Loading...
HomeMy WebLinkAboutCERTIFICATE FOR LOAD COMPLIANCE1Planning & Development Services Department • Building & Code Regulations Division RECEIVED 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 46 -1553 5EP � � 2�i3 Certification for Design Load Compliance Project Name: Myrtil Residence - New Construction ST. Lucie County, Pernlltl ng Project Address: 2208 Cortez Blve. Ft. Pierce, FI. 34947 Permit #: Occupancy Type: R3 Construction Type: VB SCANNED INSTRUCTIONS FOR USE: BY • This certification must be completed, signed, and sealed by the design professional of record. St Lucie County • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Code Sixth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed Open 3. Risk Category: _I X II _III _ IV Exposure Category: B X C D 4. Design Wind Velocity 124 mph X ASD _LRFD End Zone Width: 4 ft S. Mean Roof Height 15 ft Roof Pitch: 5 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +13.6/-27.6 Zone 2: +17.7/-43.1 Zone 3: +19.31-79.0 Zone 4: +29.4/-31.3 Zone 5: +30.0/-37.9 Garage: N/A 7. Design Loads: Floor: 40 PSF Roof/Dead: 17 PSF Roof/Live: 20 Balcony: NSA PSF N/A N/A N/A N/A N/A Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: ROBERT F. SONBERG RA0006280 Robert-F. Sonb�rg-.. Signature, Date, and Seal I vv Print Name Cert # & Co. Cert Auth. RFS ARCHITECTS 113 BENT TREE DR. P.B.G., FL Company Name & Address