HomeMy WebLinkAboutENERGY EFFICIENCY CODEIRFORM R405-2017FLORIDA EN CODE FOR BUILDING CONSTRUCTION
- �
Florida Department of Business and Professional Regulation - Residential Performance Method
Project
Name: TUBITO RESIDENCE
Builder Name:
SCAlftgo
Street:
OLEANDER AVENUE
Permit Office: ST LUCIE COUNTY
City,
State, Zip: FORT PIERCE, FL,
Permit Number:
�g
07er:
NICK TUBITO
Jurisdiction: ST LUCIE COUNTY
Lucie (�®��
Design
Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or e)dsting New (From Plans)
9. Wall Types (3932.7 sgft.)
Insulation Area
I
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 3622.70 ft2
b. Frame - Wood, Adjacent
R=11.0 310.00 W
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (3677.0 sgft.)
Insulation. Area
5. Is this a worst case? No
a. Roof Deck (Unvented).
R=20.0 3677.00 ft2
6. Coiditioned floor area above grade (ft2) 3677
b. N/A
R= ft2
Coiditioned floor area below grade (ft2) 0
c. N/A
R= 2
11. Ducts
f
R ft2
7. Windows (670.7 scift.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 140
a. 6-Factor: Sgl, U=0.70 390.67 ft2
b, Sup: Attic, Ret: Attic, AH: Attic
6 175
SHGC: SHGC=0.30
b. U-Factor: Sgl, U=0.65 280.00 ft2
12. Cooling systems
kBEfficiency
SHGC: SHGC=0.25
a. Central Unit
24.0tu/hr
4.0 SEER:16.00
b. Central Unit
42.0 SEER:16.00
c. J-Factor: N/A ft2
LLSHGC:
13. Heating systems
kBtu/hr Efficiency
J d. l-Factor: N/A ft2
a. Electric Strip Heat
17.0 COP:1.00
SHGC:
b. Electric -Strip Heat
27.0 COP:1.00
Arta Weighted Average Overhang Depth: 6.528 ft.
Area Weighted Average SHGC: 0.279
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (3677.0 sgft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 3677.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. /A R= ft2
15. Credits
None
Glass/Floor /Floor Area: 0.182 Total Proposed Modified Loads: 120.85
PASS
Total Baseline Loads: 121.15
I hereby certify that the plans and specifications covered by
Review of the plans and
O�S14E S�,q?�
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
I
with the Florida Energy Code.
PREP D
DATE:
Before construction is completed
this building will be inspected for
a
`" 11j,
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
COb"1�E'
with Florida Energy Code.
the
ter. f
OWNER/AGFNT: £_
BUILDING OFFICIAL:
DATE: q " 13--i1
I
DATE:
an
ipliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
ified factory -sealed in accordance with R403.3.2.1'.
pliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
relope leakage test report with envelope leakage no greater than 7.00 ACH50 (111402.4.1.2).
8 11:22 AM
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 1 of 8
FORM
R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title)
TUBITO RESIDENCE
Bedrooms: 3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 3677
Lot #
Owner Name:
NICK TUBITO
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
OLEANDER AVENUE
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design
Temp
Int Design
Temp
Heating
Design Daily
Temp
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
I
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
AHU 1
1319
14369.2
2
AHU2
2358
26855.2
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
BONUS ROOM
317
4438 No
0
1
Yes
Yes
Yes
2
BATH 2
66
660 No
0
1
Yes
Yes
Yes
3
BEDROOM 2
188
1880 No
0
1
1
Yes
Yes
Yes
4
BATH 3
84
840 No
0
1
Yes
Yes
Yes
5
WIC 2
32
320 No
0
1
No
Yes
Yes
6
WIC 3
42
420 No
0
1
No
Yes
Yes
7
HALL
66
660 No
0
1
Yes
Yes
Yes
8
BUTLER PANTRY
54
540 No
0
1
No
Yes
Yes
9
HALLWAY
79
790 No
0
1
No
Yes
Yes
10
BEDROOM 3
169
1690 No
0
1
1
Yes
Yes
Yes
11
SAFE ROOM
222
2131.2 No
0
1
Yes
Yes
Yes
12
LAUNDRY
120
1200 No
0
1
Yes
Yes
Yes
13
PANTRY
90
900 No
0
1
No
Yes
Yes
14
KITCHEN
285
3249 Yes
0
1
No
Yes
Yes
15
GREAT ROOM
528
6547.2 No
0
1
Yes
Yes
Yes
16
FOYER
99
1287 No
0
1
Yes
Yes
Yes
17
STUDY
208
2496 No
0
1
Yes
Yes
Yes
18
MASTER BEDROO
320
3520 No
0
1
1
Yes
Yes
Yes
19
M HALL
28
280 No
0
1
No
Yes
Yes
20
M BATH
196
1960 No
0
1
Yes
Yes
Yes
21
M WIC 2
56
560 No
0
1
No
Yes
Yes
7/25) 01811:22 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 8
• FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
SPACES
Number Name
Area Volume
Kitchen Occupants
Bedrooms
InfilID Finished
Cooled
Heated
22
M WIC 1
160 1600
No 0
1 Yes
Yes
Yes
23
M TOILET
28 280
No 0
1 .Yes
Yes
Yes
24,
NOOK
240 2976
No 0
1 Yes
Yes
Yes
'
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
BONUS ROOM
53 ft
0
317 ft2
1
0
0
2 Slab -On -Grade Edge Insulation
BATH 2
6 ft
0
66 ft2
___
1
0
0
3 Slab -On -Grade Edge Insulation
BEDROOM 2
11.9 ft 0
188 ft2
-1
0
0
4 Slab -On -Grade Edge Insulation
BATH 3
8 ft
0
84 ft2
____
1
0
0
5 Slab -On -Grade Edge Insulation
WIC 2
1 ft
0
32 ft2
____
1
0
0
6 Slab -On -Grade Edge Insulation
WIC 3
1 ft
0
42 ft2
__
1
0
0
7 Slab -On -Grade Edge Insulation
HALL
6.3 ft
0
66 ft2
__
1
0
0
8 Slab -On -Grade Edge Insulation
BUTLER PANTR
1 ft
0
54 ft2
__
1
0
0
9 Slab -On -Grade Edge Insulation
HALLWAY
1 ft
0
79 1112
___
1
0
0
10SIab-On-Grade Edge Insulation
BEDROOM 3
13 ft
0
169 ft2
____
1
0
0
11SIab-On-Grade Edge Insulation
SAFE ROOM
23 ft
0
222 ft2
____
1
0
0
I
12SIab-On-Grade Edge Insulation
'
LAUNDRY
14 ft
0
120 ft2
___
1
0
0
13SIab-On-Grade Edge Insulation
PANTRY
1 ft
10
90 ft2
1
0
0
14SIab-On-Grade Edge Insulation
KITCHEN
1 ft
0
285 ft2
1
0
0
15SIab-On-Grade Edge Insulation
GREAT ROOM
22 ft
0
528 ft2
1
0
0
16SIab-On-Grade Edge Insulation
FOYER
9 ft
0
99 ft2
1
0
0
I
17SIab-On-Grade Edge Insulation
'
STUDY
26 ft
0
208 ft2
___
1
0
0
18SIab-On-Grade Edge Insulation
MASTER BEDRO
56 ft
0
320 ft2
___
1
0
0
19SIab-On-Grade Edge Insulation
M HALL
1 ft
0
28 ft2
___
1
0
0
20SIab-On-Grade Edge Insulation
M BATH
14 ft
0
196 ft2
1
0
0
21SIab-On-Grade Edge Insulation
M W IC 2
1 ft
0
56 ft2
___
1
0
0
22SIab-On-Grade Edge Insulation
M W IC 1
23 ft
0
160 ft2
___
1
0
0
23SIab-On-Grade Edge Insulation
M TOILET
lift
0
28 ft2
1
0
0
24SIab-On-Grade Edge Insulation
NOOK
22 ft
0
240 ft2
1
0
0
I
7/25/2018 11:22 AM
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 3 of
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
ROOF
Roof
Gable
Roof Solar SA
Emitt
Emitt
Deck
Pitch
#
Type
Materials Area
Area
Color Absor. Tested
Tested
Insul.
(deg)
1
Hip Composition shingles 4112 ft2
0 ft2 Medium 0.6
No
0.9
No
20
26.6
ATTIC
V
#
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Unvented
0
3677 ft2
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented)
BONUS ROOM
20
Blown
317ft2
0.1
Wood
2
Under Attic (Unvented)
BATH 2
20
Blown
66 ft2
0.1
Wood
3
Under Attic (Unvented)
BEDROOM 2
20
Blown
188 ft2
0.1
Wood
1
4
Under Attic (Unvented)
BATH 3
20
Blown
84 ft2
0.1
Wood
5
Under Attic (Unvented)
WIC 2
20
Blown
32 ft2
0.1
Wood
6
Under Attic (Unvented)
WIC 3
20
Blown
42 ft2
0.1
Wood
7
Under Attic (Unvented).
HALL
20
Blown
66 ft2
0.1
Wood
8
Under Attic (Unvented)
BUTLER PANTR
20
Blown*
54 ft2
0.1
Wood
9
Under Attic (Unvented)
HALLWAY
20
Blown
79 ft2
0.1
Wood
1
10
Under Attic (Unvented)
BEDROOM 3
20
Blown
169 ft2
0.1
Wood
I
11
Under Attic (Unvented)
SAFE ROOM
20
Blown
222 ft2
0.1
Wood
12
Under Attic (Unvented)
LAUNDRY
20
Blown
120 ft2
0.1
Wood
13
Under Attic (Unvented)
PANTRY
20
Blown
go ft2
0.1
Wood
14
Under Attic (Unvented)
KITCHEN
20
Blown
285 ft2
0.1
Wood
15
Under Attic (Unvented)
GREAT ROOM
20
Blown
528 ft2
0.1
Wood
16
Under Attic (Unvented),
FOYER
20
Blown
99ft2
0.1
Wood
17
Under Attic (Unvented)
STUDY
20
Blown
208 ft2
0.1
Wood
18
Under Attic (Unvented)
MASTER BEDRO
20
Blown
320 ft2
0.1
Wood
19
Under Attic (Unvented)
M HALL
20
Blown
28 ft2
0.1
Wood
20
Under Attic (Unvented)
M BATH
20
Blown
196 ft2
0.1
Wood
21
Under Attic (Unvented)
M WIC 2
20
Blown
56ft2
0.1
Wood
22
Under Attic (Unvented)
M W IC 1
20
Blown
160 ft2
0.1
Wood
23
Under Attic (Unvented)
M TOILET
20
Blown
28 ft2
0.1
Wood
24
Under Attic (Unvented)
NOOK
20
Blown
240 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
SpaceEt
Height
In
ArpnR-1/ah
Sheathing Framing
le
Solar
Below
_ 1
N
Exterior Concrete Block - Ext Ins80NUS ROO
4.1 20
0 14 0
280.0 ft2
0
0
0.6
0
2
S
Exterior Concrete Block - Ext InsiBONUS ROO
4.1 16
0 14 0
224.0 ft2
0
0
0.6
0
3
W
Exterior Concrete Block - Ext InsfflONUS ROO
4.1 17
0 14 0
238.0 ft2
0
0
0A
0
4
N
Exterior Concrete Block - Ext Insul BATH 2
4.1 6
d 10 0
60.0 ft2
0
0
0.6
0
5
N
Exterior Concrete' Block - Ext InstBEDROOM 2
4.1 12
0 10 0
120.0 ft2
0
0
0.6
0
7/25/201811:22 AM EnergyGauge® USA Section R405.4.1 Compliant Software . Page 4 of 8
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing.
Solar
Below
Space
-
-
_ 6
N
Exterior
Concrete Block - Ext Insul BATH 3
4.1
6
0
10
0
60.0 ft2
0
0
0.6
0
7
E
Exterior
Concrete Block - Ext Insul BATH 3
4.1
1
0
10
0
10.6 ft.
0
0
0.6
0
8
W
Exterior
Concrete Block - Ext Insul BATH 3
. 4.1
1
0
10
0
10.0 ftz
0
0
0.6
0
911
SW
Exterior
Concrete Block - Ext Insul HALL
4.1
6
5
10
0
64.2 ft2
0
0
0.6
0
10;
N
Exterior
Concrete Block - Ext Inse1EDROOM 3
4.1
13
0
10
0
130.0 ft2
0
'0
0.6
0
_ 11l
N
Exterior
Concrete Block - Ext Inst4AFE ROOM
4.1
15
0
9
6
142.5 ft2
0
0
0.6
0
121
E
Exterior
Concrete Block - Ext InsiSAFE ROOM
4.1
4
0
9
6
38.0 ft2
0
0
0.6
0
13
W
Exterior
Concrete Block - Ext InstSAFE ROOM
4.1
3
10
10
0
38.3 f12
0
0
0.6
0
14
E
Exterior.
Concrete Block - Ext InsuILAUNDRY
4.1
11
0
10
0
110.0 ft2
0
0
0.6
0
15
S
Exterior
Concrete Block - Ext InsuILAUNDRY
4.1
3
0
10
0
30.0 1`12
0
0
0.6
0
161
W
Exterior
Concrete Block - Ext InsGREAT ROO
4.1
22
0
12
4
271.3 ft2
0-
0
0.6
0
17
E
Exterior
Concrete Block - Ext Insul FOYER
4.1
9
0 -13
0
117.0 ft2
0
0
0.6
0
18
N
Exterior
Concrete Block - Ext Insul STUDY
4.1
5
0
12
0
60.0 ft2
0
0
0.6
0
19
E
Exterior
Concrete Block- Ext Insul STUDY
4.1
13
0
12
0
166.0 ft2
0
0
0.6
0
20
S
Exterior
Concrete Block - Ext Insul STUDY
4.1
8
0
12
0
96.0 ft2
0
0
0.6
0
211
N
Exterior
Concrete Block - Ext InsdMASTER BE
4.1
20
0
11
0
220.0 ft2
0
0
0.6
0
_ 221
S
Exterior
Concrete Block - Ext InstWIASTER BE
4.1
20
0
11
0
220.0 ft2
0
0
0.6
0
23
W
Exterior
Concrete Block - Ext InsMASTER BE
4.1
16
0
11
0
176.0 ft2
0
0
0.6
0
24
S
Exterior
Concrete Block - Ext Insul M BATH
4.1
14
0
10
0
140.0. ft2
0
0
0.6
0
25
E
Exterior
Concrete Block - Ext Insul M WIC 1
4.1
12
0
10
0
120.0 ft2
0
0
0.6
0
26
S
Exterior
Concrete Block - Ext Insul M WIC 1
4.1
11
0
10
0
110.0 ft2
0
0
0.6
0
_ 27
E
Exterior
Concrete Block - Ext InsulM TOILET
4.1
4
0
10
0
40.0 ft2
0
0
0.6
U
_ 28
S
Exterior
Concrete Block - Ext InsulM'TOILET
4.1
7
0
10
0
70.0 ft2
0
0
0.6
0
29
S
Exterior
Concrete Block -`Ext Insul NOOK
4.1
9
0
12
4
111.0 ft2
0
0
0.6
0
30
W
Exterior
Concrete Block - Ext Insul NOOK.
4.1
13
0
12
4
160.3 fF
0
0.
066
0
31
E
Garage
Frame - Wood SAFE ROOM
11
27
10
270.01ft2
0
0.25 0.60000*0
0
32 I
S
Garage
Frame - Wood SAFE ROOM
11
4
10
40.0 ft2
0
0.25 0.600000
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
�/ #
Omt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
ilI
N 1
Metal Low-E Single Yes
0.65
0.25
N
18.0 ft2
1 ft 6 in
1 ft 4 in
None
None
'2
W 3
Metal Low-E Single Yes
0.65
0.25
N
24.0 ft2
1 ft 6 in
1 ft 4 in
None
None
3
W 3
Metal N Low-E Single Yes
0.65
0.25
N
30.0 1t2
1 ft 6 in
1 ft 4 in
None
None
4
N 4
Metal Low-E Single Yes
0.65
0.25
N
8.0 f12
1 ft 6 in
1 ft 4 in
None
None
15
N 5
Metal Low-E Single Yes
0.65
0.25
N
18.0 ft2
1 ft 6 in
1 ft 4 in
None
None
I6
N 6
Metal Low-E Single Yes
0.65
0.25
N
8.0 ft2
1 ft 6 in
1 ft 4 iri
None
None
I 7
SW 9
Metal Low-E Single Yes
0.7
0.3
N
21.3 ft2
'1 ft 6 in
1 ft 4 in
None
None
9
N 10
Metal Low-E Single Yes
0.65
0.25
N
18.0 ft2
1 ft 6 in
1 ft 4 in
None
None
9
E 14
Metal Low-E Single Yes
0.65
0.25
N
12.0 ft2
1 ft 6 in
1 ft 4 in
None
None
10
W 16
Metal Low-E Single Yes
•0.7
0.3
N
120.0 ft2
14 ft 0 in
1 ft 4 in
None
None
11
E 17
Metal Low-E Single Yes
0.65
0.25
N
18.0 ft2
1 ft 6 in
1 ft 4 in
None
None
12
E 17
Metal Low-E Single Yes .
0.7
0.3
N
48.0 ft2
1 ft 6 in
1 ft 4 in
None
None
7/25/201a I1:22 AM EnergyGauge@ USA Section R405A.1 Compliant Software Page 5 of 8.
i
FORM R405-2017 INPUT SUMMARY CHECKLIST RFPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
�/ #
Omt ID Frame
Panes
NFRC
U-Factor SHGC Imp
Area Depth
Separation
Int Shade
Screening
13
E 19 Metal
Low-E Single
Yes
0.65 0.25 N
12.0 ft2 1 ft 6 in
1 ft 4 in
None
None
14
E 19 Metal
Low-E Single
Yes
0.65 0.25 N
12.0 ft2 0 ft 0 in
0 ft 0 in
None
None
15
i
E 19 Metal
Low-E Single
Yes
0.65 0.25 N
24.0 ft2 1 ft 6 in
1 ft 4 in
None
None
16
N 21 Metal
Low-E Single
Yes
0.7 0.3 N
21.3 ft2 1 ft 6 in
1 ft 4 in '
None
None
17
W 23 Metal
Low-E Single
Yes
0.65 0.25 N
24.0 ft2 1 ft 6 in
1 ft 4 in
None
None
18
W 23 Metal
Low-E Single
Yes
0.65 0.25 N
30.0 ft2 1 ft 6 in
1 ft 4 in
None
None
19
S 24 Metal
Low-E Single
Yes
0.65 0.25 N
10.Qft2 . 1 ft 6 in
1 ft 4 in
None
None
20
E 25 Metal
Low-E Single
Yes
0.65 0.25 N
. 6.0 ft2 1.ft 6 in
1 ft 4 in
None
None
21
S 28 Metal
Low-E Single
Yes
0.65 0.25 N
8.0 ft2 1 ft 6 in
1 ft 4 in
None
None
22
S 29 Metal
Low-E Single
Yes
0.7 0.3 N
90.0 ft2 12 ft 0 in
1 ft 4 in
None
None
23
W 30 Metal
Low-E Single
Yes
0.7 0.3 N
90.0 ft2 12 ft 0 in
1 ft 4 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
864 ft2
864 ft2
31 ft
loft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse ProposedACH(50) .000499
4809.5 264.04 496.56 .3998
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COPA
17 kBtu/hr
1
sys#1
2
Electric Strip Heat/
None
COPA
27 kBtu/hr
2
sys#2
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow SHR
Block
Ducts
j 1
Central Unit/
Split
SEER: 16
24 kBtu/hr 720 cfm 0.8
1
Sys#1
2
Central Unit/
Split
SEER: 16
42 kBtu/hr 1260 cfm 0.8
2
sys#2
I
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap
Use SetPnt
Conservation
1
Electric
None
Garage
0.98 40 gal 60.9 gal 120 deg
None
7/25/201811:22 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 8
i
1
• FORM R40R-9017 INPIIT _kIMAMAPV ('_141=f%KI ICT DGDnDT
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model
# Area
Volume
FEF
None
None
ft2
DUCTS
/
— Supply—
— Return —
Air
CFM 25
CFM25
HVAC #
V #
Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 1
Attic
6
140 ft2
Attic
14 ft2
Default Leakage
Attic
(Default) c(Default) c
1 1
2
Attic
6
175 ft2
Attic
18 ft2
Default -Leakage
Attic
(Default) c(Default) c
2 2
i
TEMPERATURES
Progriamable Thermostat: N
Ceiling Fans:
CoolingJan
HeatinJan
Feb
Feb
Mar
Mar
f
Apr
Apr f
May
May
Jun Jul
Jun Jul
Auge
AuSep
E
Oct
Oct
Nov
Nov
Dec
Dec
Ventin Jan
Feb
Mar
[Xj
Apr [
May
Jun Jul
Aug
Se
(X]
Oct
Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
SchedulIa Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling'(WD)
AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
80
80
78 78
78
78
78
78
78
78
Cooling (W EH)
AM
78
78
78
78
78 78
78
78
80
80
80
80
1
PM
80
80
80
80
78 78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65
65
65 65
65
68
68
-68
68
68
i
PM
68
68
68
68
68 68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65 65
65
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
68
68
I
7/25/2018 11:22 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 7 of 8
I
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT f
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft2
0 ft
0.3
BONUS ROOM
j Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 3
Default(81bs/sq.ft.
ft2
ft
0.3
HALL
�Default(8lbs/sq.ft.
ft2
ft
0.3
BUTLER,PANTRY
IDefault(8 lbs/sq.ft.
ft2
ft
0.3
HALLWAY
IDefault(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
IDefault(8 Ibs/sq.ft.
ft2
ft
0.3
SAFE ROOM
�Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
PANTRY
Default(81bs/sq.fL
ft2
ft
0.3
KITCHEN
befault(8lbs/sq.ft.
ft2
ft
0.3
GREAT ROOM
Default(81bs/sq.fL
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
STUDY
i
Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
IDIefault(8
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
i
Default(8lbs/sq.ft.
ft2
ft
0.3
M WIC 2
Default(81bs/sq.ft.
ft2
It
0.3
M WIC 1
Default(8 Ibs/sq.ft.
ft2
It
0.3
M TOILET
Default(8 Ibs/sq.fL
ft2
ft
0.3
NOOK
Name:
Rating Compant:
r
-AZ %VV),`; ll f
..
7/25/201 1 11:22 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 8 of 8
I
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
I
Project Name: TUBITO RESIDENCE Builder Name:
Street: OLEANDER AVENUE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Owner: NICK TUBITO Jurisdiction: ST LUCIE COUNTY
W
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
.
regwrements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceil I
g/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction. of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(inclyding
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing,' or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members. .
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or, unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narroty cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage
separation
Air sealing shall'be provided between the garage and conditioned spaces.
Recesed
lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall, be air tight and IC rated.
Plumbing
and wiring
Batt insulation shall be cut neatly to fit around wiring an
J
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind 061no and wirin .
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior
wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone
box on
The air barrier shall be installed behind electrical or communication
exterior
walls
boxes or air -sealed boxes shall be installed.
HVAC
register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or, drywall.
Concealed
When required.to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler ;
cover plates and walls or ceilings.
U. If aaawon, II15pe0[IM OT log walls snarl be in accoroance Wim me provisions or iGG-4uu.
7/25/201811:22 AM EnergyGaugeO USA FBC 6th Edition (2017):Compliant Software Page 1 of 1