HomeMy WebLinkAboutEPL DISPLAY CARDFORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 91
The lower the EnergyPerformance Index, the more efficient the home.
i
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft')
7. Windows" Description
a. 6-Factor., Dbl, U=0.66
SHGC: SHGC=0.35
b. 6-Factor: Dbl, U=1.01
SHGC: SHGC=0.50
c. Ui Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. Floor Over Other Space
c. N/A
3906 Dune Side Drive, Fort Pierce, FL,
New (From Plans) 9. Wall Types
Insulation
Single-family a. Concrete Block - Int Insul, Exterior
R=4.1
b. Frame - Wood, Exterior
R=13.0
1 c. Frame - Wood, Adjacent
R=13.0
d. N/A
R=
C'
�040
Area
2972.70 ft'
149.33 ft2
79.33 ft2
ft2
10. Ceiling Types
Insulation
Area
No
a. Roof Deck (Unvented)
R=20.0
1261.00 ft'
2687
b. Roof Deck (Unvented)
R=20.0
713.00 ft'
c. N/A
R=
ft2
Area
11. Ducts
R ft'
307.92 ft'
a. Sup: Attic, Ret: Attic, AH: Attic
6 394.8
b. Sup: Attic, Ret: Attic, AH: Attic
6 142.6
216.00 ft'
12. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
47.0
SEER:16.00
b. Central Unit
18.8
SEER:16.00
ft'
13. Heating systems
kBtu/hr
Efficiency
a. Electric Heat Pump
47.0
HSPF:9.00
4.305 ft.
b. Electric Heat Pump
18.8
HSPF:9.00
0.412
Insulation
Area
14. Hot water systems
Cap:
50 gallons
R=0.0
1974.00 ft'
a. Electric
EF: 2.4
R=0.0
713.00 ft'
R=
ft2
b. Conservation features
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Constrt.Iction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code gompliant features.
Builder Signature: Date:
Address of New Home olp City/FL Zip: �� g
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
9/21/2018 9:49 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1