HomeMy WebLinkAboutGENERAC - AIR COLLED GAS ENGINENCLU ES: • True Power" Electrical Technology • Two Line LCD Multilingual Digital Evolutions" Controller (English/Spanish/ French/Portuguese) . • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 5 for Details. - Electronic Governor • Standard Wi-Fls" Remote Monitoring sSystem Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure •I Flexible Fuel Line Connector • Direct To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 5 Year Limited Warranty • Listed and Labeled by the Southwest Research Institute allowing installation as close as 18' (457 mm) to a structure.* *Must be located away from doors, windows, and fresh air Intakes and in accordance with local codes, hitps-Ilassets.swrl orglllbraryIDfrectoyofLjsfedPtoducls/ Construation/ndustryt973 DoC 204 13204-01-ol Revg pdt DCO - -- - .-..R.%. O INNOVATIVE ENGINE DESIGN & RIGOhOUS TESTING are at the heart of Gene success in providing the most reliable generators possible, Generac's G-Force engine lineup offers added peace of mind and reliability for when you need it the most. The 0-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O 'RI U£ POWER" ELECTRICAL TECHNOLOGY: Superior harmonics and sloe wave O form produce less Ihan 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, suih as variable speed HVAC systems. D TEST CRITERIA: 1r PROTOTYPE TESTED 0 I. M OTn MG122 EVALUATION SYSTEM TORSIONAL TESTED MOTOR ST GUARDIAN® SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating Models G007036-1, G007037-1 (Aluminum - Bisque) -16 kW 60 Hz Model G007035-1 (Aluminum - Bisque) -16 kW 60 Hz Models G007039-1, G007038-1 (Aluminum - Bisque) - 20 kW 60 Hz Models G007043-2, G007042-2 (Aluminum - Bisque) - 22 kW 60 91CANNED _. BY CVUS Q LiSTED UJ . u �. 1(mlted cf cult slvAtchss-Unlapplies s pacekaged v to lfi the 9mari Stvlchiare Ull Cerlfied In the USA only. SOLID-STATE, FREOUE0ICY COPAPENSAIED VOLTAGE REGULATION: This state-of-fhe-art power maximizing regulation system is at an all General; models. It provides Optimized FAST RESPONSE to Changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY in electronically torque -matching the surge loads to the engine. Digital by voltage regulation at ±1�. networSINGLk SOURCE SERVICE RESPONSE from Gsnerac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. GENERAL TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this ARTINGABILiTY confidence is that the GENERAC product Ilne Includes its own transfer O MOtI1LE LINIt�" REfviOTE MONiTOBING: FREE with every Guardian Series Home systems and controls for total system line standby generator. Allows you to monllor the status ofyour generator = world using a smartphone, tablet, or PC. Easily access Information such as the current from anywhere in the operating status and maintenance alerts. Connect your account to your authorized service '— IGENERA C PROMISE dealer' for fast, fdendlyandproactive service. With Mobile Link, e«•.� °q" than eI power outage. , You are taken care of before bmaa„ob w,:,,b County 16/20/22 kW features and benefits 4 Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing all consumption resulting in longer engine life. ® "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. 0 Elee+ctronic Ignition/spark advance These features combine to assure smooth, quick starting every time. 0 Frl11 pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval. ® Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil, ® High temperature shutdown Prevents damage due to overheating. -_.-.- .._I.�c. Asa.'.—�^._n-^-•----�.-.�r.-^..r.:-_...,..^_.,-,+�.T.a�•r.:-w.�c.T�Wr...,,-r�r...-•axr��:e :era.--^ ,._='--r,nr..n ...._ - ... _. r. ... .. . .ors-'... �a.�,_..._.'.�. ._..�_o..,«,.. _.r. ...�.._... ® Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. 40 Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. ® Displaced phase excitation Maximizes motor starting capability, ® Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes. 0 UL 2200 listed For your safety, I =-•-�.� `•:��..r.��-ecs��--�;.s_ ..r-.r. •". S Hf:'+ $1,7VArt? yi �•-s�rsc� s.- �.-a^•.-r-.�--trcr�, —�- e- �--•-r, -r s^ r r ® Fully automatic Transfers your vital electrical loads to the energized source of power. ® NEMA 3R Can be Installed Inside or outside for maximum flexibility. ® Rem Iote mounting I Mounts near your existing distribution panel for simple, low-cost installation. Eirk'ijM13i�S-.,°�:a: * Auto/Manual/Off Illuminated buttons Selects the operating made and provides easy, at -a -glance status Indication In any condition, ® Two-'Ine LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. 8 Sealed, raised buttons Smooth, weather -resistant user Interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. e Generator voltage sensing ® Utility interrupt delay Constantly monitors generator voltage to ensure the cleanest power delivered to the home. Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. ® Engine warm-up Engine cool -dawn Ensures engine is ready to assume the load, setpoint approximately 5 seconds. Allows engine to cool prior to shutdown, setpoint approximately 1 minute. to Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. ® Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. of Main line breaker Compatible with lead acid and AGM-slyle batteries. circuit Protects generator from overload. Electronic governor Maintains constant 60 Hz frequency. �Ay�+:� .�_�.. . u .:.`r_=Si.---..�.1.__vr�Tn+�E....,'+-�.:i;-'T-.. ..�:'t:3�f.Fen-..z--.�?�^ia'1..-,..:n•xS-.-,. ® SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key looking roof panel for security. Lfit-out front for easy access Wall routine maintenance items. Electrostat- Ically applied textured epoxy paint for added durability. ® Enclosed critical grade muffler Quiet, critical grade muffler Is mounted inside the unit to prevent injuries. * Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building. �tJtic=�l�•s i:r;;s�. 21yG-t0-jin 0 1 it (805 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. 0 Direct -to Idirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. 0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. 16/20/22 kW Model Rated Maximum Continuous Power Capacity (LP) Rated Maximum Continuous Power Capacity (NG) Rated Voltage Rated Maximum Continuous Load Current-240 Volts (LP/NG) Total Harmonic Distortion Main Line Circuit Breaker PHass Number of Rotor Poles Rated AC Frequency Power Factor Battery Requirement (not included) Unit Weight (Ibft) Dimensions (L'x Wx H)1Nmm Sound output in de(A) at 23 R (7 m) Will generator operating at normal load" Sound output In dB(A) at 23 it (7 m) with generator in Ouiel Test" low -speed exercise mode'" IGIENERAC specifications 0097035-0,G007036-0, 0007038-0,0007039.0 G00704 -1,G0 70434 6007037.0 (16 kW) (20 kW) 16,000 Walls' 20,000 Wens' 22,000 16,000 Watts` 18,000 Watts` 19,500 240 240 240 66.6/66.6 83.3R5 91,6/81,3 Less than 5% Less than 5% Less than 5% 70 Amp 100 Amp 100 Amp 1 1 1 2 2 2 60 Hz 60 Hz 60Hz 1.0 1.0 1.0 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 550 CCA Minimum 4061186 4481203 466/211 48 x 25 x 29/1218 x 638 x 732 66 66 67 58 58 58 vu��Taa Type o1 Engine GENERAC G-Force 1000 Series Number of [Worlers 2 2 2 Displacement 999 cc 999 cc 999 cc Cylinder Block Aluminum w/ Cast Iron Sleeve Vale Arrangement Overhead Valve Overhead Valve Overhead Valve IgnBlodSystem Solid -stale w/ Magneto Solid-state W/Magneto Solid-state w/Magneto Gov emorSystem Electronic Electronic Electronic compression Ratio 9.5:1 9.5:1 9.5.1 Starter 12 Vdc 12 Vile 12 Vdc Oil Capacity ihcluding Filler Approx, 1.9 gV1.8 L Approx.1.9 gV1.8 L Approx,1.9 gV1,8 L Operating rpm 3,600 3,600 3,600 Fuel Consumption Natural Gas 93/hr (m3/hr) 1/2 Load 218 (6.17) 204 (5.78) 228 (6.46) Full Load 309 (8,75) 301 (8.52) 327 (9.26) Liquid Propane 113/hr (gal/hr) [Uhr) 1/2 Load 91.6 (2,52)19.53] 86 (2.37) [8.99] 92 (2,53) [9.57] Full Load 106.8 (2,94) [11.11] 129.6 (3,55) 113A81 142 (8,90) (14.77] Nolel Fuel pipe must be sized for full load, Required fuel pressure to generator fuel Inlet alai] load ranges-3.5-71 water column (7-13 mm mercury) for natural gas, 1012,water column (19-22 mm mercury) for LP gas. For Btu content, multiplylts/hrx2500 LP or9sPorx100-0ING.For Mega(Dula _content, rmulUplrm'/hrx9M5(LP),grrm3/brx37.26 2-Line Plain Text Mullllingual LCO Display Simple user Interface for ease of operation, Mode, Bullons:Aulo Automatic Start on Ulilily feliure, 7 day exerciser. Manul Start with starter control, unit slays on. If utility falls, transfer to load takes place, o0 Slops unit. Power is removed. Control and charger still operate, Read to Run/Maintenance Messages Standard Engine Run'Hours indication Standard Programmable stair delay between 2-15oo seconds SlandaN (programmable by dealer only) Utility Vdliage LoswRolum to Utility Adjustable (Brownout Setting) From 140-171 V/190-216 V FulureiSet Capable Fxerclser/Exercfse Set Error Warning Standard RunfAlarm/Vidnienance Logs 50 Events Each Engine sbi l Sequence Cyclic cranking:16 sec on, 7 rest (90 sec maximum duration), Stager Lgck-out Slader cannot re-engage until 5 sec after engine has slopped, Smart Battery Charger Standard Charged Faull/Missing AC Warning Standard Low Baltery/Battery Problem Protection and Battery Condition Indication Standard Aulomelic Voltage. Regulkan with Over and Under Voltage Protection standard Under-Frequency/Overloadjslepper Overcuirenl Protection Standard SafetyFusffd/Fpse Problem Protection Automatic Low 011 Pressure/High 011 Temperature Shutdown Standard Ovgtcrailk/Overspeed (Q 72 Hz)/rpm Sense Loss Shutdown Standard Standard High En, . Temperature Shutdown Standard Internal Faullnncorrect Wiring Protection Common Extemal Fault Capability Standard Field Upgradable Prinware Standard Standard "Sound lovelsaretaken tram the want orlhe g6eneralon Sound levels taken Irani aNersldes of lha Qeneralar may be higher depending on lnelallallml pammelals, fWifig daanlllonv-Sfanaby: Appllenbfa for supplying omorgencypovrerior0e duraeon al the lailWaaromage.NoovailoadcapabllilyIsavallablefor this ratIng.(MratingsInaccordancewi(he55514,ISo3o4sand 0IN6271), IMagmumklruvoltampsandaurentaresub)ecttoandrimilodhysuehfaclarsasfuelBlulmeeajoule confam,ambleni lempamhae,allfludo, enginepowarsnd eondinan, etc. Mal)nnrm powerdscmasesabau13bpercent foreach 1,00e1eal 1384,8 motors) abavesea levelmndalsoYdll decleaseabouf 1 perdenf fofeaah 6°C (to °a above 1610 (691F), i