NOA ALUMINUM HORIZONTAL SLIDING WINDOW - 10-16-03
MIAM FDADE BUILDING CODE COMPLIANCE OFFiCE (BCCO) PRODUCT CONTROL :DIVISION NOTICE OF ACCEPTANCE '(NOA) MUM-DADE COUNTY, FLORIDA METRO -DARE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAb% FLORIDA 33130-1563 (105) 375-2961 FAX (305) 375-2908- PGT Ltdustrles NGANNED 1070 Technology Drive' ;y Nokomis, F1, 3427.4 ., St Lucie County Scoria: This NOA is being, issbed under the applicable rules.and regulations governing the use of construction materials. The -documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BURA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it -is determined by Miami -Dade County. Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "HS 710" Alun lnum Horizontal Sliding Window APPROVAL DOCUMENT: Drawing No.4112, titled "Aluminum Horizontal Sliding Window", sheets 1 through 6 of 6, prepared by PGT Industries, dated 2116198, with revisions 12/29/03 signed sealed by Robert L. Clark, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by.the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this.NOA will occur after the expiration date or if there has been a revision or change in the materials_, use, ON manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for _salts, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this•NOA shall be cause for termination and removal of NOA. ADVERTISE MM: The NOA number preceded by the words Mann -Dade County, Florida, and followed by the expiration date' may-be,.displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety, INSPECTIONt A copy,of this `entire NOA shall be provided to the user by the manufacturer or its distributors and'shall be available for:inspection at the job site.at the request of the.Building Official. This NOA revises NOA #:02-0305.02 and, consists of this page 1 and evidence page E-1 and E-2, as well as approval document mentioned above. The -submitted documentation was.reviewed by Theodore Berman, P.E. NOA No 03-0612.06 Expiration Date: May 20, 2007 r Approval Date: April 08, 2004 Page 1 Ir 1. GLAZING OPTIONS: 1 A 5/16" (.350) LAMINATED CONSISTING OF AN .090 PVB INNER LAYER OF 2 DUPONT BUTACITE OR SAFLEX/KEEPSAFE MAXIMUM BETWEEN (2) LITES OF 3 1/8" ANNEALED GLASS. 4 A 5/16 (.350) LAMINATED CONSISTING OF AN .090 PVB INNER LAYER OF 5 DUPONT BUTACITE OR,SAFLEX/KEEPSAFE MAXIMUM BETWEEN (2) LITES OF 6 AG 1/8'. HEAT STRENGTHENED GLASS. 7 C. 13/16" LAMI I.G. GLASS CONSISTING OF: 1/8• HEAT STRENGTHENED GLASS. 9 3/8" AIR SPACE AND 5/16" LAMINATED GLASS. THE 5/16" LAMINATED 10 COMPONENT CONSISTS OF AN .090 P/B-LAYER OF DUPONT OR 11 SAFLEX/KEEPSAFE MAXIMUM BETWEEN (1) LITE. OF 1/8" ANNEALED GLASS 12 --AND (1) LITE OF HEAT STRENGTHENED GLASS, 13 D. 13/16• LAMI'I'.G. GLASS CONSISTING OF: 1/8' HEAT STRENGTHENED GLASS, 15 3/8" AIR SPACE AND 5/16" LAMINATED GLASS. THE 5/16• LAMINATED 16 COMPONENT CONSISTS OF AN :090 PIB LAYER OF DUPONT OR 17 SAFLEX/KEEPS4FE MAXIMUM BETWEEN (2) UTES OF 1/8" HEAT 18 `STRENGTHENED CLASS- ' 2. CONFIGURATIONS: XO qs OX 19 3. DESIGN PRESSURE RATING: SEE TABLES I-3 ON SHEET 2 20 21 22 23 7e MAX WIDTH 24 33 5/8- MAX 33 5/8' MAX 25 .. - DAYLIC4T DAYLIGHT 26 OPENING OPENING G 27 29 30 31 - 32 58 1/4" MAX FIXED LITE' DAYLIGHT ` 57" MAX OPENING VENT DAYLIGHT OPENING 63- MAX HEIGHT 1 ----� x DESCRIPTION QTY./LOCATION - - - --- -.._.. .... __ _ - . m �...... , 6 I.G.. 1 8 HEAT STRENGTHENED GLASS. 3 8 0W 5 16 LA6 4. ANCHORAGE: SINGLE ROW OF FASTENERS LOCATED AS FOLLOWS HEAD & SILL: MAX. 6' FROM CORNERS. MAX. 4" & B" ON EACH SIDE OF MEETING RAIL CENTERLINE. MAX. 15" SPACING. JAMBS: MAX ;" FROM LORNERS. MAX 12 1/2" SPACING. 5. SHUTTER REOUIRENENT: NO SHUTTERS REO'D. F.K. 19129, 6. REF. TE°;T REPORTS: FTL-1969 & FTL-3740 FK 7 23 F-K.. • 4 0, I ' F.K. B/0: 6" MAX 6�- e" MAX ' 6• MAX --�. �r I I I OX. F_LEUA 4" MAX - 4" :MAX 1070 TFx11NOLOGY DRNE LMr ll NOKOYIS. n u:7s ALUMINUM SEE t .4 ON. MEETING RAIL ANCHORAGE tmwnL axk a.E Po eo:i tszs VENDOR SHT 5- ? D-RENSEO NOTE T 98 , TION & . $. 0. M. ' �etra7tz Nomurs. a 3A17A u� Alrc I r ` s DIE COMPARATIVE ANALYSIS TABLE 1. GLASS TYPES A & C FTL-1969 & FTL-3740 A. 5/16" LAMINATED (1/8" ANNEALED, .090 PVB, 1/8" ANNEALED) C. 13/16" LAMI I.G. -1/8"HEAT STRENGTHENED, 3/8" SPACE, 5/16 LAMI (1/8"HEAT STRENGHTENED, .090 PVB, 1/8-ANNEALED) vi11NDOW - WINDOW HEIGHTS WIDTHS 1 26.000 1 38.375 1 44.000 1 50.625 1 ' 59.000 1 60.000 1 61.000 1 62.000 1 63_nnn B. 5/16" LAMINATED (1/8" HEAT STRENGTHENED, .090 PVB, 1/8" HEAT STRENGTHENED) D. 13/16" LAMI I.G. -1/8"HEAT STRENGTHENED, 31V SPACE, 5/16 LAMI (1/8"HEAT STRENGTHENED, .090 PVB,1B"HEAT STRENGTHENED) WINDOW - _ WINDOW HEIGHTS WIDTHS •. 26.000 1 38.375 1 .44.000 1 50.625 1 59.000 1 60.000 1 61.000 62.000 1, 63.000 26.500 66.7 -75.0 1 66.7 -75.0 66.7 -75.0 66.7 -75.0 65.7 -75.0 66.7 1 -75.0 1 66.7 1 -75.0 1 66.7 1 -75.0 1 66.7 - 75.0 37.000 - 66.7 -75.0 66.7. -7a.0 66.7 1 -75.0 1 66.7 -75.0 66.7 -75.0 66.7 1 -75.0 1 56.7 1 -75.0 1 65.7 1 -75.0 1 66.7 1 -75.0 44:000 6R_7 I -75-0 I 6B 7 ' _75 n I RR 7 1 -75 n RR 7 1 -7.ri n I RR 7 1 _7F n I RR 7 1 -74 n I RR 7 1 _72% n I RR 7 1 _7r, n I RR 7 1 '= n - -75.0 66.7 -75.0 68.7 -75.0 66.7 -75.0 66.7 -76.0 66.7; - -75.0 66.7 -75.0 66.7 -75.0 66.7 -75.0 66.7 -76.0 66.7 , - 75 0 e -/J.V vv.r 66.7 -75.0 66.7 -75:0 66.1 _-75.0 66.7 -74.9 66.7. 66.7 -I3.0I CEO.! I -(z.3 -70.9 66.7 -69.6 74.000 . .66.7 -75.0' .•66.7 1 -75.01 06.7. -75.0 66.7 -75.0 65.7 -74.8 66.7 -73.5 66.7 -72.2 F.K. 12 29 0 F-UPDATE TABLES F.K.`LOADS 7 2J OJ F-CORRECT TABLE J TAC hQTES//OTf- . .DESIGN - ROWL F. 44 03 MI: f�1OD t 76' L& 1fS A. NEGATIVE BASED ON TESTED .PRESSURE AND GLASS TABLES ASTM E 1300-98'(AND,ASTM. E 1300-94 OUTSIDE MIAMI-DADE COUNTY). F. 9 6/02 D-RcNSED TABLES D.B. 16 98 B. POSITIVE DESIGN LOADS BASED ON WATER. TEST PRESSUREAND GLASS TABLES yp mpg GLASS TYPE COMPARATIVE ANALYSIS ASTM E 1300-98 (AND.,ASTM E 1300-94 OUTSIDE MIAMI-DADE COUNTY). EMI n"" ALUMINUM HORIZONTAL SLIDING WINDOW C. DESIGN PRESSURES''UNDER 40 P.S.F. NOT APPLICABLE IN MIAMI-DADE COUNTY. ` ��� Imo tocNNOLoor oK NOXomm. FL 34275 .. • - LCWk P.E. �� 1? P.O. BOX 1529 NONONS, FL 34274 Sb4!/No!'h HS-710 S-W NT,S SMet 2 a 6 P-ft ft. 41 12 ' R�r. G i 5/16" LAMINATED 13/16 NOM. 1/8" HEAT STRENGTHENED GLASS 12 13 .099 SAFLEX KEEP/SAFE MA)UMUM T ASS 1/2• = G OR DUPONT PVB INTER LAYER. : OUTSIDE ITE QUISIDE GLASS 1/8" BITE AN OR HEATINSID STRENGTHENED GLASS 5 5 INSIDE ^' ; - 3/87 AIR SPACE 6 '- 1/8" HEAT 1/8" HEAT ' ��• STRENGTHENED 1/8" ANNEALED GLASS-� STRENGTHENED —� 090 INNER LAYER s.. GLASS. O GLASS (DUPONT BUTACRE OR .090 INNER. LAYER Q SAFLEX/KEEPSAFE MAXIMUM) (DUPONT W/BUTACITE OR 1/B' HEAT SAFLEK/KEEPSAFE MAYJMUM) STRENGTHENED 1/2" ,CLASS ®9 OR 2 _ GLASS 1/8" ANNEALED GLASS 17f B p- s = ' GLAZING DETAILS: 5f 16" 350) LAMINATED GLASS .' OUTSIDE ;INSIDE) F.K. 12 29 C-tZE3tllEllkli?spAaS Tin F.K. 7 23 0T F-8FH 17 SWE Rld FK.: 4 4 OJ f--ADD 43116, 1.G. � ,F.K.•. 976102 0-ADD G1A55 ME t ES GLAZING' DETAIL.St 13�16" (8�5� I /1vIle D 8. 2116 98 ` l4 cl SECTIONS & ~ GLAZING DETAILS 1070 TEC1010LOCY DRIVE' ' NOXOMM. FL 34275 ALUMINUM HORIZONTAL SLIDING WINDOW L CWk P.E P.O. BOIL 157u SUNs/YoO.t S�k - O,vwp ft - Rx REFERENCE -EST R PORTS , FTL--1969 & Fr'L-3740 PE7R0712• Nq(oN15, FL ss27a sww,.l rFs-710; NT§ •-3 �' 6 " 41 12 G r— 2.710 EXTERIOR Max. WIDTH _ ROUGH _ .500 FIXED,'III AYUGIfr e OPE ��,♦� HEIGIfr WC • i 5 ,1 ,. ROUGH J OPENING 5 VERTICAL SECTION ROU OPEN MAX. VENT DAYLIGHT OPENING i1��iYi IY1Y� ll1070 PE 039712P E swae,x TF.K. IN 6/02 D D GfASS TYPE D.B.r. 16 98 SECTIONS & GLAZING DETAILS NOKOM uz°� P.O. BOX 1529 NOKous. FL 3274 m.: ALUMINUM HORIZONTAL SLIDING /V0 HS-710 Soa NTS 3M.0 4 d 6 -"'o Na 4112 -T APPROVED : �. 1 WOOD BUCK 1 1/4" MIN. (SEE NOTE 4.) ::.� �• . • .: t .. 1 1/4" MAX. SHIM Q3/16" TAPCON (SEE NOTE 1) TYPICAL HEAD' SECTION SUBSTRATE ANCHORING APPROVED 2x WOOD BUCK (SEE NOTE 3.) Maul 1 1/4' MIN. 1 /4" MAX. SHIM #12 WOOD SCREW Q TYPICAL HEAD SECTION WOOD ANCHORING NOTES: 1. USE ONLY MIAMI-DADE COUNTY APPROVED ELCO TAPCONS. 2. REFERENCE TEST REPORT: FTL-1969 do FTL-3740 3. INSTALLATION OF 2x WOOD BUCK TO THE SUBSTRATE ENGINEERED SEPARATELY AND TO BE REVIEWED BY BUILDING OFFICIAL.' 4. INSTALLATION OF 1x WOOD BUCK TO THE SUBSTRATE TO BE ENGINEERED SEPARATELY. 1 1/4" MIN. 1/4" MAX. SHIM I #12 WOOD SCREW 1 1/4" MIN. ©3/:6" TAPCON (SEE NOTE 1) //�� © 012 WOOD SCREW APPROVED APPROVED Ll3/16" TAPCON WOOD BUCK 2x WOOD BUCK (S41) (SEE NOTE 4.) (SEE NOTE 3.) TYPICAL JAMB SECTION TYPICAL JAMB SECTION SUBSTRATE ANCHORING WOOD ANCHORING 1/4" MAX. SHIM�r SHIM _ , a'•.. 1� MIN. m� mftfm plahakNow F.K. 12 29 03 6-0C 16' A4XM /11 AR 1 1/4" MIN. -- F.K. 7123103 ZF;R5WIf 3116 IAAL17A6 :1 ' '� T • • • ',. - F. 414 03 E—NO CNO TNfS SHT APPROVED F. 9 6/02 I= NOTES J k 4 2x WOOD BUCK (SEE NOTE 3.) y INE)US On." TYPICAL SU SECTION TYPICAL " I L SILL SECTION / ANCHORAGE SUBSTRATE ANCHORING W000 ANCHOING 1/16 wk '0'NOKOM� 2775 ALUMINUM HORIZONTAL SLIDING WINDOW Hob.rt N3971 PE P.O. BOX 1529 a..■/Moac sn..t 6v*v No. R■�. s Nm°7ro NO'�s. FL u274 HS-710 NTS 5 of 6 1 411.2 G r --�{ 1--- .705 062 2.784 - �-�- .737 10 FLANGE FRAME JAMB 6063-T5 ALUM. 1.057 678 .050 0 5/16" GLAZING BEAD 6063-T5 ALUM. 1.187 -1 F-- 2.0j7 4 4_L .062 90 FRAME SILL ADAPTER 6063-T5 ALUM. 1.187 . .062 1.403 Q FIXED MEETING RAIL 6063HS-T54 ALUM. 062 - ++ .723 .688 - �i ©WIND LOAD ADAPTER 6063-T5 ALUM. 062 1 - 1�.1-83 1.349 1 10 SASH TOP & BOTTOM RAIL 6063-T5 ALUM. REFERENCE TEST REPORTS: FTL-1969 & FTL-3740 .062 1.18 1.0817 Q SASH MEETING RAIL 6063HS-T54 ALUM. .062� 1.373 I 1.273 f� 2.710 - I —7 Q FLANGE FRAME HEAD 6063-T5 ALUM. 1.097 .683 oso ®0 13/16" GLAZING BEAD F.K. 6063-T5 ALUM. F.KRond W. ,�j T F.K. EXTRA / 1c1 fro. � 1070 s"FNa IL 34275 ALUM �h.Wyk P.E P.O. BOX 1529 t59a9n2 NOXO - FL — wuW..f HS-710 .062 ' 1.349 F+—�- 1.291 1.970 If�- ®SASH SIDE RAIL 6063-T5 ALUM. .062 —ten 2.094 1.122 ® FLANGE FRAME SILL 6063-T5 ALUM. raoeua� A+y�.rfpAdl� 1 � rW. I PROFILES HORIZONTAL SLIDING WINDOW z4: prp.{np NTS 6 6 4112 G "1 r