HomeMy WebLinkAboutENERGY EFFICIENCY CODEi
i
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Nalme: Lot 17 - James Jenkins Residence
Builder Name: Classic Construction of South Florida Inc
Street: Fort Walton Avenue
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Owner: I
Permit Number:
Jurisdiction: 661000
A'
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate
Zone 2)
1. New construction or existing New (From Plans)
9. Wall Types (1476.0 sqft.)
Insulation
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=5.0 1287.00"�
3. Number of if family 1
b. Frame - Wood, Adjacent
R=11.0 189.00 ft'
units, multiple
c. NIA
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (1315.0 sqft.)
Insulation Area
5. Is this a worst case? No
6. Conditioned floor area above grade (1`12) 1315
a. Under Attic (Vented)
b. N/A
R=30.0 1315.00 ft2
R= ft2
Condition) d floor area below grade (ft2) 0
c. N/A
11. Ducts
R= ft2
R ft2
7. Windows(170.9 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 263
a. U-Factor. Dbl, U=0.55 170.94 ft2
SHGC: SHGC=0.22
b. U-Factor: NIA ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC
a. Central Unit
28.6 SEER:16.00
c. U-Factor: NIA ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
28.6 HSPF:9.00
SHGC;
Area Weighted Average Overhang Depth: 1.918 ft.
Area Weighted Average SHGC: 0.220
14. Hot water systems
8. Floor Types Insulation Area
a. Electric
Cap: 50 gallons
(1315.0 sqft.)
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1315.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor
4 Total Proposed Modified Loads: 45.59
Area: 0.130
-PASS
Total Baseline Loads: 50.56
I hereby certify
F
that the plans and specifications covered by
Review of the plans and
vHE S7,,q?�
this calculation
are in compliance with the Florida Energy
specifications covered by this
0
Code.
�
calculation indicates compliance
BY:. I
with the Florida Energy Code.
~
PREPARED
DATE:
Before construction is completed
this building will be inspected forWO
compliance with Section 553.908
y $ a
* �_
8/23/18 Ben amin Jensen
I hereby certify that this building, as desi ned, is in co rice
Florida Statutes.
1�,
CDD
with the Flo j ida Energ ode.
ypE'1��
OWNER/AGENT.
BUILDING OFFICIAL:
DATE: °
DATE:
- ComplianceFequires c rtification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
F
�'rJPY
8/23/2018 0:17 AM
I
EnergyGauge® USA FlaRes2017 Section R405.4.1 Compliant Software