Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEW .,, i ORM R405-201.7 FILE COPY FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residen l'ai`P`grMetho ProjectName. MyrtilResidence. Builder Name: QuickCatcs,nc. S!'ia i 4 ,'1n _ - Compliances requirescertification bythe .air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in,accordance with R403.3.2.1. - Compliance require&&' nAir Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report withenvelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 9:03 AM EnergyGauge® USA Section. R405A.1 Compliant Software Page 1 of 5 'FJ Z r FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Ttle: MyrtilResidence Bedrooms: 2 AddressType: StreetAddress i BuildingType: User ConditionedArea: 1100 Lot# CwnerName: MyrtilResidence TotalStories: 1 BlocldSubdivision: Units: 1 WorstGase: No PlatBook: Bof uildetName: Quick Cales, Inc. Rotate Angler 0 Street: 2208 Cortez Boulevard Permit Office- CrossVehtilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City,, State, Zip: Fort Pierce , �+IIamilyType: Single=family FL, 34982 New/Existing: New (Flom Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp DesignLocation TMYSite 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort'Pierce FL VERO BEACH_ MUNI 3990 I 70 75 299 62 Low BLOCKS J Number Name Area Volume 1 Entire House 1100 8800 SPACES Number Name. Area Volume '• Kitchen Occupants Bedrooms tnfilID, Finished Cooled Heated 1 Master Bedroom 183 1464 No. 2 1 1 Yes Yes Yes 2 Mast: Bath 66 '528 No 0 1 Yes Yes Yes 3 Utility 48 384. No 0 1 No Yes Yes 4 Bath 48 384 No 0 1 Yves Yes Yes 5 Bedroom: 168• 1344 No jr 1 1 Yes Yes Yes. 6 Kitchen 169 1352 Yes 0 1 Yes Yes Yes• 7 Dining 78 624 No 0 1 Yes Yes Yes 8 Living Room 259 2072 No 1 1 Yes Yes Yes 9 Hall 45 360 No 0 1 No Yes Yes 10 Foyer 36 288 No 0 1 Yes Yes Yes FLOORS. # • Floor Type Space Perimeter Peri Meter R-Value Area JoistR4alue Tile Wood Carpet 1Slab-On-Grade Edgelnsulatio Master Bedroom 29#t 0 183ft2 0 l 0 2 Slab -On -Grade Edgelnsulatio Mast. Bath 6 ft 0 66 ft' _ 0 1 0 3Slab-On-Grade Edgelnsulatio Utility 1 ft 0 48ft2 _ 0 1 0 4 Slab -On -Grade Edgelnsulatio Bath 6 ft 0 48 fig 0 1 0 5 Slab -On -Grade Edgelnsulatio Bedroom 31 ft 0 1680 0 1 0 6.Slab-On-Grade Edge Insulatio Kitchen 26ft 0 169ft' ___ 0 1 0 7 Slab=On-Grade Edge Insulatio Dining 6 ft 0 78 ft2 0 1 0 8 /2018 9:03 AM EnergyGaugeS USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-20.17 INPUT SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood_ Carpet 8Siab-On-Grade Edgeinsulatio Living Room 33ft 0 259f1:2 r__ 0 1 0 9 Slab -On -Grade Edge lnsuiatio Hall t ft 0 45 fftz _ 0 1' 0 I 10SIab-On-Grade Edgelnsulatio Foyer Eft 0 36ft2 __ 1 0 0 ROOF V # Roof Type Materials Area Gable Area Roof Color Solar SA Emitt Absor. Tested Einitt Tested Deck., Insul. Pitch (deg) I 1 Hip Compositionshingles 1191 ft2 0 ft2 Dark 0.6 No 0.9 No 0 22.6 ATTIC VType Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Fuilattic Vented 300 1100ft2 N N CEILING # Ceiling Type Space R-Value InsType Area Framing Fred TrussType 1 UnderAttic(Vented), MasterBedroom 30 Batt 183ft2 0.1' Wood 2 UnderAttic(Vented) Mast. Bath 30 Batt 66 ft2 01 Wood 3 UnderAttic (Vented) Utility 30 Batt 48 ft2' 0.1 Wood 4 UnderAttic (Vented) Bath 30 Batt 48 fF 0.1. Wood 5 Under Attic Bedroom 30 Batt 168ft2 0.1 Wood 6 Under Attic (Vented) Kitchen 30 Batt 16912 0.1 Wood 7 UnderAttic(Vented) Dining 30 Batt 78 ft2 0.1 Wood 8 UnderAttic(Vented) Living Room 30 Batt 259'ft2 0.1 Wood I. 9 10 Under Attic (Vented) Hall Under Attic (Vented) Foyer 30 30 Batt Batt 45ft2 36 ft2 0.1 0.1 Wood. Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below, 1 2 SE SW Exterior Concrete Block- Ext InsBAaster Bedro Exterior Concrete Block- Ext IriSBGaster Bedro 9 17 9 12 0 8 0 8 0 0 138.0 ft2 g6.0 ft2 0 0 0 0 0:6 0.6 0 0 3 SW Exterior Concrete Block - Ext lnsulMastBath 9 6 0 8 0 48.0'ft2 0 0 0.6 0 4 SE Exterior 'Concrete Block- Ext Insul ,Bath 9 6 0 8 0 48.0ft21 0 0 0.6 0 5 NE . Exterior Concrete Block - Ext lnsul. Bedroom 9 12 0 8 0 96.0 ft2 0 0 0.6 0 6 SE Exterior Concrete Block - Ext Insul Bedroom 9 14 0 8 0 112.0 ft2 0 0 0.6 0 7 NW Exterior Concrete Block - Ext Insul Bedroom 9 5 0 8 0 40.0ft2 0 0 0.6 0 8 SW Exterior Concrete Block-Ext Insul Kitchen 9 13 0 8 0 104.0 ft2 0 0 0.6 0 9 NW Exterior Concrete Block- Ext Insul Kitchen 9 13 0 8 0 104.0 ft2 0 0 0.6 0 10 NW Exterior Concrete Block-Extlnsul Dining 9 6 0 8 0 48.0ft2 0 0 0.6 0 11 NE Exterior Concrete Block-Ext insdtiving Room 9 19 0 8 0 152.0 ft2 0 0 0.6 0 12 NW Exterior Concrete Block - Ext lnurfivingRoom 9 14 .0 8 0 112.0ft2 0 0 0.6 0 8j 7/2018 9:03 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST RFPnRT WALLS Adjacent WAII Space Cavity Width Height Sheathing Framing Solar Below 13 NE Exterior Concrete Block- Ext Insui Foyer 9 6 6 8 0 48.0 ft2 0 0 0.6 0 DOORS IV # Omt Door Type Space Storms U-Value Width Ft In Height Ft In Area. I 1 2 NW NE Wood Wood Kitchen None .6 3 Foyer None .6 3 6 10 6 10 20.5 ft2 20.5 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / # 1 2 3 4 5 Wall Omt ID Frame SW 2 Vinyl NE 5 Vinyl SW 8 Vinyl NW 10 Vinyl NE 11 Vinyl Panes Single (Clear) Single(Clear) Single (Clear) Single (Clear), Single.(Clear) Overhang NFRC U-Factor SHGC Imp -Area Depth Separation Yes 0.4 0.2 N 15.5 ft2 1 ft 0 in 1 ft 4 in Yes 0.4 0.2 N 15.612 1 ft 0 in 1 ft4 in Yes 0.4 0.2 N 9.1 ft? 1 ft 0 in 1 ft 4 in Yes 0.4 0.2 N 9.6 ft2 1 ft 0 in 1 ft 4 in Yes 0.4 0.2 N 9.5 ft; 9 ft 0 in 1.ft 4 in IntShade None None None None None Screening None None None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .0003W6 1026.7 56.36 106 :2576 7 HEATING SYSTEM' # System.T.ype Subtype Efficiency Capacity 'Block Ducts 1 I Electric Strip Heat/ None C00:1 17 kBtuthr 1 sys#1 COOLING SYSTEM Systemtype Subtype Efficiency Capacity AlrFlow ' SHR Block Ducts 1 I Central Unit/ Split SEER: 16 24 kBtu/hr cfm. 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 I Electric None Utility 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model# Collector Model # Area Storage Volume FEF None None I ft2 18 9:03 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT RUMMARY r-Wml IRT RFPnRT DUCTS V --Supply— — Return — Air GFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 150 ft2 Attic 35 ft2 Default Leakage Hall (Default) (Default), 1 1 TEMPERATURES rogramableThermostat: Y Ceiling Fans: Colin Heating Jan Feb Jan Feb Mar Mar Apr Apr I May Jun Jun Jul Jul Auge Aug Sep Oct Nov Dec Jan Feb Mar Maay Jun Jul Aug -Sep Oct Nov Decng ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 76 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 He (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 68 MASS MassType Area Thickness, FumitureFraction Space Default(8lbs/sq.ft. 0R2 Oft 0.3 Master Bedroom Default(8lbs/sq.ft. ft2 ft 0.3 Mast. Bath Default(81bs/sq.ft. ft2 ft 0.3 Utility Default(8lbs/sq.ft. ft2 ft 0.3 Bath Defauft(81bs/sq.ft. ft2 ft 0.3 Bedroom Defauit(8lbs/sq.ft. ft2 ft 0.3 Kitchen Default(8lbs/sq.ft. ft2 ft` 0.3 Dining Default(8)bs/sq.ft. ftz ft 0.3 Living Room Default(8lbs/sq.ft. ft2 ft 0.3 Hall Default 8lbs/s .ft. ft2 ft 0:3 Foyer Name: Rating Compant: (q1tri, , LIM I i i I I I - TVIN, MI Date: 8 9:03 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5 017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Myrtil Residence Builder Name: Quick Cates„ Inc.. Street 2.208Cortez Boulevard Permit Office: City; State, Zip: Fort Pierce , FL , 34982 Permit Number: Owner: Myrtil Residence Jurisdiction: Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeatiWinsulation shall requirements. The exterior thermal,envelope contains a continuous air barrier. Breaks or joints inth&air barrier shall be sealed. not be used as. a sealing material. Ceiling/attic The air barmerin any dropped ceiling/soffit hall be.aligmed with the insulation and any gaps in the air barrier shall be sealed. The:insulation in any dropped ceiling/soffit Access openings,. drqR down stales or knee wall doors to shall be aligned with the -air barrier. unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and -headers of Varna wall The junction of the top -plate and.the•top-of exterior walls shall be shall be insulated by completelyfilling the cavity sealed. Knee walls:shall, be sealed. with a material having a thermal resistance:of R-3 per inch minimum. Exterior thermal envelope Insulation for framed walls shall be'installed in substantial -contact and skylights The space between-window/doorjambs and framing, and continuous alignment withthe air barrier. I and doors skylights and`framing, shall: be sealed: k2im joists Rim joists shall include.the air barrier. Rim,joistsshall be. Insulated. Moors The air barrier shall be irfstalled;at anyexposed,edge of insulatiom. Tiborframing cavity insulation-shall,be installed -to P(including ove-garage maintain permanent contact with -the undersid&of 'subffoor and cantilevered. decking, -or floor framing cavity insulation oors) shall`be permitted.to be in contact withthe top side "sheathing, of or continuous insulationinstalled,on the underside; of floor framing•andrextends from the bottom.to:the top of all perimeter floor framing members: Crawl space walls Exposed earth in unvented.crawl•spaces shallbe:covered,Wth Where provided lnstead'of floor insulation, insulation a. Class l vapor retarder with overlapping. Joints taped. shall be permanently attached to the-crawispace Shafts, penetrations Duct shafts„utill ty penetrations, and clue shafts opening to exterior or unconditioned space shall!be sealed. Batts in narrow cavities shall be cutto•fit, or narrow Narrow cavities - cavities shall, be filled' by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing, shall be provided: between the garage and conditioned spa - s. ecessed lighting. Recessed light -fixtures instalied1n,the building thecnial;envelope Recessed light fixtures installed Inthe.building i shall be sealed to the:drywall: thermal envelope shall' be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut,neatly to fit around Wring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall. S�howerltub_ on exterior wail The air barrier Installed at exterior walls adjacent to�showers and Exterior walls adjacent to showers.and'tubs shall tubs shall; separate.them from the showers and:tubs. be insulated: Electricallphone box or exterior The air barrier shali be installed behind'electrical or communication wails boxes or air -sealed boxes shall: be installed: AVAC register boots IHVAC register boots that penetrate, building. thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be s rmklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids Mates a.�in addition, InSpeCtlOm"of i1prInklar cover loo walls shall ha in'aernnianna unfM;tl� .,:..;...... < i n inn 8 J201.8 9:04 AM EnergyGaugee USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 3. No. of units'(if multiple -family) 3. 1 c) AHU location Attic/Attic 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 24.0 a) Split system SEER 1.6.0 5: Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq.. ft.) 6. 1100 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.400 b) Solar Heat Gain Coefficienf (SHGC) 7b. 0.200 14. Heating system: Capacity 17.0 c) Area 7c. 59.2 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1:.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat -Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type,.insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised' (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95. 1Wall type and insulation: b) Gas fired, natural gas EF c) Gas fired, LPG EF c) A. Exterior: d) Solar system with. tank EF 1. Wood frame (Insulation R-value) 1OA1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 1 OA2. 9.0 f) Heat recovery unit. HeatRec% 13. Adjacent: g) Other 1. Wood°frame (insulation R-value) 10B1. 2. Masonry (Insulation R-value) 10132. 11. Ceiling type and insulation level 16. HVAC credits claimed (Performance Method) a) Ceiling fans Yes a) Under attic 11a. 30.0 b) Cross ventilation No b)-Single assembly 11b, c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303A.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has compiled with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before -final inspection. Otherwise, a new EPL display card will be completed d on installed code compliant features. Builder Signature: Date: -7 Address of New Home: - 2208 Cortez Boulevard City/FL Zip: Fort Pierce, FL 34982 9:03:58 AM EnergyGaugeg USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software, Page 1 of 1