Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODERECEIVED SEP 24 2018 FORM R405-2017 FLORIDA ENERGY EFFICIE L� r -' -� t UILDING CONSTRUCTION Florida Department of Business and Professional Regulation -.Residential Performance Method Project Name: Lot32TarponFlatsModelB Builder Name: Phoenix Realty Homes SCANNED Street: 3906 Dune Side Drive Permit Office: IV�y�® City, State, Zip: Fort Pierce, FL , Permit Number: _BY Owner: Jurisdiction: 661100 126 Lucie Cunt Design Location: FL, Fort Pierce I County:: St. Lucie (Florida Climate Zone 2 1. New construction or existing New (From Plans) 9. Wall Types (3201.3 sqft) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 2972.70 ft' b. Frame -Wood, Exterior R=13.0 149.33 ft' 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=13.0 79.33 ft' 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (1974.0 sqft.) Insulation Area I a. Roof Deck (Unvented) R=20.0 1261.00 ft' 6. Conditioned floor area above grade (ftJ 2687 b. Roof Deck (Unvented) R=20.0 713.00 ft' Conditioned floor area below grade 0 I c. N/A 11. Ducts R= ft' R ft' 7. Windows(523.9 sgfL) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 394.8 a. U!Factor: Dbl, U=0.66 307.92 ft' b. Sup: Attic, Rat: Attic, AH: Attic 6 142.6 SHGC: SHGC=0.35 IFactor: Dbl, U=1.01 216.00 ft' b. U- 12. Cooling systems kBtu/hr Efficiency I SHGC: SHGC=0.50 a. Central Unit 47.0 SEER:16.00 b. Central Unit 18.8 SEER:16.00 C. UFactor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U,Factor: N/A ft' a. Electric Heat Pump 47.0 HSPF:9.00 SHGC: b. Electric Heat Pump 18.8 HSPF:9.00 Area Weighted Average Overhang Depth: 4.305 ft. Area Weighted Average SHGC: 0.412 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor,, ,Types (2687.0 sqft) Insulation Area EF: 2.400 a. Slab -On -Grade Edge Insulation R=0.0 1974.00 ft' b. Conservation features b. Floor Over Other Space R=0.0 713.00 ft' None c. N/A R= ft' I 15. Credits Pstat Glass/Floor Area: 0.195 Total Proposed Modified Loads: 83.67 PASS Total Baseline Loads: 91.83 /'1�7�7 i I hereby certify that the plans and specifications covered by Review of the plans and O this calculation are in compliance with the Florida Energy specifications covered by this +( Code. �, Russell Henry calculation indicates compliance with the Florida Energy Code. y%i t`� (IIIJ %�, F ;� 8• x PREPARED BY: Before construction is completed DATE: I'' September 21.2018 this building will be inspected for compliance with Section 553.908 Florida Statutes. s a „• ,� ' S I hereb I' certify that this building, as designed, is in compliance with the Florida Energ Code. IR/ OWNE T: BUILDING OFFICIAL: DATE: ` DATE: I - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection .Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4 I . 4 9/21/2018 9:49 AM EnergyGaugeOETaLE-ectiLa4oLjc&plianISoftware Page 1 of 5 FORM ,R405-2017 PROJECT Title Lot32TarponFlatsModelB Bedrooms: 3 Address Type: Lot Information Building Type: User Conditioned Area: 2687 Lot # 32 Owner Name: Total Stories: 2 Block/Subdivision: Tarpon Flats # of Units: 1 Worst Case: No PlatBook: Builder Name: Phoenix Realty Homes Rotate Angle: 0 Street: 3906 Dune Side Drive Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661100 Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, New%Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Block1 1974 18417.4 2 Block2 713 6652.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st Floor 1974 18417.4 Yes 4 2 1 Yes Yes Yes 2 2nd Floor 713 6652.3 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio I 1st Floor 196.5 ft 0 1974 ft2 --- 0.32 0 0.68 2 Floor Over Other Space 2nd Floor --_ -_- 713 ft2 0 0.32 0 0.68 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) I 1 Hip Metal 2208 ft2 0 ft2 Medium 0.65 N 0.9 No 20 26.6 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1974 ft2 N N 9/21/2018 9:49 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 1 FORM I R405-2017 i CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) 1st Floor 0 Blown 1261ft2 0.11 Wood I 2 Under Attic (Unvented) 2nd Floor 30 Blown 713 ft2 0.11 Wood WALLS Omt Adjacent 10 Mil T SpaceR-VahleR_Van Cavity Width Height Et n Area Sheathing Framing Solar Beloa w on 1 NE Exterior Concrete Block - Int Insul 1st Floor 4.1 16 0 9 4 149.3 ft2 0 0 0.6 0 2 NE Exterior Concrete Block - Int Insul 1st Floor 4.1 27 0 9 4 252.0 ft2 0 0 0.6 0 3 NE Exterior Concrete Block - Int Insul2nd Floor 4.1 27 0 9 4 252.0 ft2 0 0 0.6 0 4 NE Exterior Concrete Block - Int Insul 1st Floor 4.1 16 0 9 4 149.3 ft2 0 0 0.6 0 I 5 SE Exterior Concrete Block - Int Insul 1st Floor 4.1 35 6 9 4 331.3 ft2 0 0 0.6 0 I 6 SE Exterior Concrete Block - Int Insul 1st Floor 4.1 4 0 9 4 37.3 ft2 0 0 0.6 0 I - 7 SE Exterior Concrete Block- Int Insul2nd Floor 4.1 34 0 9 4 317.3 ft2 0 0 0.6 0 I 8 SE Exterior Concrete Block - Int Insul 1st Floor 4.1 8 6 9 4 79.3 ft2 0 0 0.6 0 I 9 SW Exterior. Concrete Block - Int Insul 1st Floor 4.1 24 0 9 4 224.0 ft2 0 0 0.6 0 I 10 SW Exterior Concrete Block - Int Insul 1st Floor 4.1 14 0 9 4 130.7 ft2 0 0 0.6 0 _ _ 11 SW Exterior Concrete Block - Int Insul2nd Floor 4.1 27 0 9 4 252.0 ft2 0 0 0.6 0 12 NW Exterior Concrete Block - Int Insul 1st Floor 4.1 51 6 9 4 480.7 ft2 0 0 0.6 0 _ 13 NW Exterior Concrete Block - Int Insul2nd Floor 4.1 34 0 9 4 317.3 ft2 0 0 0.6 0 _ 1 - i Garage Frame - Wood 1st Floor 13 8 6 9 4 79.3 ft2 0 0.23 0.01 0 _ 15 - I Exterior Frame - Wood 1st Floor 13 16 0 9 4 149.3 ft2 0 0.23 0.6 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SW Insulated 1st Floor None .25 3 8 24 ft2 2 - Wood 1st Floor None .25 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NE 1 Metal Low-E Double Yes 0.66 0.35 N 16.7 ft2 2 ft 4 in 0 ft 5 in Drapes/blinds Exterior 5 2 NE 1 Metal Low-E Double Yes 0.66 0.35 N 31.3 ft2 2 ft 4 in 0 ft 5 in Drapes/blinds Exterior 5 3 NE 2 Metal Low-E Double Yes 1.01 0.5 N 144.0 ft2 2 ft 4 in 12 ft 0 in None Exterior 5 4 NE 3 Metal Low-E Double Yes 0.66 0.35 N 56.0 ft2 2 ft 4 in 0 ft 5 in Drapes/blinds Exterior 5 5 NE 4 Metal Low-E Double Yes 1.01 0.5 N 72.0 ft2 13 ft 4 in 0 ft 5 in None Exterior 5 6 SE 5 Metal Low-E Double Yes 0.66 0.35 N 3.0 ft2 2 ft 4 in 0 ft 5 in None None 7 SE 7 Metal Low-E Double Yes 0.66 0.35 N 4.0 ft2 2 ft 4 in 0 ft 5 in None None 8 SE 8 Metal Low-E Double Yes 0.66 0.35 N 11.1 ft2 2 ft 4 in 0 ft 5 in Drapes/blinds Exterior 5 9 SW 9 Metal Low-E Double Yes 0.66 0.35 N 32.9 ft2 2 ft 4 in 0 ft 5 in Drapes/blinds Exterior 5 10 SW 9 Metal Low-E Double Yes 0.66 0.35 N 32.3 ft2 2 ft 0 in 11 ft 9 in Drapes/blinds Exterior 5 11 SW 10 Metal Low-E Double Yes 0.66 0.35 N 12.0 ft2 7 ft 0 in 0 ft 2 in None None 12 SW 11 Metal Low-E Double Yes 0.66 0.35 N 14.0 ft2 2 ft 4 in 0 ft 5 in Drapes/blinds Exterior 5 13 SW 11 Metal Low-E Double Yes 0.66 0.35 N 32.4 ft2 2 ft 4 in 0 ft 5 in Drapes/blinds Exterior 5 +i I 9/21/2018 9:49 AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 14 15 i 16 17 SW 11 Metal Low-E Double Yes NW 12 Metal Low-E Double Yes NW 12 Metal Low-E Double Yes NW 13 Metal Low-E Double Yes 0.66 0.35 N 28.0 ft2 7 ft 4 in 0 ft 3 in Drapes/blinds 0.66 0.35 N 14.0 ft2 2 ft 4 in 0 ft 5 in Drapes/blinds 0.66 0.35 N 6.3 ft2 2 ft 4 in 0 ft 5 in Drapes/blinds 0.66 0.35 N 14.0 ft2 6 ft 4 in 0 ft 5 in Drapes/blinds Exterior 5 Exterior 5 Exterior 5 Exterior 5 GARAGE- # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 492 ft2 492 ft2 66.75 ft 9.33 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000415 2924.8 160.57 301.97 .373 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Heat Pump/ Electric Heat Pump/ Split Split HSPF:8.9999 47 kBtu/hr 1 HSPF:8.9999 18.8 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split SEER: 16 47 kBtu/hr 1410 cfm 0.75 1 SEER: 16 18.8 kBtu/hr 564 cfm 0.75 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 1 Electric Heat Pump Garage 2.4 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF i None None ft2 DUCTS # -- Supply --- Location R-Value Area -- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 394.8 ft Attic 6 142.6 ft Attic Attic 98.7 ft2 Default Leakage Attic (Default) (Default) 35.65 ft Default Leakage Attic (Default) (Default) 1 1 2 2 9/21/2018 9:49 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-?_017 TEMPERATURES Progr1amable Thermostat: Y Ceiling Fans: Heat Heating Jan Feb Mar Apr I May ri I Jun X Jul JXJ Aug Sep XJ Sep 0 Oct Nov Nov Dec HDecVenting Jan Feb l�J Mar Apr May Jun Jul lAug lX Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78- 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68. 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type I Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System Runtime Vent 58 0 0 0 1 - Electric Heat Pump % 1 - Central Unit 9/21/2018 9:49 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5