HomeMy WebLinkAboutSOIL NUCLEAR GAUGE=j%7Soil. Nuclear. Gauge.client: Project Report Date: 10/30/2018 Renar Development Corp... 1:13-15-66-5434B�&Associates,,.l`nc, •
Test Method: ASTM D 6938 3725 S: East Oceari Boulevard; Suite 101 ' Momingside Residential Lots... B
Port St. Lucie Branch: ' Stuart, FL 34996...Fort: Pierce t Lucie County:::.
Florida CA No. 5950 ...
460 NW Concourse Place, UnR 1
... ... Fort: Pier
ce, FL :... .
Port'St. Lucie, FL 34986
LE.QP1�
Phone: 772-878-0072
Test Results:
.....
Test #
Retest
Of
Test
• . Date
Proctor ID..:
Method .:
Soil
Classification
imum
Moisture' e "
(%)- , : -
Maximum
: Dry Density'
(pcf) :.
In Place
Moisture
(%) : - -
In:Place
Dry Density
(paf)
Probe
Depth:
(In)
Percent
Compaction
q
Min Comp.
(%)
Remark
52
10/25/18
18-194
A
--
114
112.5
6.2
110.1
12
98:
95
.
Pass
53 .
:
10/25/18
: 18-194 :
A :
: --
11.5
: 112.5
4:6 . :
11:1.9'
.12 :
99 • :
95
Pass .
54
...
10/25/18_
18-194..
. ' ...A ....
... --..
1.1.5
_ ..112.5 `
.....5.2
.110.0` ...
... 12
� 98 ...
.. � 95......
.... Pass ..
55
10/25/.18
18-194
A
--
.11.5
112.5
4.5
110.5
12
98 -.
95 "
Pass
56
10/25/18
18A94:
A
--
11:5
112.5
5.7
111.2
12
99
95 ""
Pass
:Test
Information
-
Test #
52
Test Location
Building = Slab on Grade: Permit# 1809-0120. Southeast Comer of House Pad in Lot
96 on Palm Breezes Drive ......
Elevation
-1.0
Reference
Top of House Pad
Gauge
Make / Model / SN / Calibrated
Troxler 17-3430 / 21330 /
Field Technician
Tech, Port St: Lucie
53
Building - Slab on Grade: Permit# 1809-0120. Southwest Corner of: House Pad' in Lot
96 on Palm Breezes Drive
:-1.0
"
Top of House Pad:
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
54
Building - Slab. on Grade: Permit# 1809-0120. Center of.House Pad in Lot.96 on Palm
Breezes Drive
-1.0:,
Top of. House Pad .::.
Troxler / T-3430 / 21330 / ..:.
Tech, Port St. Lucia.:.
55
Building - Slab; on Grade: Permit# 1809-0120.-Northwest Corner of House: Pad in Lot
96 on Palm Breezes Drive
-1.0
Top of House Pad
Troxler / T-3430 /,21330 / ::
Tech; Port St. Lucie:
56
Building -Slab on Grade: Permit# 1609-0120. Northeast Comer of House Pali in Lot
96 on Palm Breezes Drive. "
-1.0
Top of House Pad:
Troxler / T-3430 / 21330 /
Tech, Port S4. Lucie
Remarks , Comments:
Pass:: Density Pass Tests are "Direct Transmission (Method A) unless probe depth: is noted as: "'''• "
. . . .... .. "Backscatter'. Gauge.calibration data on file with the.testing agency...
l�d
.p`..i
R
.ecFO
OOT
g
Sjttiry9
' `.,
O
t. (Uc ePart,
�e
(' tii�'
o;
c , .
°Vnh,ent
AS A MUTUAL PROTECTION TO OUR CLIENT, THE I?UBLICAND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE; CONFIDENTIAL PROPERTY OF
Page1 of 1
THE CLIENT, AND AUTHORIZATION: FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED
PENDING OUR WRITTEN APPROVAL.
761-..