Loading...
HomeMy WebLinkAboutBLOWER DOOR TEST CERTIFICATION - 1-24-19Planning & Development Services ' Building & Code Regulation Division Rebell/ _ D 2360 Virginia Ave, Rm 201 J F • a • Fort Pierce, FL 34992 Phone:772-462-2165 Fax:772-462-6443 Gc peps 19 �' Coo Y ent BLOWER DOOR TEST FORM ...... , .....��, :, _...1 Houser-Fnfiltration Test -Certification :,,.,,.:..._� v,:.,W .......... Prescriptive'and Performance Method Date: 03 D A Permit #: S�G CAA)"ED Contra r: R6A es R`',I<'L" Ig y Job Address: '�� �31L�Ghi� Construction: ( %--rNew Construction — Complete ' ( ) Existing•— After Addition ;e Infiltration Test Results SLC Climate Zone 2 (50) = I�/ Test Date• 1 3 o�di me =. / r (50) = CFM (50) x'60 / Volume = 5 •iGi7` Mechanical Ventilation required less than 3 ACH ng results must be & ACH (50) or, less ( ) Pass ( Fail FBC, Energy The Building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2. and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door -at a pressure -of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7). Florida Statutes or individuals licensed asset forth in Section 489.105 (3)(f),. (g) or (!)or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and_ provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, (tesidential WheOe the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with.a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Company Name: 15 Lightyears INC Address: 776 Bennet Drive Longwood FI 32750 I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance wi tion R402.4.1.2 Climate Zone 2. Printed Name: 6A1,1 /DYles License Certification #: "-7 ! 6- 7 RECEIVE® JAN 2 4 1019 Permitting Department St. Lucie County Certificate of Achievement THIS ACKNOWLEDGES THAT Will Torres HAS MET THE STANDARD REQUIRED. BY RESNET, AS A CERTIFIED HOME ENERGY RATER RT IN # 9704654 Certification Date: November7, 2018 Certification Expires: November 7, 2021 Tim Smith, RESNET Quality Assurance Designee h-t- "w" RESNET QA Provider # (1998-199)