FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regu - Re idential Performance Method
Project i Name: Lot 067 F1833 A RHG Den - N
Builder Name: Ryan omes
Street:
Permit Office: St. Lucie
SCANNED
City, State, Zip: Ft. Pierce , FL , 34951
Permit Number:
pay E�
Owner:
Design Location: FL, Fort Pierce
Jurisdiction: 661000 7/
County`. St. Lucie (Florida Climate Zone 20 Lucie County
1. New construction or existing New (From Plans)
9. Wall Types (171.6.0 sqft.)
Insulation Area,
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1369.30.ft2
i
b. Frame - Wood, Adjacent
R=11.0 346.67 W
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
1
10. Ceiling Types (1833.0 sgft.)
Insulation Area
5. Is this 1 worst case? No
a. Under Attic (Vented)
R=30.0 1833.00 ft2
6. Conditioned floor area above grade (ft2) 1833
b. N/A
R= ft2
cDuc
R_ f2
Conditioned floor area below grade (ft?) 0
11 s
R ft2
7. Windows(171.6 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 366.6
a. U-Factor: Dbl, U=0.54 118.22 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl, U=0.63 53.33 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.32
a. Central Unit
28.0 SEER:14.00
c. U-Factor: N/A ft2
SHGC:
13. Heating,systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
27.8 'HSPF:8.20
SHGC: ,
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weigbted Average SHGC: 0.313
14. Hot water systems
a. Electric
Cap: 50 gallons
B. Floor Types (1833.0 sqft;) Insulation Area
EF: 0.900
a. Slab -On -Grade Edge Insulation 14=0.0 1833.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/F,loor Area: 0.094 Total Proposed Modified Loads: 57.48
PASS
Total Baseline Loads: 58.44
I
I hereby certify that the plans and specifications covered by
Review of the plans and
��1HES?,4?
this calculation are in compliance with the Florida Energy
specifications covered by this
Code. Bo an Digitallysignedby6ojan'
Paukovic
calculation.indicates compliance
,;:Date: 2018.10.0810.42:36
Paukovic
with the Florida Energy Code.
Before is
r
PREPARED BY:
construction completed
DATE:
this building will be inspected for
compliance with Section 553.908
I herebylcertify that this building, as designed, is in compliance
the Florida Energy Code.
Florida Statutes.
with
OWNER/A E I I
BUILDING OFFICIAL:
DATE:
DATE:
I
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in
accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house.
10/8/2018 10:40 AM EnergyGauge® USA Section R405.4.1 Compliant Soft are Page 1 , f 4
F:nRM R40S-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 067 F1833 A RHG Den - Bedrooms: 3
User Conditioned Area: 1833
Total Stories: 1
1 Worst Case: No
Ryan Homes Rotate Angle: 270
St. Lucie Cross Ventilation: No
661000 Whole House Fan: No
Single-family '
New (From Plans)
Address Type: Street Address
Lot # 67
Block/Subdivision: Oakland Lake
PlatBook:
Street:
County: St. Lucie
City, State, Zip: Ft. Pierce ,
FL, 34951
CLIMATE
v Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299 62
Low
BLOCKS
Number
Name
Area Volume
1
Blocki
1833 15947.1
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
Main
1833 15947.1 Yes 4
3
1 Yes Yes
Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio Main 158 ft 0
1833 ft2
---- 0.29 0
0.71
ROOF
V/ #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt Emitt Deck
Tested Tested Insul.
Pitch
(deg)
1
Gable or Shed Composition shingles 1985 ft2 382 ft2 Dark
0.6
N 0.6 No 0
22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300 1833 ft2
N N
I
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1833 ft2 0.1 Wood
10/8/2 I18 10:40 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 2 of 4
r:nann Renr,-,;)ni7 INPI IT RI IMMARY CHFICKLIST REPORT
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar
Below
9
Space
nrnt In Wall Type
1
jN=>W Exterior Concrete Block - Int Insul Main
4.1 28 6 8
8 247.0 ft2
0
0 0.6
0
2
I E=>N Exterior Concrete Block - Int Insul Main
4.1 30 6 8
8 264.3 ft2
0
0 0..6
0
- 3
S=>E Exterior Concrete Block - Int Insul Main
4.1 48 6 B
8 420.3 ft2
0
0 0.6
0
4
,
W=>S Exterior Concrete Block - Int Insul Main
4.1 50 6 8
8 437.7 ft2
0
0 0.6
0
.5
-=>SW Garage Frame - Wood Main
11 40 0 8
8 346.7 ft2
0
0.25 0.6
0
DOORS
# Ornt Door Type Space
Storms
U-Value
eightln
Area
Ft
In
In
Ft
1 E=>N Insulated Main
None
.4 3
6 8
20 ft2
2 -=>SW Wood Main
None
.46 2
B
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 270 degrees).
/
Wall
Overhang
V/
# Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area Depth
Separation
Int Shade
Screening
11
N=>W 1 Metal Low-E Double Yes
0.54 0.31 N
16.4 ft2 1 ft 0 in
2 ft 0 in
Drapes/blinds
None
2 E=>N 2 Metal Low-E Double Yes
0.54 0.31 N
49.3 ft2 1 ft 0 in
2 ft 0 in
Drapes/blinds
None
3 S=>E 3 Metal Low-E Double Yes
0.54 0.31 N
3.1 ft2 1 ft 0 in
2 ft 0 in
Drapes/blinds
None
4 W=>S 4 Metal Low-E Double Yes
0.54 0.31 N
49.3 ft2 1 ft 0 in
2 ft 0 in
Drapes/blinds
None
5 W=>S 4 Metal Low-E Double Yes
0.63 0.32 N
53.3 ft2 1 ft 0 in
2 ft 0 in
Drapes/blinds
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 411 ft2 411 ft2
64 ft
8.7 ft
1
INFILTRATION
# Scope Method SLA
CFM 50 ELA EgLA ACH
ACH.50
1 Whoiehouse Proposed ACH(50) .000276
1328.9 72.96 137.2 .2054
5
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
I
1 Electric Heat Pump/ Split
HSPF:8.2
27.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type Subtype
Efficiency
Capacity_ Air Flow
SHR Block
Ducts
I
1 Central Unit/ Split
SEER: 14
28 kBtu/hr B40 cfm
0.75 1
sys#1
10/8/2018 10:40 AM EnergyGauge(D USA Section R405.4.1 Compliant Software Page 3 of 4
FnRnn R4ns-Pn 17 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.9 50 gal
60 gal
120 deg
None
i
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
---- Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
V
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 366.6 ft
Main
91.65 ft Proposed Qn
Main
--- cfm
91.7 of 0.05
0.50
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolingj Jan [ Feb
Heatin[, ] Jan LX} Feb
[ ] Mar
[X] Mar
j
[_
] Apr
] Apr
May Jun [X� Jul
May Jun ] Jul
jXj AugSe
] Au
Sep
r
[ ]
Oct
Oct
Nov
HX Nov
Dec
H Dec
Ventin � [[x�] Jan l 1] Feb
[[[XXX]]J Mar
[[XX]]
A r
L Ma l Jun ]Jul
L l E
E ] Au
l Se
l
[[[XXX]]]
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule�Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 76 7B
78
78
78
7B
78
78
Heating (WD) AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
66
68
68
68 68 BB
6B
68
66
68
66
66
Heating (WEH) AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
6B
68
68
6B 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ftz
0 ft
0.3
Main
Name: Test Rater
Rating Compant: Test Rater
I
10/8/2018 10:40 AM
Signature:
Date:
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 4 of 4
Florida Building Code, Energy Conservation, 6th Edition (2017)
ndatory Reauirements for Residential Performance, Prescriptive and ERI Methods
S: Permit Number:
Ft. Pierce , FL , 34951
MANDATORY REQUIREMENTS See individual code sections for full details.
SECTION R401 GENERAL
Fj R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and;specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD.
i
R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
(Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
EJ R402.4.1 Building thermal envelo'ilee building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.
The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
EJ with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction: Where required
by the code official, an approved third party shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through B. Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (1) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended
infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
B. Supply and return registers, if installed at the time of the test, shall be fully open.
R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where
using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907.
I
R402.4.3 Fenestration air Ieakage.Windows,•skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or
AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
10/8/2018 10:4.0 AM EnergyGauge@ USA - FBC 6th Edition (2017) Compliant Software Page 1 of 5
MANDATORY REQUIREMENTS - (Continued)
❑R402.41.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passesl through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
betweeh conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more tHan 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
R403.1 controls. SECTION R403 SYSTEMS
❑ R4 i3.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
,that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
j for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in
accordance with Section R403.3.3.
❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2.percent
of the design airflow rate when tested in accordance with ASHRAE 193.
❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the
manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test.
2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the
entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the
test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.
A written report of the results of ihe.test shall be signed by the party conducting the test and provided to the code official.
❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C)
or beloInv 55°F (13°C) shall be insulated to a minimum of R-3.
I
R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
❑ R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in
accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
13403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return
❑ pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
10/3/2018 10:40 AM EnergyGauge@ USA - FBC 6th Edition (2017) Compliant Software Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat, traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 1/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies (Mandatory)-
R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature
setting range shall be from 100°F to 140OF (38°C to 600C).
R403:5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of
combustion types of service water -heating systems to be turned off.
Fi R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
EJ R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
❑■
n
0
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation
including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that
;close when the ventilation system is not operating.
! R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be
powered by an electronically commutated motor.
R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise.
R403.7 Heating and cooling equipment (Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that
affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed.
TABLE R403.6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
(CFM)
MINIMUM EFFICACY a
(CFM/WATT)
AIRFLOW RATE MAXIMUIV
(CFM)
Range hoods
Any
2.8 cfm/watt
Any
In -line fan
Any
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
<90
Bathroom, utility room
90
2.8 cfm/watt
Any
for SI: 1 cfm = 28.3 Umin.
!
10/8/2018 10:40 AM
When tested in accordance with HVI Standard 916
EnergyGauge@ USA - FBC 6th Edition (2017) Compliant Software Page 3 of 5
MANDi TORY REQUIREMENTS - (Continued)
❑R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
thari the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.7, or the closest available size provided by the manufacturers product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
Theipublished value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's
expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of
iequipment may be sized in accordance with good design practice.
R40II3.7.1.2 Heating equipment capacity.
❑ IR403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
❑ IR403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
ElC403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
❑ R463.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50oF (10°C), and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40OF (4.80C).
❑ R4031.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots.
❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at
❑ the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
❑ efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
10/8/2018 10:40 AM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 4 of 5
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
R403.i11 Portable spas (Mandator9be energy consumption of electric -powered portable spas shall be controlled by the
requirements of APSP-14.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
❑ .R404.� Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be
high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps.
Exception: Low -voltage lighting.
R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
10/8/2018 10:40 AM . EnergyGaugeO USA - FBC 6th Edition (2017) Compliant Software Page 5 of 5
i
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1: New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2 Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
I
No.
3.
1
c) AHU location Attic/Main
31 of units (if multiple -family)
4' Number of bedrooms
4.
3
13. Cooling system: Capacity
28.0
a) Split system SEER
14.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1833
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor: (weighted average)
7a.
0.568
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.313
14. Heating system: Capacity
27.8
c) Area
7c.
171.6
a) Split system heat pump HSPF
8.2
b) Single package heat pump HSPF
8; Skylights
c) Electric resistance COP
a) U-factor: (weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
I a) Slab -on -grade (R-value)
9a.
0.0
I b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.90
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
1OA1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
"Label required.by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I icertify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this.home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
I
Builder Signature: Date:
Address of New Home
I
I
10/8/20118 10:40:50 AM
5 3 a l 00K la ►1.. Lcak 0 r. City/FL Zip: Ft. Pierce, FL 34951
EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Lot 067 F1833 A RHG Den - N Builder Name: Ryan Homes
Street: Permit Office: St. Lucie
City State, Zip: Ft. Pierce , FL, 34951 Permit Number:
Owner: Jurisdiction: 661000
W
Design Location: FL, Fort Pierce
0
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling%attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with. the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors)
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)'
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped..
shall be permanently attached to the crawlspace
Shafts; penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
I
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voidsI between fire snrinkler cover plates and walls or cellin
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
10/13/2018 10:41 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
- - wrightsoft® Project Summary
Entire House
One Stop Cooling and Heating
7225 Sandscove Colrt, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwKOneStopCoolirg.com License: CAC032444
For:
Ryan Homes
Job: Lot 067 F1833 A RHG Den
Date: 06/07/2017
By: XF/MC
Weather: Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42
OF
Outside db
90
OF
Inside db 68
OF
Inside db
72
OF
Design TD 26
OF
Design TD
18
OF
Daily range
M
Relative humidity
50
%
Moisture difference
68
gr/Ib
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 17275
Btuh
Structure
16190
Btuh
Ducts 1765
Btuh
Ducts
3491
Btuh
Central vent (0 cfm) 0
Btuh
Central vent (0 cfm)
0
Btuh
(none)
(none)
Humidification 0
Btuh
Blower
0
Btuh
Piping 0
Btuh
Equipment load 19039
Btuh
Use manufacturer's data
n
Rate/swin multipplier
0.95
Infiltration
Equipmenilsensible load
18697
Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
3279
Btuh
Ducts
897
Btuh
Central vent (0 cfm)
0
Btuh
Heating
Area (ft2) 1853
Cooling
1853
(none)
Equipment latent load
4176
BtuFi
1
V me623
1
Air chan(gftes/hour 0.38
0120
Equipment Total Load (Sen+Lat)
22873
Btuh
Equiv. AVF (cfm) 102
54
Req. total capacity at 0.75 SHR
2.1
ton
Heating Equipment Summary
Cooling Equipment Summary
(Make Goodman Mfgg.
Make Goodman Mfgg.
Trade GOODMAN; JANITROL;AMANA
DISTI...
Trade GOODMAN; JANITROL;
AMANA DISTI...
'Model GSZ140301 K
Cond GSZ140301 K
AHRI ref 7995113
Coil ARUF31 B14A
AHRI ref 7995113
Efficiency 8.2
HSPF
Efficiency 12.0 EER,14
SEER
Heating input
Sensible cooling
21000
Btuh
Heating output 27800
Btuh @ 470F
Latent cooling
7000
Btuh
(Temperature rise 0
OF
Total cooling
28000
Btuh
Actual air flow 0
cfm
Actual air flow
933
cfm
Air flow factor 0
cfm/Btuh
Air flow factor
0.047
cfm/Btuh
,Static pressure 0.50
in H2O
Static pressure
0.50
in H2O
'Space thermostat
Load sensible heat ratio
0.82
Capacity balance point = 33 OF
I
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wrightsoit® 2018-Oct-0810:3620
Right-Stnte®Universal 2018 18.0.31 RSU16877 Page 1
ACCK ktop\TEMPPRIN-RLot067F1833ARHGDen- N.rup Calc=W8 Hoisefaces:N
-1 I- wrightsoft' Right-M Worksheet
Entire House
One Stop Cooling and Heating
7225 Sandscwve Court, W irder Park, FL 32792 Ptnre: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopCooling,com License: CAC032444
Job: Lot 067 F1833 A RHG Den - N
Date: 06/07/2017
By: XF/MC
1
Room name
Entire House
NEED
2
3
Ei posed wall
Room height
158.0 it
8.7 ft d
30.5 It
8.7 ft heaVmol
4
Room dimensions
13.5 x 17D ft
5
Room area
1853.3 ft2
229.5 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(Bluh4f-q
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
U�J
i G
13A-flocs
:------_-----....__0540._.n.--•---.1404:,
-0.143
n
3 72
2 62
1331,
` 248
__ 16,
' - 232
__._0_..-_
661
_229-_.___218
606
0
_0
0
--._0_.M
0
.'0..
0
-0-
VI
I
......
13AAocs
0.143
a
3.72
2.62
265
196
730
514
0
0
0
0
11
I D
V jJ
4A5 tom
11DO
13A-4ocs.
0.540
- 0.390
0.143
a
a
s
14.04
10.14
3 72
28.62
11.50
2:82
49
20
422
0
- 20
- 419
688
J 204
1558
.1403
__�1
1096
0
_ __-0
' 148
0
_. __....0
148
0
0
- 550.
0
_---_ ... 0
387
r
,4A5.2om. _ ._.
13A-4ocs
__ 0.540
0.143
._ s _.
w
_ _.14. 4:.-.__13:31...._
3.72
2.62
._... 3
439
_.. _._.,._.3
337
. :_._......___
1252
.._40
881
..-._...__ A
117
_. _.... . 0
85
_.. _ - 0
315
- -
222
�-12C
D
C
F
I
4A5-2om
4A52omd
0sw
--11D0.--.._
16B-30ad - _
22A m
� .., _ _ ., .
_._..
-..__--------- - -=-.
0.540
0540
0 091
_.0.390
OA32
_...._.. 1.180
_..
-----__---...-__._.
w
w_
--n.....
_ . _..
- --
14.04
1404
2 37
10'14..-.__11
0.83
30.68•
-- - -
..
28.62
3278
1 33
50
1.70
_ _ -- 0;00
- r
49
54
348
; ._...._ 18
1853
...- _ _1853
_
...._:. -
0
0
330
_- --_.18
1853
.. - _ _:158
- - ---•-
688
753
781
:.:_. _IBl_
1542
. , _ 4847
------
1403
1757
439
........ 3143
_ .. :_ , 0
_..
___.. --
33
0
- 0
230
._ .. 230
-
-
- ----
0
0
0
230
. ' . .- 31.
... ....
---= -
459
0
0
191
-- ....
- - - 936
---......
-`-- -
---- --
936
0
,•_ _ _. _ .. -..0
389
... _...._
.:. 0
_._...._
- -
-
6
c)AED.1.1on
570
252
Envelope loss/gain
14357
12507
2451
2186
12
a) Infiltration
2918
1063
563
205
b) Room ventilation
0
01
0
0
13
Internal gains: Oocupants @ 230
4
920
2
460
I Appliances/other
1700
0
Subtotal(lines 6to13)
17275
16190
3014
2851
Less external load
0
0
0
0
Lesstransfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
17275
16190
3014
2851
15
Duct loads
1 10%1
229/6
1765
3491
10%1
229/6
308
615
Total room load
19039
19681
3322
3466
Air required (cfm)
0
933
0
164
Right-8uite®Urrversal201818.0.31 RSU16877
ktop\TEMP PRINRLot067F1833ARHGDen-N.rup Calc=MJ8 Housefaces:N
2018-Oct-0810:36:30
Page 1
- l- wRghtsoft° Right-JO Worksheet
Entire House
One Stop Cooling and Heating
7225Sard.. Court, Winter Park, FL32792Phone: (407)629-6920 Fax: (407) 629 - 9307 Web: wwwOreStopCooling.comLicenz:CAC032444
Job: Lot 067 F1833 A RHG Den - N
Date: 06/07/2017
By. XF/MC
1
Room name
METH
MWIC
2
3
4
5
Exposed wall
Room height
Room dimensions
Room area
15.0 ft
8.7 It heaUmol
1.0 x 107.5 It
107.5 H2
0 ft
8.7 ft heaUcool
7.0 x 11.0 ft
77.0 m
Ty
Construction
U-value
Or
HTM
Area (fl2)
Load
Area (ft2)
Load
number
(Bfuh4I!-°F)
(Btuw)
or perimeter (8)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
y/ i
G
-
13A-4ois . __ . —
.4A5-2om.... _ . __:
13A-4o s
0:143
.--- -;0.540
0.143
- n ..
._. n _
a
_
3 72
. . _1404.
3.72
2 62
_. _13 31
2.62
` __
- 0
0
_ _ 0
- - - 0
0
0
--- _0
0
O
---- 0
0
,.--- _ 0
-
-_ 0
0
-- O
___. _ _:0
0
_, p...0
_ _ _ "0
0
.. _ -0
0
11
III��� D
yy!! .
4A5-2om
11D0
• - � - -- •�-
13A flocs -
0.540
_ 0.390
0.143
a
a
s
14.04
10.14
372
28.62
1 150
262'
0
0
131
0
0
127
0
_.- 0
474
0
0
_ _... _. _ .
334
0
0
_... - .
0
0
0
_ . _.... _ .
-0
0
0
._ .- _.. .
0
0
0
0
4A572om __._. _. _
13A-4ocs
_ 0.540
0.143
_. s
w
-_..14.04
3.72
.- __ 1331,
2.62
, . _ .-.. 3
0
..._-3
0
_ . _._._
0
. __-..-_ 40
0
,._- -- --__.0
0
_ _- --_ . 0
0
-•_. _- .-�
0
-- _ -- - -A.
0
4A5-2om'
4A5-2omd
12C Osw ._
0.540
0540
0:091
w
w
14.04
1404
23Z
28.62
3278
. 1 33
D
0
.... . .0
0-
0
0
0
0
0
0
0
0
0
0
_ 0
0
0
0
0
0
0
0
0
0
D._11D0
C
_
16B 30ad
-0.390,-_n..._.
J014.----.11:50
083
1.70
__ 0_
108
_,.......0-
108
0
89
._._0
182
.__._ _-_0.:-_
77
..__.,. 0__.
77
64
131
_ .
:22A . m_..
7.1
__.. _._0.032
.,..=.'1.180
-
__.30 68
0:00
_ .. _.106
...._ ..:.-15
_ . 460
'° - - 0
.:.... _ ..77
_ _ . --
; 0
- .._....-_._.._._.
_ .. - -0
_.._,
0
6
c) AED excursion
-42
1-8
Envelope loss/gain
11066
5141
64
122
12
a) Infiltration
277
101
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
1343
615
64,
122
Less external load
0
0
0
0
Lesstransfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
1343
615
64
122
15
Ductloads
10%
22%
137
133
10%
22%
7
26
Total room load
1480
748
71
149
Air required (cfm)
I0
35
0
7
-*- wrigtitsofl�
Right -Suite® Universal 2018 18.0.31 RSU16877
ktop\TEMPPRINi\Lot067F1833ARHGDen- N.np Calc=WB Housefaces: N
2018-Oct-0810:36:30
Page 2
-f wrightsofta Right-JO Worksheet
Entire House
One Stop Cooling and Heating..
7225SandscoveCoot, Winter Park, FL32792Phone: (407)629-6920 Fax:(407)629-9307 Web: wvw.OreStopGoolirg.comLicense: CAC032444
Job: Lot 067 F1833 A RHG Den - N
Date: 06/07/2017
.By: XF/MC
1
Room name
DEN
FOY
2
3
4
5
EiPoseclVdI
Room height
Room dimensions
Room area
30.0 ft
8.7 ft heat/cool
13.5 x 13.0 ft
175.5 fF
5.5 ft
8.7 ft heaUcool
5.5 x 9.5 ft
52.3 fl!2 .
Ty
Construction
U-value
Or
HTM
Area (ft)
Load
Area (ft)
Load
number
(Btuhlt--F)
(Btuh/fF)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
vIJ !
G
13A-4ois-----
-05-2om._......__ _..._ . _
0.143
.._- ..0 540
n
_. n.
3.72
_ .14.04
262
_ ,_ 13 31:
•-- - `'3D
_ __0
�---- 30
_ _, 0
--�--'�113
-_ _ 0
"�- 80
__ __ . 0
� �-� --0
-. ,
--- - 0
0
--�--- 0
--�--0
13A-4ocs
0.143
a
3.72
2.62
117
101
376
265
48
28
103
73
11
I D
UIJ
G
4A5-2om
11D0---.. _... _.__._._
13A-4ocs
;9A5 tom-.-_.._.:.
13A-4ocs
0.540
._.._ . 0.390
0.143
0.540
0.143
a
a
s
_ s._:
w
14.04
10.14
3.72
_ .. 14.04
3.72
28.62
11.50
2B2
_ . 13.31.
2.62
16
. .__D
113
_ _ . -- _ 0
0
0
. _ 0
113
.. .._ - _ _ 0
0
229
0
421
_ _ ... ._ 0
0
468
0
296
_._ .,._ . -.:0
0
0
20
0
- 0
0
0
20
0
_.. _.., -0
0
0
_ 204
0
- -. 0:
0
0
- - 231
0
- - 0
0
__.-
D
C
4A5-2om
4A5 2omd
12C Osw
;11D0._..
16B-30ad
0.540
0.540
6A91
.0390
0.032
w
w
14.04
14.04
237
0.83
28.62
32.78
1.33
50
1.70
0
0
D
-0-
176
0
0
0
0_.._-._.__.0,_.._...._
176
0
0
0
146
0
0
0
0....__-_._.0_
298
0
0
0
52
0
0
0
-_.0
52
0
0
0
__0
43
0
0
0
89
F.
22A.G1m .: . ;
1,180
r. _
30.68.._
: .0.00
' _ . 176
`.. 3p
- . 920
. ,_ _... 0
- .... 52
_ .
.. _ _ .. 6
.. .. - 1.6
_ _.
... - 0
61
c) AED excursion
-11
-27
Envelope loss/gain
2205
1395
519
365
12
a) Infiltration
554
202
102
37
b) Room ventilation
0
0
0
0
13
Internal gain.: Occupants@ 230
0
0
0
0
Applianoesrother
0
0
Subtotal (lines 6 to 13)
2760
15971
621.
402
Less external load
Less transfer
0
0
0
0
0
0
0
0
Redistribution
241
156
-621
-402
14
Subtotal
300D
1753
0
0
15
Duct loads
1 10%1
229/6
306
378
10 %
22%
0
0
i
Total room load
3307
2131
0
0
Air required (cfm)
0
101
0
0
Calculations approved byACCAto meet all requirements of
'wrYghtisoTt' 2018-00-0810:36:30
Right -Suite® Universal 201818.0.31 RSU16877 Page 3
ktop\TEMP PRINT\Lot067F1833ARHGDen- N.rup Calc=MJ8 Housefaoes:N
-�- wirightsoft- Right-JO Worksheet
Entire House
One Stop Cooling and Heating
7225 Sardscove Cart, Wirder Park, FL 32792 Phore: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wowuOneStopCooling.com License: CAC032444
Job: Lot 067 F1833 A RHG Den - N
Date: 06/07/2017
By: XF/MC
1
Room name
DIN
Krr
2
3
E�posedwall
Room height
15.0 ft
8.7 ft heat/000l
0 ft
8.7 ft heat/cool
4
5
Room dimensions
Room area
11.5 x 13.0 ft
149.5 flz
1.0 x 324.0 It
324.0 IF
Ty
Construction
number
U-value
(Btuh4l! °oq
Or.
HTM
(Btuh4tz)
Area M)
or perimeter (ft)
Load
(Btuh)
Area
or perimeter (ft)
Load
(Btih)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
1
6
y/
-G
13A-flocs
.4A5-2om..:_ .., __
- 0.143
._:_._ 0.540
0.143
n
_.n-
e
3.72
_ 14.04
3.72
2.62
_.. .13:31
2.62
i0
.. _.
100
: 0
-0
67
D
_-- __. 0
250
0
_-_.00
176
0
- _-_ 0._
0
0
-_ 0
0
0
----0,
0
0
_ __. - 0"
0
11
L13A-4ocs
ID
y!
TL G
4A5-2om
11 D0 __.. _ _
1 M 4ocs
,4A5-2om - _
13A-4ors
0540
. _ _ - 0.390
0.143
0.540
0.143
a
e_
" s
_.s ._
w
14.04
10.14
.3.72
.__ 14.04
3.72
28.62
- 11.50
2.62
_-13.31
2.620
33
0
3D
0
0
.... _ . . _0
30
_. -. _ .. 0
0
459
_.. 0
113
,.------- --- 0
0
936
.._.-...... 0
80
- - - .0
0
0
_ ... _ .. _0
0
..._._ . 0
0
0
..--.- - --�
0
.......... __--0
0
0
_.....- 0
0
- - - :0
0
0
0
0
- -D
0
R
_ D
C
4A5-2om
4A5-2cmd
12b Osw
11D0_ _
16B 30ad
0.540
0.540
0.091
.-.0.390
w
w
-n-
14.04
14.04
2.3Z
_ _ 10.14.
0.83
28.62
32.78
1,33
_ _ 11,50
1.70
D
D
113
-_._ _ _ 0
0
0
113
----- _._0
0
_ 0
268
__ ---0
124
0
. 0
150
_.__._ ._0
254
0
.._- • -- _.0
61
�_ ----.0
0
.. _ ._. 0
61
.-- ..- -_ -0
324
0
. ._ 0
1'44
..- __. _ 0
0
0
-" Bi
550
:F. i,.22A-cpm-
.. -. _
--
_0.032
_. 1.180
- __.._......
-
_ _ _.
_30.68
-
- --- -0.00
_.. _._150
_. ;. __.15D
_.. ......
_._..-150
.. _ _..__16
......
_...._.
. _._463
_
.-_ _ _. --.--,0
..- -- -324
_ _
_..
._ - --'270
...
- -•._
-_..0
6
c) AED excursion
76
-117
Envelope loss/gain
1675
1671
414
514
12
a) Infiltration
277
101
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
. Appliances/other
0
1200
Subtotal (lines 6 to 13)
1952
1772
414
1714
Less external load
0
0
0
0
Lesstransfer
0
0
0
0
Redistribution
241
156
142
96
14
Subtotal
2192
1928
556
1809
15
Ductloads
10%
22%
224
416
10%
220/,
57
390
Total room load
F7
2416
2344
613
2200
Air required (dm)
0
111
0
104
to meet all requirements of Manual J 8th Ed.
-r}F wrigtitsoTt�
Rigk-Suite® Universal 2018 18.0.31 RSU76877
ktop\TEMP PRINT\Lot067 F1833A RHG Den- N.np Calc= MJ8 House faces: N
2018-Oct-08 10:36:30
Page 4
-ll- wrightsoft° Right-JO Worksheet
Entire House
One Stop Cooling and Heating
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: v w 0reStopCooling.wrn License: CAC032444
Job: Lot 067 F1833 A RHG Den - N
Date: 06/07/2017
By: XF/MC
1
Room name
GRT
BTHi
2
FoosedMail
17.0 it
6.0 ft
3
Room height
8.7 H heaV000l
8.7 ft heaUmol
4
5
Room dimensions
Room area
17.0 x 14.0 It
238.0 ft2
1.0 x 79.5 ft
79.5 W
Ty
Construction
U-value
Or
HTM
Area (T)
Load
Area 09
Load
number
(Btuh4I!--0
(Btuhr)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
1�1
`13A 4oc5 `_
0.143
n
372"
04,._
2'62
1331:
j— _0
__.._.0_---.
0
_-0..:
. _ _; _. 0
_"_-_ 0
_. 0
.... _..0_—..
0
------ 0:____._0__._.'_—_
0'
0
o
0
-_--0
13A-4ocs
0.143
a
3.72
2.62
0
0
0
0
0
0
0
0
11
y/
4A5-2om
11 DO
13A-4ons
13A-4ocs
0.540
0.390
0.143
0.143
a
a
' s
w
14.04
10.14
3:72
3.72
28.62
11.50
2:62
2.62
0
0
0
148
0
0
0
94
0
0
0
351
0
0
0-
247
0
0
0
52
0
0
0
__0
52
0
0
'� 0—
194
0
0
0
137
Ti (r
4A5-2om
4A5-2omd
Osw ,-_l.... .. __ _
0.540
0.540
0.091
w
w
14.04
14.04
2 37
28.62
32.78
;1.33
0
54
0
0
0
; 0
0
753
0
0
1757
' 0
0
0
0
0
_ — 0
0
0
0
' 0
0
0
6
�12C
D-
C '•
1613-30ad
0.032
0.83
1.70
238
238
198
0...__.
404
:-__0_._
80
.-._0_
80
_ 0'
66
A.
135
17
__._.:. 522
_ _. _ 0
-
_ ------ 80
6
_. _ -1 A
.61
c)i AED exarsion
503
-20
Envelope loss/gain
1823
2911
444
252
12
a) Infiltration
314
114
111
40
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
2137
3025
555
292
Less external load
Less transfer
Redistribution
0
0
3
0
0
6
0
0
9
0
0
17
14
Subtotal
2140
3031
564
309
15
Ductloads
100/6
22%
219
654
10/
22%
58
67
Toital room load
2358
3684
622
375
Air required (cfm)
0
175
0
18
Calculations approved byACCAto meet
ii+- Vwrigt•rrtsCbVt-
Right-Suite®Universal 201818.0.31 RSU16877
...ktop\TEMP PRINRLot067 F1833A RHG Den- N.rup Calc= MJ8 House faces: N
2018-Oct-08 10:36:30
Page 5
wkghtsoft, Right-M Worksheet
Entire House
One Stop Cooling and Heating-
7225 Sardscove Cart, Winter Park, FL 32792 Ptnre: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCooling.00m Licerre: CAC032444
Job: Lot 067 F1833 A RHG Den - N
Date: 06/07/2017
By: XF/MC
1
Room name
BED2
AC
2
Dosed wall
26.0 ft
0 ft
3
Room height
8.7. it heat/cool
8.7 ft heaV000l
4
Room dimensions
1.0 x 160.5 It
5.5 x 3.5 ft
5
Room area
160.5 ft2
19.3 ft2
Ty
Construclion
U-value
Or
HTM
Area OF)
Load
Area OF)
Load
number
(Btuh4t?--g
(Btuh/W)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
I G
13A 4ocs.- - -
0143
rS
3 72
2 62
104
104
388
273
- 0
, 0
'- 0
- - - 0
4A5-2om.-- -- - ..
_.. .._. O.W
_._n
14.04.
....1331
_ _ _ '0
.....__0
_• .___._.0._.__.
_.. 0
____ '0
_. _._ 0,
-- --. .0
.. . 0:
13A-4ocs
0.143
a
3.72
2.62
0
0
0
0
0
0
0
0
4A5-2om
0.540
a
14.04
28.62
0
0
0
0
0
0
0
0
11
I D
11DO
0.390
a
10_14
11.50
0
0
0
0
0
0
0
0
13A-flocs; . _...� ._..
0:143
s .
3:72
'2.62
-- --0
- 0,
0
- .. _.. __0
..- 0
0
_ 0
_ ..0
-4A5 tom_
_..0�
. s
14:04
_ -13.31
. 0
,. __. -0
.. -"-,-0
_ 0
_.. 0
_ _0
-- 0
... - - 0
Vt/
13A-4ocs
0.143
w
3.72
2.62
122
105
392
276
0
0
0
0
4A5-2om
0.540
w
14.04
28.62
16
0
229
468
0
0
0
0
4A5-2omd
0.540
w
14.04
32.78
0
0
0
0
0
0
0
0
:12C 0sw —
0.091
..
2 37
133
.. ,0
0
..- ._ - 0
0
0
....- - 0
-._ ... , 0
- _,6
D-1.1D0-_.:._.0.390
n__.
10.14-_.11b0
0:_-_--.0.__
.0,.._-_._
0_._.._-0_-----_.__0_----,-._0-----_.0-
C
168-30ad
0.032
0.83
1.70
161
161
134
272
19
19
16
33
F._) ...
r
f...
22A_cpm-
-
_ - .180
..
__.30.68-
_.- _0:00
_.: -.. 161
r .. 26
.. .. _..
_' 798
j.
------ .0
_. .- .
6
c) AL excursion
101
-2
1
Envelope loss/gain
1941
1390
16
31
12
a) Infiltration
480
175
0
0
b) Room ventilation
0
0
0
0
13
Irjtemalgains: Occupants@ 230
1
230
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
2421
1795
16
31
Less extemal load
0
0
0
0
Lesstransfer
0
0
0
0
Redistribution
5
10
-16
-31
14
Subtotal
2426
1805
0
0
15
Ductloads
10%
22%
248
389
10%
22%
0
0
T.I w room load
2674
2194
0
0
Air required (cfm)
0
104
0
0
Calculatiohs approved byACCAto
wrYgFftsoi-!^
Right-SulteOUriversal201818.0.31 RSU16877
ktop\TEMPPRINT1Lot067F1833ARHGDen-N.rLp CaIc=W8 Housefaces:N
2018-Oct-08 10:86:30
Page 6
-- wrightsoft Right-JO Worksheet
Entire House
One Stop Cooling and Heating
7225 Sa soove Court, W inter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.0neStopCoolirg.com License: CAC032444
Job: Lot 067 F1833 A RHG Den - N
Date: 06/07/2017
By: XF/MC
1
Room name
BED3
LAUN
2
3
Exposedwall
Room height
13.0 ft
8.7 ft heaUcool
0, ft
8.7 ft heat/cool
4
5
Room dimensions
Room area
1.0 x 154.8 ft
154.8 m
1.0 x 48.0 ft
48.0 W.
Ty
Constuclion
number
U-value
(Btuh4--F)
Or
HTM
(Btuh/II?)
Area (ft)
or perimeter (ft)
Load
(Btuh)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
11
V+/
L—D
l—G
p
C
—G
13A flocs .,
13A-4ocs
4A5-2om
11 DO
13A flocs' ,
4A52om_.._._ _ ......
13A-4ocs
4A5-26m
4A5-2omd _ -_ ..
12C Osw
1613-30ad
0143
.0540
0.143
0.540
0.390
0143
_Q'540
0.143
0.540
_ 0540
0 091
.0.390
0.032
ri.
n.-
a
a
a
s
w
w
w
, .-.
,nr-
3 72
---- 1404'
3.72
14.04
1014
372
3.72
14.04
1404
_
237
---1014;
262
._._1331
2.62
28.62
11.50
2 62
2.62
28.62
32.78
1:33
-__...11.50
113
-._ .. :16
0
0
0
0
0
0
0
0
117
_.. _.._..0
97
._--- . , 0
0
0
0
0
...:a ._ 0.,,
0
0
_ 0
117
_..._.. -.,_0
1.55
360
..._. __229
0
0
0
0
..,__.0
0
0
0
278
__.._ ._ _ 0
` 253
_ ____ 218
0
0
0
0,
_;-__.._..0
0
0
0
156
.._ _._ 0
0
0
0
0
0
_ ._._ .. 0
0
0
0
57
'_..__.._.18
48
0
0
0
0
0
_.. 0
0.
0
0
39
..._ _.. _:18
48
0
0
0
0
0
-- 0
0
0
0 0
92
,: _ .._._181
40
0
0
0
0
0
0
0
51
_ _....... 206.
81
..M. .,-_..,.
...
.. ..-0.83
_.
_
.._.1.7.0..
...... .,
.--- .155
1,80
w.. _._....,.
._-..
,,._..129
399E1
..._262
-v- ._..n
_._. ..__........_,,
_._
- ..
6
c)IAED
excursion
-77
-54
EMI
velope loss/gain,
1395
812
313
285
12
a)� Infiltration
b)� Room ventilation
240
0
87
0
0
0
0
0
13
i
Internal gains: Occupants @ 230
1
230
0
0
Appliancestother
0
500
Subtotal (lines 6 to 13)
1635
1130
313
785
Less external load
0
0
0
0
Lesstransfer
0
0
0
0
Redistribution
14
27
13
26
14
Subtotal
1649
1157
326
811
15
Duct loads
1 10%
2-2%1
168
249
10%1
229%
33
175
Total room load
1817
1406
359
985
Airrequired (cfm)
0
67
0
47
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
C -�- ,wrigt+tsoft^
Right-SuiteO Universal 2018 18.0.31 RSU16877
ktop\TEMPPRIN\Lot067F1833ARHGDan- N.np Calc=W8 Housefaces:
2018-Oct-0810:3630
Page 7
+ wiHghtsoft
Right-JO Worksheet
Entire House
One Stop Cooling and Heating.
7225 San lscove Coot, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopGooling.corn License: CAC032444
Job: Lot 067 F1833 A RHG Den - N
Date: 06/07/2017
By: XF/MC
1
Room name
H1
2
Exposed wall
0 ft
3
Room height
8.7 it heatl000l
4
5
Room dimensions
Room area
9.5 x 4.0 ft
38.0 fn
Ty
Construction
U-value
Or
HTM
Area
Load
Area
Load
number
(Btuh4l! °c9
(Btuw)
or perimeter (ft)
(Btuh)
or perimeter
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
;AM,flocs
0:143
n -
-72
,2;62
.0
0.;
0
0
VI
:4A5-2om:-.-•- _
13A-4ocs
_ 0:540
0.143
, _n._
a
_ _ 14.04
3.72
_- 13.3i
2.62
. _...._ 0
0
:-_.. _. _...0
0
._ _._ __ _ 0
0
_... _ 0
0
11L-G
yJ { ....13A-4ocs........
�G
V)/ ,
4A5 tom
11D0 _ .
4A5 tom, _ ._ _ _•. _
13A-flocs
OS40
0.390
0.143
. :A.540
0.143
a
-e-
s
.: s.-_
w
14.04
10.14
3.72
. 14.04
3.72
28.62
11.50
. 2.62
•_ 13.31-
2.62
0
� - 0
Oi
_- - _..-- 0
0
0
__. .--0
0
- - -_... _0
0
0
_.-.-_-- 0
. 0
._ _ _`___
0
0
- - ..__-._0
0
_ __..__.._ 0
0
..._�_- -.- -..
.._ .-•----
_ _ _ _,_._.,
_- _ _ .- _
_ .____- --
_-........
-------- •-----
L_GG
4A5-2om
4A5-2omd
0.540
0.540
w
w
14.04
14.04
28.62
32.78
0
D
0
0
0
0
0
0
q
12C Osw _
.0:091
2.37
1:33
`0
: 0
- .0
0
_.t—D-1
C
1DO_ _..-__.---_-_-_._0.390--n-__10.14.___.1150.---..---0
1613-30ad
0.032
0.83
1.70
38
38
32
64
F I ...
I
........
22A cpm .. _
. _....... ._
1.180
. r.
-
30.68
----
. 0:00
-
_
. . . 38
- -
... _-----0
-
._ ...: Q
.. - __0
_
-- - -
-
6
c)i AED excursion
-4
I
Envelope losstgain
32
60
12
a) Infiltration
0
0
b) Room ventilation
0
0
13
Internal gains: Occupants@ 230
0
0
Appliances/other
0
Subtotal (lines6to13)
32
60
Less external bad
0
0
L'esstransfer
0
0
Redistribution
-32
60
14
Subtotal
0
0
15
Ductl0ads
10%
22%
0
0
Total room load
Air required (cfm)
0
0
0
0
Calculations approved byACCA to meet all requirements of
-rld- wrigtitsot-t- 2018-Oct-08102620
" Right-SdteOUniversal 201818.0.31 RSU16877 Page
ktop\TEMPPRINT\Lot067F1833ARHGDan- N.rup Calc=W8 Hocaefaces: N
-- wrightsoft® Duct System Summary
Entire House
One Stop Cooling and Heating
7225 Sar&mve Coat, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax:'(407) 629 - 9307 Web: www.OreStopCoolirg.com License: CAC032444
run . rlyQl 1 r lul r la
External static pressure
Pressure losses
Available. static pressure
Supply/return available pressure
Lowest friction rate
Actual airflow
Heating
0.50
in H2O
0.16
in H2O
0.34
in H2O
0.170/0.170
in H2O
0.228
in/100ft
0
cfm
Job: Lot 067 F1833 A RHG Den
Date: 06/07/2017
By. XF/MC
Cooling
0.50 in H2O
0.16 in H2O
0.34 in H2O
0.170 / 0.170 in H2O
0.228 in/1.00ft
933 cfm
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BED2 !
c 2194
0
104
0.292
6.0
Ox 0
VIFx
11.6
105.0
sti
BEDS
c 1406
0
67
0.291
6.0
Ox0
VIFx
11.8
105.0
sti
BTH1
c 375
0
18
0.266
4.0
Ox 0
VIFx
12.9
115.0
sti
DEN
c 2131
0
101
0.233
6.0
Ox 0
VIFx
35.7
110.0
st2
DIN
c 2344
0
111
0.234
6.0
Ox0
VIFx
35.1
110.0
st2
GRT
c 3684
0
175
0.228
8.0
Ox 0
VIFx
29.2
120.0
st2
KIT I
c 2200
0
104
0.253
5.0
Ox 0
VIFx
24.5
110.0
st2
LAUN
c 985
0
47
0.466
4.0
Ox 0,
MR
3.0
70.0
MBED1
c 3466
0
164
0.240
7.0
Ox 0
VIFx
31.4
110.0
st2
MBTH',
c 748
0
35
0.230
4.0
Ox 0
VIFx
32.9
115.0
st2
MWIC
c 149
0
7
0.239
4.0
Ox0
VIFx
27.0
115.0
st2
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FR
(fpm)
(in)
(in)
Material
Trunk
st2
PeakAVF
0
698
0.228
653
14.0
0 x 0
VinlFlx
sti
PeakAVF
0
188
0.266
705
7.0
0 x 0
UnlFlx
I
-�- wrightsoft® 2018-Oct-0810631
,i �NR•� ��� ,� �, Rigt¢-& te®Uriversal2018 18.0.31 RSU16877 Page 1
ACCK
...ktop\TEMPPRIN-RLot087F1833ARHGDan- N.rup Calc=MA Hosetaces:N
Name,
Grille
Size
Htg
Clg
TEL
Design
FIR
Veloc
Diam
H x W
Stud/Joist
Opening
Duct
Mail
Trunk
(in)
(cfm)
(cfm)
(ft)
(fpm)
(in)
(in)
(in)
rbi
Ox 0
0
933
0
0
0
0
Ox 0
VIFx
wrightsoft® 201B-Oct-08103631
ti; ♦uRN/mWmwwyCompy Rigfrt-Suite®Uriversal20181B.0.31RSU16877 Paget
AM, - ...ktop\TEMPPRIN-RLot067F1833ARHGDen- Map CaIc=W8 Hoisefaces: N
Static Pressure and Friction Rate Job: Lot 067 F1833 ARHG Den
i/ilghtsoFt° Date: 06/07/2017
Entire House By: XF/MC
One Stop Cooling and Heating
7225 Sar&cove Coin, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwaOneStopCooling.com License: CAC032444
For: Ryan Homes
External static pressure
Pressure losses
Coil
Heat exchanger
Supply diffusers
Return grilles
Filter
Humidifier
Balancing damper
Other device
Available static pressure
Measured length of run -out
Measured length of trunk
Equivalent length of fittings
Total length
Heating
Cooling
(in H2O)
(in H2O)
0.50
0.50
0
0
0
0
0.03
0.03
0.03
0.03
0.10
0.10
0
0
0
0
0
0
0.34 0.34
supply
Return
(ft)
(ft)
9
0
20
0
120
0
149 0
Heating Cooling
(in/100ft) (in/100ft)
Supply Ducts 0.228 > 0.18 0.228 > 0.18
Return Ducts 0.228 > 0.18 0.228 > 0.18
4X=35,11 A=20,11 G=5,11 G=5,11 G=5,1 A=35,11 G=5,11 G=5,11 G=5: Total EL=120
Total EL=O
I
I
i
'Aw WCIFghtsoft, Right-SLite®Universal 201818.0.31 RSU16877
...ktop\TEMPPRIN'RLot067F1833ARHGDen- N.rup CaIc=W8 Housefaces: N
2018-Oct-08 10 36:31
Page 1
Job #: Lot 067 F1833 A RHG Den - N
Performed by XF/MC for:
Ryan Homes
Level 1
AC RODS BYGC MIN SIZE
40'X40'
35' SEPARATION
W OFF WALL
"PVC REFRIGUNEC BY
. GC
EF1 = 50 CFM Fan
EF2 = 80 CFM Fan
EF3 =110 CFM Fan
EFL1 = 50 CFM Fan
EFL2 = 80 CFM Fan
EFL3 = 110 CFM Fan
VTR = Vent to Roof
VTW = Vent to Wall
DV = Dryer Vent
RV = Range Vent
— — = Lineset Chase
= Condensate
OT = Thermostat 18/8
SRB = Small Reduction Box
LRB = Large Reduction Box
FBB = Feld Built Box
One Stop Cooling and Heating
7225 Sandsmve Court
Winter Park, FL32792
Phone: (407) 629 - 6920 Fax (407) 629 - 9307
wwwDneSbpCooli ng.mm
Scale: 1 : 63
Page 1
Rght-Site® Universal2018
1B.0.19 RSLJ23249
2718•Sep-0608:14:0B