RE: Finished floor waiver
Dear. Mr. McKuhen:
PLANNING AND DEVELOPMENT
SERVICES DEPARTMENT
Planning Division
SCANNED
BY
St Lucie County
�8�o—oaoz,
Please accept this letter in response to your written request received November 30, 2018 to waive
the finished floor elevation of 18" above the crown of the road. The waiver request is for a
proposed attached storage area to an existing single family residence at 26 Aqua Ra Dr., Jensen
Beach.
Pursuant to Section 7,04.0l(C-3) of the St. Lucie County Land Development Code, the Planning
and Development Services Director has the authority to grant administrative relief, when
topographical conditions are such that compliance with this subsection would be impracticable
or cause grade level conditions detrimental to adjacent or nearby property, consistent with the
intent of the Flood Protection regulations and any other applicable portion of this Code.
The Planning and Development Services Director has granted your request for administrative
relief of the finished floor elevation based on the following determinations:
1 The proposed finished floor elevation will be at 6' NAVD which is 1.38' above the center
line of the road and the same elevation of the existing lowest floor of the house.
2 The center line of the adjacent road is 4.62' NAVD.
3 The existing single family residence is at 6' NAVD.
4 The property is in Flood zone AE-6. Flood vents will be installed to minimize future flood
damage, as indicated on the building plans with the building permit.
5 Raising the finished floor elevation 13" above' center line of the road will cause the floor
of the storage area to be 0.12' higher than the fmished floor elevation of the house.
This approval does not in any way constitute authorization to begin construction. Prior to the
commencement of any construction on this property, an application for specific building permit
must be obtained from this department.
Please feel free to contact me at (772) 462-2822 if you have any questions.
Sincerely,
j
,Leslie Olson, AICP
Planning and Development Services Director
cc: Monica Graziani, Building and Code Compliance Manager
Carl Peterson, Building Official
Debra Zampetti, Zoning Supervisor
November 29, 2018
Leslie Olsen
St. Lucie County
Pl g and n Development Services Director
p
2300 Virginia Avenue a '"'
Ft. Pierce F134982
}
' V 3 0 201111
Re: Permit #1810-0312
cl L
Dear Leslie,
In reference to zoning review comments dated 11/28/2018, I am respectfully requesting a waiver from
the 18 inches above the crown of the road. This would reduce the finished floor elevation of this
storage area to 6.0 and I am prepared to install approved flood vents per the plans on file in your office.
i
Enclosed is a copy of the survey showing the elevation at the centerline of road.
I understand there is a $50.00 fee for an administration waiver and it may be added to the permit fees.
Thank you for your time and consideration.
Sincerely,
Eschol McKuhen
McKuhen Construction
1738 NW 8t' St
Okeechobee, Fl. 34972
FACTORS TO CONSIDER AND ILLUSTRATIONS OF SUBSTANTIAL IMPROVEMENT AND REPAIR OF SUBSTANTIAL DAMAGE 6
Table 6-1 a. Compliance Matrix;(A Zo6e' ',�
Types•
•
•o•
Rehabilitation (renovate
Compliance not required
Work shall comply and shall not be allowed to
or remodel), not SI
make the building non -compliant with any aspect
of the building that was required for compliance
Rehabilitation (renovate
Building required to comply
Work shall comply and shall not be allowed to
or remodel), SI
make the building non -compliant with any aspect
of the building that was required for compliance
(see Note below table)
Lateral addition and
Addition required to comply;
Addition required to comply; building required to
Rehabilitation, SI
building required to comply
comply (see Note below table)
LaMal ddditid& of i�
�AacJdion not required to cernply .
Add froh required to be'lelev".ate�`d,to at least the.
elevation of the existing lowest floor
Lateral addition, SI, not
Addition required to comply;
Addition required to comply
structurally connected
building not required to comply
Lateral addition, SI,
Addition required to comply;
Addition required to comply; building required to
structurally connected
building required to comply
comply (see Note below table) -
Vertical addition above
Compliance not required
Work shall comply and shall not be allowed to
building, not SI
make the building non -compliant with•any aspect
of the building that was required for compliance
Vertical addition above
Building required to comply
Work shall comply and shall not be allowed to
building, SI
make the building non -compliant with any aspect
of the building that was required for compliance
(see Note below table)
Repair foundation, not
Compliance not required
Repairs shall comply and shall not be allowed to
SI
make the building non -compliant with any aspect
of the building that was required for compliance
Repair foundation, SI.
Building required to comply
Building required to comply (see Note below
table)
Replace/extend
Building required to comply
Building required to comply (see Note below
foundation, SI (including
table)
"elevate -in -place")
Repair damage, SD
Building required to comply
Work shall comply and shall not be allowed to
make the building non -compliant with any aspect
of the building that was required for compliance
(see Note below fable)
Reconstruct new
Reconstructed building required
Reconstructed building required to comply (see
building on existing or
to comply
Note below table)
new foundation, SI
I
Note: If a map revision has resulted in a higher BFE, a post -FIRM building must comply based on the new BFE.
SI/SD DESK REFERENCE
.'
6,
FACTORS TO CONSIDER AND ILLUSTRATIONS OF SUBSTANTIAL IMPROVEMENT AND REPAIR OF SUBSTANTIAL DAMAGE
Table 6-1 b. Compliance Matrix (V Zones)
I
Typesof VVorki
Building is Po
Rehabilitation (renovate
Compliance not required
Work shall comply and shall not be allowed to
�r remodel), not SI
make the building non -compliant with any aspect
of the building that was required for compliance
Rehabilitation (renovate
Building required to comply
Work shall comply and shall not be allowed to
or remodel), SI
make the building non -compliant with any aspect
of the building that was required for compliance
(see Note below table)
Lateral addition and
Addition required to comply;
Addition required to comply, and rehabilitation
Rehabilitation, SI
building required to comply
work shall comply and shall not be allowed to
J
make the building non -compliant with any aspect
of the building that was required for compliance
(see Note below table)
;Lateral addition, not SI
Addition not required to comply
Addition required to comply
jLateml addition, SI, not
Addition required to comply;
Addition required to comply (see Note below)
structurally connected
building required to comply
(Lateral addition, Sl,
Addition required to comply;
Addition required to comply;. building required to
;structurally connected
building required to comply
comply (see Note below table)
!Vertical addition above
Compliance not required
Work shall comply and shall not be allowed to
Ibuilding, not SI
make the building non -compliant with any aspect
of the building that was required for compliance
Vertical addition above
Building required to comply
Work shall comply and shall not be allowed to
building, SI
make the building non -compliant with any aspect
of the building that was required for compliance
(see Note below table)
Repair foundation, not
Compliance not required
Repairs shall comply and shall not be allowed to
SI
make the building non -compliant with any aspect
of the building that was required for compliance
Repair foundation, SI
Building required to comply
Building required to comply (see Note below
table) -
Replace/extend
Building required to comply
Building required to comply (see Note below
foundation, SI (including
table)
"elevate -in -place")
Repair damage, SD
Building required to comply
Work shall comply and shall not be allowed to
make the building non -compliant with any aspect
of the building that was required for compliance
(see Note below table)
Reconstruct new
Reconstructed building required
Reconstructed building required to comply (see
building on existing or
to comply
Note below table)
new foundation, SI
I
jNote: If a map revision has resulted in a higher BFE, a post -FIRM building must comply based on the new BFE.
j
6.4.1 Rehabilitation and Remodeling
The NFIP considers rehabilitation and remodeling to include improvements to a building that
!do not affect the external dimensions nor expand the total area of the building. Rehabilita-
tion may or may not involve structural modification of the building. The local official must
review all work proposed for rehabilitation or remodeling to determine whether it constitutes a
16-10 SI/SD DESK REFERENCE