Loading...
HomeMy WebLinkAboutD O H SEWAGE TREATMENT DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATIONSSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATION APPLICATION # AP1361173. PERMIT # 56-SF-1872411 DOCUMENT # SE1091986 APPLICANT: James Jenkins CONTRACTOR /! AGENT: Classic Const. of South Fla. Inc ' ttuc° LOT: 17 1 BLOCK: 62 SUBDIVISION: Lakewood Park ID#: 1301-606-0099-000-7 TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE I REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: EX ]YES [ ]NO NET USABLE AREA AVAILABLE: 0.27 ACRES TOTAL ESTIMATED SEWAGE FLOW: 300 GALLONS PER DAY [ RESIDENCES -TABLET / OTHER -TABLE 2 ] AUTHORIZED SEWAGE FLOW: 404.99 GALLONS PER DAY [ 3.500 GPD/ACRE I OR 2500 GPD/ACRE ] UNOBSTRUCTEDIAREA AVAILABLE: 750.00 SQFT UNOBSTRUCTED AREA REQUIRED: 750.00 SQFT BENCHMARK/REFERENCE POINT LOCATION: site BM Nail in S Side of rd. NW lot Corner ELEVATION OF,PROPOSED SYSTEM SITE 2.00 [ INCHES / FT ] [ ABOVE / BELOW ] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK. WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: FT DITCHES/SWALES: 15 FT NORMALLY WET: [ ]YES [X]NO WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: 75 FT NON -POTABLE: FT BUILDING FOUNDATIONS: 5 FT PROPERTY LINES: 5 FT POTABLE WATER LINES: 50 FT SITE SUBJECT ITO FREQUENT FLOODING? [ ]YES [X]NO 10 YEAR FLOODING? [ ]YES [X]NO] 10 YEAR FLOOD ELEVATION FOR SITE: FT [ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD SOIL PROFILE INFORMATION SITE 1 SOIL PROFILE INFORMATION SITE 2 I USDA SOIL SERIES:Pepper sand Munsell #/Col,or Texture Depth 10YR 5/1 Sand 0 To 6 1 OYR 4/1 Sand 6 To 13 1 OYR 5/1 Sand 13 To 36 1 OYR 6/1 Sand 22 To 36 10YR 4/3 Fine Sand 36 To 43 1 OYR 3/4 j Fine Sand 43 To 59 HOLE CAVING Refusal 59 To 72 I USDA SOIL SERIES:Pepper sand Munsell #/Color Texture Depth 10YR 3/3 Sand 0 To 5 1 OYR 4/1 Sand 5 To 17 1 OYR 5/1 Sand 17 To 38 1 OYR 6/1 Sand 27 To 41 1 OYR 4/3 Fine Sand 41 To 60 HOLE CAVING Refusal 60 To 72 OBSERVED WATERITABLE: 39.00 INCHES [ ABOVE / SELOW ] EXISTING GRADE TYPE: [ PERCHED / APPARENT ] ESTIMATED WET SEASON WATER TABLE ELEVATION: 23 INCHES [ ABOVE / BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: [ ]YES [X]NO MOTTLING: [X]YES [ ]NO DEPTH: 23.00 INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Sand/0.60 DEPTH OF EXCAVATION: INCHES DRAINFIELD CONFIGURATION: [ ] TRENCH [XI BED [ ] OTHER (SPECIFY) r" REMARKS/ADDITIONAL CRITERIA VSWT determined using USDA WSS and soil borings. OYR6/1 stripping in 10YR5/1 matrix >10% starting at 23" in SB7. B1 2" below BM. SB2 2" above BM. I SITE EVALUATED BY: I Ingram, Brian (T e: Environmental Specialist II) (ENVIRONMENTAL HEALTH) DH 4015, 08/09 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC I DATE: , 08/28/2018 Page 3 of 4 AP1361173 EID1872411 " I n i