Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEIRFORM R405-2017FLORIDA EN CODE FOR BUILDING CONSTRUCTION - � Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: TUBITO RESIDENCE Builder Name: SCAlftgo Street: OLEANDER AVENUE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: �g 07er: NICK TUBITO Jurisdiction: ST LUCIE COUNTY Lucie (�®�� Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or e)dsting New (From Plans) 9. Wall Types (3932.7 sgft.) Insulation Area I 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 3622.70 ft2 b. Frame - Wood, Adjacent R=11.0 310.00 W 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (3677.0 sgft.) Insulation. Area 5. Is this a worst case? No a. Roof Deck (Unvented). R=20.0 3677.00 ft2 6. Coiditioned floor area above grade (ft2) 3677 b. N/A R= ft2 Coiditioned floor area below grade (ft2) 0 c. N/A R= 2 11. Ducts f R ft2 7. Windows (670.7 scift.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 140 a. 6-Factor: Sgl, U=0.70 390.67 ft2 b, Sup: Attic, Ret: Attic, AH: Attic 6 175 SHGC: SHGC=0.30 b. U-Factor: Sgl, U=0.65 280.00 ft2 12. Cooling systems kBEfficiency SHGC: SHGC=0.25 a. Central Unit 24.0tu/hr 4.0 SEER:16.00 b. Central Unit 42.0 SEER:16.00 c. J-Factor: N/A ft2 LLSHGC: 13. Heating systems kBtu/hr Efficiency J d. l-Factor: N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: b. Electric -Strip Heat 27.0 COP:1.00 Arta Weighted Average Overhang Depth: 6.528 ft. Area Weighted Average SHGC: 0.279 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (3677.0 sgft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 3677.00 ft2 b. Conservation features b. N/A R= ft2 None c. /A R= ft2 15. Credits None Glass/Floor /Floor Area: 0.182 Total Proposed Modified Loads: 120.85 PASS Total Baseline Loads: 121.15 I hereby certify that the plans and specifications covered by Review of the plans and O�S14E S�,q?� this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance I with the Florida Energy Code. PREP D DATE: Before construction is completed this building will be inspected for a `" 11j, compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. COb"1�E' with Florida Energy Code. the ter. f OWNER/AGFNT: £_ BUILDING OFFICIAL: DATE: q " 13--i1 I DATE: an ipliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as ified factory -sealed in accordance with R403.3.2.1'. pliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires relope leakage test report with envelope leakage no greater than 7.00 ACH50 (111402.4.1.2). 8 11:22 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title) TUBITO RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 3677 Lot # Owner Name: NICK TUBITO Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: OLEANDER AVENUE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 I 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 1319 14369.2 2 AHU2 2358 26855.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BONUS ROOM 317 4438 No 0 1 Yes Yes Yes 2 BATH 2 66 660 No 0 1 Yes Yes Yes 3 BEDROOM 2 188 1880 No 0 1 1 Yes Yes Yes 4 BATH 3 84 840 No 0 1 Yes Yes Yes 5 WIC 2 32 320 No 0 1 No Yes Yes 6 WIC 3 42 420 No 0 1 No Yes Yes 7 HALL 66 660 No 0 1 Yes Yes Yes 8 BUTLER PANTRY 54 540 No 0 1 No Yes Yes 9 HALLWAY 79 790 No 0 1 No Yes Yes 10 BEDROOM 3 169 1690 No 0 1 1 Yes Yes Yes 11 SAFE ROOM 222 2131.2 No 0 1 Yes Yes Yes 12 LAUNDRY 120 1200 No 0 1 Yes Yes Yes 13 PANTRY 90 900 No 0 1 No Yes Yes 14 KITCHEN 285 3249 Yes 0 1 No Yes Yes 15 GREAT ROOM 528 6547.2 No 0 1 Yes Yes Yes 16 FOYER 99 1287 No 0 1 Yes Yes Yes 17 STUDY 208 2496 No 0 1 Yes Yes Yes 18 MASTER BEDROO 320 3520 No 0 1 1 Yes Yes Yes 19 M HALL 28 280 No 0 1 No Yes Yes 20 M BATH 196 1960 No 0 1 Yes Yes Yes 21 M WIC 2 56 560 No 0 1 No Yes Yes 7/25) 01811:22 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 8 • FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 M WIC 1 160 1600 No 0 1 Yes Yes Yes 23 M TOILET 28 280 No 0 1 .Yes Yes Yes 24, NOOK 240 2976 No 0 1 Yes Yes Yes ' FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BONUS ROOM 53 ft 0 317 ft2 1 0 0 2 Slab -On -Grade Edge Insulation BATH 2 6 ft 0 66 ft2 ___ 1 0 0 3 Slab -On -Grade Edge Insulation BEDROOM 2 11.9 ft 0 188 ft2 -1 0 0 4 Slab -On -Grade Edge Insulation BATH 3 8 ft 0 84 ft2 ____ 1 0 0 5 Slab -On -Grade Edge Insulation WIC 2 1 ft 0 32 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulation WIC 3 1 ft 0 42 ft2 __ 1 0 0 7 Slab -On -Grade Edge Insulation HALL 6.3 ft 0 66 ft2 __ 1 0 0 8 Slab -On -Grade Edge Insulation BUTLER PANTR 1 ft 0 54 ft2 __ 1 0 0 9 Slab -On -Grade Edge Insulation HALLWAY 1 ft 0 79 1112 ___ 1 0 0 10SIab-On-Grade Edge Insulation BEDROOM 3 13 ft 0 169 ft2 ____ 1 0 0 11SIab-On-Grade Edge Insulation SAFE ROOM 23 ft 0 222 ft2 ____ 1 0 0 I 12SIab-On-Grade Edge Insulation ' LAUNDRY 14 ft 0 120 ft2 ___ 1 0 0 13SIab-On-Grade Edge Insulation PANTRY 1 ft 10 90 ft2 1 0 0 14SIab-On-Grade Edge Insulation KITCHEN 1 ft 0 285 ft2 1 0 0 15SIab-On-Grade Edge Insulation GREAT ROOM 22 ft 0 528 ft2 1 0 0 16SIab-On-Grade Edge Insulation FOYER 9 ft 0 99 ft2 1 0 0 I 17SIab-On-Grade Edge Insulation ' STUDY 26 ft 0 208 ft2 ___ 1 0 0 18SIab-On-Grade Edge Insulation MASTER BEDRO 56 ft 0 320 ft2 ___ 1 0 0 19SIab-On-Grade Edge Insulation M HALL 1 ft 0 28 ft2 ___ 1 0 0 20SIab-On-Grade Edge Insulation M BATH 14 ft 0 196 ft2 1 0 0 21SIab-On-Grade Edge Insulation M W IC 2 1 ft 0 56 ft2 ___ 1 0 0 22SIab-On-Grade Edge Insulation M W IC 1 23 ft 0 160 ft2 ___ 1 0 0 23SIab-On-Grade Edge Insulation M TOILET lift 0 28 ft2 1 0 0 24SIab-On-Grade Edge Insulation NOOK 22 ft 0 240 ft2 1 0 0 I 7/25/2018 11:22 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 4112 ft2 0 ft2 Medium 0.6 No 0.9 No 20 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 3677 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) BONUS ROOM 20 Blown 317ft2 0.1 Wood 2 Under Attic (Unvented) BATH 2 20 Blown 66 ft2 0.1 Wood 3 Under Attic (Unvented) BEDROOM 2 20 Blown 188 ft2 0.1 Wood 1 4 Under Attic (Unvented) BATH 3 20 Blown 84 ft2 0.1 Wood 5 Under Attic (Unvented) WIC 2 20 Blown 32 ft2 0.1 Wood 6 Under Attic (Unvented) WIC 3 20 Blown 42 ft2 0.1 Wood 7 Under Attic (Unvented). HALL 20 Blown 66 ft2 0.1 Wood 8 Under Attic (Unvented) BUTLER PANTR 20 Blown* 54 ft2 0.1 Wood 9 Under Attic (Unvented) HALLWAY 20 Blown 79 ft2 0.1 Wood 1 10 Under Attic (Unvented) BEDROOM 3 20 Blown 169 ft2 0.1 Wood I 11 Under Attic (Unvented) SAFE ROOM 20 Blown 222 ft2 0.1 Wood 12 Under Attic (Unvented) LAUNDRY 20 Blown 120 ft2 0.1 Wood 13 Under Attic (Unvented) PANTRY 20 Blown go ft2 0.1 Wood 14 Under Attic (Unvented) KITCHEN 20 Blown 285 ft2 0.1 Wood 15 Under Attic (Unvented) GREAT ROOM 20 Blown 528 ft2 0.1 Wood 16 Under Attic (Unvented), FOYER 20 Blown 99ft2 0.1 Wood 17 Under Attic (Unvented) STUDY 20 Blown 208 ft2 0.1 Wood 18 Under Attic (Unvented) MASTER BEDRO 20 Blown 320 ft2 0.1 Wood 19 Under Attic (Unvented) M HALL 20 Blown 28 ft2 0.1 Wood 20 Under Attic (Unvented) M BATH 20 Blown 196 ft2 0.1 Wood 21 Under Attic (Unvented) M WIC 2 20 Blown 56ft2 0.1 Wood 22 Under Attic (Unvented) M W IC 1 20 Blown 160 ft2 0.1 Wood 23 Under Attic (Unvented) M TOILET 20 Blown 28 ft2 0.1 Wood 24 Under Attic (Unvented) NOOK 20 Blown 240 ft2 0.1 Wood WALLS Adjacent Cavity Width SpaceEt Height In ArpnR-1/ah Sheathing Framing le Solar Below _ 1 N Exterior Concrete Block - Ext Ins80NUS ROO 4.1 20 0 14 0 280.0 ft2 0 0 0.6 0 2 S Exterior Concrete Block - Ext InsiBONUS ROO 4.1 16 0 14 0 224.0 ft2 0 0 0.6 0 3 W Exterior Concrete Block - Ext InsfflONUS ROO 4.1 17 0 14 0 238.0 ft2 0 0 0A 0 4 N Exterior Concrete Block - Ext Insul BATH 2 4.1 6 d 10 0 60.0 ft2 0 0 0.6 0 5 N Exterior Concrete' Block - Ext InstBEDROOM 2 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 7/25/201811:22 AM EnergyGauge® USA Section R405.4.1 Compliant Software . Page 4 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing. Solar Below Space - - _ 6 N Exterior Concrete Block - Ext Insul BATH 3 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 7 E Exterior Concrete Block - Ext Insul BATH 3 4.1 1 0 10 0 10.6 ft. 0 0 0.6 0 8 W Exterior Concrete Block - Ext Insul BATH 3 . 4.1 1 0 10 0 10.0 ftz 0 0 0.6 0 911 SW Exterior Concrete Block - Ext Insul HALL 4.1 6 5 10 0 64.2 ft2 0 0 0.6 0 10; N Exterior Concrete Block - Ext Inse1EDROOM 3 4.1 13 0 10 0 130.0 ft2 0 '0 0.6 0 _ 11l N Exterior Concrete Block - Ext Inst4AFE ROOM 4.1 15 0 9 6 142.5 ft2 0 0 0.6 0 121 E Exterior Concrete Block - Ext InsiSAFE ROOM 4.1 4 0 9 6 38.0 ft2 0 0 0.6 0 13 W Exterior Concrete Block - Ext InstSAFE ROOM 4.1 3 10 10 0 38.3 f12 0 0 0.6 0 14 E Exterior. Concrete Block - Ext InsuILAUNDRY 4.1 11 0 10 0 110.0 ft2 0 0 0.6 0 15 S Exterior Concrete Block - Ext InsuILAUNDRY 4.1 3 0 10 0 30.0 1`12 0 0 0.6 0 161 W Exterior Concrete Block - Ext InsGREAT ROO 4.1 22 0 12 4 271.3 ft2 0- 0 0.6 0 17 E Exterior Concrete Block - Ext Insul FOYER 4.1 9 0 -13 0 117.0 ft2 0 0 0.6 0 18 N Exterior Concrete Block - Ext Insul STUDY 4.1 5 0 12 0 60.0 ft2 0 0 0.6 0 19 E Exterior Concrete Block- Ext Insul STUDY 4.1 13 0 12 0 166.0 ft2 0 0 0.6 0 20 S Exterior Concrete Block - Ext Insul STUDY 4.1 8 0 12 0 96.0 ft2 0 0 0.6 0 211 N Exterior Concrete Block - Ext InsdMASTER BE 4.1 20 0 11 0 220.0 ft2 0 0 0.6 0 _ 221 S Exterior Concrete Block - Ext InstWIASTER BE 4.1 20 0 11 0 220.0 ft2 0 0 0.6 0 23 W Exterior Concrete Block - Ext InsMASTER BE 4.1 16 0 11 0 176.0 ft2 0 0 0.6 0 24 S Exterior Concrete Block - Ext Insul M BATH 4.1 14 0 10 0 140.0. ft2 0 0 0.6 0 25 E Exterior Concrete Block - Ext Insul M WIC 1 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 26 S Exterior Concrete Block - Ext Insul M WIC 1 4.1 11 0 10 0 110.0 ft2 0 0 0.6 0 _ 27 E Exterior Concrete Block - Ext InsulM TOILET 4.1 4 0 10 0 40.0 ft2 0 0 0.6 U _ 28 S Exterior Concrete Block - Ext InsulM'TOILET 4.1 7 0 10 0 70.0 ft2 0 0 0.6 0 29 S Exterior Concrete Block -`Ext Insul NOOK 4.1 9 0 12 4 111.0 ft2 0 0 0.6 0 30 W Exterior Concrete Block - Ext Insul NOOK. 4.1 13 0 12 4 160.3 fF 0 0. 066 0 31 E Garage Frame - Wood SAFE ROOM 11 27 10 270.01ft2 0 0.25 0.60000*0 0 32 I S Garage Frame - Wood SAFE ROOM 11 4 10 40.0 ft2 0 0.25 0.600000 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang �/ # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening ilI N 1 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft2 1 ft 6 in 1 ft 4 in None None '2 W 3 Metal Low-E Single Yes 0.65 0.25 N 24.0 ft2 1 ft 6 in 1 ft 4 in None None 3 W 3 Metal N Low-E Single Yes 0.65 0.25 N 30.0 1t2 1 ft 6 in 1 ft 4 in None None 4 N 4 Metal Low-E Single Yes 0.65 0.25 N 8.0 f12 1 ft 6 in 1 ft 4 in None None 15 N 5 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft2 1 ft 6 in 1 ft 4 in None None I6 N 6 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft2 1 ft 6 in 1 ft 4 iri None None I 7 SW 9 Metal Low-E Single Yes 0.7 0.3 N 21.3 ft2 '1 ft 6 in 1 ft 4 in None None 9 N 10 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft2 1 ft 6 in 1 ft 4 in None None 9 E 14 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 1 ft 6 in 1 ft 4 in None None 10 W 16 Metal Low-E Single Yes •0.7 0.3 N 120.0 ft2 14 ft 0 in 1 ft 4 in None None 11 E 17 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft2 1 ft 6 in 1 ft 4 in None None 12 E 17 Metal Low-E Single Yes . 0.7 0.3 N 48.0 ft2 1 ft 6 in 1 ft 4 in None None 7/25/201a I1:22 AM EnergyGauge@ USA Section R405A.1 Compliant Software Page 5 of 8. i FORM R405-2017 INPUT SUMMARY CHECKLIST RFPORT WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang �/ # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 13 E 19 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 1 ft 6 in 1 ft 4 in None None 14 E 19 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 0 ft 0 in 0 ft 0 in None None 15 i E 19 Metal Low-E Single Yes 0.65 0.25 N 24.0 ft2 1 ft 6 in 1 ft 4 in None None 16 N 21 Metal Low-E Single Yes 0.7 0.3 N 21.3 ft2 1 ft 6 in 1 ft 4 in ' None None 17 W 23 Metal Low-E Single Yes 0.65 0.25 N 24.0 ft2 1 ft 6 in 1 ft 4 in None None 18 W 23 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 1 ft 6 in 1 ft 4 in None None 19 S 24 Metal Low-E Single Yes 0.65 0.25 N 10.Qft2 . 1 ft 6 in 1 ft 4 in None None 20 E 25 Metal Low-E Single Yes 0.65 0.25 N . 6.0 ft2 1.ft 6 in 1 ft 4 in None None 21 S 28 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft2 1 ft 6 in 1 ft 4 in None None 22 S 29 Metal Low-E Single Yes 0.7 0.3 N 90.0 ft2 12 ft 0 in 1 ft 4 in None None 23 W 30 Metal Low-E Single Yes 0.7 0.3 N 90.0 ft2 12 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 864 ft2 864 ft2 31 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000499 4809.5 264.04 496.56 .3998 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 17 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COPA 27 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts j 1 Central Unit/ Split SEER: 16 24 kBtu/hr 720 cfm 0.8 1 Sys#1 2 Central Unit/ Split SEER: 16 42 kBtu/hr 1260 cfm 0.8 2 sys#2 I HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 40 gal 60.9 gal 120 deg None 7/25/201811:22 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 8 i 1 • FORM R40R-9017 INPIIT _kIMAMAPV ('_141=f%KI ICT DGDnDT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply— — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 1 Attic 6 140 ft2 Attic 14 ft2 Default Leakage Attic (Default) c(Default) c 1 1 2 Attic 6 175 ft2 Attic 18 ft2 Default -Leakage Attic (Default) c(Default) c 2 2 i TEMPERATURES Progriamable Thermostat: N Ceiling Fans: CoolingJan HeatinJan Feb Feb Mar Mar f Apr Apr f May May Jun Jul Jun Jul Auge AuSep E Oct Oct Nov Nov Dec Dec Ventin Jan Feb Mar [Xj Apr [ May Jun Jul Aug Se (X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours SchedulIa Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling'(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 1 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 -68 68 68 i PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 I 7/25/2018 11:22 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 7 of 8 I FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT f MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 BONUS ROOM j Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 3 Default(81bs/sq.ft. ft2 ft 0.3 HALL �Default(8lbs/sq.ft. ft2 ft 0.3 BUTLER,PANTRY IDefault(8 lbs/sq.ft. ft2 ft 0.3 HALLWAY IDefault(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 IDefault(8 Ibs/sq.ft. ft2 ft 0.3 SAFE ROOM �Default(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft2 ft 0.3 PANTRY Default(81bs/sq.fL ft2 ft 0.3 KITCHEN befault(8lbs/sq.ft. ft2 ft 0.3 GREAT ROOM Default(81bs/sq.fL ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 STUDY i Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO IDIefault(8 Default(8 Ibs/sq.ft. ft2 ft 0.3 M HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH i Default(8lbs/sq.ft. ft2 ft 0.3 M WIC 2 Default(81bs/sq.ft. ft2 It 0.3 M WIC 1 Default(8 Ibs/sq.ft. ft2 It 0.3 M TOILET Default(8 Ibs/sq.fL ft2 ft 0.3 NOOK Name: Rating Compant: r -AZ %VV),`; ll f .. 7/25/201 1 11:22 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 8 of 8 I 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA I Project Name: TUBITO RESIDENCE Builder Name: Street: OLEANDER AVENUE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: NICK TUBITO Jurisdiction: ST LUCIE COUNTY W Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall . regwrements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceil I g/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction. of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (inclyding maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing,' or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. . Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or, unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narroty cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall'be provided between the garage and conditioned spaces. Recesed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall, be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an J plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind 061no and wirin . Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or, drywall. Concealed When required.to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler ; cover plates and walls or ceilings. U. If aaawon, II15pe0[IM OT log walls snarl be in accoroance Wim me provisions or iGG-4uu. 7/25/201811:22 AM EnergyGaugeO USA FBC 6th Edition (2017):Compliant Software Page 1 of 1