HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCEPlanning & Development Services Department
Building & Code Regulations Divi ion
a �42�95�
2300 Virginia Avenue, Fort Pierce, FL 34982 (77
Certification for Design Load Compl
Project Name: TARPON FLATS LOT 32 - MODEL B
Ice
SEP 24 ,,n
ST. Lucie County, Permitting
Project Address: 3906 Duneside Drive Ft. Pierce, FL. SCANNED
Permit #: Occupancy Type: R-3 Construction Type: V-B BY
INSTRUCTIONS FOR USE: St Lucie County
• This certification must be completed, signed, and sealed by the design professional of record.
i
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida X Code Fifth Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: _I X II III IV Exposure Category: B C X D
4. Design Wind Velocity 170 mph ASD LRFD End Zone Width: ft
5. Mean Roof Height 24.6' ft Roof Pitch: 6 :12 Parapet: 0 ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: -44.85 Zone 2: -75.13 Zone 3: -112.36 Zone 4: -49•95 Zone 5: -58.38 Garage: -50.37
7. Design Loads: Floor: 80 PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: 14 PSF
Dock: NA PSF Deck: 177 PSF Stairs: 40 PSF Fence: NA PSF Railings: NA PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2,500 PSF Soil Test Reports Submitted? X Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
'County. �I,e1�d �celr�i��r�tM� structural elements depicted on these plans provide adequate resistance to the design
forc,* P-_ Pi�UC'.ATT,9�'�i
�\GENSE' , S �� Farid Abugattas 72471
* ' 1
% Print Name Cert # & Co. Cert Auth.
No 72
=_ Porject Classic
LUZ
fSinre, a&ieal _ 7318 Texas Trail, Boc ato I ,
� i T •. FLORIOP.•.•��``.
..........Company N dr
Jt
Revised