RE: Oakland Lake (Lot 68) 1452 Model, Permit #1809-0671
[PLANS EXAMINER REVIEW]
RECEIVED
16 2018 .
ST. Lucie County, Permitting
SCANNED
By
St Lucie County
PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING
THE SQUARE FOOT INFORMATION OR A LETTER FROM THE DESIGN PROFESSIONAL SPECIFYING THE
CUBIC VOLUME. OF THE CONDITIONED SPACE. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA
BUILDING CODE.
See revised sheet CS of 6
2017 FLORIDA BUILDING CODE 6TH EDITION R311.5.1 ATTACHMENT. SHOW THE METHED EXTERIOR
LANDINGS SHALL BE POSITIVELY ANCHORED TO THE PRIMARY STRUCTURE TO RESIST BOTH VERTICAL
AND LATERAL FORCES OR SHALL BE DESIGNED TO BE SELF-SUPPORTING.
See Reinforcing Steel note 5 on sheet GN of 6: Run reinforcing bars continuously lapped at splices and
around corners. Dowel into intersecting walls and hook at ends. Stagger splices at least 25" wherever
possible.
Should you have any questions regarding this letter, do not hesitate to call me.