HomeMy WebLinkAboutLETTER ABOUT VENTILATION CALCULATIONSj 4V DEL -AIR HEATING • MR CON13MONING f 3&0t,-o44qC) December 20, 2019 ATTN: St. Lucie County, FL Dept. of Building & Code Regulation Division RE: Phoenix Homes Realty Inc. - Lot 32 Tarpon Flats The mechanical ventilation calculations as required by 2017 FBC Mechanical, 61' Edition Chapter 401.2 for Lot 32 Tarpon Flats are designed per code and shall follow these parameters as described as proposed in the 2017 FBC — Energy Conservation, 6th Edition Chapter 4, not to exceed .01 x CFA + 7.5 x(Number of Bedrooms +1): Living Square Footage: 2687 Number of Bedrooms: 3 +1 = 4 SCANNED .01 x 2687 = 26.87 BY 4 x 7.5 = 30 St Lucie County 26.87 + 30 = 56.87 CFM This method is also within compliance with the simplified 2017 FBC M1507.3.3(1) Chart as listed below: DWELLING UNrr FLOOR AREA (square feet) NUMBER OF BEDROOMS 0-1 2-3 4-5 6-7 >7 Airflow in CFM < 1,500 30 45 60 75 90 1,501— 3,000 45 L69 75 90 105 3,001— 4,500 60 75 90 105 '120 4,501— 6,000 75 90 105 120 135 6,001— 7,500 90 105 120 135 150 > 7,500 105 120 135 150 165 Del -Air designed and installed a 6" diameter fresh air ventilation intake including mechanical damper, control, and shut off to handle code mechanical ventilation requirement, when a residential building's envelope tests below 3ACH50. Sincerely, Corporate Headquarters 531 Codisco Way Sanford, Florida 32771 Statewide (888) 831-COOL (2665) Fax (407) 333-3853 www.Delair.com State Lic. CAC032448