HomeMy WebLinkAboutSOIL NUCLEAR GAUGEArdamanSoil Nuclear Gauge
,Ass 'datesjnc. _ rmst?# o�1zs
1lUp
rt Date: 3/15/2019
— --Port St. Lucie-eranoh Test -Method: ASTM-D-6938
Florida CA No. 5950
460 NW Concourse Place, Unit 1
Port St. Lucie, FL 34986
Phone:772-878-0072
RECEIVED
Client: Project: MAR X 9
Renar Development Corp. 113-15-66-5434B kST.cie Count 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential L y, Permitting_
Stuart, —FL 34896 Fort Pierce
Fort Pierce, FL
" Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
(%)
Maximum
Dry Density
(pcf)
In Place
Moisture .
N
In Place
Dry Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min Comp.
(%)
Remark
128
3/7/19
19-045
A
-
11.0
116.5
7.8
114.2
12
98
98
Pass.
Test Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN / Calibrated
Field Technician
128
Building - Slab on Grade: House Pad for Lot 2 on Silver Sands Lane. Center
-1.0
Top of Pad
CPN / MC-3 / M3309 07151 //
Tech, Port St. Lucie
Remarks
Comments
Pass: Density Pass
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
SQ4NAV �
4c/�y
®unto
ARDAMAN & ASSOCIATES, INC.
FL. Certificat&,of icgAthorization No. 5950
Mark Zrallack,.°r,.E. ,
Construction Services Manager
FJ�onda Licens6. l '86546
ii ,
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN(
OUR WRITTEN APPROVAL.