Loading...
HomeMy WebLinkAboutSOIL NUCLEAR GAUGE=j%7Soil. Nuclear. Gauge.client: Project Report Date: 10/30/2018 Renar Development Corp... 1:13-15-66-5434B�&Associates,,.l`nc, • Test Method: ASTM D 6938 3725 S: East Oceari Boulevard; Suite 101 ' Momingside Residential Lots... B Port St. Lucie Branch: ' Stuart, FL 34996...Fort: Pierce t Lucie County:::. Florida CA No. 5950 ... 460 NW Concourse Place, UnR 1 ... ... Fort: Pier ce, FL :... . Port'St. Lucie, FL 34986 LE.QP1� Phone: 772-878-0072 Test Results: ..... Test # Retest Of Test • . Date Proctor ID..: Method .: Soil Classification imum Moisture' e " (%)- , : - Maximum : Dry Density' (pcf) :. In Place Moisture (%) : - - In:Place Dry Density (paf) Probe Depth: (In) Percent Compaction q Min Comp. (%) Remark 52 10/25/18 18-194 A -- 114 112.5 6.2 110.1 12 98: 95 . Pass 53 . : 10/25/18 : 18-194 : A : : -- 11.5 : 112.5 4:6 . : 11:1.9' .12 : 99 • : 95 Pass . 54 ... 10/25/18_ 18-194.. . ' ...A .... ... --.. 1.1.5 _ ..112.5 ` .....5.2 .110.0` ... ... 12 � 98 ... .. � 95...... .... Pass .. 55 10/25/.18 18-194 A -- .11.5 112.5 4.5 110.5 12 98 -. 95 " Pass 56 10/25/18 18A94: A -- 11:5 112.5 5.7 111.2 12 99 95 "" Pass :Test Information - Test # 52 Test Location Building = Slab on Grade: Permit# 1809-0120. Southeast Comer of House Pad in Lot 96 on Palm Breezes Drive ...... Elevation -1.0 Reference Top of House Pad Gauge Make / Model / SN / Calibrated Troxler 17-3430 / 21330 / Field Technician Tech, Port St: Lucie 53 Building - Slab on Grade: Permit# 1809-0120. Southwest Corner of: House Pad' in Lot 96 on Palm Breezes Drive :-1.0 " Top of House Pad: Troxler / T-3430 / 21330 / Tech, Port St. Lucie 54 Building - Slab. on Grade: Permit# 1809-0120. Center of.House Pad in Lot.96 on Palm Breezes Drive -1.0:, Top of. House Pad .::. Troxler / T-3430 / 21330 / ..:. Tech, Port St. Lucia.:. 55 Building - Slab; on Grade: Permit# 1809-0120.-Northwest Corner of House: Pad in Lot 96 on Palm Breezes Drive -1.0 Top of House Pad Troxler / T-3430 /,21330 / :: Tech; Port St. Lucie: 56 Building -Slab on Grade: Permit# 1609-0120. Northeast Comer of House Pali in Lot 96 on Palm Breezes Drive. " -1.0 Top of House Pad: Troxler / T-3430 / 21330 / Tech, Port S4. Lucie Remarks , Comments: Pass:: Density Pass Tests are "Direct Transmission (Method A) unless probe depth: is noted as: "'''• " . . . .... .. "Backscatter'. Gauge.calibration data on file with the.testing agency... l�d .p`..i R .ecFO OOT g Sjttiry9 ' `., O t. (Uc ePart, �e (' tii�' o; c , . °Vnh,ent AS A MUTUAL PROTECTION TO OUR CLIENT, THE I?UBLICAND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE; CONFIDENTIAL PROPERTY OF Page1 of 1 THE CLIENT, AND AUTHORIZATION: FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL. 761-..