Loading...
HomeMy WebLinkAboutD O H SEWAGE TREATMENT - DISPOSAL PERMITSTATE OF FLORIDA 9, DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION PERMIT c� wE I CONSTRUCTION PERMIT FOR: ~-[ X ] Ne� System [ ]Existing System "[ ]Repair [ ]Abandonment APPLICANT: Saitta, Walter [ ]Holding Tank [ [ ]Temporary [ CENTRAX #: 56-SF-08239 DATE PAID: FEE PAID $ RECEIPT OSTDSNBR 05-0324- -N ] Innovative Other AGENT:MICHAEL GRZELKA PROPERTY1 STREET ADDRESS: Tilton Rd Port St. Lucie FL 34952 LOT: 7 BLOCK: 3 SUBDIVISION: St. Lucie Gardens .[Section/Township/Range/Parcel No.] PROPERTY ID #: --- [OR TAX ID NUMBER] SYSTEM MUST^BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF CHAPTER 64E-6,FAC ,DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC TIME PERIOD. ZANY CHANGE IN MATERIAL FACTS WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS'MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE OR LOCAL PERMITTING REQUIRED FOR PROPERTY DEVELOPMENT. i SYSTEM DESIGN AND SPECIFICATIONS T [ 1050 ]Gallons SEPTIC TANK MULTI-CHAMBERED/IN SERIES: [Y ] A [ 0 ]Gallons MULTI-CHAMBERED/IN SERIES: [Y ] N [ 01 ]GALLONS GREASE INTERCEPTOR CAPACITY K [ 300i ]GALLONS DOSING TANK CAPACITY [ 75 ]GALLONS @ [4 ]DOSES PER 24 HRS # PUMPS[ 1 ] D I [ 615 ]. SQUARE FEET PRIMARY DRAINFIELD SYSTEM % 7 � �L ) I "� R [ 0 ]SQUARE FEET SYSTEM ✓ �f fn TYPE SYSTEM: ( N ]STANDARD ( N ]FILLED [ Y ]MOUND [ N ] I CONFIGURATION: [ N ]TRENCH [ Y ]BED [ N ] N IF LOCATION TO BENCHMARK: Nail In Power Pole Near NW Prop. Corner - 20.02 NGVD OF PROPOSED SYSTEM SITE [ ] [ INCHES ] [ BELOW] BENCHMARK/REFERENCE POINT I ELEVATION E BOTTOM OF DRAINFIELD TO BE [ 6.0 ] [ INCHES ] [ ABOVE ]BENCHMARK/ REFERENCE POINT L ,.D FILL REQUIRED:[ 42.0 ]INCHES EXCAVATION REQUIRED: [ 84.0 ] INCHES OTHER RE -The lice category au uonr-rauzor a.nsta.L.Ling the system.is responsible for installing the minimum f tank in accordance with s. 64E-6.013(3)(f), FAC. Excavate153'xl4'x7' deep. ` Audio and visual alarms must be installed and working at time of final inspection. S'PECIFICA APPROVED NS BY: POLISSKY, JODI TITLE: Polissky, Jodi TITLE: Environmental Spec St. Lucie CHD DATE ISSUED: 6/7/05 DH 4016, 03/97 (Obsoletes previous editions which may not be used) (Stock Number: 5744-001-4016-0) [ostds_cons_4016-11 EXPIRATION DATE: 12/7/06 Page 1 of 2