HomeMy WebLinkAboutPRODUCT APPROVAL - STRUCTURAL COMPONENTSr
z
,
ks
BQS Home Log In User Registration Hot Topic Submit
Surcharge Stats & Facts ; Publications Contact Us 1•,BCIS Site Map Links ; Search
a .
s ' Product Approval
c1
USER: Public User
bpr
Product Approval Menu > Product or Aoolication Search > Aoolication Us t > Application Detail
• FL #
Application Type
FL5822-R7 /�
Revision SCANNED
Code Version
2017 BY
Application Status
Approved WrLuC17�
County
Comments
Archived
NOV 2
Product Manufacturer
Smart Vent Products, Inc. 1' 401$
Address/Phone/Email
430 Andbro Dr Unit 1
Pitman, NJ 08071
(877) 441-8368
info@smartvent.com
Authorized Signature
Michael Graham
info@smartvent.com
Technical Representative
Michael Graham
Address/Phone/Email
430 Andbro Dr Unit 1
Pitman, NJ 08071
(877)441-8368
info@smartvent.com
Quality Assurance Representative
Address/Phone/Email
I
Category
Structural Components
Subcategory
Products Introduced as a Result of New Technology
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Hermes F. Norero P.E.
the Evaluation Report
Florida License
PE-73778
Quality Assurance Entity
Architectural Testing, Inc., an Intertek Company
Quality Assurance Contract Expiration Date
12/31/2020
Validated By
Locke Bowden P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
FLSS22 R7 COI Smart Vent COI SS 2017-06-18 .odf
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
1612.5(1)(1.2)
1708.2
Product Approval Method Method 2 Option B
"'Mal 11 C PV
i. At dAj
Date Submitted
08/17/2018
Date Validated
08/17/2018
Date Pending FBC Approval
08/23/2018
Date Approved
10/08/2018
Summary of Products
FL #
Model, Number or Name
Description
5822.1
SmartVent Model #1540-510
Dual Function Flood and Ventilation Vent
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5822 R7 II 1540-510 SS 2017-08-23.odf
Approved for use outside HVHZ: Yes
Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +100/-100
Evaluation Reports
Other: One vent may be used for up to 200 sq. ft. of interior
FL5822 R7 AE PERS022 SS 2018-06-20.1)df
space (minimum 2).
FL5822 R7 AE SmartVent - Imoact Requirements SS 2017-
08-23.odf
Created by Independent Third Party: Yes
5822.2
SmartVent Model *1540-511
Dual Function Flood and Ventilation Vent
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5822 R7 II 1540-511 SS 2017-02-28 odf
Approved for use outside HVHZ: Yes
Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +300/-500
Evaluation Reports
Other. One vent may be used for up to 400 sq. ft. of interior
FL5822 R7 AE PER5022 SS 2018-06-20 odf
space (minimum 2).
FL5822 R7 AE SmartVent - Imoact Requirements SS 2017-
08-23.odf
Created by Independent Third Party: Yes
5822.3
SmartVent Model #1540-520
Insulated Flood Vent
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5822 R7 II 1540-520 SS 2017-08-23 odf
Approved for use outside HVHZ: Yes
Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
Impact Resistant- N/A
Created by Independent Third Party: Yes
Design Pressure: +100/-100
Evaluation Reports
Other: One vent may be used for up to 200 sq. ft. of interior
FL5822 R7 AE PER5022 SS 2018-06-20 odf
space (minimum 2).
FL5822 R7 AE SmartVent - Imoact Reouirements SS 2017-
08-23.odf
Created by Independent Third Party: Yes
5822.4
SmartVent Model #1540-521
Insulated Flood Vent
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5822 R7 II 1540-521 SS 2017-02-28 odf
Approved for use outside HVHZ: Yes
Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +100/-500
Evaluation Reports
Other: One vent may be used for up to 400 sq. ft. of interior
FL5822 R7 AE PER5022 SS 2018-06-20 odf
space (minimum 2).
FL5822 R7 AE SmartVent - Imoact Requirements SS 2017-
08-23.odf
Created by Independent Third Party: Yes
5822.5
SmartVent Model #1540-524
16" Garage Door Flood Vent
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5822 R7 II 1540-524SS 2018-08-17 odf
Approved for use outside HVHZ: Yes
Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: One vent may be used for up to 200 sq. ft. of interior
FL5822 R7 AE PER5892 SS 2018-08-17 odf
space (minimum 2). See Installation Instructions for allowable
FL5822 R7 AE SmartVent - Imoact Requirements SS 2017-
pressures per door construction.
08-23.odf
Created by Independent Third Party: Yes
5822.6
SmartVent Model *1540-570
Wood Wall Insulated Flood Vent
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5822 R7 II 1540-570 SS 2017-02-28 odf
Approved for use outside HVHZ: Yes
Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +100/-100
Evaluation Reports
Other: One vent may be used for up to 200 sq. ft. of interior
FL5822 R7 AE PER5022 SS 2018-06-20 odf
space (minimum 2).
FL5822 R7 AE SmartVent - Imoact Requirements SS 2017-
08-23. odf
Created by Independent Third Party: Yes
5822.7 I SmartVent Model #1540-574 14.5" Garage Door Flood Vent
i rw
I
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL5822 R7 II 1540-574 SS 2018-08-17.pdf
Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other. One vent may be used for up to 200 sq. ft. of interior FL5822 R7 AE PER5892 SS 2018-08-17.pdf
space (minimum 2). See Installation Instructions for allowable FL5822 R7 AE SmartVent - Impact Requirements SS 2017-
pressures per door construction. 08-23.pdf
Created by Independent Third Party: Yes
I
Bads Next
Contact Us :: 2601 Blair Stone Road. Tallahassee 1 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Departrnent with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick here .
Product Approval Accepts:
Credit Card
Safe
8 3/4'
R/O
Digitally signed by Hermes F. Norero, P.E.Reason: I am approving thi
Date: 2017.02.2818:53:56s 5'00'ment %%``�eS F
DETAIL DIAGRAM — �� •'•••• •• ' 'jor
— — — — - — — — -- —MODEL 1540-570 — — -- — — ` ••" •' ��i
14r WOOD WAM WSMIED + C)
+
7
F6k
%ONTT FLOAT SLOT
V-2 1/2"
• ROUGH OPENING DIAGRAM
DESIGNED TO FIT BETWEEN 2 BI WOOD STUDS
SMART VENT FOUNDATION FLOOD VENTS
430 ANDBRO DR., UNIT 1
SMART VENT®
PITMAN NJ 08071
877-441-8368
14.5" WOOD WALL INSULATED
WWW.SMARTVENT.COM
MODEL 1540-570
SIZE
DWO N0.
REV
I 1540-570
DATE 6-21-16 SHEET 1 OF 2
INSTALLATION E NLs UCTIONS
��S F.
MODEL-1540-570-
S mart t7E N T 14.5" WOOD WALL INSULATED
••'�O i
REV. 6-21-16-
877— 441— 8368
7
PZ
•'�.�•
www.smart�vent.com
P.
D Np. .. s
A I LICTBACIONS
--,,,s,ONAt-
(SET71
DIAGRAM PAGE 1 OF 2
111
1. FOR EACH VENT CUT A CLEAN, SQUARE, AND LEVEL 14 1/2"X 8 3/4" OPENING IN THE OUTSIDE SHEATHING. ENSURE THAT THE BOTTOM OF THE OPENING
IS NO MORE THAN 12" ABOVE THE OUTSIDE FINAL GRADE.
2. REMOVE VENT DOOR FROM VENT FRAME. (TURN UPSIDE DOWN, ROTATE BOTTOM OF DOOR OUTWARD AND SLIDE OUT OF FRAME SLOTS)
3. POSITION THE VENT FRAME IN THE OPENING WITH SERIAL NUMBER LABEL ON THE BOTTOM AND ENSURE THAT IT IS SQUARE AND LEVEL.
APPLY A SMALL
BEAD OF HURRIBOND GRIP & SEAL OR EQUIVALENT ADHESIVE BEHIND THE VENT FRONT FRAME AS SHOWN IN THE DIAGRAM.
4. USE 4 EACH FLATHEAD STAINLESS STEEL SCREWS TO SECURE THE FRAME THROUGH THE SHEATHING AND INTO THE STRUCTURAL MEMBER.
NOTE: THIS MODEL DOES NOT CONTAIN. STRAPS.
5. INSTALL THE DOOR BY INSERTING THE SIDE PINS INTO THE TRACKS AT THE SIDES OF THE VENT FRAME. ENSURE THE BLACK FLOAT PINS ARE FACING DOWNWARD.
6. LET THE BOTTOM OF THE VENT DOOR GO SO THAT IT ROTATES DOWN INTO THE VENT FRAME. CHECK THAT VENT DOOR IS LATCHED ON BOTH SIDES.
7. TO OPEN THE DOOR INSERT 2 CREDIT CARDS INTO THE FLOAT SLOTS AS SHOWN IN THE DIAGRAM.
8. THE OUTSIDE FLANGE AND SCREWS CAN, BE COVERED WITH "J" CHANNEL OR ANY SURFACE TREATMENT LIKE BRICK OR STONE. USE CAUTION DO NOT APPLY
ANY COVERING THAT WILL IMPEDE THE MOVEMENT OF THE VENT DOOR IN ANY DIRECTION.
DETAIL SPECIFICATIONS:
MATERIAL: STAINLESS STEEL
OPERATION: AUTOMATIC NON -POWERED ACTIVATION AND OPERATION
VENT REMAINS CLOSED AND LOCKED UNTIL ACTIVATED
INSTALLATION:
SECURED W/ 4 STAINLESS STEEL FLATHEAD SCREWS
NOTE: THIS MODEL DOES NOT CONTAIN STRAPS
HYDROSTATIC RELIEF: 200 SQ. FT PER VENT
REQUIREMENTS: MINIMUM OF 2 VENTS PER ENCLOSED AREA
MOUNTED ON OPPOSITE OR ADJACENT WALLS
COLORS: STAINLESS STEEL (STANDARD)
WHITE, WHEAT, GRAY, AND BLACK (AVAILABLE)
MEETS THE REQUIREMENTS FOR ENGINEERED OPENINGS AS SET FORTH BY:
FEMA, NFIP, ICC, & ASCE
SUPPORTIVE DOCUMENTS, TB 1-08, 44CFR 60.3(C)(5), ASCE 24-14
ICC EVALUATION # ESR-2074
SHEET 2 OF 2