Loading...
HomeMy WebLinkAboutCERTIFICATE OF TERMITE TREATMENTr , JOB ADDRESS: BUILDER/CONTRACTOR: e `G Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave Fort Pierce, FL 34982 772-462-2172 Fax 772-462-6443 RTIFICATE OF TERMITE TREATMENT SCANNet) CONSTRUCTION SOIL TREATMENT UY St u '' Counfy FAA eeOt j eI® Ave �D� ri V C_ e �te� 3YS e(S PEST CONTROL CONTRACTOR: E CT -A -BUG TERMITE & PEST CONTROL INC. PEST CONTROL LICENSE #: J13175775 We, the undersigned, hereby certify that we have pretreated the above described construction for subte `ranean termites in accordance with the standards of the National Pest Control Association. Square feet if area treated: '52 Percentage of solution: .05% Date of Treatment: ?s Footing 1st Treatment Re -Treat Driveway 1st Treatment Re -Treat Other 1st Treatment Re -Treat Chemicals used: DOMINION 2L Total gallons used: __O� 2 Time of Treatment: 2,100 .f Slab 1st Treatment Re -Treat Pools 1st Treatment Re -Treat Perirt�r Final Inspection of Exterminator ' Date Note. There must be a completed form for each requir d treatment or re -treatment and this form must be on the job site tol be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re -inspection fee charged. FBC104.2.6 Certificate of Protective Treatment for prevention of termites A weather resistant jobsite posting board shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit files. The Treatment Certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area treated, chemical used, percent concentration and number of gallons used, to establish a verifiable record of protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval, St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listing all the treatments and dates of applications. Revised ,7/24/2014 I I RECEIVED NOV 13 7010 Permitting Departcme St. Lucie Cotlryr Soil Nuclear Gauge Client: Report Date: 11/9/2018 The Garcia Family yFa Test Method: ASTM D 6938 990 Emerald Avenue �r�a PaABL Wcb Fort Pierce, FL 34945 FBPE CAN 4930 60r NW Corienod4y Cove Pod St Ludo, FL3498e 10610 - 0311 Project: 18-0182.00 990 Emerald Ave Fort Pierce, FL Test Results Test # RetAlTost O6ProctorMethod Soil Classification Optimum Moisture %) Maximum DryDensity (pcf) In Place Moisture %) In Place Dry Density (o Probe Depth In Percent Com action MIn1Max Comp. %) Remark 1! WA 11.1 112.3 9.4 110.1 12 98 95/105 Pass 2 NIA 11.1 112.3 9.3 110.2 12 98 95/105 Pass 3 WA 11.1 112.3 9.2 110.2 12 98 951105 Pass Test Information Test # Test Location Elevation Reference Gauge Make I Model / SN / Calibrated Field Techniclan 1 Below Slab Grade: Patio, NW comer 0-1 Troxler 13430 / 24566 / 1PEa ssss(On, Thomas 2 Below Slab Grade: Patio, SE on pad 0.1 Troxler 13430 / 24566 / Preon, Thomas 3 Below Slab Grade: Patio, Center of pad 0-1 Troxler 13430 / 24565 / Pressor, Thomas Remarks Comments Pass: Tests results comply with specifications Tests are'Dired Transmission' (Method A) unless probe depth to noted as 'Backscatter. Gauge calibration data on file with the testing agency. 1, 2, 3:1-2 HCP=40+, > 95 % Compaction, PASS. HCP tests are empirically correlated to the relative density of the soil. \`1ti111t II//y' �0HN KF/y ..•••• 0 ENSF ' j,:;;1No 632)8 1.1102018 r.3ot,�1 ke , P.E. ' [V PFo ion I er.# jP8 StatO� tide• p �\�� Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Page 1 of 1 Digitally, signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.