"s Certification for Design Load Compliance
Project Name: Myrtil Residence - New G"onstruction
Project Address: 2208 Cortez Blve. Ft. Pierce, FI. 34982
4"
Permit #: Occupancy Type: R3 Construction Type: VB
I
INSTRUCTIONS FOR USE: 4ry�
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
I
1. DESIGN CODE: Florida 2017 Code Sixth Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV Exposure Category: B X C D
4. Design Wind Velocity 124 mph X ASD _LRFD End Zone Width: 4 ft
5. Mean Roof Height 15 ft Roof Pitch: 5 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'.MRH, clearly label on all plan openings):
Zone 1: +13.6i-27.8 Zone 2: +17'7/-43.1 Zone 3: +19.3/-79.0 Zone 4: +29.4i-31.3 Zone 5: +30.0i-37.9 Garage: N/A.
7. Design Loads: Floor: 40 PSF Roof/Dead: 17 PSF Roof/Live: 20 Balcony: NSA PSF
N/A N/A N/A N/A N/A
I Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
19
I
I
Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? X Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design.
forces specified:
ROBERT F. SONBERG RA0006280
Print Name Cert # & Co. Cert Auth.
RFS ARCHITECTS 113 BENT TREE DR. P.B.G., FL
Company Name & Address