Loading...
HomeMy WebLinkAboutPRODUCAT APPROVAL - SWINGING EXTERIOR DOORFlorida Building Cade Online r r ,84al Lurie County Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL15210-R6 Application Type Revision Code Version 2 117 Application Status Approved LE c��Y Product Manufacturer P( lastpro Inc. / Nanya Plastics Corp.) Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES, CA 90045 (440) 969-9773 Ext16 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles, CA 90045 (440)969-9773 Ext18 scottjohnson@plastproinc.com Quality Assurance Representative Ron O'Connell Address/Phone/Email 5200 W Century Blvd. Los Angeles, CA 90045 (440)969-9773 Ext16 ronoconnell@plastpro.com Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a•Florida Registered Architect or a Licensed Florida Professional Engineer 13 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J. King, P.E. E3 Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Q-IN&VAEOR I . - . _ 0.i�%-�Irr417ft__N9rlll app_dtl.aspx?param=vGEVXQwtDgv3yVVKJZIQRCFPqu8gbCgpaL%2fcMd8xBvDdrXKxpoHIdA%3d%3d[811612018 3:25:10 PM] I Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved ASTM D638 ASTM E1300 ASTM E84 ASTM G26 G 155 TAS 201, 202, 203 Florida Licensed Professional Engineer or Architect FL15210 R6 •Eguiv (a) Equivalency of Standards.pdf Method 1 Option D 08/13/2017 09/18/2017 09/20/2017 12/12/2017 2003 2004 2005 1995 2005 1994 Summary, of Products FL* Model, Number or Name -, Description 1 22L0:1 -- Smooth/Wood Grain/White Wood 6'8 "Impact" Opaque'Fibertilass Single Door--'Inswing/Outswing rain/Rustic/Mahogai Series O rFiberalasss Door X - Configura_tion) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R6 II (b) Inst 15210.1.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.1 for Design Pressure Ratings, any FL15210 R6 AE (b) Eval 15210.1.12df additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.2 b. Smooth Wood. Grain/White Wood 6'8 "Impact" Opaque Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series O Sidelites - Inswing/Outswing (OX or XO; OXO - Configurations) Fiberglass Door Limits of Use Installation' Instructions Approved for use in HVHZ: Yes FL15210 R6 II (b) Inst 15210.2.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.2 for Design Pressure Ratings, any FLIS210 R6 AE (b) Eval 15210.2.pdf additional use limitations,, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.3 c. Smooth/Wood Grain/White Wood 6'8 "Impact" Opaque Fiberglass Double Door with or without Grain/Rustic/Mahogany Series O Sidelites - Inswing/Outswing (XX; OXXO - Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FLIS210 R6 II (b) Inst 15210.3.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.3 for Design Pressure Ratings, any FL15210 R6 AE (b) Eval 15210.3.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.4 d. Smooth Wood Grain/White Wood 68 "Impact" Glazed' Fiberglass Single Door - Inswing/Outswing Grain/Rustic/Mahogany Series O (X - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R6 II (b) Inst 15210.4.pdf I https://www.floridaI uilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZIQRCFPqu8gbCgpaL%2fcMd8xBvDdrXYxpoHIdA%3d%3d[8/16/2018 3:25:10 PM] Florida Building Code Online Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes . Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.4 for Design Pressure Ratings, any FL15210 R6 AE (b) Eval 15210.4.2df additional use limitations, installation instructions and product Created .by Independent Third"Party: Yes particulars. 15210.5 e. Smooth/Wood Grain/White Wood 6'8 "Impact" Glazed Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series O Sidelites - Inswing/Outswing (OX or XO; OXO - Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R6 II (b) Inst 15210.5.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes. Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.5 for Design Pressure Ratings, any FL15210 R6 AE (b) Eval 15210.5.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 1521-0.6 f. Smooth/Wood Grain/White Wood 6'8 "Impact" Glazed Fiberglass Double Door with or without Grain/Rustic/Mahogany Series O Sidelites - Inswing/Outswing (XX; OXXO - Configurations), Fiberglass Door. Limits of Use Installation Instructions Approved for use in HVHZ:. Yes FL15210 R6 II (b) Inst 15210.6.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.6 for Design Pressure Ratings, any FLIS210 R6 AE (b) Eval 15210.6.rdf additional use limitations, installation instructions and product Createdby Independent Third Party: Yes particulars. 15210.7 g. Smooth Wood Grain/White Wood 8'0 "Impact" Glazed Fiberglass Single Door - Outswing (X - Grain/Rustic/Mahogany Series 0 Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R6 II (b) Inst 15210.7.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.7 for Design Pressure Ratings, any FL15210 R6 AE (b) Eval 15210.7.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.8 h. Smooth/Wood. Grain/White Wood 8'0 "Impact" Glazed Fiberglass Single Door with• Sidelite or Grain/Rustic/Mahogany Series 0 Sidelites - Outswing (OX or XO; OXO - Configurations) Fiberglass Door Limits of.Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R6 II (b) Inst 15210.8.pdf Approved for use outside HVHZ: Yes Verified' By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.8 for Design Pressure Ratings,.any FL15210 R6 AE (b) Evan 15210.8.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.9 L Smooth/Wood Grain/White Wood 8'0 "Impact" Glazed Fiberglass Double Door with or without Grain/Rustic/Mahogany Series 0 Sidelites - Outswing (XX; OXXO - Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R6 II (b) Inst 15210.9.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.9 for Design Pressure Ratings, any FL15210 R6 AE (b) Eval 15210.9.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.10 j. Smooth/Wood Grain/White Wood 8'0 "Impact" Opaque Fiberglass Single Door-.Outswing (X - Grain/Rustic/Mahogany Series O' Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R6 II (b) Inst 15210.10.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 1QRCFPqu8gbCgpaL / 2fcMd8xBvDdrXKxpoHIdA%3d"/o3d[8/ 16/2018 3:25:10 PM] Florida Building Code Online Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.10 for Design Pressure Ratings, any FL15210 R6 AE (b) Eval 15210.10.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.11 k. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series 0 Fiberglass Door 8'0 "Impact" Opaque Fiberglass Single Door with Sidelite or Sidelites - Outswing (OX or XO; OXO - Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R6 II (b) Inst 15210.11.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.11 for Design Pressure Ratings, any FL15210 R6 AE (b) Eval 15210.11.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.12 1'. Smooth/Wood Grain/White Wood 8'0 "Impact" Opaque Fiberglass Double Door with or without Grain/Rustic/Mahogany Series 0 Sidelites - Outswing (XX; OXXO - Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R6 II (b) Inst 15210.12.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.12 for Design Pressure Ratings, any FL15210 R6 AE (b) Eval 15210.12.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.13 m. Smooth/Wood Grain/White Wood 8'0 "Impact" Opaque Fiberglass Single Door with Surface Bolts Grain/Rustic/Mahogany Series 0 - Outswing (X - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R6 II (b) Inst 15210.13.pddf, Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.13 for Design Pressure Ratings, any FL15210 R6 AE (b) Eval 15210.13.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.14 n. Smooth Wood Grain/White Wood 8'0 "Impact" Opaque Fiberglass Double Door with Surface Bolts Grain/Rustic/Mahogany Series 0 on Active Door panel - Outswing (XX - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R6 II (b) Inst 15210.14.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.14 for Design Pressure Ratings, any FL15210 R6 AE (b) Eval 15210.14.pddf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.15 o. Smooth/Wood Grain/White Wood 8'0 "Impact" Glazed Fiberglass Single Door utilizing the Grain/Rustic/Mahogany Series 0 Fiberglass Door WINDSERTT" an operational window insert - Outswing (X - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R6 II (p) Inst 15210.15.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.15 for Design Pressure Ratings, any FL15210 R6 AE (b) Eval 15210.15.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. Bac_ Next Contact Us :: 2601 Blair Stone Road. Tallahassee Fl- 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Befund Statement https://www.floridabuilding.org/pr/pr_app_dtl.aspx?paraxn=wGEVXQwtDgv3yVVKJZIQRCFPqu8gbCgpaL%2fcMd8xBvDdrXKxpoHIdA%3d%3d[811612018 3:25:IO PM] Florida Building Cpde Online Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: MM - FG-M-1 eClrecfc M Credit_ • Safe SCCLlritVi4M121CS' %3d%3d[8/16/2018 3:25:10 PM] ro plastp 5200 W. CENTURY BLVD. LOS ANGELES, CA 90045 Smooth / Wood Grain / White Wood Grain Rustic / Mahogany Series O Fiberglass Door INSWING / OUTSWING "IMPACT" GENERAL NOTES I. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as fisted and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used In the "HVHT' this product complies with Section 1626 of the Florida Building Code and does not require an impact resistant covering. 4. _ When used in areas outside of the "HVHZ" requiring wind bome debris protection, this product compiles with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an Impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 5. For 2x stud construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. 7. Outswing configurations meet water infiltration requirements for "HVHT'. All other configurations do not meet the water infiltration requirements for the "HVHT' and must be installed only in non -habitable areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sib is less than 45 dearees. TABLE OF CONTENTS SHEET# DESCRIPTION SHEET## I DESCRIP17ON 1 Typical Elevations, Design Pressures & General Notes 7 Horizontal & Vertical Cross Sections (Direct to Masonry) 2 Door Panel Details 8 3-point lock details 3 Horizontal & Vertical Cross Sections (2X Buck) 9 3-point lock details 4 Horizontal & Vertical Cross Sections (1 X Buck) 10 Buck and frame anchoring 5 Horizontal & Vertical Cross Sections (Direct to Masonry) 11 Components 6 Vertical Cross Sections (Thresholds) 12 Bill of materials 37,50" MAX. OVERALL FRAME WIDTH O z Z y z 0 O W 11J W KQL x O O 5 C`! CD - CONO3IMATION MAX !)Ih1ENSION:; DESIGN FRESSURE (FSF7.: FOSIiIVE NEGATIVE x 37.5" x 82.0" +75.0 -75.0 See sheets 2 for hardware design pressure limitations Z' rrs, n J_Z ro a RgiM \ 4) _ M Z O M O a N •• Z a 0 x N Em zmod ug 9p oa Ua mda(°i 0 cd oZ �( 3�'a N S22 CC pJ �� oz D_'V1 J Q"% It wy °I �aa scuE N.T.S. M. BY. JK � �BY. IFS FL-15210.1 IT L OF 122 R:\Olents\Plastpro, Inc PERNANENT\A - Florida Product Apprm als\FL-15210 HVHZ Flberglam - Impact Opaque and Glazed\C - Drawings\FL-15210 (2017)\FL-15210.1-6.dwg, 2.1 79.25' MAX. O.A. HBGHT N--', o ® O � 0 r x m ® ® ® b I S d m 38.19' D 1161 LOCK) A N m m r� T D m D Fn 0 0 = s F h 3 3 �0mn� oz momaZe 0 O O O O 0 O i� rn �' ym crew 'A A As y (pap�yy p a tiri fA as GG N rn i*n Q y GI mbm O 1+ I+ 7-1--i 0 D Iv CI T cq O Oo A I D v v n 1.75' C m yA O' 3 y � r NN $� �3 z=0 ``yyyzJJ m � Ne' •�• '. va r �O� IX ` No.43409 i f Q PRODUCT: Documents Prepared By. ' PLASTPRO INC. Lyndon F. Schmidt �j o N FIBERGLASS DOOR P.E. No. 43409 // '<♦� ^1 U) o Z ��/�III�iIL11��♦ r N ' ` H m 2 7 24 17 UPDATE TO 6TH ED. 2017 FBC JK PART OR ASSEMBLY: BUILDING .CONSULTANTS, INC. IN p 7R Vf 1 3 9 15 UPDATE TO 5TH ED. 2014 F8C JK DOOR PANEL DETAILS P.O. Box 230. Valrico, FL 33595 N NO DATE BY Phone No.: 813.659.9197 REVISIONS FBPE C.A. No. 9813 fd .......... r.... R:\(Vents\Plastpro, Inc PERMANENT\A - Fodda Product Approvals\FL-15210 HVHZ Fiberglass - Impact Opaque andGlazed\C- Drawings\FL-MI0 (2017)\FL-15210.1-6.dwg, 3.1 rn � A �z m p. OSO co to O a— y� 7n0 n 'rn Z � a �z O N Z X o WW • o. ZNVA VN b�N AN WN A.�W PW NW 22 0 a O a wn(o tn (o O r �n N r V pj A 3.n CD s_ _o W z ° a ° v z m Me W W I O yc0 T > ° 3.� v rD �r o v � O v z � m 70 c ° 0.15 C-SINK n r l02:11 (TYP) v.• eF . 1-1/4' MIN. EMB. (TYP.) Li �_ _ No.43409 9 G`r7��� * •E $ s PRODUCT: Document. Prepared By: %'.•• •�ZORIDR� �Q�`�� IW I E ? N FIB GLASS DOOR P. Schm E. No.ndon F434091dt Ie�''.0.�0'111 ; o BOO N y pr 2 7 24 17 UPDATE i'O 67H ED. 2017 FBC JK .PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. Ip N [q \ 1 3 9 15 UPDATE TO 5TH ED. 2014 FBC JK P.O. Box 230, Valrico, FL 33595 N N NO DATE BY HORIZONTAL & VERTICAL Phone No.: 813.659.9197 REVISIONS CROSS SECTIONS (2X BUCK) FBPE C.A. No. 9813 i R:\Olents\Plastpro, Inc PERMANENTW - Florida Product AppmVals\FL-15210 HVHZ FO:erglass - Impact Opaque and Glaxed\C- Drawings\FL-15210 (2017)\FL-15210.1-6.dwg, 4.1 6'I M d e < n < u d, G A •+ n m - �— c C O m ? n O X fl 5cr A., O T �• � V � .Aq N O Z 0 O I0 a 0 A N 01S v BOO N ��0 V OX s $ 3ff 9rn mA _ n n �"� a u ry 3 .. 0 O � v a �a < m M m m 22 p c D >a Os Q >, 93 n P' c 'P* �aO A C. V v o. a Z M O A N vv � �•SCNJy/� �'G 1-1/4'MIN. EMB. V ,•'v6ENe4; . �' �� (TYP.( L •} No. 43408 �1,,� 2 rT1• ? •� i PRODUCT: PLA57PRO INC. Daeumentn Prepared 9Y n Lyndon F. Schmidt �ii'�Si .�Ota01:X ����� •• o FIBERGLASS DOOR P.E. No. 43409 toso N ro r Z :4 rn 2 BUILDING CONSULTANTS, INC. 7 24 17 UPDATE 70 6TH ED. 2017 TUC PART OR ASSEMBLY: IN C) y C�j/��//� P.O. Box 230, Valrico, FL 33595 N CROSS 3ECi0NS (IXTBLICK) - - Phone No.: 813.659.9197 REVISIONS FBPE C.A. No. 9813 JK 1 3 9 15 UPDATE TO Shl ET). 2014 FBC JK NO DATE BY R:\Olents\Plast,pra, Inc PERMANENT\A - Flodda Product Approvals\FL-M10 HVHZ Fiberglass - impact Opaque and Glazed\C- Draw1ngs\FL-35210 (2017)\FL-15210.1-6.dwg, 5.1 T 0 0 A T m m m <" w O 0 o�n �O A prpo 0 5.� N roZ 3, Q o z m no O I EMB. (TYP.) �.. F•SCHIyjOj'/. 0 43409 IN r IN c to ;, N o - r— 2 y x (n N 2 1 N NO PRODUCT: PLASiPRO INC. FIBERGLASS DOOR 0oaumants Prepamd By: Lyndon F. Sehmldt•«+!?!:•''O�`� P.E. No. 43409 /// S���AL �`��� / /ff111111 (Q BUILDING CONSULTANTS, INC. t/Lcj�/ P.O. Box 230, Valrleo• FL 33595 I/U Phone No.: 813.659.9197 FBPE CA No. 9813 7 24 17 UPDATE TO 6TH ED. 2017 FBC JK PART OR ASSEMBLY: HORIZONTAL& VERTICAL CROSS SECTIONS DIRECT TO MASONRY) 3 9 15 UPDATE TO 5TH ED. 2014 FBC JK DATE BY REVISIONS 11 i R:%QentsXPlasIpm, Inc PERMANENT\A - Florida product Approvals\FL-15210 HVHZ Fiberglass - Impact Opaque and Glazed\C - Drawings\FL-15210 (2017)\FL-15210.1.6.dwg, 6.1 I Z m A M 0 n. O7y W o M n n n ° • c g.0 o N � e N O Z co � m 0 w `�11111111/Ill7j • No.43409 41- ay i PRODUCT: Doaumentn Prepo-d ey: � ��i ��Q�''• ram- PLASTPRO INC. FIBERGLASS DOOR Lyndon F. Sehmldt •.........• � P.E. No. 43409 cn ? z lllll N —. y aINO 7 24 17 UPDATE TO 6'TH ED. 2017 FBC JK PART OR ASSEMBLY: llllll\�\ CQ BUILDING CONSULTANTS, INC. 3 9 15 UPDATE TO 5TH ED. 2014 FBC JK'/L��% P.O. Box 230, valrieo, FL 33595 DATE BY SECTIEONSC(THRESHOLDS) '" Phone No.: 813.659.9197 REVISIONS FBPE CA No. 9813 R:\Clients\Plastpm, Inc PERMANENT\A - Flarida Product Approvals\FL-15230 HVHZ Fiberglass - Impact Opaque and Glazed\C - Drawings\FL-15210 (2017)\FL-15210.1.6.dwg, 7.1 ED �1 —+ � 3 v T Z MAX. 3 1.2s' II„o MIN. ?,i N o 0 fooQ ° n 7 n £O r o`er y pp 3 T V i!I m n Z 1-1/4" MIN. 0 EMB. (iYP.) VIJ A O �oO p to m o O o n A0. �00 �• Z zy �Z o T 1.2S' p• Q ` MIN. Z 2.25' 1.S' MAX. z o V W IS4 MAX. 00 O z v MIN. O W n Z o �a n 0�^ ° a� o`er Q F y 18 A n T � y Z Q Os m Z a .� 1-1/4"MIN. g t'o o a EMB. (TYP.) r 0 2R f; O Ha N ,Oy - o Or Z V A 0o O ;. 3 f) n c �o O IS T z MIN. `%FtSCF11yj��gG 3 n 3 L4.26' ISMAX.O zc / No.43409 z �P ��r c yt '• *r i PRODUCT: Document. Prepared Etr r ly PLASTPRO INC. Lyndon F. Schmidt �i�..tORIDR%",ap``��`` I� o Z \ FIBERGLASS DOOR P.E. No. 43409 yALt`��\`� N y 2 7 24 17 UPDATE TO 6TH ED. 2017 FBC JK PART OR ASSEMBLY: (,Q�7 BUILDING CONSULTANTS, INC. UPDATE TO 5TH ED. 2014 F13C JK IR 1/�� P.O. Box 230. Valrico, FL 33595 IN y m NO DATE BY HORIZO AL &VERTICAL vv Phone No.: 513.659.9197 REVISIONS SECTIONS DIRECT TO MASONRY) FBPE CA No. 9513 0 201 2 R.W. BUILDING COHaUL—NIre INC. _ R:\Olents\Plastpro, Inc PERMANENT\A - Rodda Product Approvals\FL-15210 HVHZ Rberglass - Impact Opaque and Glazed\C - Drawings\FL-1S210 (2017)\FL-15210.1-6.dwg, 8.1 i Z C OVERALL HEIGHT D rn HANDLE HEIGHT 1 --I O z va aB• o s m G) m D w M 10.04" —{ � I N W 3 - 4.63: N 3.63 0.11" x x O Q @ � � 3 o � 3v 11i O rD N O as � y �n 3 m s ® 0 ® y v s O m m C C ��j w m C C On oa y C w C � O m 3.61" H w F--15" pututgi W 43.09" G44 No. 43409 • i n 4I PRODUCT: Document• Lyndon Prepared By.own F. Schmidt ��4�• • •��•' ,e Z o PLASTPRO FIBERGLASS INC. DOOR P.E. No. 43409 Im iT oJt Z tJ y VI 2 1 7 24 i7 3 9 75 UPDATE TO 6TH ED. 2017 FBC UPDATE TO 5TH ED. 2014 FBC JK JK PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. �� Ip N :+ I. NO DATE BY 3-POINT LOCK DETAILS P.O. Box 230, Valrico, FL 33595 Phone No.: 813.659.9197 D 201 2 R.W. allILDINDI CDNSl1LT M INC IR:\Olents\Plastpro, Inc PERMANENT\A -Florida Product Appmals\FL-15210 HVHZ Fiberglas - Impact Opaque and Glazed\C - Drawings\FL-15210 (2017)\FL-15210.1.6.dwg, 9.1 Z C w� v � n0`z z zC c 3 ® o 0 Q Q O Q Y N N O X Z n n 6: cn tp a O N cn V P b O 24.26' 23.0 15.0" \\ptununi e. No. 43409 !-G.r $y i PRODUCT: Documerrte Prepared By: , 2 rJ __ PLASTPRO INC. Lyndon Schmidt % FiOH191\ (rj I� I FIBERGLASS DOOR P.E. No. 43409 N CA o Z �TI7111111t\, N -i Or PART OR ASSEMBLY: @�z�� BUILDING CONSULTANTS, INC. riu H 3-POINT LOCK DETAILS JLl/1/ P.O. Box 230, Valrico, FL 33595 N VV Phone No.: 813.659.9197 REVISIONS FT3PE C.A. No. 9813 2C12 R.W. Burtorwo Coneutrwrura Iwc- 2 7 24 17 UPDATE 70 6TH ED. 2017 FBC JK 1 3 9 15 UPDATE 70 5TH ED. 2014 FBC JK NO DATE BY 4" D TYP. HEAD &JAMBS MASONRY 71 OPENING 2X BUCK ;D U -- O BUCK ANCHORING CONCRETEANCHOR NOTES: 1. Concrete anchorlocations of the comers may be a*nfed to maintain the min. edge distance to mortarjoints. 2. Concrete anchorlocations noted as "MAX ON CENTER"must be adjusted to maintain the min. edge distance to modarjoints, additional concrete anchors may be required to ensure the MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table :.ANCHOR ANCHOR :;� MIN ' MIN CLEARANCE MIN!CLEARAN@E �'. TYPE -: SIZE 'EMBEDMENT: 70 MASONRY TOADJACENT . -: EDGE:.iANCHOR .` RY/ ® TAPCON 1 4" / 1-1/4" 2" 4" ELCO 1/4' 1-1/4' 1" 4" ULTRACON nw ® 3/16" 1.1/4- AS SHOWN 1.1/2" TAPCON 1. WOOD SCREW INSTALLATION NOTES: Maintain a minimum 5/8• edge distance, 1"end distance, & I"o.c. spacing of wood screws to prevent the splitting of wood. 49/16" JAMB P DIRECT TO MASONRY JAMB (TYP.) (SEE SHEET 7) (TYP-) SEE HINGE L 2X BUCK a DETAIL (TYP.)7 G 1X BUCK DIRECT TO D a MASONRY MASONRY OPENING TYP. HEAD & JAMBS FRAME ea U 49/16" JAMB fH 2X BUCK ^6-9/16" JAMB N a DIRECT TO MASONRY JAMB (TYP.) (SEE SHEET 71 ADA SILL ( ONLY STRIKE JAMB FRAME ANCHORING Masonry construction DIRECT TO DIRECTTO MASONRY M M MASONRY 28 IX BUCK G G I BUCK 2X BUCK L 2X BUCK 58 58 2X BUCK 1XBUCK 11 DIRECT TO M MASONRY 11 DIRECTTO 11 ❑ MASONRY G IX BUCK 27 58 2XBUCK LATCH d DEADBOLT DETAIL HINGE DETAIL Inswing niDcr•T Tn * J`%%,%%% ' �N d a y z •• : rz i�Y �ij �ofJ u of ro Q t 'fit Il1T �``` ZO n m a N •• z `oEo n O L o Z `\I Qt to 9moa cw o V �aN"a maa� e� c° z S 3'a z a 0 zo 0 often �.' 7e 0 I U IL a M) HINGE JAMB HINGE DETAIL Outswing LE: N.T.S. ,• Br. X BY. LFS WING NO.: FL_ 15210.1 Er Z oP 12 I R:\DlentAPlastpm, Inc PERMANENT\A - Florida Product Approvals\FL-15210 HVHZ Fiberglass - Impact Opaque and Glazed\C- Drawings\FL-15210 (2017)\FL-MI0.1-6.dwg, 11.1 N � � N m• � U x OoD. y — T r•2 5 0 0 6 0 —►i .25' ."� imlll I2 0. m - 6 � 98" V OwD .wa iH QH o0 00 s^ Gy cr NMI El a - O O 1.4" O 0 m O 3 2 7 24 17 UPDATE TO 6TH ED. 2017 FBC JK 1 3 9 15 UPDATE TO 5TH ED. 2014 FBC JK NO DATE BY SCFIM�' N0.43409 G -*7 PRODUCT: Doe umente Preporee By: PLASTPRO INC. FIBERGLASS DOOR Lyndon F. Schmidt P.E. No. 43409�ONA1-,--V BUILDING CONSULTANTS, INC. PART OR ASSEMBLY: ,/// R/I/ P.O. Box 230, Vclrico, FL 33595 COMPONENTS VY Phone No.: 813.659.9197 FBPE CA No. 9813 - T .....''''rrrn IU, V cx,. 4 Rd MI %%%%% o n m i U N •- d V (9 0 z - o U p J Ij m o LL a Na maa� �� d E oZ �d K O �o �m am 91 0 a H C J m 0 " J J o: m o zo o rn z N 1--o D° U U �m na N N 0o ww �� 00 n N N DAw- 02116112 = � N.T.S. ° M. at: JK m CHN. ar. LFS 3 DRAWW° NO.: ¢ FL-15210.1 " 0 SHEET 12 OF 12 " BILL OF MATERIALS REM Y DESCRIPDON MAII'RIAC A 1X8UCKSG>=0.55 WOOD B 2X BUCK SG >= 0.55 WOOD C 1 /4"MAX. SHIM SPACE - D 1 /4" X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE G 3/16" x 3-1/4"PFH ITW CONCRETE SCREW STEEL I 1/4" X 1-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL J 1/4" X 3�/4"PFH ELCO OR RVJ CONCRETE SCREW STEEL K 1 /4" X 2-1 /4" ITW CONCRETE SCREW STEEL L #10 X 2-1/7' PFH WOOD SCREW (1.15"MIN. EMBEDMENT) STEEL M 3/16" X 2-1/4" ITW CONCRETE SCREW STEEL N 3/16" X 2-3/4" ITW CONCRETE SCREW STEEL P 1/4" X 2-1/4"PFH ELCO CONCRETE SCREW STEEL 1 POLY FIBER JAMB COMP. /VINYL 2 FINGER JOINTED PINE FRAME WOOD 7 WEATHERSTRIP FOAM 8 DOOR BOTTOM SWEEP VINYL 9 4" X 4"BUTT HINGE STEEL 11 #9 X 3/4"PFH WOOD SCREW STEEL 22 3 POINT'TONGUE' MULTIPOINT LOCKSET (Mfg. BY HOPPED STEEL 23 MULTIPOINTSTRIKEPLATE(TONGUESYSTEM) STEEL 25 LATCH AND DEADBOLT STRIKE PLATE (TONGUE SYSTEM) STEEL 27 LATCH STRIKE PLATE STEEL 28 DEADBOLT STRIKE PLATE (SECURITY) STEEL 29 ADA THRESHOLD ALUM 30 OUTSWING THRESHOLD ALUM/WOOD 31 OUTSWING THRESHOLD ALUM/WOOD 32 OUTSWING THRESHOLD ALUM/WOOD 33 OUTSWING THRESHOLD ALUM/COMP 34 OUTSWING THRESHOLD ALUM/WOOD 36 INSWING THRESHOLD ALUM/COMP 37 INSWING THRESHOLD ALUM/WOOD 38 INSWING THRESHOLD ALUM/COMP 40 DOOR PANEL -SEE DOOR PANEL DETAIL SHEEP FOR CONSTRUCTION DETAILS 55 #10 X 1-1/2'"PFH SCREW STEEL 57 BACKING PLATE STEEL 58 #8 X 2"PFH WS STEEL 60 MULTIPOINT STRIKE PLATE STEEL 62 ENDURA TRILENNIUM 3000 LOCK ASSEMBLY STEEL