HomeMy WebLinkAboutD O H SEWAGE TREATMENT - DISPOSAL INSPECTION AND FINAL APPROVAL 4-17-19y l APPLICATION # : AP1360264
v� K
STATE OF FLORIDA �� PERMIT #: 56-SF-1859695
f. DEPARTMENT OF HEALTH DOCUMENT #:F11263230
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM 08/16/2018
CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:
.ry°OowEs FEE PAID:515.00
RECEIPT #:56-PID-3656029
APPLICANT: Duvilla & Marie Myrtil
AGENT: BSE Construction Group
PROPERTY ADDRESS: 2208 Cortez Blvd Fort Pierce FL 34982 QUANNE0
AV
LOT:
I
BLOCK:
'StLucie
6 county
SUBDIvISiON :
ID# : 2124.234.0005-000-3
I
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED.
TANK INSTALLATION
SETBACKS
[ ] [01]
TANK SIZE [11 1090.00 [21 483.00
[ ] [27]
SURFACE WATER FT
[ ] [j02]
TANK MATERIAL Polypropylene
[ ] [28]
DITCHES 24 FT
[ ] [1031
OUTLET DEVICE
[ ] [29]
PRIVATE WELLS FT
[ ] [94]
MULTI -CHAMBERED [ Y N ]
[ ] [301
PUBLIC WELLS FT
[ ] 1951
OUTLET FILTER Polylok PL-68
[ ] [311
IRRIGATION WELLS FT
[ ] [06]
LEGEND 1. 70-143-11DC3 2. 70-143-54SC4
[ ] [32]
POTABLE WATER 5 FT
[ ] [07]
WATERTIGHT
[ ] [33]
BUILDING FOUNDATIONS 6 FT
[ ] 1081
LEVEL
[ ] [341
PROPERTY LINES 8 FT
[ ] 1091
DEPTH TO LID
[ J [351
OTHER FT
DRAINFIELD INSTALLATION
FILLED /MOUND SYSTEM
[ ] [10]
AREA [11 339.6 [2] SQFT
[ ] 136]
DRAINFIELD COVER
[ ] [11]
DISTRIBUTION BOX HEADER X
[ ] [371
SHOULDERS
[ ] [12]
NUMBER OF DRAINLINES 1. 5.00 2.
[ ] [381
SLOPES
[ ] [13]
DRAINLINE SEPARATION
[ ] [391
STABILIZATION
[ ] [14]
DRAINLINE SLOPE
[ ] [15]
DEPTH OF COVER
ADDITIONAL INFORMATION
[ ] 116]
ELEVATION [ ABOVE / BELOW ]BM 2.00
[ ] [40]
UNOBSTRUCTED AREA
[ ] [17]
SYSTEM LOCATION
[ ] [411
STORMWATER RUNOFF
[ ] [18]
DOSING PUMPS 1.00
[ ] [42]
ALARMS
[ ] [19]
AGGREGATE SIZE
[ ] [43]
MAINTENANCE AGREEMENT
[ ] [20]
AGGREGATE EXCESSIVE FINES
[ ] [44]
BUILDING AREA
[ ] [21]
AGGREGATE DEPTH
[ ] [45]
LOCATION CONFORMS WITH SITE PLAN
[ ] [461
FINAL SITE GRADING
FILL
/ EXCAVATION MATERIAL
[ ] [471
CONTRACTOR MICHAEL W STUHR (ASHTO
[ ] [22]
FILL AMOUNT
[ ] [48]
OTHER INFILTRATOR Quick4 Plus EQ36 LP
[ ] [23]
FILL TEXTURE
[ ] [29]
EXCAVATION DEPTH
ABANDONMENT
[ ] [25]
AREA REPLACED
[ ] [491
TANK PUMPED
[ ] [261
REPLACEMENT MATERIAL
[ ] [501
TANK CRUSHED & FILLED
Comments Comments are on page 2.
I
/
!� O
St. Lucie CHD DATE: 01/30/2019
CONSTRUCTION
I APPROVED
DISAPPROVED ] ° En onmental Specialist II Brian J Ingram (ENVIRONMENTAL HEALTH)
[ / � h
St. Lucie CHD DATE: 04/17/2019
FINAL SYSTEM
APPROVED DISAPPROVED ]:
Environmental Specialist I Hunter A Collier (Florida Department of Hea
(Explanatioin of Violations on following page)
DR 4016, 68/09 (Obsoletes all previous editions which may not be used)
Page 2 of 3
Incorporated:
64E-6.003, FAC
EH Database v 1.0.1 AP1360264
EID1959695
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
Comment
APPLICATION # : AP1360264
PERMIT #:56-SF-1859695
DOCUMENT #: F11263230
DATE PAID:08/16/2018
FEE PAID :515.00
RECEIPT #:56-PID-3656029
The system is sized for 2 bedrooms with a maximum occupancy of 4 persons (2 per bedroom), for a total estimated flow of 200
gpd.
New ST, '[ter, DT, 1/3 hp liberty pump, and 5x6 long DF installed. No violations, system ok to cover. Contractor notified onsite.
Needs final inspection for mound system, alarm check, and final site grading.
Final inspection approved. Emailed to building department and contractor.
11
DH 40161 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1360264 EID1859695