Wednesday, July 24, 2019
Richard McKuhen
Extreme Metal Fabricators
2160 SW Poma Drive
Palm City, FL 34490
Re: 7407 Ft. Walton Ave — Roof Installation
Mr. McKuhen,
FILECOPY
15211 97th Road N
West Palm Beach, FL 33412
Ph/Fx: (561) 225 —1982
lO - a 41�
RECEIVED
JUL 2 9 2019
ST. Lucie County, Permitting
I have reviewed the information you forwarded concerning installation of a metal roofing system over a
single layer of existing asphalt shingles on the above referenced project. The requirements for installation of metal
panel roofing systems are listed in Section 1507.4 of the 2017 Florida Building Code. Existing Roofing is covered
by Section 1511, with Section 1511.3 reading as follows:
1511.3 Recovering versus replacement.
New roof coverings shall not be installed without first removing all existing layers of roof
coverings down to the roof deck where any of the following conditions occur:
1.Where the existing roof or roof covering is water soaked or has deteriorated to the point
that the existing roof or roof covering is not adequate as a base for additional roofing.
2.Where the existing roof covering is wood shake, slate, clay, cement or asbestos -cement
tile.
3.Where the existing roof has two or more applications of any type of roof covering.
4.When blisters exist in any roofing, unless blisters are cut or scraped open and remaining
materials secured down before applying additional roofing.
5.Where the existing roof is to be used for attachment for a new roof system and
compliance with the securement provisions of Section 1504.1 cannot be met.
If the existing roof does not have any of the issues listed above, and if the panel system is installed per the
requirements of the its product approval and Section 1507.4, then installing your metal panel system over a single
layer of existing asphalt shingles is an acceptable application and will meet all the requirements of the 2017 Florida
Building Code.
If you have any questions or need more information please contact me.
Thankyou
IIlE.2.4 2f11c
l {�
(ZING IN IMPACT t?1�515TANT CUFTAINWALl.5, 5TOF�FPUN5, & WINPOW5
0
WOLTERS ENGINEERING
ENGINEERING, DRAFTING, CONSULTING
15211 971h Road N
West Palm Beach, FL 33412
Ph/Fx: (561) 225 —1982
Wednesday, July 24, 2019
Richard McKuhen
Extreme Metal Fabricators
2160 SW Poma Drive
Palm City, FL 34490
Re: 7407 Ft. Walton Ave — Roof Installation
Mr. McKuhen,
I have reviewed the information you forwarded concerning installation of a metal roofing system over a
single layer of existing asphalt shingles on the above referenced project. The requirements for installation of metal
panel roofing systems are listed in Section 1507.4 of the 2017 Florida Building Code. Existing Roofing is covered
by Section 1511, with Section 1511.3 reading as follows: -
1511.3 Recovering versus replacement.
New roof coverings shall not be installed without rust removing all existing layers of roof
coverings down to the roof deck where any of the following conditions occur:
I.Where the existing roof or roof covering is water soaked or has deteriorated to the point
that the existing roof or roof covering is not adequate as a base for additional roofing.
2. Where the existing roof covering is wood shake, slate, clay, cement or asbestos -cement
tile.
.).Where the existing roof has two or more applications of any type of roof covering.
4.When blisters exist in any roofing, unless blisters are cut or scraped open and remaining
materials secured down before applying additional roofing.
5.Where the existing roof is to be used for attachment for a new roof system and
compliance with the securement provisions of Section 1504.1 cannot be met.
If the existing roof does not have any of the issues listed above, and if the panel system is installed per the
requirements of the its product approval and Section 1507.4, then installing your metal panel system over a single
layer of existing asphalt shingles is an acceptable application and will meet all the requirements of the 2017 Florida
Building Code.
If you have any questions �odrdneed more information please contact me.
Thank you, `>>gj FENS'-.�s'fe
No 62354
Scott o ters
FL PE# 62354 > -� I¢./
®.1-% n ATM n= •L/a
MV I: I_71 IN Ir•;' ?,Cr
1�F748i1S1,•
W CIUKA M /4l. 7'0F'EFF,ON1" , & VVIN1!20`N5
EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
`26 GA. CLASSIC RIB PANEL'
FLORIDA BUILDING CODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 14645.9-R3
ROOFING
RECEIVES METAL ROOFING
J U N 2 4 2:01".9
ST. Lade Cou&V- PPriYtit iY1�
Prepared For:
Metal. Sales Manufacturing Corporation
545 South 3rd Street, Suite 200
Louisville, KY 40202
Telephone: (502) 855-4300
Fax: (502.) 855-4290
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida. Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (86.6) 366-1543
This report consists of
Evaluation Report (3 Pages including cover)
Installation Details (1 Page)
o®�tioe�aoe�s®°
�S0CKAL�N°°°i�
d
NO 62246
* : CC
off'.• STATE OF ; •Cu o
o FtAx boo
a
q.2o "7
File Copy
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
ROCC
Report No. C2182-9
Date: 9.9.17
• • FL 14645.9-R3
C2182-9
9.9.17
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: Classic Rib
Panel Description: 36" wide coverage with (5) 3/4" high ribs
Materials: Min. 26 ga., 80 ksi steel or min. 24 ga., 50 ksi steel. Galvanized coated
steel (ASTM A653) or Galvalume coated steel (ASTM A792) or
painted steel (ASTM A755).
Deck Description: Min. 19/32" thick plywood or min. 3/4" thick wood plank (min SG of
0.42) for new and existing constructions. Designed by others and
installed as per FBC 2017.
Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c.
(Minimum) in the field and edges. Designed as per FBC 2017.
Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1.
Substrate (optional): Min 1" x 4" No. 2 SYP wood purlins over min. 19/32" thick plywood
deck fastened to supports at maximum 24" o.c. Wood purlins shall be
fastened to wood rafters with (2) #9 x 3" long wood screws. The wood
purlins will be spaced same as panel fastener spacing along panel
length. The wood purlin, purlin to the rafter connection and rafters
must be designed by others to the carry the load imposed on the panels
and installed as per FBC 2017.
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2.
Requires applied lap sealant for roof slopes less than 3:12.
Design Uplift Pressure: 74.8 psf @ fastener spacing of 36" o.c.
(Factor of Safety = 2) 92.3 psf @ fastener spacing of 24" o.c.
133.9 psf @ fastener spacing of 18" o.c.
Fastener Pattern:
Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum
of 3/8".
At panel ends @ 3.5"-5.5"-3.5" o.c. across panel width
At intermediate @ 9" o.c. across panel width with two fasteners at each sidelap.
Sidelap Attachment: '/4"-14 x 7/8" long SDS with washer @ 12" o.c. Recommended for
(Optional) roof slope less than 3:12.
Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard
Requirements for Metal Roofing Systems'.
• ® FL 14645.9-R3
C2182-9
9.9.17
Page 3 of 3
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2017 Section 1505 and current
approved roofing materials directory or ASTM E108/UL790 report
from an accredited laboratory for fire ratings of this product.
Supporting Documents: TAS 125 Test Reports
Farabaugh Engineering and Testing Inc.
Project No. T193-05, Reporting Date 9/12/05
Project No. T240-07, Reporting Date 7/12/07
PANEL FASTENER SPACING 1/4"-14 X 7/8" TEK SCREW
SEE DETAIL 1 9 (NP) PER ALLOWABLE PRESSURE SPACED AT (OPTIONAL) 12" O.C.
CLASSIC RIB / THIS SHEET CLASSIC RIB TABLE ON THIS SHEET
MINIMUM ATTACHMENT: PLYWOOD
8d x 2.5" LONG RING SHANK NAIL 19/32" THICK (MIN.)
UNDERLAYMENT SHALL BE INSTALLED
AS PER MANUFACTURERS INSTALLATION
n
CLASSIC RIB
MIN. 2X_ WOOD RAFTER/JOIST/ IaUIULLII)ItJ
TRUSS AT MAX. 24" O.C.
/ SEE DETAIL 7
` THIS SHEET
SPACED ® 6" O.C. IN THE FIELD &
AT PLYWOOD EDGES
FASTENER PATTERN AT INTERMEDIATE LOCATIONS
36"
1/4"-14 X 7/8" TEK SCREW
SPACED AT 12" O.C.
(OPTIONAL)
\
UNDERLAYMENT SHALL BE INSTALLED
AS PER MANUFACTURERS INSTALLATION
11
PLYWOOD
MINIMUM ATTACHMENT: 19/32" THICK (MIN.)
QA ., o a" I Mir_ CIMr cWAMW Mnu
x
UUIULUNLJ OR 8 x 2" LONG WOOD SCREWS
\—MIN. 2X_ WOOD RAFTER/JOIST/
TRUSS AT MAX. 24" O.C. SPACED ® 6" O.C. IN THE FIELD &
AT PLYWOOD EDGES
FASTENER PATTERN AT PANEL ENDS
TYPICAL PANEL INSTALLATION X—SECTION
1 3/4" ---�— 1 3/4"
1/4"-14 X 7/8" TEK SCREW
SPACED AT 12 O.C.
(OPTIONAL) #9-16 OR #10-14 WOODSCREWS
WITH SELF SEALING WASHER AT
MAXIMUM SPACING OF 36" O.C.
CLASSIC RIB
MIN 26 GA.
ALLOWABLE UPLIFT PRESSURE
FASTENER
SPACING
(IN)
PRESSURE
(PSF)
36
74.8
24
92.3
18
133.9
GENERAL NOTES
QE
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE (FBC).
2. ROOF PANELS SHALL BE MIN. 26 GA. (t - 0.0181'. EFFECTIVE COVERING
WIDTH OF PANEL 36".
PLYWOOD 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
NT SPECIFIED ON THIS DRAWING.
19/32" THICK (MIN.) 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING.
ETAI L I 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
1
REQUIREMENTS OF THIS DRAWING & THE CODE. THE CODE SHALL CONTROL
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.