HomeMy WebLinkAboutPRODUCT REVIEW AFFIDAVITFILE COPY
Planning & Development Services Department
Building & Regulations Division
Product Review Affidavit
Building Permit # `tcj°i - okc'l C) Owners Name: NVR Inc DBA Ryan Homes Applicant: NVR Inc DBA Ryan Homes
SCANNED
BY
81 Luce County
NVR - Business Use Only
RECEIVED]
OCT 1.8 2018
Permitting Department
St. Lucie County, FL
Product
Opening
Design
Pressures
Product
Rated
Design
Pressure
Manufacturer
Model #
Product
Approval
Number
Glass Type
Method of Attachment
Windows
+32.37/-42.62
+50/-60 DP
Ply Gem
Series 4712 Flange
FL 14039.1
non -impact
# 10 Wood Screw with sufficient length to achieve 1-1/4" embedment. Required anchors: Head (3), Jamb (3)
Mullions
N/A
+/-75 DP
Ply Gem
Series 4700 Flange
FL 15264.2
N/A
Use %" Tapcon with sufficient length to achieve a 1 %" min. embedment with 2 W' minimum edge distance
Fixed Glass
+29.65/-38.87
+/-55 DP
Ply Gem
Series 4701_Flange
FL 14434.1
non -impact
# 10 Wood Screw with sufficient length to achieve 1-1/4" embedment. Required anchors: Head (3), Jamb (3)
Sliding Glass Doors
+28.74/-42.62
+/-50 DP
Ply Gem
Series 4780
FL 14634.2
non -impact
3/16" Tapcon with sufficient length to achieve 1-1/4" embedment. Required anchors: Head/Sill (6), Jamb (5)
Swing Type Doors
+30.64/-30.64
+67.0/-67.0
Therma Tru
3'011x810"
FL 5891.5
N/A
ITW Tapcon %", Min Embedment 1-1/4", Min Clearance to edge 2", Min Clearance to adjacent anchor 4"; OR ELCO
Tapcon 1/4", Min Embedment 1-1/4", Min Clearance to edge 1", Min Clearance to adjacent anchor 4". Anchor
Spacing Max 18.5" O.0
Garage Doors
+25.91/-31.39
+36/-42
Clopay
160 model 73W6
FL 16546.4
N/A
Jamb to block on vertical jamb 1/4" X 11/4" rein embedded Tapcon. Max spacing of 71/2" and 1" OD steel washer
required.
Hurricane Protection
N/A
+40/-40
Eastern Metal
24ga Steel Panels
FL 11964.2
N/A
1/4" Tapcon Anchors, SG Tapcons or 1/4" X 3/4". All points Solid -set Anchors.
Roofing Material
N/A
N/A
Tamko
N/A
I FL 18355.1
N/A
Soffits (Panel Walls)
N/A
N/A
Ply Gem
Mastic Soffits
I FL 23352.1
N/A
Structural Component
N/A
N/A
Huber Eng.
ZIP System
I FL 1.7147.1
N/A
I have reviewed the above components or cladding and I have approved the
Name: James Joseph Cantwell Signature:
Design Prof: Architect Cert. No. AR0012079 Date:
in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions.
seal
Building Permit #
Planning & Development Services Department
- Building & Regulations Division
Product Review Affidavit
VOID
Owners Name
Applicant:
Product
Opening Design
Pressures
Product Rated
Design Pressure
Manufacturer
Model Number
Product Approval
Number
Glass
Type
Method of Attachment
Windows
+32.37/-42.62
+50/-60 DP
Ply Gem
Series 4712 Flange
FL 14039.1
Non -Impact
# 10 Wood Screw with sufficient length to achleve 1-1/4'embedment Required anchors: Head(3), Jamb(3)
Mullions
N/A
+/-75 DP
Ply Gem
Series 4700 Flange
FL 15264.2
N/A
Use 1/.' Tapcon with sufficient length to achieve a t'/.' minimum embedment with 2'/a' minimum edge distance.
Fixed Glass
+29.65/38.87
+/-55 DP
Ply Gem
Series 4701 Flange
FL 14434.1
Non -Impact
It 10 Wood Screw with sufficient length to achieve l-1/4'embedment. Requlred anchors: Head(3). Jamb(3)
Block Glass
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Skylights -
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Sliding Glass Doors
+28.74/-42.62
+/-50 DP
Ply Gem
Series 4780
FL 14634.2
Non -Impact
3/16'Tapcon with suffic-t length to achieve 1-1/4- embedment. Required anchors: Head/Slil(6). Jamb(5) Each window.
Swing Type Doors
+30.64/-30.64
+67.0/-67.0
ThermaTru
3'0-X8'0' Smooth Slar Fiberglass
FL5891.5
N/A
nwTepmn W, Min Embedment 1-1/4'. Mtn clean —to edge T. Min clearance to edjawnt ancmxr 4'; OR EIDO Tapcn 1/4'. Min
French Doors
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Garage Doors
+25.91/-31.39
+36/-42
Clopay
16X7 Model 73W6
FL16546.4
N/A
Jamb to block on-tical jamb 1/4'X11/4- min embedded Tapcon. Max spacing of 7112' and l'OD steel washer required.
Hurricane Protection
N/A
+40/-40
Eastern Metal Supply
24ga Steel Panels
FL 11964.2
N/A
1/4" Tapcon Anchors, SG Tapcon or 1/4" X 3/4". All points Solid -set Anchors.
Roof Ventilation
N/A
Roofing Material
N/A
N/A
Tamko
N/A
FL18355.1
N/A
6 nails par shingle. Standard type tooling nad, nail shanks should be 12 gauge wire and minimum heetl or 3/60.
Revised 07/22/2014
I have reviewed the above componedtm: jL',ddjWnd hh1ave approv ''1'i
wind loads and forces specified by cure ` e provisions.
Name: JAMES JOSEPH CANTWELL Signature:
Design Prof: ARCHITECT Cert. No. AR0012079
These products provide adequate resistance to the
06/26/18
seal