8), 2=-485(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 5, 6 except 8=627(LC 1),
2=342(LC 17)
FORCES. �Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-343/405
BOT CHORD 2-8=-501/321
WEBS 3-8=-392/509, 4-8=-394/274
NOTES- I
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=54ft; L=46ft; eave=6ft; Cat.
Il; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch left
exposed; Lumber DOL=1.60 plate grip DOL=1.60
11111 t 1 t t/j1,,
2) Plates checked for a plus or minus 0 degree rotation about its center.
3) This truss as been designed for a 10.0 bottom chord live load live loads.
%
,�Ow n PS A,
e
psf nonconcurrent with any other
4) • This truss has been designed for live load 20.Opsf the bottom in
��
E N 3'••'92���
a of on chord all areas where a rectangle 3-6-0 tall by 2-0-0 wide
��<`r •'�XC
'• �' F �'.
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
No 39380
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6 except at=lb)
8=784, 2=485.
'or
7) Hanger(s) other connection device(s) shall be provided sufficient to support concentrated load(s) 98 lb down and 57 lb up at
1-4-15, 98 down
r '
lb and 57 lb up at 1-4-15, 111 lb down and 99 lb up at 4-2-15, 111 lb down and 99 lb up at 4-2-15, and 146 lb
down and 174 lb up 7-0-14, 146 lb down 174 lb 7-0-14
i •,
at and and up at on top chord, and 85 lb down and 36 lb up at 1-4-15, 85 Ib
down 36 lb 1-4-15, 18 lb down
Ai : ��
i
and up at and 4 lb up at 4-2-15, 18 lb dawn and 4 lb up at 4-2-15, and 37 lb down and 66 lb up at
7-0-14, and 37 lb down and 66 lb up at 7-0-14 on bottom chord. The design/selection of such connection device(s) is the
.
��� Q.•�
responsibility of others.
Q �� ���
���s ••••� R �,•
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
`C> ,%
,�jl �\,0
js/� N AL
����tt11111111,
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Thomas A. Albans PE No.39380
Uniform Loads (psf)
MITek USA, Inc. FL Cert 6634
Vert: 1-5=-54, 6-9=-20
6904 Parke East Blvd. Tampa FL 33610
Date:
July 13,2018
A WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,1II.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with Mi rek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, m. not
a truss systeBefore use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek•
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
r f
Job
Truss
Truss Type
Qty
Ply
Golden Homes -Reed Res.
�J36445-Dave
T14564096
J36445 I
ZHJ7B
Diagonal Hip Girder
1
1
Job Reference o tional
CtlM �.0 l 1. rr. rm,—, rL 01y40 o.zzu s may zv zuiu mi i etc maustries, Inc. t-n dui � s �z:ag:�a zuia rage z
1 ID:YE5jAwrUu64TBgdPDznGdgyyXWd-CXfL4gB2VQORmbPpppy7GFYfYOyoBsvCX2AnFtyyTzd
LOAD CASE(S) Standard
Concentrated Loads (lb)
,Vert: 3=-1(F=-0, B=-0) 12=113(F=57, B=57) 13=-79(F=-40, B=40) 15=-14(F=-7, B=-7) 16=-61(F=-30, 13=-30)
®WARNING I Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111.7473 rev. 1010312015 BEFORE USE. ■■■■
Design valid for use only with MiTeM connectors. This design is based only upon parameters shown, and is for an individual building component, not e�•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing iw iTek•
is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Symbols
PLATE LOCATION AND ORIENTATION
Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
O'y1fi 1
For 4 x 2 orientation, locate
plates 0- 'lid' from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
" Plate location details available in MITek 20/20
software or upon request.
PLATE SIZE
The first dimension is the plate
4 x 4 width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
LATERAL BRACING LOCATION
E
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T or I bracing
if indicated.
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
numberwhere bearings occur.
Min size shown is for crushing only.
Industry Standards:
ANSIITP11: National Design Specification for Metal
Plate Connected Wood Truss Construction.
--DSB-89: ---Design-Standard for -Bracing.- —
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
Numbering System
6-4-8 dimensions shown in ft-in-sixteenths
(Drawings not to scale)
1 2
3
TOP CHORDS
C1-2 C2-3
o
WEBS
c3v 4
CL
U
O
' d
cs-i
cs-s
O�
BOTTOM CHORDS
8 7
6 5
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
PRODUCT CODE APPROVALS
ICC-ES Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
established by others.
© 2012 MiTek® All Rights Reserved
d�
MiTeK
MiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015
AGeneral
Failure to Follow Could Cause Property
Damage or Personal Injury
1. Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each .
joint and embed fully. Knots and wane at joint
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSI/TPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
10. Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or purlins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
- -is not.sufficient.- — - — - —
20. Design assumes manufacture in accordance with
ANSI/rPI 1 Quality Criteria.