St. Lucie County
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
Phone:772-462-2165 Fax:772=462-6443
BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
110'� -0(,e-7Z)
ruction: ( �11ew Construction —Complete ( - ) Existing — After Addition
House Infiltration Test Results SLC Climate Zone 2
CFM (50) _ - lS% Test Date:
Volume = ! Z (,9 3 �-
ACH (50) = CFM (50) x 60 / Volume = M--echha�a ical Ventilation required less than 5 ACH
PasIsing results must be & ACH (50) or less (Ss ( ) Fail .
FBC, Energy
The uilding or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 2 air changes per
hou I in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3. through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals), Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or*(!) or an
approved third party. A written report of the results of the test shall be signed by the parry conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
Where the air infiltration rate of a dwelling'unit is less than 5 air -changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in'accordance with Section M1507.3.
%.ompany
ny Namg: �l[h (5 AkKee 5 Address: —7'7C W� `1 P%4 �
-by certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
rements in aaeewdance &-it"NXection R402.4.1.2 Climate Zone 2.
Name: 6P1P--Ad A/
#: