Loading...
HomeMy WebLinkAboutKSM REPORT1 IV CYIlk Ar AM f9VA KELLER, SCHLEICHER.& MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772} 337-7755 RO. BOX 78-1377 SEBASTIAN FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-9093 C.A.: 5693 FAX (772) 589-6469 November 30, 2018 FT I E rn nxf Classic Construction of South Florida Inc Gary Dryden 9425 Avenel Lane . Port St Lucie, FL 34986 Re: 7801 Fort Walton Avenue Lakewood Park Ft. Pierce, Florida Permit #: , 1809-0214 KSM Project #: 184118-1 d Dear Sir: We coul7ty Enclosed; please find the nuclear density test results performed on the compacted foundation fill at the above referenced project. ShoI416yow.have.any questions, please feel free to contact the office. °°° V -tom. —"xC rS45c' Email to: godryden@msn.com Fax and Mail to: St. Lucie County Building Department Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 y � J VI 9 NL go M KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-9093 C.A.: 5693 FAX (772) 589-6469 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED: November 29th, 2018 KSM JOB #: 184118-1 d/SS/ct PERMIT #: i 1809-0214 CONTRACTOR: Classic Construction of South Florida Inc JOBS LOCATION: 7801 Fort Walton Avenue Lakewood Park Ft. Pierce, Florida MATERIAL: Brown & Gray Sand with Clay ITEM TESTED: Compacted Foundation Fill -----=----------=------------------------------=--------------------- TEST LOCATION DEPTH MOIS- PEN DRY MAX. DRY PERCENT OF SAMPLE TURE READ DENSITY PROCTOR COMPACTION --------------------------------------------------------------------- VALUE 1-5' Lifts 1. N.E. 12" - 24" 11.0 46 110.8 114.0 97.2 2. S.E. 50 111.7 It98.0 3. Center 46 110.1 96.6 4. S.W. 50+ 112.6 98.8 5. N.W. 49 111.4 97.7 Final Lift 6. N.I=. 0" -12" 9.9 48 111.0 114.0 97.4 7. S. E. 44 109.6 96.1 8. Center 9946 110.2 . 96.7 9. S.W. 50+ 113.1 99.2 10. N.W. 50+ 112.5 98.7 Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, RE.: 68366 f hFJ AVA KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, I -NC. MARTIN (772) 337-7755 P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) 845-8876 E-Mail: KSMQKSMENGINEERING.NET ST. LUCIE (772) 229-9093 C.A.: 5693 FAX (772) 589-6469 MOISTURE -DENSITY RELATIONSHIP MODIFIED PROCTOR (ASTM D 1557) DATE TESTED: November 29t", 2018 KSM JOB #: 184118-1 p PERMIT #: 1809-0214 CONTRACTOR: Classic Construction of South Florida Inc JOB LOCATION: 7801 Fort Walton Avenue Lakewood Park Ft. Pierce, Florida 115-F---T---,----I----r---T ---, I I I I I I I I I I I I I I I I I I I I I 114 -IIIIIII ------- /—- 113 ------ IIIIII ---- 112 --IIIIIIII +----+---�----I---- j----+----I I I I I I I I I I I I I I I I I I 8 9 10 11 12 13 14 Moisture - Percent of Dry Weight Soil Description: Brown & Gray Sand with Clay I Max. DryDensity: 114.0 P.C.F. Optimum Moisture: 11.0 Percent Julie E. Keller, P.E. President Ronald G. Keller, P.E.: 37293 1 Sl Lic. No.: 860 / Julie E. Keller, P.E.: 68366