Loading...
HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCEPlanning & Development Services Department Building & Code Regulations Divi ion a �42�95� 2300 Virginia Avenue, Fort Pierce, FL 34982 (77 Certification for Design Load Compl Project Name: TARPON FLATS LOT 32 - MODEL B Ice SEP 24 ,,n ST. Lucie County, Permitting Project Address: 3906 Duneside Drive Ft. Pierce, FL. SCANNED Permit #: Occupancy Type: R-3 Construction Type: V-B BY INSTRUCTIONS FOR USE: St Lucie County • This certification must be completed, signed, and sealed by the design professional of record. i • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida X Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: B C X D 4. Design Wind Velocity 170 mph ASD LRFD End Zone Width: ft 5. Mean Roof Height 24.6' ft Roof Pitch: 6 :12 Parapet: 0 ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: -44.85 Zone 2: -75.13 Zone 3: -112.36 Zone 4: -49•95 Zone 5: -58.38 Garage: -50.37 7. Design Loads: Floor: 80 PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: 14 PSF Dock: NA PSF Deck: 177 PSF Stairs: 40 PSF Fence: NA PSF Railings: NA PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2,500 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie 'County. �I,e1�d �celr�i��r�tM� structural elements depicted on these plans provide adequate resistance to the design forc,* P-_ Pi�UC'.ATT,9�'�i �\GENSE' , S �� Farid Abugattas 72471 * ' 1 % Print Name Cert # & Co. Cert Auth. No 72 =_ Porject Classic LUZ fSinre, a&ieal _ 7318 Texas Trail, Boc ato I , � i T •. FLORIOP.•.•��``. ..........Company N dr Jt Revised