FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residen l'ai`P`grMetho
ProjectName. MyrtilResidence. Builder Name: QuickCatcs,nc. S!'ia i 4 ,'1n
_ - Compliances requirescertification bythe .air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in,accordance with R403.3.2.1.
- Compliance require&&' nAir Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report withenvelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
9:03 AM EnergyGauge® USA Section. R405A.1 Compliant Software Page 1 of 5
'FJ
Z
r
FORM
R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Ttle:
MyrtilResidence
Bedrooms: 2
AddressType:
StreetAddress
i BuildingType:
User
ConditionedArea: 1100
Lot#
CwnerName:
MyrtilResidence
TotalStories: 1
BlocldSubdivision:
Units: 1
WorstGase: No
PlatBook:
Bof
uildetName: Quick Cales, Inc.
Rotate Angler 0
Street:
2208 Cortez Boulevard
Permit
Office-
CrossVehtilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City,, State, Zip:
Fort Pierce ,
�+IIamilyType:
Single=family
FL, 34982
New/Existing:
New (Flom Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating Design Daily Temp
DesignLocation
TMYSite 97.5% 2.5%
Winter
Summer Degree Days Moisture
Range
FL, Fort'Pierce FL VERO BEACH_ MUNI 3990
I
70
75 299
62
Low
BLOCKS
J
Number Name
Area Volume
1 Entire House
1100 8800
SPACES
Number Name.
Area Volume '• Kitchen Occupants
Bedrooms
tnfilID, Finished Cooled
Heated
1 Master Bedroom
183 1464 No. 2
1
1 Yes
Yes
Yes
2 Mast: Bath
66 '528 No 0
1 Yes
Yes
Yes
3 Utility
48 384. No 0
1 No
Yes
Yes
4 Bath
48 384 No 0
1 Yves
Yes
Yes
5 Bedroom:
168• 1344 No jr
1
1 Yes
Yes
Yes.
6 Kitchen
169 1352 Yes 0
1 Yes
Yes
Yes•
7 Dining
78 624 No 0
1 Yes
Yes
Yes
8 Living Room
259 2072 No 1
1 Yes
Yes
Yes
9 Hall
45 360 No 0
1 No
Yes
Yes
10 Foyer
36 288 No 0
1 Yes
Yes
Yes
FLOORS.
# • Floor Type
Space Perimeter Peri Meter R-Value
Area
JoistR4alue
Tile Wood Carpet
1Slab-On-Grade Edgelnsulatio
Master Bedroom 29#t 0
183ft2
0 l
0
2 Slab -On -Grade Edgelnsulatio
Mast. Bath 6 ft 0
66 ft'
_
0 1
0
3Slab-On-Grade Edgelnsulatio
Utility 1 ft 0
48ft2
_
0 1
0
4 Slab -On -Grade Edgelnsulatio
Bath 6 ft 0
48 fig
0 1
0
5 Slab -On -Grade Edgelnsulatio
Bedroom 31 ft 0
1680
0 1
0
6.Slab-On-Grade Edge Insulatio
Kitchen 26ft 0
169ft'
___
0 1
0
7 Slab=On-Grade Edge Insulatio
Dining 6 ft 0
78 ft2
0 1
0
8
/2018 9:03 AM
EnergyGaugeS USA Section R405.4.1 Compliant Software
Page 2 of 5
FORM
R405-20.17 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
FloorType Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile
Wood_ Carpet
8Siab-On-Grade Edgeinsulatio Living Room 33ft 0
259f1:2
r__
0
1
0
9 Slab -On -Grade Edge lnsuiatio Hall t ft
0
45 fftz
_
0
1'
0
I
10SIab-On-Grade Edgelnsulatio Foyer Eft
0
36ft2
__
1
0
0
ROOF
V
#
Roof
Type Materials Area
Gable
Area
Roof
Color
Solar SA Emitt
Absor. Tested
Einitt
Tested
Deck.,
Insul.
Pitch
(deg)
I
1
Hip Compositionshingles 1191 ft2
0 ft2
Dark
0.6 No
0.9
No
0
22.6
ATTIC
VType
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Fuilattic Vented
300
1100ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
InsType
Area
Framing Fred TrussType
1
UnderAttic(Vented), MasterBedroom
30
Batt
183ft2
0.1'
Wood
2
UnderAttic(Vented) Mast. Bath
30
Batt
66 ft2
01
Wood
3
UnderAttic (Vented) Utility
30
Batt
48 ft2'
0.1
Wood
4
UnderAttic (Vented) Bath
30
Batt
48 fF
0.1.
Wood
5
Under Attic Bedroom
30
Batt
168ft2
0.1
Wood
6
Under Attic (Vented) Kitchen
30
Batt
16912
0.1
Wood
7
UnderAttic(Vented) Dining
30
Batt
78 ft2
0.1
Wood
8
UnderAttic(Vented) Living Room
30
Batt
259'ft2
0.1
Wood
I.
9
10
Under Attic (Vented) Hall
Under Attic (Vented) Foyer
30
30
Batt
Batt
45ft2
36 ft2
0.1
0.1
Wood.
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing
Solar
Below,
1
2
SE
SW
Exterior Concrete Block- Ext InsBAaster Bedro
Exterior Concrete Block- Ext IriSBGaster Bedro
9 17
9 12
0 8
0 8
0
0
138.0 ft2
g6.0 ft2
0
0
0
0
0:6
0.6
0
0
3
SW
Exterior Concrete Block - Ext lnsulMastBath
9 6
0 8
0
48.0'ft2
0
0
0.6
0
4
SE
Exterior 'Concrete Block- Ext Insul ,Bath
9 6
0 8
0
48.0ft21
0
0
0.6
0
5
NE .
Exterior Concrete Block - Ext lnsul. Bedroom
9 12
0 8
0
96.0 ft2
0
0
0.6
0
6
SE
Exterior Concrete Block - Ext Insul Bedroom
9 14
0 8
0
112.0 ft2
0
0
0.6
0
7
NW
Exterior Concrete Block - Ext Insul Bedroom
9 5
0 8
0
40.0ft2
0
0
0.6
0
8
SW
Exterior Concrete Block-Ext Insul Kitchen
9 13
0 8
0
104.0 ft2
0
0
0.6
0
9
NW
Exterior Concrete Block- Ext Insul Kitchen
9 13
0 8
0
104.0 ft2
0
0
0.6
0
10
NW
Exterior Concrete Block-Extlnsul Dining
9 6
0 8
0
48.0ft2
0
0
0.6
0
11
NE
Exterior Concrete Block-Ext insdtiving Room
9 19
0 8
0
152.0 ft2
0
0
0.6
0
12
NW
Exterior Concrete Block - Ext lnurfivingRoom
9 14
.0 8
0
112.0ft2
0
0
0.6
0
8j
7/2018 9:03 AM EnergyGauge® USA Section
R405.4.1 Compliant Software
Page
3 of 5
FORM R405-2017
INPUT SUMMARY CHECKLIST RFPnRT
WALLS
Adjacent WAII
Space Cavity Width Height Sheathing Framing Solar Below
13 NE
Exterior Concrete Block- Ext Insui Foyer 9 6 6 8 0 48.0 ft2 0
0 0.6
0
DOORS
IV
#
Omt
Door Type
Space Storms U-Value Width
Ft In
Height
Ft In
Area.
I
1
2
NW
NE
Wood
Wood
Kitchen None .6 3
Foyer None .6 3
6 10
6 10
20.5 ft2
20.5 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
#
1
2
3
4
5
Wall
Omt ID Frame
SW 2 Vinyl
NE 5 Vinyl
SW 8 Vinyl
NW 10 Vinyl
NE 11 Vinyl
Panes
Single (Clear)
Single(Clear)
Single (Clear)
Single (Clear),
Single.(Clear)
Overhang
NFRC U-Factor SHGC Imp -Area Depth Separation
Yes 0.4 0.2 N 15.5 ft2 1 ft 0 in 1 ft 4 in
Yes 0.4 0.2 N 15.612 1 ft 0 in 1 ft4 in
Yes 0.4 0.2 N 9.1 ft? 1 ft 0 in 1 ft 4 in
Yes 0.4 0.2 N 9.6 ft2 1 ft 0 in 1 ft 4 in
Yes 0.4 0.2 N 9.5 ft; 9 ft 0 in 1.ft 4 in
IntShade
None
None
None
None
None
Screening
None
None
None
None
None
INFILTRATION
#
Scope
Method
SLA CFM 50 ELA EgLA ACH ACH 50
1
Wholehouse ProposedACH(50) .0003W6 1026.7 56.36 106 :2576
7
HEATING SYSTEM'
#
System.T.ype
Subtype Efficiency Capacity
'Block
Ducts
1
I
Electric Strip Heat/
None C00:1 17 kBtuthr
1
sys#1
COOLING SYSTEM
Systemtype
Subtype Efficiency Capacity AlrFlow ' SHR Block
Ducts
1
I
Central Unit/
Split SEER: 16 24 kBtu/hr cfm.
0.7 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location EF Cap Use SetPnt
Conservation
1
I
Electric
None
Utility 0.95 50 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector
System Model# Collector Model # Area
Storage
Volume
FEF
None None
I
ft2
18 9:03 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
INPUT RUMMARY r-Wml IRT RFPnRT
DUCTS
V --Supply—
— Return —
Air
GFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT ON RLF
Heat Cool
1 Attic
6 150 ft2
Attic
35 ft2
Default Leakage
Hall
(Default) (Default),
1 1
TEMPERATURES
rogramableThermostat: Y
Ceiling Fans:
Colin
Heating
Jan Feb
Jan Feb
Mar
Mar
Apr
Apr
I
May
Jun
Jun
Jul
Jul
Auge
Aug
Sep
Oct
Nov
Dec
Jan Feb
Mar
Maay
Jun
Jul
Aug
-Sep
Oct
Nov
Decng
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
76
Cooling (WEH) AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
He (WD) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
68
MASS
MassType
Area
Thickness,
FumitureFraction
Space
Default(8lbs/sq.ft.
0R2
Oft
0.3
Master Bedroom
Default(8lbs/sq.ft.
ft2
ft
0.3
Mast. Bath
Default(81bs/sq.ft.
ft2
ft
0.3
Utility
Default(8lbs/sq.ft.
ft2
ft
0.3
Bath
Defauft(81bs/sq.ft.
ft2
ft
0.3
Bedroom
Defauit(8lbs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8lbs/sq.ft.
ft2
ft`
0.3
Dining
Default(8)bs/sq.ft.
ftz
ft
0.3
Living Room
Default(8lbs/sq.ft.
ft2
ft
0.3
Hall
Default 8lbs/s .ft.
ft2
ft
0:3
Foyer
Name:
Rating Compant:
(q1tri, ,
LIM
I i i I I I - TVIN, MI
Date:
8 9:03 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5
017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Myrtil Residence Builder Name: Quick Cates„ Inc..
Street 2.208Cortez Boulevard Permit Office:
City; State, Zip: Fort Pierce , FL , 34982 Permit Number:
Owner: Myrtil Residence Jurisdiction:
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air-permeatiWinsulation shall
requirements.
The exterior thermal,envelope contains a continuous air barrier.
Breaks or joints inth&air barrier shall be sealed.
not be used as. a sealing material.
Ceiling/attic
The air barmerin any dropped ceiling/soffit hall be.aligmed with
the insulation and any gaps in the air barrier shall be sealed.
The:insulation in any dropped ceiling/soffit
Access openings,. drqR down stales or knee wall doors to
shall be aligned with the -air barrier.
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and -headers of Varna wall
The junction of the top -plate and.the•top-of exterior walls shall be
shall be insulated by completelyfilling the cavity
sealed.
Knee walls:shall, be sealed.
with a material having a thermal resistance:of R-3
per inch minimum.
Exterior thermal envelope Insulation for framed
walls shall be'installed in substantial -contact and
skylights
The space between-window/doorjambs and framing, and
continuous alignment withthe air barrier.
I
and doors
skylights and`framing, shall: be sealed:
k2im joists
Rim joists shall include.the air barrier.
Rim,joistsshall be. Insulated.
Moors
The air barrier shall be irfstalled;at anyexposed,edge of
insulatiom.
Tiborframing cavity insulation-shall,be installed -to
P(including
ove-garage
maintain permanent contact with -the undersid&of
'subffoor
and cantilevered.
decking, -or floor framing cavity insulation
oors)
shall`be permitted.to be in contact withthe top side
"sheathing,
of or continuous insulationinstalled,on
the underside; of floor framing•andrextends from the
bottom.to:the top of all perimeter floor framing
members:
Crawl space walls
Exposed earth in unvented.crawl•spaces shallbe:covered,Wth
Where provided lnstead'of floor insulation, insulation
a. Class l vapor retarder with overlapping. Joints taped.
shall be permanently attached to the-crawispace
Shafts, penetrations
Duct shafts„utill ty penetrations, and clue shafts opening to
exterior or unconditioned space shall!be sealed.
Batts in narrow cavities shall be cutto•fit, or narrow
Narrow cavities
-
cavities shall, be filled' by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing, shall be provided: between the garage and conditioned spa
- s.
ecessed lighting.
Recessed light -fixtures instalied1n,the building thecnial;envelope
Recessed light fixtures installed Inthe.building
i
shall be sealed to the:drywall:
thermal envelope shall' be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut,neatly to fit around Wring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall.
S�howerltub_
on exterior wail
The air barrier Installed at exterior walls adjacent to�showers and
Exterior walls adjacent to showers.and'tubs shall
tubs shall; separate.them from the showers and:tubs.
be insulated:
Electricallphone box or
exterior
The air barrier shali be installed behind'electrical or communication
wails
boxes or air -sealed boxes shall: be installed:
AVAC register boots
IHVAC register boots that penetrate, building. thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
s rmklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
Mates
a.�in addition, InSpeCtlOm"of
i1prInklar cover
loo walls shall ha in'aernnianna unfM;tl� .,:..;...... < i n inn
8 J201.8 9:04 AM
EnergyGaugee USA FBC 6th Edition (2017) Compliant Software
Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 92
The lower the Energy Performance Index, the more efficient the home
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
3. No. of units'(if multiple -family)
3.
1
c) AHU location Attic/Attic
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
24.0
a) Split system SEER
1.6.0
5: Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq.. ft.)
6.
1100
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.400
b) Solar Heat Gain Coefficienf (SHGC)
7b.
0.200
14. Heating system: Capacity
17.0
c) Area
7c.
59.2
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1:.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat -Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type,.insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised' (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95.
1Wall type and insulation:
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
c)
A. Exterior:
d) Solar system with. tank EF
1. Wood frame (Insulation R-value)
1OA1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
1 OA2.
9.0
f) Heat recovery unit. HeatRec%
13. Adjacent:
g) Other
1. Wood°frame (insulation R-value)
10B1.
2. Masonry (Insulation R-value)
10132.
11. Ceiling type and insulation level
16. HVAC credits claimed (Performance Method)
a) Ceiling fans Yes
a) Under attic
11a.
30.0
b) Cross ventilation
No
b)-Single assembly
11b,
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d.
No
e) Multizone heating credit
0 Programmable thermostat
Yes
*Label required by Section R303A.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has compiled with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before -final inspection. Otherwise, a new EPL
display card will be completed d on installed code compliant features.
Builder Signature: Date: -7
Address of New Home: - 2208 Cortez Boulevard City/FL Zip: Fort Pierce, FL 34982
9:03:58 AM EnergyGaugeg USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software, Page 1 of 1