HomeMy WebLinkAboutCERTIFICATE OF TERMITE TREATMENTr , JOB ADDRESS:
BUILDER/CONTRACTOR: e `G
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave
Fort Pierce, FL 34982
772-462-2172 Fax 772-462-6443
RTIFICATE OF TERMITE TREATMENT SCANNet)
CONSTRUCTION SOIL TREATMENT UY
St u '' Counfy
FAA eeOt j eI® Ave �D� ri V C_ e
�te� 3YS e(S
PEST CONTROL CONTRACTOR: E CT -A -BUG TERMITE & PEST CONTROL INC.
PEST CONTROL LICENSE #: J13175775
We, the undersigned, hereby certify that we have pretreated the above described construction for
subte `ranean termites in accordance with the standards of the National Pest Control Association.
Square feet if area treated: '52
Percentage of solution: .05%
Date of Treatment:
?s Footing
1st Treatment
Re -Treat
Driveway
1st Treatment
Re -Treat
Other
1st Treatment
Re -Treat
Chemicals used: DOMINION 2L
Total gallons used: __O� 2
Time of Treatment: 2,100
.f Slab
1st Treatment
Re -Treat
Pools
1st Treatment
Re -Treat
Perirt�r Final Inspection
of Exterminator ' Date
Note. There must be a completed form for each requir d treatment or re -treatment and this form must be on the job
site tol be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re -inspection
fee charged.
FBC104.2.6 Certificate of Protective Treatment for prevention of termites A weather resistant jobsite posting board
shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed,
providing a copy for the person the permit is issued to and another copy for the building permit files. The Treatment
Certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area
treated, chemical used, percent concentration and number of gallons used, to establish a verifiable record of
protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall
be completed prior to final building approval,
St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on
the electrical panel box cover, listing all the treatments and dates of applications.
Revised ,7/24/2014
I
I
RECEIVED
NOV 13 7010
Permitting Departcme
St. Lucie Cotlryr
Soil Nuclear Gauge
Client:
Report Date: 11/9/2018
The Garcia Family
yFa
Test Method: ASTM D 6938
990 Emerald Avenue
�r�a
PaABL Wcb
Fort Pierce, FL 34945
FBPE CAN 4930
60r NW Corienod4y Cove
Pod St Ludo, FL3498e
10610 - 0311
Project:
18-0182.00
990 Emerald Ave
Fort Pierce, FL
Test Results
Test #
RetAlTost
O6ProctorMethod
Soil
Classification
Optimum
Moisture
%)
Maximum
DryDensity
(pcf)
In Place
Moisture
%)
In Place
Dry Density
(o
Probe
Depth
In
Percent
Com action
MIn1Max
Comp.
%)
Remark
1!
WA
11.1
112.3
9.4
110.1
12
98
95/105
Pass
2
NIA
11.1
112.3
9.3
110.2
12
98
95/105
Pass
3
WA
11.1
112.3
9.2
110.2
12
98
951105
Pass
Test Information
Test #
Test Location
Elevation
Reference
Gauge
Make I Model / SN / Calibrated
Field Techniclan
1
Below Slab Grade: Patio, NW comer
0-1
Troxler 13430 / 24566 /
1PEa
ssss(On, Thomas
2
Below Slab Grade: Patio, SE on pad
0.1
Troxler 13430 / 24566 /
Preon, Thomas
3
Below Slab Grade: Patio, Center of pad
0-1
Troxler 13430 / 24565 /
Pressor, Thomas
Remarks
Comments
Pass: Tests results comply with specifications
Tests are'Dired Transmission' (Method A) unless probe depth to noted as
'Backscatter. Gauge calibration data on file with the testing agency.
1, 2, 3:1-2 HCP=40+, > 95 % Compaction, PASS. HCP tests are
empirically correlated to the relative density of the soil.
\`1ti111t II//y'
�0HN KF/y
..••••
0 ENSF '
j,:;;1No 632)8
1.1102018
r.3ot,�1 ke , P.E. ' [V
PFo ion I er.# jP8
StatO� tide• p �\��
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Page 1 of 1
Digitally, signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.