HomeMy WebLinkAboutENERGY EFFICIENCY CODE - 2I J
RECEIVED
FORM R405- 017
FLORID EN GY2EFFIC ENCY CODE FOR BUILDING CONSTRUCTION
Florida c ar r�ner�, , �4 iggs nd Professional Regulation - Residential Performance Method
Project
Name: TUBITO RESIDENCE Builder Name:
Street:
OLEANDER AVENUE Permit Office: ST LUCIE COUNTY
City, State,
Zip: FORT PIERCE, FL, Permit Number:
Owner:
NICK TUBITO Jurisdiction: ST LUCIE COUNTY
Design
Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (3932.7 sqft.) Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior R=4.1 3622.70 ft2
b. Frame - Wood, Adjacent R=11.0 310.00 ft2
3. Number of units, if multiple family 1
c. N/A R= ft2
4. Number of Bedrooms 3
d. N/A R= ft2
5. Is this is worst case? No
10. Ceiling Types (3677.0 sqft.) Insulation Area
a. Roof Deck (Unvented) R=20.0 3677.00 ft2
6. Conditioned floor area above grade (ft2) 3677
b. N/A R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A R= ft2
11. Ducts R ft2
7. Windows(670.7 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic 6 140
a. U-Factor: Sgl, U=0.70 390.67 ft2
b. Sup: Attic, Ret: Attic, AH: Attic 6 175
SHGC: SHGC=0.30
b. U-Factor: Sgl, U=0.65 280.00 ft2
12. Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit 24.0 SEER:16.00
c. U-Factor: N/A ft2
b. Central Unit 42.0 SEER:16.00 .
SH
13. Heating systems kBtu/hr Efficiency
i
d. U-Factor: N/A ft2
a. Electric Strip Heat 17.0 COP:1.00
SHGC:
b. Electric Strip Heat 27.0 COP:1.00
Area Weighted Average Overhang Depth: 6.528 ft.
Area Weighted Average SHGC: 0.279
14. Hot water systems
8. Floor Types (3677.0 sqft.) Insulation Area
a. Electric Cap: 40 gallons
a. Slab lOn-Grade Edge Insulation R=0.0 3677.00 ft2
EF: 0.980
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits None
Glass/Floor
Total Proposed Modified Loads: 120.85 PASS
Area: 0.182
Total Baseline Loads: 121.15
I hereby
certify that the plans and specifications covered by
Review of the plans and tiT E S7,
this calculation
are in compliance with the Florida Energy
specifications covered by this>��
Code.
calculation indicates compliance
the Florida Energy Code. -:;:�'•�. ;�
with !n�rr<'%-0
.,C.
PREPARraD
DATE:
Before construction is completed
this building will be inspected for "I'� C
11
compliance with Section 553.908ill
I hereby certify that this building, as designed, is in compliance
Florida Statutes. S
with the Florida Energy Code.
'C+01�.W6�.•
j
OWNER/AGENT
BUILDING OFFICIAL:
DATE: II 4DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FILE COPY
7/25/2018 11:22 AM EnergyGauge® USA Section R405.4.1 Compliant Software
Page 1 of 8
FORMi R405-2017 INPU 1 5UMMAKY GIitGKLIb I KtPUK 1
PROJECT
TitleI
TUBITO RESIDENCE
Bedrooms: 3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 3677
Lot #
Owner Name:
NICK TUBITO
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
OLEANDER AVENUE
Peralit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FORT PIERCE,
FamilIyType:
Single-family
FL,
New/E)asting:
New (From Plans)
Comment:
�I
CLIMATE
1
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
I
AHU 1
1319
14369.2
2 1
AHU2
2358
26855.2
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
BONUS ROOM
317
4438 No
0
1
Yes
Yes
Yes
2 I
BATH 2
66
660 No
0
1
Yes
Yes
Yes
I
3
BEDROOM 2
188
1880 No
0
1
1
Yes
Yes
Yes
4
BATH 3
84
840 No
0
1
Yes
Yes
Yes
5 l
WIC 2
32
320 No
0
1
No
Yes
Yes
6
WIC 3
42
420 No
0
1
No
Yes
Yes
7 I
HALL
66
660 No
0
1
Yes
Yes
Yes
8
I
BUTLER PANTRY
54
540 No
0
1
No
Yes
Yes
9
HALLWAY
79
790 No
0
1
No
Yes
Yes
i
10
BEDROOM 3
169
1690 No
0
1
1
Yes
Yes
Yes
11
SAFE ROOM
222
2131.2 No
0
1
Yes
Yes
Yes
12
LAUNDRY
120
1200 No
0
1
Yes
Yes
Yes
13
PANTRY
90
900 No
0
1
No
Yes
Yes
14
KITCHEN
285
3249 Yes
0
1
No
Yes
Yes
15
GREAT ROOM
528
6547.2 No
0
1
Yes
Yes
Yes
16
FOYER
99
1287 No
0
1
Yes
Yes
Yes
17
STUDY
208
2496 No
0
1
Yes
Yes
Yes
18 1
MASTER BEDROO
320
3520 No
0
1
1
Yes
Yes
Yes
19
i
M HALL
28
280 No
0
1
No
Yes
Yes
20 I
M BATH
196
1960 No
0
1
Yes
Yes
Yes
21
M W IC 2
56
560 No
0
1
No
Yes
Yes
7/26/201811:22 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 8
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
SPACES
Number Name Area Volume
Kitchen
Occupants
Bedrooms
InfilID Finished
Cooled
Heated
22,
M W IC 1
160 1600
No
0
1 Yes
Yes
Yes
23I
M TOILET 28 280
No
0
1 Yes
Yes
Yes
241
NOOK 240 2976
No
0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value Tile
Wood
Carpet
II
1 Slab -On -Grade Edge Insulation
BONUS ROOM
53 ft
0
317 ft2
---- 1
0
0
I
2 Slab -On -Grade Edge Insulation
BATH 2
6 ft
0
66 ft2
1
0
0
I
3 Slab -On -Grade Edge Insulation
BEDROOM 2
11.9 ft
0
188 ft2
__-- 1
0
0
I
4 Slab -On -Grade Edge Insulation
BATH 3
8 ft
0
84 ft2
1
0
0
i
5 Slab -On -Grade Edge Insulation
WIC 2
1 ft
0
32 ft2
-__- 1
0
0
6 Slab -On -Grade Edge Insulation
WIC 3
1 ft
0
42 ft2
1
0
0
I
I
7 Slab -On -Grade Edge Insulation
HALL
6.3 ft
0
66 ft2
____ 1
0
0
8 Slab -On -Grade Edge Insulation
BUTLER PANTR
1 ft
0
54 ft2
---_ 1
0
0
I
9 Slab -On -Grade Edge Insulation
HALLWAY
1 ft
0
79 ft2
-___ 1
0
0
10SIab-On-Grade Edge Insulation
i
BEDROOM 3
13 ft
0
169 ft2
1
0
0
I
11SIab-On-Grade Edge Insulation
I
SAFE ROOM
23 ft
0
222 ft2
__d 1
0
0
12SIab-On-Grade Edge Insulation
LAUNDRY
14 ft
0
120 ft2
___- 1
0
0
I
13SIab-On-Grade Edge Insulation
PANTRY
1 ft
0
90 ft2
---_ 1
0
0
I
14SIab-On-Grade Edge Insulation
I
KITCHEN
1 ft
0
285 ft2
__-_ 1
0
0
15SIab-On-Grade Edge Insulation
GREAT ROOM
22 ft
0
528 ft2
___- 1
0
0
I
16SIab-On-Grade Edge Insulation
FOYER
9 ft
0
99 ft2
__-_ 1
0
0
II 17SIab-On-Grade Edge Insulation
STUDY
26 ft
0
208 ft2
1
0
0
18SIab-On-Grade Edge Insulation
MASTER BEDRO
56 ft
0
320 ft2
---_ 1
0
0
19SIab-On-Grade Edge Insulation
M HALL
1 ft
0
28 ft2
1
0
0
i
20SIab-On-Grade Edge Insulation
M BATH
14 ft
0
196 ft2
--_- 1
0
0
21SIab-On-Grade Edge Insulation
M W IC 2
1 ft
0
56 ft2
__-- 1
0
0
22SIab-On-Grade Edge Insulation
I
M W IC 1
23 ft
0
160 ft2
____ 1
0
0
I23SIab-On-Grade Edge Insulation
M TOILET
11 ft
0
28 ft2
-___ 1
0
0
124SIab-On-Grade Edge Insulation
NOOK
22 ft
0
240 ft2
1
0
0
7/25/2018 II11.22 AM
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 3 of 8
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
ROOF
Roof
Gable
Roof Solar
SA
Emitt Emitt
Deck
Pitch
V #
Type
Materials Area
Area
Color Absor. Tested Tested
Insul.
(deg)
1
I
Hip Composition shingles 4112 ft2
0 ft2 Medium 0.6
No
0.9 No
20
26.6
ATTIC
V I #
Type
Ventilation
Vent Ratio in)
Area
RBS
IRCC
(1
1
I
Full attic
Unvented
0
3677 ft2
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented)
BONUS ROOM
20
Blown
317 ft2
0.1
Wood
1 2
Under Attic (Unvented)
BATH 2
20
Blown
66 ft2
0.1
Wood
3
Under Attic (Unvented)
BEDROOM 2
20
Blown
188 ft2
0.1
Wood
4
Under Attic (Unvented)
BATH 3
20
Blown
84 ft2
0.1
Wood
5
Under Attic (Unvented)
WIC 2
20
Blown
32 ftz
0.1
Wood
6
Under Attic (Unvented)
WIC 3
20
Blown
42 ft2
0.1
Wood
7
Under Attic (U nvented)
HALL
20
Blown
66ft2
0.1
Wood
8
Under Attic (Unvented)
BUTLER PANTR
20
Blown
54 ft2
0.1
Wood
9
Under Attic (Unvented)
HALLWAY
20
Blown
79 ft2
0.1
Wood
10
Under Attic (Unvented)
BEDROOM 3
20
Blown
169 ftz
0.1
Wood
it 11
Under Attic (Unvented)
SAFE ROOM
20
Blown
222 ft2
0.1
Wood
12
Under Attic (Unvented)
LAUNDRY
20
Blown
120 ft2
0.1
Wood
13
Under Attic (Unvented)
PANTRY
20
Blown
90 ft2
0.1
Wood
14
Under Attic (Unvented)
KITCHEN
20
Blown
285 ft2
0.1
Wood
15
Under Attic (Unvented)
GREAT ROOM
20
Blown
528 ft2
0.1
Wood
16
Under Attic (Unvented)
FOYER
20
Blown
99 ft2
0.1
Wood
17
Under Attic (Unvented)
STUDY
20
Blown
208 ft2
0.1
Wood
18
Under Attic (Unvented)
MASTER BEDRO
20
Blown
320 ftz
0.1
Wood
19
Under Attic (Unvented)
M HALL
20
Blown
28 ftz
0.1
Wood
20
Under Attic (Unvented)
M BATH
20
Blown
196 ftz
0.1
Wood
21
Under Attic (Unvented)
M WIC 2
20
Blown
56 ft2
0.1
Wood
22
Under Attic (Unvented)
M WIC 1
20
Blown
160ft2
0.1
Wood
1 23
Under Attic (Unvented)
M TOILET
20
Blown
28 ftz
0.1
Wood
24
Under Attic (Unvented)
NOOK
20
Blown
240 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Space
Height
Sheathing Framing
Solar
Below
1 N
Exterior Concrete Block - Ext InsdHONUS ROO
4.1 20
0 14 0
280.0 ftz
0 0
0.6
0
2 S
Exterior Concrete Block - Ext Ins(RONUS ROO
4.1 16
0 14 0
224.0 ft2
0 0
0.6
0
3 I W
Exterior Concrete Block - Ext lns8ONUS ROO
4.1 17
0 14 0
238.0 ftz
0 0
0.6
0
4 N
Exterior Concrete Block - Ext Insul BATH 2
4.1 6
0 10 0
60.0 ft2
0 0
0.6
0
5 1 N
Exterior Concrete Block - Ext InstBEDROOM 2
4.1 12
0 10 0
120.0 ft2
0 0
0.6
0
1
7/25/2018 11:22 AM
I
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 4 of 8
FORM, R405-2017
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
nrat
In
Space
1AIP11 Type_
_
_ 6
N
Exterior
Concrete Block - Ext Insul BATH 3
4.1
6
0
10
0
60.0 ft2
0
0
0.6
0
I
1
E
Exterior
Concrete Block - Ext Insul BATH 3
4.1
1
0
10
0
10.0 ft2
0
0
0.6
0
8
W
Exterior
Concrete Block - Ext Insul BATH 3
4.1
1
0
10
0
10.0 ft2
0
0
0.6
0
9
SW
Exterior
Concrete Block- Ext Insul HALL
4.1
6
5
10
0
64.2 ft2
0
0
0.6
0
1P
N
Exterior
Concrete Block - Ext InsMEDROOM 3
4.1
13
0
10
0
130.0 ft2
0
0
0.6
0
_ 1 jl
N
Exterior
Concrete Block - Ext InstSAFE ROOM
4.1
15
0
9
6
142.5 ft2
0
0
0.6
0
i
12
I
E
Exterior
Concrete Block - Ext Inst8AFE ROOM
4.1
4
0
9
6
38.0 ft2
0
0
0.6
0
_ 13
W
Exterior
Concrete Block - Ext InstSAFE ROOM
4.1
3
10
10
0
38.3 ft2
0
0
0.6
0
_ 14
E
Exterior
Concrete Block - Ext InsuILAUNDRY
4.1
11
0
10
0
110.0 ft2
0
0
0.6
0
15
S
Exterior
Concrete Block - Ext InsuILAUNDRY
4.1
3
0
10
0
30.0 ft2
0
0
0.6
0
16
W
Exterior
Concrete Block - Ext InsLQREAT ROO
4.1
22
0
12
4
271.3 ft2
0
0
0.6
0
17
E
Exterior
Concrete Block - Ext Insul FOYER
4.1
9
0
13
0
117.0 ft2
0
0
0.6
0
18I
N
Exterior
Concrete Block - Ext Insul STUDY
4.1
5
0
12
0
60.0 ft2
0
0
0.6
0
_ 19
E
Exterior
Concrete Block - Ext Insul STUDY
4.1
13
0
12
0
156.0 ft2
0
0
0.6
0
20I
S
Exterior
Concrete Block - Ext Insul STUDY
4.1
8
0
12
0
96.0 ft2
0
0
0.6
0
21
N
Exterior
Concrete Block - Ext InstMASTER BE
4.1
20
0
11
0
220.0 ft2
0
0
0.6
0
22
S
Exterior
Concrete Block - Ext InsLK1ASTER BE
4.1
20
0
11
0
220.0 ft2
0
0
0.6
0
23
W
Exterior
Concrete Block - Ext InsLKIASTER BE
4.1
16
0
11
0
176.0 ft2
0
0
0.6
0
24
S
Exterior
Concrete Block - Ext Insul M BATH
4.1
14
0
10
0
140.0 ft2
0
0
0.6
0
25
E
Exterior
Concrete Block - Ext Insul M WIC 1
4.1
12
0
10
0
120.0 ft2
0
0
0.6
0
26
S
Exterior
Concrete Block - Ext Insul M W IC 1
4.1
11
0
10
0
110.0 ft2
0
0
0.6
0
27
E
Exterior
Concrete Block - Ext InsulM TOILET
4.1
4
0
10
0
40.0 ft2
0
0
0.6
0
28
S
Exterior
Concrete Block - Ext InsulM TOILET
4.1
7
0
10
0
70.0 ft2
0
0
0.6
0
29
S
Exterior
Concrete Block - Ext Insul NOOK
4.1
9
0
12
4
111.0 ft2
0
0
0.6
0
_ 30
W
Exterior
Concrete Block- Ext Insul NOOK
4.1
13
0
12
4
160.3 ft2
0
0
0.6
0
31
E
Garage
Frame - Wood SAFE ROOM
11
27
10
270.0 ft2
0
0.25 0.600000
0
32
S
Garage
Frame - Wood SAFE ROOM
11
4
10
40.0 ft2
0
0.25 0.600000
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1
Metal Low-E Single Yes
0.65
0.25
N
18.0 ft2
1 ft 6 in
1 ft 4 in
None
None
2
W 3
Metal Low-E Single Yes
0.65
0.25
N
24.0 ft2
1 ft 6 in
1 ft 4 in
None
None
3
W 3
Metal Low-E Single Yes
0.65
0.25
N
30.0 ft2
1 ft 6 in
1 ft 4 in
None
None
4
N 4
Metal Low-E Single Yes
0.65
0.25
N
8.0 ft2
1 ft 6 in
1 ft 4 in
None
None
15
N 5
Metal Low-E Single Yes
0.65
0.25
N
18.0 ft2
1 ft 6 in
1 ft 4 in
None
None
N 6
Metal Low-E Single Yes
0.65
0.25
N
8.0 ft2
1 ft 6 in
1 ft 4 in
None
None
L6
SW 9
Metal Low-E Single Yes
0.7
0.3
N
21.3 ft2
1 ft 6 in
1 ft 4 in
None
None
8
N 10
Metal Low-E Single Yes
0.65
0.25
N
18.0 ft2
1 ft 6 in
1 ft 4 in
None
None
9
E 14
Metal Low-E Single Yes
0.65
0.25
N
12.0 ft2
1 ft 6 in
1 ft 4 in
None
None
10
W 16
Metal Low-E Single Yes
0.7
0.3
N
120.0 ft2
14 ft 0 in
1 ft 4 in
None
None
1I1
E 17
Metal Low-E Single Yes
0.65
0.25
N
18.0 ft2
1 ft 6 in
1 ft 4 in
None
None
12
E 17
Metal Low-E Single Yes
0.7
0.3
N
48.0 ft2
1 ft 6 in
1 ft 4 in
None
None
1
7/25/201811:22 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 8
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V #
Ornt ID Frame
Panes
NFRC
U-Factor SHGC Imp
Area Depth Separation
Int Shade
Screening
13
E 19 Metal
Low-E Single
Yes
0.66 0.25 N
12.0 ft2 1 ft 6 in 1 ft 4 in
None
None
14
E 19 Metal
Low-E Single
Yes
0.65 0.25 N
12.0 ft2 0 ft 0 in 0 ft 0 in
None
None
15
E 19 Metal
Low-E Single
Yes
0.65 0.25 N
24.0 ft2 1 ft 6 in 1 ft 4 in
None
None
16
N 21 Metal
Low-E Single
Yes
0.7 0.3 N
21.3 ft2 1 ft 6 in 1 ft 4 in
None
None
17
W 23 Metal
Low-E Single
Yes
0.65 0.25 N
24.0 ft2 1 ft 6 in 1 ft 4 in
None
None
1 18
W 23 Metal
Low-E Single
Yes
0.65 0.25 N
30.0 ft2 1 ft 6 in 1 ft 4 in
None
None
19
S 24 Metal
Low-E Single
Yes
0.65 0.25 N
10.0 ft2 1 ft 6 in 1 ft 4 in
None
None
20
E 25 Metal
Low-E Single
Yes
0.65 0.25 N
6.0 ft2 1 ft 6 in 1 ft 4 in
None
None
21
S 28 Metal
Low-E Single
Yes
0.65 0.25 N
8.0 ft2 1 ft 6 in 1 ft 4 in
None
None
22
S 29 Metal
Low-E Single
Yes
0.7 0.3 N
90.0 ft2 12 ft 0 in 1 ft 4 in
None
None
23
I
W 30 Metal
Low-E Single
Yes
0.7 0.3 N
90.0 ft2 12 ft 0 in 1 ft 4 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1
864 ft2
864 ft2
31 ft
loft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 W iolehouse ProposedACH(50)
.000499
4809.5 264.04 496.56 .3998
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric,Strip Heat/
None
COP:1
17 kBtu/hr
1
sys#1
2
Electric Strip Heat/
None
CORI
27 kBtu/hr
2
sys#2
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow
SHR Block
Ducts
i
1
Central Unit/
Split
SEER: 16
24 kBtu/hr 720 cfm
0.8 1
sys#1
2
Central Unit/
Split
SEER: 16
42 kBtu/hr 1260 cfm
0.8 2
sys#2
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap
Use SetPnt
Conservation
1
Electric
None
Garage
0.98 40 gal 60.9
gal 120 deg
None
7/25/2018 11:22 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 8
FORM R40.5-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
-71
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model # Area
Volume
FEF
I
None
None
ft2
DUCTS
— Supply—
— Return
--
Air
CFM 25
CFM25
HVAC #
V
#
Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN RLF
Heat Cool
1
Attic
6
140 ft2
Attic
14 ft2
Default Leakage
Attic
(Default) c(Default) c
1 1
2
Attic
6
175 ft2
Attic
18 ft2
Default Leakage
Attic
(Default) c(Default) c
2 2
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Coolini [ j Jan
[
Feb
Mar
Apr
May
Jun Jul
X] Au
[X] Se
Oct
Nov
j Dec
HeatinJan
Feb
Mar
f
Apr f
May 4
Jun f Jul
f ] Au[
] Sep
f Oct
Nov
f X] Dec
Venting[ ]Jan
Feb
Mar
[X]
Apr [
May [
Jun [ Jul
[ ] Aug
[ ] Se
[X] Oct
Nov
[ ]Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling II WD)
AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
80
80
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78 78
78
78
80
80
80
80
I(WD)
PM
80
80
80
80
78 78
78
78
78
78
78
78
Heating
AM
65
65
65
65
65 65
65
68
68
68
68
68
I.
PM
68
68
68
68
68 68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65 65
65
68
68
68
68
68
1
PM
68
68
68
68
68 68
68
68
68
68
68
68
I
7/25/2018 11:22 AM
I
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 7 of 8
R4O5-2017 INPUT SUMMARY CHECKLIST
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
BONUS ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 3
Default(8 lbs/sq.ft.
ft2
ft
0.3
HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BUTLER PANTRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
SAFE ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
PANTRY
I, Default(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
GREAT ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
STUDY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 1
Default(8 Ibs/sq.ft,
ft2
ft
0.3
M TOILET
Default(8 Ibs/sa.ft.
ft2
ft
0.3
NOOK
Name:
i
Rating Compant:
I
i
7/25/2018 11:22 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 8 of 8
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project
Name: TUBITO RESIDENCE Builder Name:
Street:
OLEANDER AVENUE Permit Office: ST LUCIE COUNTY
City,
State, Zip: FORT PIERCE, FL, Permit Number:
U
Owner:
NICK TUBITO Jurisdiction: ST LUCIE COUNTY
=
lesign
Location: FL, Fort Pierce
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERI
Gen
ral
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Celli
g/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Wall
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and floors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
FloorIs
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crav l space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narr w cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
i
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring an
J
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wirin .
Shovyer/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on e�tenor wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
CI. III a UIIIUII, IIIJF/CGl1Ul
7/25/2018 11:22 AM
ui iug wads snau oe in accordance with the provisions of icc-4uu.
EnergyGauge® USA FBC 6th Edition (2017) Compliant Software