Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEMAKHNI RESIDENCE FLORIDA ENERGY EFFICIENCY CODE • FOR BUILDING CONSTRUCTION Section 9 Compliance Program --Residential Point System Method Version 2.0 January, 1989 " Department of Community Affairs Printout generated by EPI89 and submitted in lieu of Form 900-A-89 THIS COMPLIANCE FORM IS VALID IF SUBMITTED BEFORE JANUARY 1, 1990 ---=----------------------------_----------------------------------------------- PROJEC`I' NAME: M�KF'!'N I .R�SI D�I PERMITTING OFFICE: ----------- ANDI ADDRESS: 33 �3 ►?/,�/(%�� �j�. I CLIMATE ZONE: -- 4 5 6 -- - ------ I------------- BUIILDER : Tfla N k_Cd jx e��W / G' i PERMIT NO.: -------------- ------------------------------ I I JURISDICTION NO.: OWN11ER: l---------------------- ---- ---'---------------------------------------------------------------------------- BUILDING OFFICIAL COMPONENT VALUE CHECKLIST STRUCTURE TYPE: ����� Single -Family BY PREDOMINANT EVE OVERHANG Length: 3.00 at Lucie County PORCH OVERHANG Length: 16.00 WINDOWS Single Tint Total Area: 1812.2 Double Tint Total Area: 45.0 WALLS 1.; Ext NormWtBlock Int Area: 3118.0 R-Value: 8.2 2.1 Ext Wood Frame Area: 240.0 R-Value: 11.0 3.! Adj Wood Frame - Area: 396.0 R-Value: 11.0 DOORS 1.1 Ext Insulated Area: 40.0 2.1 Adj Insulated Area: 20.0 CEILINGS 1.1 FLAT Under Attic Area: 2692.0 i R-Value: 19.0 2: PITCHED Under Attic Area: 693.0 R-Value: 19.0 FLOORS li Slab -on -Grade Perim: 253.0 R-Value: 0.0 DUCTS Uncond. Space Length: ALL 7 R-Value: 6.0 COOLING 1. Central A/C SEER: 10'.00 _ Multizone: Credit Ceiling Fan: Credit HEATING , 1!. Strip Heat STRIP: 1.00 i Multizone: Credit HOT WATER Bedrooms: 5 1. Electric EF: 0.88 Heat Recovery: w/A.C. INFILTRATION Practice: 2 Conditioned Floor Area: 6032.0 AS BUILT'POINTS / BASE POINTS * 100 = EPI % 106364.4 110736.2 96.1 / GLASS TO FLOOR AREA RATIO = 0.3079 ** PRESCRIPTIVE MEASURES (Must be met or exceeded by all residences) ** COMPONENTS SECTION REQUIREMENTS WINDOWS 904.1 Maximum of 0.5 CFM per linear foot of operable sash crack. -------------------------------------------------------------------------------- EXTERIOR & 904.1 Maximum of 0.5 CFM per sq. ft. of door area. ADJACENT DOORS Includes sliding glass doors, solid core, wood panel, insulated, or glass doors only. ------------------------------------------------------------------------------- EXT. JOINTS & 904.1 To be caulked, gasketed, weatherstripped or CRACKS I otherwise sealed. ------------------------------------------------------------------------------- WATER HEATERS 904.2 Must bear label indicating compliance w/ASHRAE standard 90 or comply with efficiency and standby loss requirements. Switch or clearly marked circuit breaker (electric), or -cut-off (gas) must be provided. An external or built ------------------------------------------------------------------------------- in heat trap must be provided. SWIMMING POOLS 904.3 Spas and heated pools must have covers (except & SPAS solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have minimum thermal efficiency of 75% ------'------------------------------------------------------------------------ HOT WATER 904.4 Insulation is required only for recirculating PIPES systems. In such cases, piping heat loss shall be limited to 17.5 BTU/H/Linear Ft. of pipe. ------------------------------------------------------------------------------- SHOWERIHEADS 904.5 Water flow must be restricted to no more than 3 Igallons per minute at 80 PSIG. ----- ------------------------------------------------------------------------- HVAC DUCT 903.2 Constructed in accordance with industry CONSTRUCTION 904.6 standards & local mechanical codes. Ducts in Unconditioned space must be insulated to minimum R-4.2 & joints must be sealed. ------,------------------------------------------------------------------------ HVAC CONTROLS 904.7 Separate readilyaccessible manual or automatic thermostat for each system. INSULATION 904.9 Ceilings -Min R-19. Common Walls - Frame R-11 or CBS R-3. Frame Common Ceilings & Floors R-11. ` ** INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST ** -------'--- --------------------------------------------- COMPONENTS REQUIREMENTS PRACTICE #2 Comply with Practice #1 and the following. -------T---- ------------------------------------------------------------------- Exterior` Walls & Floors Top plate penetrations sealed. Infiltration barrier installed. Sole plate/floor joint caulked or sealed. Exterioi Walls & Ceilings Penetrations, joints and cracks on interior surface caulked, sealed, and gasketed Ductwork Ductwork in unconditioned space must be sealed. Fireplaices Equipped with outside combustion air, doors, and flue dampers. Exhaus Fans Equipped with dampers. Combustion devices see 903.2 (f). Combustion Appliances Provided with outside combustion air. ------'------------------------------------------------------------------------ ------------------------------------------------------------------------------- In Accordance with Sec. 553.907 F.S., I Review of the plans and specifications I Hereby certify that the plans and I covered by this calculation indicates specifications covered by this calcu- I compliance with the Florida Energy lationIare in compliance with the I Code. Before construction is completed Florida Energy Code. I this building will be inspected for I compliance in accordance with Section 1553.908 F.S. i OW*FrR/ GENT: BUILDING OFFICIAL: %gyp DNIIE : 9� �/ W 1 DATE: xxxxxxxxxxxxXxxxxxxxxxxxxxxxxxxxxXxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx SUMMER CALCULATIONS BASE ___ { __= AS -BUILT GL-ASS________________________�_________________________________________________ ORIEN AREA x BSPM = POINTS I TYPE SC ORIEN AREA x SPM x SOF = POINTS ---'---------------------------------------------------------------------------- N: 224.0 47.8 10707.2 1 SGL TINT N 128.0 51.5 0.78 5135.8 { SGL TINT N 96.0 51.5 0.85 4207.9 NE 191.0 71.7 13694.7 1 SGL TINT NE 64.0 76.6 0.49 2396.7 1 SGL TINT. NE 64.0 76.6 0.82 4028.1 1 SGL TINT NE 63.0 76.6 0.39 1894.6 E 750.0 102.0 76500.0 1 SGL TINT E 96.0 107.1 0.56 5773.5 1 SGL TINT E 96.0 107.1 0.84 8613.7 1 SGL TINT E 128.0 107.1 0.84 11484..9 1 SGL TINT E 36.0 107.1 0.68 2635.8 1 SGL TINT E 84.0 107.1 0.68 6150.3 1 SGL TINT E 112.0 107.1 0.68 8200.4 1 SGL TINT E 198.0 107.1 0.77 16309.2 SE 120.0 104.1' 12492.0 1 SGL TINT SE 120.0 110.3 0.71 9349.4 S 169.0 90.9 15362.1 1 SGL TINT S 144.0 98.3 0.99 .13949.1 I SGL TINT S 25.0 98.3 0.97 2381.5 SW 74.0 104.1 7703.4 1 SGL TINT SW 31.0 110.3 0.62 2118.7 1 SGL TINT SW 43.0 110.3 0.42 1992.0 W 284.2 102.0 28988.4 1 SGL TINT W 25.0 107.1 0.83 2225.6 1 SGL TINT W 93.0 107.1 0.64 6336.7 1 SGL TINT W 93.2 107.1 0.41 4092.5 1 SGL TINT W 13.0 107.1 0.70 974.2 1 SGL TINT W 35.0 107.1 0.62 2321.2 I SGL TINT W 25.0 107.1 0.98 2631.5 NW 45.0 71.7 3226.5 1 DBL TINT NW 45.0 63.4 0.58 1662.1 --I -------------------------------------------------------------------- .115 x COND. FLOOR / TOTAL GLASS = ADJ. x GLASS = ADJ GLASS { GLASS AREA i ------------------------------------------------------------------------------- AREA FACTOR POINTS POINTS I POINTS I .15 6032.0 1857.2 0.487 168674.3 82175.6 1 126865.4 AREA I ------------------------------------------------------------------------------ x BSPM = POINTS 1 I TYPE R-VALUE AREA x SPM = POINTS WALLS----------- I Ext 3358.0 1.00 3358.0 1 Ext NormWtBlock Int 8.2 3118.0 0.68 2120.2 1 Ext Wood Frame 11.0 240.0 1.90 456.0 Adj 396.0 0.70 277.2 1 Adj Wood Frame 11.0 396.0 0.70 277.2 DiOORS----------- I Ext 40.0 4.80 192.0 I Ext Insulated 40.0 4.80 192.0 Idj 20.0 1.60 32.0 1 Adj Insulated 20.0 1.60 32.0 CEILINGS---------- 1 I UA 3312.0 0.60 1987.2 1 Under Attic 19.0 2692.0 1.10 2961.2 I 1 Under Attic 19.0 693.0 1.10 762.3 FLOORS---------- I I Slb 253.0 -31.80 -8045.4 1 Slab -on -Grade 0.0 253.0 -31.90 -8070.7 INFILTRATION --------- 6032.0 10.90 65748.8 1 Practice #2 6032.0 10.90 65748.8 TOTAL SUMMER POINTS I 145725.4 1 191344 ------------ 1 'TOTAL x SYSTEM = COOLING I TOTAL x CAP x DUCT x SYSTEM x CREDIT = COOLING SUM PTS MULT POINTS I COMPON RATIO MULT MULT MULT POINTS ------------------------------------------------------------------------------- 145725.4 0.43 62661.9 1 191344.5 1.000 1.102 0.340 0.774 55508 ------------------------------------------ xxx*�XXxxx*xxxxxxxxX*x***x**x***X**x**X***xxxxxxx****x*xx*xxxx*xxxx*xx*xx*xxxxxx D WINTER CALCULATIONS •X*X*,*XX*,XX***Yc**XXX*XXXX**X******XX***X*X**XX******XX**XX****xX**XX*X****,X**XX* BASE __= I =_= AS -BUILT -GeLASS------------ I ORIEN AREA x BWPM = POINTS I TYPE SC ORIEN AREA x WPM x WOF = POINTS --- 7--------------------------------------------------------------------------- NI 224.0 5.6 1254.4 1 SGL TINT N 128.0 9.6 1.14 1395.2 I 1 SGL TINT N 96.0 9.6 1.09 1004.0 NEi 191.0 3.5 668.5 1 SGL TINT NE 64.0 7.3 1.51 705.5 ! { SGL TINT NE 64.0 7.3 1.17 548.3 I SGL TINT NE 63.0 7.3 1.60 738.0 E 750.0 -5.6 -4200.0 I SGL TINT E 96.0 -2.0 -1.65 316.7 I SGL TINT E 96.0 -2.0 0.12 -23.4 I SGL TINT E 128.0 -2.0 0.12 -31.2 I SGL TINT E 36.0 -2.0 -0.76 54.7 I SGL TINT E 84.0 -2.0 -0.76 127.5 I SGL TINT E 112.0 -2.0 -0.76 170.0 I SGL TINT E 198.0 -2.0 -0.26 103.5 SEi 120.0 -13.4 -1608.0 1 SGL TINT SE 120.0 -9.7 0.66 -769.3 S' 169.0 -14.0 -2366.0 1 SGL TINT S 144.0 -10.2 0.99 -1456.9 I SGL TINT S 25.0 -10.2 0.98 -250.6 SWI 74.0 -13.4 -991.6 1 SGL TINT SW 3.1.0 -9.7 0.54 -162.1 1 1 SGL TINT SW 43.0 -9.7 0.05 -20.9 W 284.2 -5.6 -1591.5 1 SGL TINT W 25.0 -2.0 0.09 -4.3 1 SGL TINT W 93.0 -2.0 -1.08 200.4 I SGL TINT W 93.2 -2.0 -3.13 582.8 I SGL TINT W 13.0 -2.0 -0.65 17.0 I SGL TINT W 35.0 -2.0 -1.20 83.9 I SGL TINT W 25.0 -2.0 0.90 -45.0 NW 45.0 3.5 157.5 1 DBL TINT NW 45.0 4.2 1.63 307.4 ------------------------------------------------------------------------------ .15 x COND. FLOOR / TOTAL GLASS = ADJ. x GLASS = ADJ GLASS I GLASS AREA AREA FACTOR POINTS POINTS I POINTS --=---------------------------------------------------------------------------- .15 6032.0 i 1857.2 0.487-8676.7 -4227.2 I 3591.2 BWPM ------------- I = POINTS -I--TYPE ------------R_VALUE ------------------------- AREA x WPM = POINTS ------AREA--x WALLS----------- 1 Ext 3358.0 1.10 3693.8 I Ext NormWtBlock Int 8.2 3118.0 2.06 6423.1 I I Ext Wood Frame 11.0 240.0 2.00 480.0 Adj 396.0 1.80 712.8 I Adj Wood Frame 11.0 396.0 1.80 712.8 j DOORS----------- I I . Ext 40.0 5.10 204.0 I Ext Insulated 40.0 5.10 204.0 Adij 20.0 4.00 80.0.{ Adj Insulated 20.0 4.00 80.0 CEILINGS---------- I I UA 3312.0 0.60 1987.2 1 Under Attic 19.0 2692.0 1.00 2692.0 I Under Attic 19.0 693.0 1.0.0 693.0 FLOORS ----=----- I I Slb 253.0 -1.90 -480.7 1 Slab -on -Grade 0.0 253.0 2.50 632.5 INFILTRATION--------- I 6032.0 4.10 24731.2 1 Practice #2 6032.0 4.10 24731.2 TOTAL WINTER POINTS I 26701.1 1 40239.8 TOTAL x SYSTEM = 1 HEATING 1 TOTAL x CAP x DUCT x SYSTEM x CREDIT = HEATING WIN PTS MULT POINTS I COMPON RATIO MULT MULT MULT POINTS -=----------------------------------------------------------------------------- 26701.1 1.14 30439.3 1 40239.8 1.000 1.102 1.000 0.900 39922.6 ' Y i ******************************************************************************* WATER HEATING __= BASE ___ It __= AS -BUILT =__ -------------------------------_------------------------------------------------ ------------------------------------------------------------------------------- NUM OF'1 x MULT = TOTAL !"TANK VOLUME EF TANK x MULT x CREDIT = TOTAL BEDRMS ! RATIO MULT ----- ------------------------------------------------------------------------- 5 I 3527.0 17635.0 ! 80 0.88 1.000 3527.0 0.62 10933.7 ***************************7t*************************************************** SUMMARY ******************************************************************************* BASE ___ ! __= AS -BUILT COOLING HEATING HOT WATER TOTAL ! COOLING HEATING HOT WATER TOTAL POINTSi + POINTS + POINTS = POINTS ! POINTS + POINTS + POINTS = POINTS ------------------------------------------------------------------------------- I 62661.9 30439.3 17635.0 110736.2 1 55508.1 39922.6 10933.7 106364.4 ------------------------------------------------------------------------------- I ***************** * EPI = 96.1 *****************