Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEi FORM IR405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 004 F1452 B LHG - E Builder Name: Ryan Homes 6Q4&/ �N Street: 5202 Oakland Lake Cir. Permit Office: St. lucie • City, State, Zip: Port St. Lucie. , FL, Permit Number: Jurisdiction: 661000 y C Owner: �U�l� Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2) 1. New construction or existing New (From Plans) 9. Wall Types (1516.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1265.30 ft2 b. Frame - Wood, Adjacent R=11.0 251.33 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Numbelr of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1452.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1452.00 ft2 6. Conditioned floor area above grade (ft2) 1452 b. N/A R= ft2 Condit oned floor area below grade (ft2) 0 . N/Aucts R_ z 11. R ft2 7. Windows(132.0 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 290.4 a. U-Factor: Dbl, U=0.54 98.67 ft2 SHGC: SHGC=0.31 b. U Factor: Dbl, U=0.63 33.33 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a. Central Unit 23.2 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 23.2 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.313 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1452.0 sqft.) Insulation Area EF: 0.900 a. Slab, On -Grade Edge Insulation R=0.0 1452.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 49.85 Glass/Floor Area: 0.091 PASS Total Baseline Loads: 51.01 1 herebylIcertify that the plans and specifications covered by Review of the plans and 4JaE SST this calcOation are in compliance with the Florida Energy specifications covered by this �y0 �O Code. calculation indicates compliance�� with the Florida Energy Code. h n�„���''`;;�• ��„ PREPARED BY: DATE: O. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - * n ¢ I herebylcertify that this building, as designed, is in compliance S� with the iFlorida Energ ZCdOWNER/AGENT:J'�� BUILDING OFFICIAL: DATE: P��"-t - t DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 On for whole house. 8/15/2618 11:14 AM EnergyGaugeO USA Section R405.4.1 CF It Loft Ere COPY Page 1 of 4 FnRM Rang-9n17 INPUT SUMMARY CHECKLIST REPORT i PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Commenit: Lot 004 F1452 B LHG - E Bedrooms: 3 User Conditioned Area: 1452 Total Stories: 1 1 Worst Case: No Ryan Homes Rotate Angle: 270 St. lucie Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Lot Information Lot # 004 Block/Subdivision: PlatBook: Street: 5202 Oakland Lake Cir. County: St. Lucie City, State, Zip: Port St. Lucie. , FL, CLIMATE V Design Location i Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 I Blockl 1452 12632.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1452 12632.4 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 146 ft 0 1452 ftz ---- 0.29 0 0.71 ROOF # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Emitt Deck Pitch Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1530 ft2 242 ftz Dark 0.6 N 0.6 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1452 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type i 1 Under Attic (Vented) Main 30 Blown 1452 ftz 0.1 Wood 8/15/2 i 18 11:14 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 1=nrw FtanF_9n17 INPI IT SUMMARY CHECKLIST REPORT i WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 1E=>N Exterior Concrete Block - Int Insul Main 4.1 47 6 8 8 411.7 ftz 0 0 0.6 0 2 S=>E Exterior Concrete Block - Int Insul Main 4.1 21 0 8 8 182.0 ftz 0 0 0.6 0 3 IW=>S Exterior Concrete Block - Int Insul Main 4.1 37 6 8 8 325.0 ftz 0 0 0.6 0 4 N=>W Exterior Concrete Block - Int Insul Main 4.1 40 0 8 8 346.7 ftz 0 0 0.6 0 5 =>SW Garage Frame - Wood Main 11 29 0 8 8 251.3 ftz 0 0.25 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In j 1 S=>E Wood Main None .39 3 6 8 20 ftz 2 - >SW Wood Main I None .39 2 8 16 ftz WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 270 degrees). Wall Overhang V 1# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E=>N 1 Metal Low-E Double Yes 0.54 0.31 N 16.4 ftz 1 ft 0 in 2 ft 0 in Drapes/blinds None 12 S=>E 2 Metal Low-E Double Yes 0.54 0.31 N 16.4 ftz 1 ft 0 in 2 ft 0 in Drapes/blinds None 3 W=>S 3 Metal Low-E Double Yes 0.54 0.31 N 16.4 ftz 1 ft 0 in 2 ft 0 in Drapes/blinds None 4 N=>W 4 Metal Low-E Double Yes 0.54 0.31 N 49.3 ftz 1 ft 0 in 2 ft 0 in Drapes/blinds None 5 N=>W 4 Metal Low-E Double Yes 0.63 0.32 N 33.3 ftz 1 ft 0 in 2 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation- 1 393 ftz 393 ftz 58 ft 8.7 ft 1 i INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Who lehouse Proposed ACH(50) .000387 1473.8 80.91 152.16 .2875 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.2 23.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts i 1 Central Unit/ Split SEER: 14 23.2 kBtu/hr 696 cfm 0.75 1 sys#1 8/15/2018 11:14 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4 i FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 290.4 ft Main 72.6 ftz Prop. Leak Free Main --- cfm 43.6 cfm 0.03 0.50 1 1 TEMPERATURES Progra able Thermostat: Y Ceiling Fans: Cooling((jj Jan �jj Feb Mar Heatin[X] Jan [X] Feb Mar A r APr j Ma jjX] Jun jXj Jul ] May [ ] Jun j ] Jul Xj AugjXj 4 ] AuE Se ] Seep j j [ ] Oct j j Oct [X] Nov Nov Dec Dec LX} Venting[ ]] Jan [[ ]] Feb lxl Mar Apr l ] May [[ ] Jun [ ] Jul l l ] Aug ] Se [X] Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (i D) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 Main Name: Test Rater Rating Compant: Test Rater Signature: Date: 8/15/2018 11:14 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4 Florida Building Code, Energy Conservation, 6th Edition (2017) atory Reauirements for Residential Performance, Prescriptive and ERI Methods I ADDRESS: 5202 Oakland Lake Cir. Permit Number: I Port St. Lucie. , FL, MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL ❑R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. ❑ R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal enveloybe building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Instal lation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third parry shall inspect all components and verify compliance. i R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through B. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. ❑R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. 1 R402.4.3 Fenestration air Ieakage.Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 8/15/2018 11:15 AM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) I R402A4 Rooms containing fuel -burning appliances. In Climate Zones 3-through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. El R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls !that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. R4013.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.i5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C) or below 55°F (13°C) shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. ❑ R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return j pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 8/15/2018 11:15 AM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) I R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 31/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F (38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main bumer(s) of combustion types of service water -heating systems to be turned off. R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that ,close when the ventilation system is not operating. R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. Fi R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3• If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM (CFM) MINIMUM EFFICACY a (CFM/WATT) AIRFLOW RATE MAXIMU (CFM) Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt <90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916 8/15/2018 11:15 AM EnergyGauge@ USA - FBC 6th Edition (2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) ❑R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. Thel published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R4 I3.7.1.2 Heating equipment capacity. ❑ r403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. ❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections ❑ C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. ❑ R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C). ❑ R403I10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas !shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. ❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this I section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. ❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal ❑ efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 8/15/2018 11:15 AM EnergyGaugeO USA - FBC 6th Edition (2017) Compliant Software Page 4 of 5 ❑ R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.,11 Portable spas (Mandator%he energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. j SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404 1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. , Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 8/16/2018 11:15 AM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. i 1! New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Sin lele�ly b) Return ducts R 6.0 c) AHU location Attic/Main 3. No. of units (if multiple -family) 4. Number of bedrooms 5i Is this a worst case? (yes/no) 6.I Conditioned floor area (sq. ft.) 7. Windows, type and area a) U-facto r: (weighted average) b) Solar Heat Gain Coefficient (SHGC) c) Area 81 Skylights a) U-factor:(weighted average) b) Solar Heat Gain Coefficient (SHGC) 9, Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 4. 3 13. Cooling system: Capacity 23.2 a) Split system SEER 14.0 5. No b) Single package SEER c) Ground/water source SEER/COP 6. 1452 d) Room unit/PTAC EER e) Other 7a. 0.563 7b. 0.313 7c. 132.0 8a. NA 8b. NA 9a. 0.0 9b. 9c. 10. Wall type and insulation: A. Exterior: 1 1. Wood frame (Insulation R-value) 10A1. 2. Masonry (Insulation R-value) 10A2. 4.1 j B. Adjacent: 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 11. Ceiling type and insulation level a) Under attic 11 a. 30.0 b) Single assembly 11 b. c) Knee walls/skylight walls 11c. d) Radiant barrier installed 11 d. No 14. Heating system: Capacity 23.2 a) Split system heat pump HSPF 8.2 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.90 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans b) Cross ventilation No c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. i I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. e� Builder Signature: CA� N�`-lam`" � Date: a. l'1 -1 g Address of New Home: 5202 Oakland Lake Cir. City/FL Zip: Port St. Lucie., FL 8/15/20I 8 11'14:48 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Lot 004 F1452 B LHG - E Builder Name: Ryan Homes Street: 5202 Oakland Lake Cir. Permit Office: St. lucie City, State, Zip: Port St. Lucie. , FL, Permit Number: Y U Owner: Jurisdiction: 661000 w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim jo'sts Rim joists shall include the air barrier. Rim joists shall be insulated. Floors) The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. ,Crawl 'space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation j a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on Narro cavities installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pip*no and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVACregister boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snronkler rover niates and walls or ceflinas. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 8/15/20118 11:15 AM EnergyGauge@ USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 Wrightsofte Project Summary Entire House - One Stop Cooling and Heating 7225 Sardscove Cau t, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCoolirij.com License: CAC032444 For: Ryan Homes Notes: Job: Lot 004 F1452 B LHG - E Date: 10/1912015 By- RULF Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 68 OF Inside db 74 OF Design TD 26 OF Design TD 16 OF Daily range M Relative humidity 50 % Moisture difference 64 gr/lb Heating Summary Structure 15406 Btuh Ducts 1426 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 16832 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 He it459 Co ipq ea f12 11453 lume)(ft3) 12639 12639 AI ang ir chesmour 0.45 0.23 Equiv. AVF (cfm) 95 48 Heating Equipment Summary Make Goodman Mfg. Trade GOODMAN; JANITROL; AMANA DISTI... Model GSZ140241 K AHRI ref 7995055 Efficiency 8.2 HSPF Heating input Heating output 23200 Btuh @ 47OF Temperature rise 0 OF i4ctual airflow 0 cfm Air flow factor 0 cfm/Btuh Static pressure 0.50 in H2O Space thermostat apacity balance point = 35 OF Backup: Input = 9 kW, Output = 29982 Btuh,100 AFUE Calculations Sensible Cooling Equipment Load Sizing Structure 14191 Btuh DucCentral 2830 vent (0 cfm) Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swin multiplier Equipmenq sensible load 0.95 16176 Btuh Latent Cooling Equipment Load Sizing Structure 2894 Btuh Ducts 738 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 3632 Btuh Equipment Total Load (Sen+Lat) 19808 Btuh Req. total capacity at 0.75 SHR 1.8 ton Cooling Equipment Summary Make Goodman Mfg. gANITROL; Trade GOODMAN; AMANA DISTI... Cond GSZ140241 K Coil ARUF251314A AHRI ref 7995055 Efficiency 11.5 EER,14 SEER Sensiblecooling 17400 Btuh Latentcooling 5800 Btuh Total cooling 23200 Btuh Actual airflow 773 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.82 ACCAto meet all requirements of Manual J 8th Ed. wriahts nft- FGgtt-SUte@)Uriversal20l8 l8.0.19 RSU16877 1Desldop\TEMP PRINT\Lot 004 F1452 B LHG - E.n 3 Calc = W8 Front Door faces: E 2018-Aug-1511:10:54 Page 1 - wrightsoftRight-J® Worksheet Entire House One Stop Cooling and Heating 7225 Sardsoove Court, Winter Park, FL 32792 Plane: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopCoolirg.mm Licerse: CAC032444 Jab: Lot 004 F1452 B LHG - E Date: 10/19/2015 By: RULF 1 2 3 4 5 Room name Eiuosed wall Room height Room dimensions R000m area Entire House 146.0 ft 8.7 ft d 1452.8 fF DIN 20.5 ft 8.7 ft heaVmol 11.0 x 9b ft 104.5 fP Ty I Construction number U-value (BhuWF) Or HTM (Btu fuAR) Area (fF) or perimeter (ft) Load (Bhuh) Area (fF) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/DS Heat Cool 6 11 yV►11 } _-G ' --G r '-D W C- �G _l. C 13A 4as - - - -4A5.2db__-T - 13A-4o s 4A5-2ob 11 DO _ _ 13A 4aGs 4A5-2ob 4A5-2obd 11D0! ___ ___ 16B-30ad - 0.143 _-0.540 0.143 0.540 _0.390 - 0.143 - _- 0 W 0.143 0.540 0.630 0.091 _ 0.390 0.032 n .-n_ a a a s -s- w w w 3.72 _.14D4 3.72 14.04 10.14 _ 3.72 _,14A4 3.72 14.04 16.38 -~'233 13.57 413 16 397 0' :307 ---0 0 0 0 0 '_-•_0 231 0 549 ' - .- -- 0 _--0 87 193 --.----0 0 0 _ 0 -0 . -------0 145 0 12.36 0 _ -_-0 171 1476 229 925 222 63 0 83 --0 0 0 0 _ 0 0 --_0 2.33 34.61 10.72 183 16 20 146 0 20 544 229 204 341 566 216 0 0 0 - 233 1357 2.33 34.61 36.89 - 326 1.6 348 49 34 � �3i0 16 i152 229 987 688 549 '--"-722 10 ' 222 -- 0 0 265 0 0 619 1697 1236 96 0 34 62 0 0 - ' 6 _ --0 105 _n- 237 10.14____10.72 0.83 ,'-- 1.15 1.63 _ ' 252 16 1453 _ - 236 16 559 162 1209 271 1.72 2371 _ 0 0.- 1453 105 F _ -- _ 22-:q-xn_- _ � - - i.180 _. 3U,6t3. -`�0.00 1453 146 4479 0 -- 105 a 6 c) AED excursion 1141 572 Ernelope loss/gain 12697 107191 1803 2316 12 a) Infiltration b) Room ventilation 2709 1 0 852 0 380 0 120 0 13 Intemalgains: Occupants@ 230 Applianceslother 4 920 1700 0 0 0 Subtotal (lines 6to 13) 15406 14191 2183 2435 14 151 Lessextemalload Less transfer Redisbibution Subtotal Duct loads 1 9'/0 20%1 0 0 0 15406 1426 0 0 0 14191 2837 9°/, 20°/, 0 0 0 2183 202 0 0 0 2435 487 Total room load Air required (cfm) I I 16832 1 01 17027 773 2386 01 2922 133 -Ft*- 2018-Aug-1511:1054 Righ-Sute®Universal201818.0.19 RSU116877 Page 1 \Desldop\TEMP PRINT\Lot 004 F1452 B LHG - E.rrup Calc= MJ8 Front Door faces: E I- irightsofr Right-J® Worksheet Entire House One Stop Cooling and Heating 7225 Sandscove Court. Winder Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCoalirg.com License: CAC032444 Job: Lot 004 Ft 452 B LHG - E Date: 10/19/2015 By. RULF 1 2 3 4 5 Room Room Room Room name 'F�oscdvdl height dimensions area GREAT 14.0 ft 8.7 ft heaVaool 1.0 x 298.0 ft 298.0 fF NEED 30.0 ft 8.7 ft heat/aool 1.0 x 227.0 ft 227.0 1R Ty Construction number U-value (Bluh4 i--F) Cr HTM (Btuh&F) Area (ftz) or perimeter (ft) Load (Btuh) Area (fF) or perimeter (ft) Load (BWh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 V�l 4--(' 13CA .- ^0.143 ��0.143 0.140 0.390 in a ye a 3.72 3.04 14.72 10.14 v 3.72 - 14.04' 3.04 14.04 16.38 237 .�101_4 0.83 =30.68 - 2.33 �32.61 10.72 " 2 33 = 13.57 34.61 4.61 36.89 1.15 --10.72 1.63 _=U0 0 0 0 �O 0 ---0 133 33 0 `- _ . O i__ 0 - r O 00 - - ;0 0 O 0 0 s e-0 . 0. 0 0 --. a : - _ _ O 0 0 y! )I �- - 13A-flocs 4A5.2oc 11 DO - 0- 0 --0 0 _ 89 0 O 298 14_ 0 0 0 131' ' 1.6 11 16 0 0 227 0 0 - 114 16 - 114 0 0 0 ______0 227 0 O 0 1-DG 1111 ��13A4A5 { 13A 9ocs 4A5-2ob - 4A5-lob flocs T ~ 4A5-2obd -f �nr ,11D0� _ 16B-30ad _ 22A_-cpn- . 0143 0.540 0.540 P 0.143 0.630 OA91 U390 0.032 1.1B0 s s.- w w w --- n� _ :--'--0 231 1131 0 _ _ . p 486 424 229 224 229 0 v 0 01 256 222 566 566 0 459 - 4 45 _ 0 248 430 �- �` C F '.:-D 0 0. 370 298 _: �-=298 189 _ _0a-__ �227 =® 30 -_920 -0. - - 61 c) AED ewarrsion 537 129 Ernelope loss(gain 1468 2362 24171 1819 12 a) b) Infiltration Room ventilation 260 0 82 0 557 0 175 0 13 Ir6malgains: Caupants@ 230 Applianaes/other 0 0 0 2 460 0 Subtotal (lines 6to13) 1727 2443 12974 2455 14 15 Lesextemalload Less Redistibution Subtotal Dud transfer loads 9%1 20% 0 0 200 1927 1781 0 0 311 2755 551 91/6 201/6 0 0 0 2974 275 0 0 0 2455 491 Total Air room load required (dm) 2105 0 3306 150 3249 1 01 2945 134 ACCAto meet -FW 2018-Aug-1511:1054 Right-Suite®Uriversal 201818.0.19 RSU16877 Page 2 \Desldop\TEMP PRINT\Lot 004 F1452 B LHG - E.n 3 Calc = W8 Frond Door faces: E wrightsoft Right-J® Worksheet Entire House One Stop Cooling and Heating 7225 Sar dscove Coat, Wirter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCoolirg.com License: CAC032444 Jab: Lot 004 F1452 B LHG - E Date: 10/19/2015 By: RI/LF 1 2 3 4 5 Room name Eiposed wall Room height Room dimensions Rbom area Kff 9.0 ft 8.7 ft heaUcool 1.0 x 126.1 It 126.1 fF PAN 4.0 ft 8.7 ft heaUmol 1.0 x 16.9 ft 16.9 fF Ty Construction number U-value (Btuh/ftz--F) Or HTM (BIuhITR) Area OF) or perimeter (ft) Load (Btuh) Area (12) or perimeter (ft) Load (BWh) Heat Cool Goss NIPlS Heat Cool Goss N1P15 Heat Cool 6 11 - y/ �j I—C L— D .r !! --G y! �L 'TCG - q C F 13A 4ois -4A5-2ob --_ _ _ -- 13A-4ocs 4A5-2ob 11 DO 13A flans - -• - 4A5-2ob -_= _ __r _ _. 13A-4ocs 4A5-2ob 12C 05uv - 11D0_ _._�.--0390_n_. 16B-30ad 0.143 0.590 0.143 0.540 0.390 0.143 _ —_ 0.540 0.143 0.540 0.091 _ 0`032 n n. _ `e a a - s - _s_ w w = 3.72 — 14.04, 3.72 14.04 10.14 - : 372 14.0.4, 3.72 14.04 237 10._-072 14 :FM .�-.1357 2.33 34.61 10.72 = 2188 r].357 2.33 34.61 1.15 1.63 --.___0 ' 183 - —. 35 __-. 0 0 0 0 - 129 0 0 0 _ _Bi 0 0 0 _ •_ _0. 0 0 _-- - 0 " 78 0 78 ._._._-__ O 0 0 0 291 _ 0 0 0 0 0 0 0 0 0 0 0 0 0 _` p _0 0 0 ' 0 0 p . _0 0 __O 0 0 0 —0 206 -- 0 0 — — 0 . 0 0 0- 0 0 0 0 0 0 0 _ 0 17 0 0 0 --00 0 0 �_ 0 0. 0 0 6 126 126 —0 105 17 14 -- 28 -- - 0 _-0.83 SOM —_0.06 126 _ 9 276 _ , 0 :-_ 17 _ _4 _�� 123 6 c) AED excursion -62 -5 Elope loss/gain 672 326 266 104 12 a) Infiltration b) Room ventilation 167 0 53 0 74 0 23 0 13 Iritemalgain. Ooatpants@ 230 Applianoes/other 0 0 1200 0 0 0 Subtotal (lines 6 to 13) 839 1579 340 127 14 15 LessexGemalload Lesstransfer Redistribution Subtotal Duct loads 90/0 20% 0 0 3 842 78 0 0 6 1584 317190/0 201/6 0 0 0 340 32 0 0 0 127 25 Total room load Air required (cfm) 920 0 1901 86 372 0 152 7 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. t wrigl �tsoft- 2018-Aug-1511:10:54 ACt .A Rigtt-Sdte®Uriversal 201818.0.19 RSU16877 Page 3 \Desktop\TEMP PRINT\Lot 004 F1452 B LHG - E.rrp Calc = WB Front Door faces: E -�- vtirightsofV Right-J® Worksheet Entire House One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopCoolirg.com Lioerse: CAC032444 Jab: Lot 004 F1452 B LHG - E Date: 10/19/2015 By: RI/LF 1 2 3 4 5 R6m name Eiposed wall Room height Room dimensions Room area M✓VIC O ft 8.7 It heaU000l 8.0 x 7.0 ft 56.0 fF METH 12.0 ft 8.7 ft heaUmol 1.0 x 107.5 ft 107.5 i' Ty Construction number U-value (Btuh/ftz°F) Or HTM (BtuhHtz) Area (W) or perimeter (ft) Load (BWh) Area (ft2) or perimeter (ft) Load (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P5 Heat Cool 61. 11 LLL���ppp t-C ![- L_(v '-D C F I 13A�ors: _4A5.2ob • - 13A-lob 4A5-lob 11 DO _ f3-A ors -4A52ob- 13A-4ors 4A5-2ob 4A5-2obd 12C Oanr_ �- _11.D0 - - 16EMOad �0143 0.540 0.143 0.540 0.390 0.143 .Y0.540 0.143 0.540 0.630 0 -- 0.390 0.032 n. --n- a a a s . _s-'-14.04 w w w -n- - - 3 14D-4 3.04 14.04 10.14 - 3.72 3.72 14.04 16.38 237 _ 1014 0.83 -- __1357 _ 4.61 34.61 10.72 2.33 -13.57 2.33 34.61 36.89 - 15 1.091 _ 10.72 1.63 _ 0--0 - e-_0 0 0 0 _ _ 0 0 0 0 _ __.. _ 0 �_._-0 M 56 _56 0 -�-0 0 0 0 _ 0 0 0 0 0 -- 165 47 0 0 0 6 _ ._ .-0 0 0 0 B 91 0 0 0 0 0 0 0 0 0 '� 988 _0 0 0 0 ` -- 154 89 0 0 0 243 0: 0 0 _ 0 75 175 0 0 0 0 -____0 0 0 0 .__. - _ 70 0 - 104 ��___0 0 0 , -.. 0 108 T 104 .-�_.__0 0 0 0 - ,65 108 _12 . y 56 0108 22A 1.180_ a _ 30.68 ;y __ U.00 �- __�368 y_ - Q 6 c)IAED excursion -6 -21 Elwelopeloss/gain 211 1651 1000 472 12 a) Infittration b)1 Room ventilation 0 0 0 0 223 0 70 0 13 Intemalgains: Ooarpanls@ 230 Appliances(other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 211 165 1223 542 14 15 Less e)dmalload Lesstransfer Redistribution SUbtotal duct loads 9% 20% 0 0 62 273 25 0 0 369 533 107 9% 20% 0 0 0 1223 113 0 0 0 542 108 Total room load PJr required (cfm) 298 01 640 291 1336 0 651 30 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -- wrigtitsoitm 2018-Aug-1511:10:54 " "' """ -^ - RigYt-Sute®Uriversal 201818.0.19 RSU16877 Page 4 \Desldop\TEMP PRINT\Lot 004 F1452 B LHG - E.np Calc = W8 Frond Door faces: E i, ,rightsoft- Right-J® Worksheet Entire House One Stop Cooling and Heating 7225 Sandscove Cout, W inter Park FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www0reStc)pCoolirg.com License: CAC032444 Jab: Lot 004 F1452 B LHG - E Date: 10/19/2015 By: RI/LF 1 2 3 4 5 Room name EVosedwell Room height Rbom dimensions Room area O ft 8.7 ft heat/owl 5.5 x 4.0 ft 22.0 1 BTH2 0 8 8.7 ft heat(cool 55 x 85 ft 46.8 F Ty I Construction number U-value (Btuh/fPF) Or HTM (BUMP) Area MI) or perimeter (ft) Load (Bluh) Area (fF) or perimeter (it) Load (Btuh) Heat Cool Gross NIPS Heat Cool Gross N/Pra Heat Cool 6 11 y/ _ I - `,. G 13A-4ocs 4A5-2ob-_ .----- - 13A-4ocs 4A5-2ob 11DO - 13A-flocs 13A-4ocs 4A5-2ob 4A5-2obd 12C-0sw 16&30ad_ 22A cam 2. 0.143 --- _-0540 0.143 0.540 - 0290 0:143 _0.590 0.143 0.540 0.630 0.091 0390 0.032 _ 1.180 63.72 ---n - a a _e s _ s_ w w _w ` - __n-- _ . 14.04 3.72 14.04 - 10.14 ' 3.72 __ 14.04. 3.72 14.04 16.38 237 _ 10.14.'_ 0.83 30 G8, 233 --113- 7 2.33 34.61 10.72 233 1357 2.33 34.61 3.6.89 ' 1.15 10.72 1.63 ,... ,0.0022 -- z 0 -----:-0 0 0 -- 0 0 ____--0 0 0 0 - ` 0 _ _-- -0 22 - 0 . D 0 0 0 0 � 0 -- —,-_0 0 0 0 0 0 0 0 0 0 0 0 - 0 —0 0 0 0 0 0. 0 0 0 - - 0 ��0 47 _L --0--0 0 0 0 0 0 0 0 0 0 - p 0 -- yJ � 0 - 0 - 0 0 0 _-_0 0 0 0 0 �1 I-=G 0 0 0 - -- 0, 0 0 0 0 .0 00 0 0 0 -- -- 0 — _-0 47 0 0 0 -- - 0 0 0 0 0 ,- - - 0 0 '--G C _ 22 18 36 39 76 . U -0 _ —0 .— 47_ _0 _0. _ 0 - 6 c) AED excursion -1 -3 Envelope loss/gain 18 35 39 73 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Intemalgains: Occupants@ 230 I Appliances/other 0 0 0 0 0 0 Subtotal (lines6 to 13) 18 35 39 73 14 15 Less extemalload 1.6mtransfer Redistribufion Subtotal Duct loads 191/6 20 % 0 0 -18 0 0 0 0 -35 0 0 9% 20°/, 0 0 511 550 511 0 0 369 442 88 Total Air room load required (cfm) 0 0 0 0 601 0 530 24 to meet all reauirements of - wrigF�tsoftp 2018-Aug-1511:1054 Rigtt-SL!te@Uriversal20l8 i8.0.19 RSU16877 Page 5 \Deskop\TEMP PRINTLot 004 F1452 B LHG - E.np Calc= W8 Front Door faces: E I- wrightsoft° Right-J® Worksheet Entire House i One Stop Cooling and Heating 7225 Sardscove Court, Wirter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.0neStopCoofing.com Licerse: CAC032444 Job: Lat 004 F1452 B LHG - E Date: 10/19/2015 By- RI/LF 1 2 3 4 5 Room name EVosed well Ooom height Room dimensions Room area LDRY 0 ft 8.7 ft heaUaool 35 x 7.0 ft 24.5 ftz BED3 14.0 ft 8.7 ft heaUmol 11.0 x 14.0 ft 154.0 fF Ty Construclion number U-value (Btuhrfte-°h� Or HTM (Btu Area (W) or perimeter (ft) Load (Btuh) Area (f(z) or perimeter (ft) Load (Btuh) Heat Cool Gross PUPS Heat Cool Gross N/PS Heat Cool 6 11 13A 4ors ' 0143 -A.590 0.143 0.540 0,390 '- b:143 0540 0.143 0.540 0.630 -^- - 0.�1 -0390 0.032 v n - -n_ a a a s ' -s-. w w w -� _ -n- -- -- 0 0 0 0 0 0 0 -- r - 0 -_--0 0 0 0 - 0 0 - - - 0 -0 0 0 0 --- 0 _. - 0 0 0 0 - �-r _ _0 40 ------- _0 122 - _--16 0 0 0 -- - --- U .__- -0 0 0 _0 ----. 0 _ 0 154 _71.54 - 105 -- - _- 0 0 0 0 - - U - - - --0 0 0 0 . O _ __ -_0 154 ---_ 14 392 --- -229 0 0 0 - - U --- -- --0. 0 0 0 .. .- --0 �_ 0 128 - - 430 - 24ti ----222 0 0 0 '- 3.72 -14.04. 3.72 14.04 10.14 3 .72 -14D4 3.72 14.04 16.38 ---233 -13.57 2.33 34.61 10.72 2.330 -1357 2.33 34.61 36.89 . - 0 --0 0 0 _ 0 0 -mod -M&2ob 13A-4ocs 4A5.2ob 11DO _ 13A-0as 4A5,2ob- - 13A-4ocs 4A5-2ob 4A5-2obd 12C-09v _,..----- 11D0_ 1613-30ad II�-0-0D y/ L ^` --C ---- 0 - --,:--0 0 0 0 0 251 -- 0 0 0 0 � 0 0 0 - 0 �.a. � 0 0 0 _- 0 � _ -0 20 R .a.- -237 10.14 0.83 1.15 10.72', 1.63 C ;- 25 25 i30.68 :=(j.00 -."25 0 0 -_---_ - - - A--- -_-- ---- -- --- _ - -- - - -- - a--__ _ - -- ---- - 6 d� AED excursion -22 -39 Fmelope loss/gain 921 53 1179 680 12 a) Infiltration b) Room ventilation 0 0 0 0 260 0 82 0 13 16malgains: Oocuwls@ 230 Appliances/other 0 0 500 1 230 0 Subtotal (lirres6to 13) 92 553 1439 992 14 151 Less extemalload Lesstransfer Redistribution Subtotal Duct 1 Rol 20% 0 0 -92 0 0 0 0 -553 0 .1 20% 0 0 146 1585 147 0 0 105 1097 219 Total room load Air required (clm) 0 0 0 0 1732 0 1316 60 tD meet all f�&- wr7ghtsoTtm 2018-Aug-1 5 11:10:54 Riga-SUte®Uriversal 201818.0.19 RSU16877 Page 6 Vesldop\TEMP PRINT1Lot 004 F1452 B LHG - E.rup Calc= W8 Frort Door faces: E wrightsoft`° Right-M Worksheet Entire House One Stop Cooling and Heating 7225 San: lscove Court, W irter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCooling.com License: CAC032444 Job: Lot 004 F1452 B LHG - E Date: 10/19/2015 By: RULF 1 2 3 4 5 Room name E�osed well Room height Room dimensions Room area BED2 37.0 ft 8.7 ft heaUeool 15.5 x 11.0 ft 170.5 W FOY 5.5 ft 8.7 ft heaticool 1.0 x 99.0 ft 99.0 it, Ty i Construction number U-value (Btuhfit-°F) Or HTM (BtuW Area (fF) or perimeter (ft) Load (Ehuh) Area (fe) or perimeter (ft) Load (Btuh) Heat I Cool Gross N/PS Heat Cool Gross N/P/S Heat Cool 6 11 y/ L _G W, �L _G I--C hr - - +- C _E=j_ ; i 13A-flocs - - 4A5-2ob--_ - -- 13A-4ocs 4A5-2ob 11 DO 13A-4o'is - - -- =4A5.2ob---. ---- 13A-4ocs 4A5-2ob 4A5.2obd _- ---- 12C-Osuv 1613-30ad 7A oam _- - - - - . _ 0.143 - ___0_W 0.143 0.540 0.390 - - 0.143 _- - - U.540 0.143 0.540 - - - -0:630 0.091 0.390 0.032 . _ 1.180 .n __n__ a a a -s_ --s_ w w w -- -_n.. -- _- 9.72 ---14.04-, 3.72 14.04 10.14 ._3� ___14.04 3.72 14.04 _ 16.38 - - 237 _ _ 10.1.4 0.83 _ -- 30.68. -233 __ 13.57 2.33 34.61 10.72 _ --- 13.57 2.33 34.61 36.89 1.15 '_ _ .10.72 1.63 . _ .:0.00 - - 96 -.___0 135 16 0 91 .. -_ 0 0 0 0 -� -0 _ _____0 171 _ - 171 ___ -96 -0 119 0 0 -- -. - 351- _-0 441 229 0 ----- 223 _0 276 566 0 ------ 0 0 - 0 ,_ 0 28 0 20 - - - 0 0, - -- - 0 0 48 0 20 103 0 204 65 0 216 91 _ 0 0 0 . _ -,-- 0 -- 0 ,-0 171 _ _ 340 0 " 213 0 _ 0 0 0 0 0 0_ _ � 0 -_-0 0 0 --_-- U ' 0 0 0 0 .- - - 0 0 _-.._-0 278 0 0 _ - 0 87 16 0 0 - - - 0 71 __--.-16 99 0 0 _- - 0 168' _ 162 82 0 0 _--- - _ 0 Clq - 172 162 142 99 37 _ _i135 0 _ --99 `6 169.. 0; 6 c) AED exarsion 91 -28 Ernelopeloss(gain 2643 1647 888 667 12 a) Infiltration b) Room ventilation 686 0 216 0 102 0 32 0 13 Intemalgains: Occupants@ 230 AFpliancesbther 1 230 0 0 0 0 Subtotal (lines 6to 13) 3329 2093 990 699 14 15 Less extemalload Lesstransfer Redistribution Subtotal buc t loads 9'/0 M%j 0 0 180 3509 325 0 0 127 MM 444 91/6 2O1. 0 0 -990 0 0 0 0 -699 0 0 Total room load ,Air required (cfm) 3834 0 2664 121 0 0 0 0 Calculations approved byACCAto meet all requirements of Manual J 0 Ed. t Ard.- wrightsofem 2018-Aug-1511:10:54 RigFt-Sdte®Uriversal 2018 18.0.19 RSU16877 Page 7 \Desldop\TEMP PRINT\Lot 004 F1452 B LHG - E.r p Calc= W8 Frort Door faces: E wrightsoft® Duct System Summary Entire House One Stop Cooling and Hating 7225 Sardscove Cout, Wirter Park, FL 32792 Phore: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCooling.00m Licerse: CAC032444 For: Ryan Homes Jab: Lot 004 F1452 B LHG - E Date: 10/19/2015 By- RULF Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.16 in H2O 0.16 in H2O Available static pressure 0.34 in H2O 0.34 in H2O Supply,/return available pressure 0.170/0.170 in H2O 0.170/0.170 in H2O Lowest friction rate 0.253 in/100ft 0.253 in/100ft Actual airflow 0 elm 773 cffn Total effective length (TEL) 134 ft Name Design (Btuh) Htg Mal) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk i BED2 c 2664 0 121 0.269 8.0 Ox0 VIFx 21.5 105.0 st2 BEDS c 1316 0 60 0.310 6.0 Ox0 VIFx 14.7 95.0 st2 BTH2 c 530 0 24 0.298 4.0 Ox 0 VIFx 14.1 100.0 st2 DIN c 2922 0 133 0.274 7.0 Ox 0 VIFx 29.1 95.0 st-I GREA I c 1653 0 75 0.299 6.0 Ox 0 VI Fx 18.7 95.0 sti GREAT -A c 1653 0 75 0.306 6.0 Ox0 VIFx 16.3 95.0 sti Krr c 1901 0 86 0.271 6.0 Ox0 VIFx 25.5 100.0 st1 WED c 2945 0 134 0.276 7.0 Ox0 VIFx 23.3 100.0 st1 IVIBTH c 651 0 30 0.271 5.0 Ox0 VIFx 25.7 100.0 st1 NMIIC c 640 0 29 0.253 4.0 Ox0 VIFx 24.3 110.0 st1 PAN c 152 0 7 0.272 4.0 Ox0 VIFx 25.0 100.0 s12 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st1 PeakAVF 0 561 0.253 715 12.0 0 x 0 VinIFIX st2 PeakAVF 0 212 0.269 479 9.0 0 x 0 VinIFIX wrightsoft- 201 B-Aug-1511:1055 .M.,.• m,�,�wti.rym-w� RigFt-Sute®Uriversal201818.0.19RSU16877 Page 1 ACCKI ...\Desldop\TEMP PRINT\Lot 004 F1452 B LHG - E.r p Calc= W8 Frort Door faces: E NameGrille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR veloc (ipm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat Trunk rbi Ox 0 0 773 0 0 0 0 Ox 0 VIFx 1:1055 2018-Aug-151 ACK-F:- wrightsoft°° Page 2 Rigli-S ute®Uriversal201818.0.19RSU16877 �Desldop\TEMP PRINT\Lot004 F1452 B LHG - E.np Calc= W8 Frort Door faces: E I i - wrightsoft® Static Pressure and Friction Rate Entire House One Stop Cooling and Heating 7225 Sani stove Cowl, W irter Park FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OrBStopCooling.com Licerse: CAC032444 For: Ryan Homes Job: Lot 004 F1452 B LHG - E Date: 10/19/2015 By: RI/LF Heating (in H2O) Cooling (in H2O) External static pressure 0.50 0.50 Pressure losses coil 0 0 Heatexchanger 0 0 Supply diffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.34 0.34 (tt) (it) Measured length of run -out 12 0 Measured length of trunk 12 0 Equivalent length of fittings 110 0 Total, length 134 0 Total) effective length 134 FrictiQn Heating Cooling (in/1001t) (in/100ft) Supply Ducts 0.253 > 0.18 0.253 > 0.18 Return Ducts 0.253 > 0.18 0.253 > 0.18 I Fitting Equivalent LengthDetails supply 4X--35,11 A=20,11 G=5,11 G=5,11 G=5,1 A=35,11 Gam: Total EL=110 Retum TotalEL=0 wrightsoft- 2018-Aug-1511:1055 .M,..•,�, ,�w,w-,�-w•, Rigk-Sdte®Uriversa1201818.0.19RSU16877 Pagel ACCK...\Desldop\TEMP PRINTIot 004 F1452 B LHG - E.r p Calc= W8 Frort Door faces: E Job #: F1452 B LHG Performed by RI/LF for: Ryan Homes Level 1 One Stop Cooling and Heating 7225 Sandscove Court Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 www.OneStopCooriing.com OrrA4 Scale:1 : 79 Page 1 Fight -Suite® Universal 2018 18.0.11 RSU23249 201 &Apr-13 10:16:27