HomeMy WebLinkAboutENERGY EFFICIENCY CODEi i FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Nalme: Lot 17 - James Jenkins Residence Builder Name: Classic Construction of South Florida Inc Street: Fort Walton Avenue Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Owner: I Permit Number: Jurisdiction: 661000 A' Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2) 1. New construction or existing New (From Plans) 9. Wall Types (1476.0 sqft.) Insulation 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 1287.00"� 3. Number of if family 1 b. Frame - Wood, Adjacent R=11.0 189.00 ft' units, multiple c. NIA R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1315.0 sqft.) Insulation Area 5. Is this a worst case? No 6. Conditioned floor area above grade (1`12) 1315 a. Under Attic (Vented) b. N/A R=30.0 1315.00 ft2 R= ft2 Condition) d floor area below grade (ft2) 0 c. N/A 11. Ducts R= ft2 R ft2 7. Windows(170.9 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 263 a. U-Factor. Dbl, U=0.55 170.94 ft2 SHGC: SHGC=0.22 b. U-Factor: NIA ft2 12. Cooling systems kBtu/hr Efficiency SHGC a. Central Unit 28.6 SEER:16.00 c. U-Factor: NIA ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 28.6 HSPF:9.00 SHGC; Area Weighted Average Overhang Depth: 1.918 ft. Area Weighted Average SHGC: 0.220 14. Hot water systems 8. Floor Types Insulation Area a. Electric Cap: 50 gallons (1315.0 sqft.) EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1315.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor 4 Total Proposed Modified Loads: 45.59 Area: 0.130 -PASS Total Baseline Loads: 50.56 I hereby certify F that the plans and specifications covered by Review of the plans and vHE S7,,q?� this calculation are in compliance with the Florida Energy specifications covered by this 0 Code. � calculation indicates compliance BY:. I with the Florida Energy Code. ~ PREPARED DATE: Before construction is completed this building will be inspected forWO compliance with Section 553.908 y $ a * �_ 8/23/18 Ben amin Jensen I hereby certify that this building, as desi ned, is in co rice Florida Statutes. 1�, CDD with the Flo j ida Energ ode. ypE'1�� OWNER/AGENT. BUILDING OFFICIAL: DATE: ° DATE: - ComplianceFequires c rtification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). F �'rJPY 8/23/2018 0:17 AM I EnergyGauge® USA FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4