HomeMy WebLinkAboutENERGY EFFICIENCY CODERECEIVED
SEP 24 2018
FORM R405-2017
FLORIDA ENERGY EFFICIE L� r -' -� t UILDING CONSTRUCTION
Florida Department of Business and Professional Regulation -.Residential Performance Method
Project Name: Lot32TarponFlatsModelB
Builder Name: Phoenix Realty Homes
SCANNED
Street: 3906 Dune Side Drive
Permit Office:
IV�y�®
City, State, Zip: Fort Pierce, FL ,
Permit Number:
_BY
Owner:
Jurisdiction: 661100
126 Lucie Cunt
Design Location: FL, Fort Pierce
I
County:: St. Lucie (Florida Climate
Zone 2
1. New construction or existing New (From Plans)
9. Wall Types (3201.3 sqft)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 2972.70 ft'
b. Frame -Wood, Exterior
R=13.0 149.33 ft'
3. Number of units, if multiple family 1
c. Frame - Wood, Adjacent
R=13.0 79.33 ft'
4. Number of Bedrooms 3
d. N/A
R= ft'
5. Is this a worst case? No
10. Ceiling Types (1974.0 sqft.)
Insulation Area
I
a. Roof Deck (Unvented)
R=20.0 1261.00 ft'
6. Conditioned floor area above grade (ftJ 2687
b. Roof Deck (Unvented)
R=20.0 713.00 ft'
Conditioned floor area below grade 0
I
c. N/A
11. Ducts
R= ft'
R ft'
7. Windows(523.9 sgfL) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 394.8
a. U!Factor: Dbl, U=0.66 307.92 ft'
b. Sup: Attic, Rat: Attic, AH: Attic
6 142.6
SHGC: SHGC=0.35
IFactor: Dbl, U=1.01 216.00 ft'
b. U-
12. Cooling systems
kBtu/hr Efficiency
I
SHGC: SHGC=0.50
a. Central Unit
47.0 SEER:16.00
b. Central Unit
18.8 SEER:16.00
C. UFactor: N/A ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U,Factor: N/A ft'
a. Electric Heat Pump
47.0 HSPF:9.00
SHGC:
b. Electric Heat Pump
18.8 HSPF:9.00
Area Weighted Average Overhang Depth: 4.305 ft.
Area Weighted Average SHGC: 0.412
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor,,
,Types (2687.0 sqft) Insulation Area
EF: 2.400
a. Slab -On -Grade Edge Insulation R=0.0 1974.00 ft'
b. Conservation features
b. Floor Over Other Space R=0.0 713.00 ft'
None
c. N/A R= ft'
I
15. Credits
Pstat
Glass/Floor Area: 0.195 Total Proposed Modified Loads: 83.67
PASS
Total Baseline Loads: 91.83
/'1�7�7
i
I hereby certify that the plans and specifications covered by
Review of the plans and
O
this calculation are in compliance with the Florida Energy
specifications covered by this
+(
Code. �,
Russell Henry
calculation indicates compliance
with the Florida Energy Code.
y%i t`�
(IIIJ %�, F ;� 8• x
PREPARED BY:
Before construction is completed
DATE: I'' September 21.2018
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
s
a „• ,� ' S
I hereb I' certify that this building, as designed, is in compliance
with the Florida Energ Code.
IR/
OWNE T:
BUILDING OFFICIAL:
DATE: `
DATE:
I
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection .Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
4
I .
4
9/21/2018 9:49 AM
EnergyGaugeOETaLE-ectiLa4oLjc&plianISoftware
Page 1 of 5
FORM ,R405-2017
PROJECT
Title
Lot32TarponFlatsModelB Bedrooms: 3
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 2687
Lot #
32
Owner Name:
Total Stories: 2
Block/Subdivision:
Tarpon Flats
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Phoenix Realty Homes
Rotate Angle: 0
Street:
3906 Dune Side
Drive
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661100
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type:
Single-family
FL,
New%Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number
Name
Area Volume
1
Block1
1974 18417.4
2
Block2
713 6652.3
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
1st Floor
1974 18417.4 Yes 4
2
1 Yes
Yes
Yes
2
2nd Floor
713 6652.3 No 0
1
1 Yes
Yes
Yes
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
I
1st Floor 196.5 ft 0
1974 ft2
---
0.32 0
0.68
2 Floor Over Other Space
2nd Floor --_ -_-
713 ft2
0
0.32 0
0.68
ROOF
Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
V #
Type
Materials Area Area Color
Absor.
Tested
Tested Insul.
(deg)
I
1
Hip
Metal 2208 ft2 0 ft2 Medium
0.65
N 0.9
No 20
26.6
ATTIC
#
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvented 0 1974 ft2
N N
9/21/2018 9:49 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
1
FORM I R405-2017
i
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented) 1st Floor
0
Blown
1261ft2
0.11
Wood
I
2
Under Attic (Unvented) 2nd Floor
30
Blown
713 ft2
0.11
Wood
WALLS
Omt
Adjacent
10 Mil T SpaceR-VahleR_Van
Cavity
Width
Height
Et n
Area
Sheathing Framing Solar Beloa w
on
1
NE
Exterior
Concrete Block - Int Insul 1st Floor
4.1
16
0
9 4
149.3 ft2
0
0 0.6
0
2 NE
Exterior
Concrete Block - Int Insul 1st Floor
4.1
27
0
9 4
252.0 ft2
0
0 0.6
0
3 NE
Exterior
Concrete Block - Int Insul2nd Floor
4.1
27
0
9 4
252.0 ft2
0
0 0.6
0
4 NE
Exterior
Concrete Block - Int Insul 1st Floor
4.1
16
0
9 4
149.3 ft2
0
0 0.6
0
I
5 SE
Exterior
Concrete Block - Int Insul 1st Floor
4.1
35
6
9 4
331.3 ft2
0
0 0.6
0
I
6 SE
Exterior
Concrete Block - Int Insul 1st Floor
4.1
4
0
9 4
37.3 ft2
0
0 0.6
0
I
- 7 SE
Exterior
Concrete Block- Int Insul2nd Floor
4.1
34
0
9 4
317.3 ft2
0
0 0.6
0
I
8 SE
Exterior
Concrete Block - Int Insul 1st Floor
4.1
8
6
9 4
79.3 ft2
0
0 0.6
0
I
9 SW
Exterior.
Concrete Block - Int Insul 1st Floor
4.1
24
0
9 4
224.0 ft2
0
0 0.6
0
I
10 SW
Exterior
Concrete Block - Int Insul 1st Floor
4.1
14
0
9 4
130.7 ft2
0
0 0.6
0
_
_ 11 SW
Exterior
Concrete Block - Int Insul2nd Floor
4.1
27
0
9 4
252.0 ft2
0
0 0.6
0
12 NW
Exterior
Concrete Block - Int Insul 1st Floor
4.1
51
6
9 4
480.7 ft2
0
0 0.6
0
_ 13 NW
Exterior
Concrete Block - Int Insul2nd Floor
4.1
34
0
9 4
317.3 ft2
0
0 0.6
0
_ 1
-
i
Garage
Frame - Wood 1st Floor
13
8
6
9 4
79.3 ft2
0
0.23 0.01
0
_ 15 -
I
Exterior
Frame - Wood 1st Floor
13
16
0
9 4
149.3 ft2
0
0.23 0.6
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
SW
Insulated 1st Floor
None
.25
3
8
24 ft2
2
-
Wood 1st Floor
None
.25
2
8
8
21.3 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Omt ID
Frame Panes NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
NE 1
Metal Low-E Double Yes
0.66
0.35
N
16.7 ft2
2 ft 4 in
0 ft 5 in
Drapes/blinds
Exterior 5
2
NE 1
Metal Low-E Double Yes
0.66
0.35
N
31.3 ft2
2 ft 4 in
0 ft 5 in
Drapes/blinds
Exterior 5
3
NE 2
Metal Low-E Double Yes
1.01
0.5
N
144.0 ft2
2 ft 4 in
12 ft 0 in
None
Exterior 5
4
NE 3
Metal Low-E Double Yes
0.66
0.35
N
56.0 ft2
2 ft 4 in
0 ft 5 in
Drapes/blinds
Exterior 5
5
NE 4
Metal Low-E Double Yes
1.01
0.5
N
72.0 ft2
13 ft 4 in
0 ft 5 in
None
Exterior 5
6
SE 5
Metal Low-E Double Yes
0.66
0.35
N
3.0 ft2
2 ft 4 in
0 ft 5 in
None
None
7
SE 7
Metal Low-E Double Yes
0.66
0.35
N
4.0 ft2
2 ft 4 in
0 ft 5 in
None
None
8
SE 8
Metal Low-E Double Yes
0.66
0.35
N
11.1 ft2
2 ft 4 in
0 ft 5 in
Drapes/blinds
Exterior 5
9
SW 9
Metal Low-E Double Yes
0.66
0.35
N
32.9 ft2
2 ft 4 in
0 ft 5 in
Drapes/blinds
Exterior 5
10
SW 9
Metal Low-E Double Yes
0.66
0.35
N
32.3 ft2
2 ft 0 in
11 ft 9 in
Drapes/blinds
Exterior 5
11
SW 10
Metal Low-E Double Yes
0.66
0.35
N
12.0 ft2
7 ft 0 in
0 ft 2 in
None
None
12
SW 11
Metal Low-E Double Yes
0.66
0.35
N
14.0 ft2
2 ft 4 in
0 ft 5 in
Drapes/blinds
Exterior 5
13
SW 11
Metal Low-E Double Yes
0.66
0.35
N
32.4 ft2
2 ft 4 in
0 ft 5 in
Drapes/blinds
Exterior 5
+i
I
9/21/2018 9:49 AM
EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 3 of 5
FORM R405-2017
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
V #
Wall
Ornt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
14
15
i
16
17
SW 11 Metal Low-E Double Yes
NW 12 Metal Low-E Double Yes
NW 12 Metal Low-E Double Yes
NW 13 Metal Low-E Double Yes
0.66 0.35 N 28.0 ft2 7 ft 4 in 0 ft 3 in Drapes/blinds
0.66 0.35 N 14.0 ft2 2 ft 4 in 0 ft 5 in Drapes/blinds
0.66 0.35 N 6.3 ft2 2 ft 4 in 0 ft 5 in Drapes/blinds
0.66 0.35 N 14.0 ft2 6 ft 4 in 0 ft 5 in Drapes/blinds
Exterior 5
Exterior 5
Exterior 5
Exterior 5
GARAGE-
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
492 ft2
492 ft2
66.75 ft 9.33 ft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50)
.000415
2924.8 160.57 301.97 .373 7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
2
Electric Heat Pump/
Electric Heat Pump/
Split
Split
HSPF:8.9999 47 kBtu/hr 1
HSPF:8.9999 18.8 kBtu/hr 2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit/
Central Unit/
Split
Split
SEER: 16 47 kBtu/hr 1410 cfm 0.75 1
SEER: 16 18.8 kBtu/hr 564 cfm 0.75 2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
1
Electric Heat Pump
Garage
2.4 50 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
i None None
ft2
DUCTS
#
-- Supply ---
Location R-Value Area
-- Return --- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
2
Attic 6 394.8 ft
Attic 6 142.6 ft
Attic
Attic
98.7 ft2 Default Leakage Attic (Default) (Default)
35.65 ft Default Leakage Attic (Default) (Default)
1 1
2 2
9/21/2018 9:49 AM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 4 of 5
FORM R405-?_017
TEMPERATURES
Progr1amable Thermostat: Y
Ceiling Fans:
Heat Heating Jan
Feb
Mar
Apr
I
May ri
I
Jun
X Jul
JXJ
Aug
Sep
XJ Sep
0
Oct
Nov
Nov
Dec
HDecVenting
Jan
Feb
l�J Mar
Apr
May
Jun
Jul
lAug
lX
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78-
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68.
68
68
68
68
68
68
68
66
66
MECHANICAL VENTILATION
Type
I
Supply CFM
Exhaust CFM
Fan Watts
HRV
Heating System
Run Time Cooling System
Runtime
Vent
58
0
0
0 1 - Electric Heat Pump
%
1 - Central Unit
9/21/2018 9:49 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5