HomeMy WebLinkAboutENERGY EFFICIENCY CODEMAKHNI RESIDENCE
FLORIDA ENERGY EFFICIENCY CODE
• FOR BUILDING CONSTRUCTION
Section 9 Compliance Program --Residential Point System
Method
Version 2.0 January, 1989
" Department of Community Affairs
Printout generated by EPI89 and submitted in lieu of Form
900-A-89
THIS COMPLIANCE FORM IS VALID IF SUBMITTED BEFORE JANUARY
1, 1990
---=----------------------------_-----------------------------------------------
PROJEC`I' NAME: M�KF'!'N I .R�SI
D�I PERMITTING OFFICE:
-----------
ANDI ADDRESS: 33 �3 ►?/,�/(%�� �j�. I CLIMATE ZONE:
--
4 5 6
-- - ------ I-------------
BUIILDER : Tfla N k_Cd jx e��W / G' i PERMIT NO.:
--------------
------------------------------ I
I JURISDICTION NO.:
OWN11ER: l----------------------
----
---'----------------------------------------------------------------------------
BUILDING OFFICIAL
COMPONENT VALUE CHECKLIST
STRUCTURE TYPE:
�����
Single -Family
BY
PREDOMINANT EVE OVERHANG Length: 3.00
at Lucie County
PORCH OVERHANG Length: 16.00
WINDOWS
Single Tint Total Area: 1812.2
Double Tint Total Area: 45.0
WALLS
1.; Ext NormWtBlock Int Area: 3118.0
R-Value: 8.2
2.1 Ext Wood Frame Area: 240.0
R-Value: 11.0
3.! Adj Wood Frame - Area: 396.0
R-Value: 11.0
DOORS
1.1 Ext Insulated Area: 40.0
2.1 Adj Insulated Area: 20.0
CEILINGS
1.1 FLAT Under Attic Area: 2692.0
i R-Value: 19.0
2: PITCHED Under Attic Area: 693.0
R-Value: 19.0
FLOORS
li Slab -on -Grade Perim: 253.0
R-Value: 0.0
DUCTS
Uncond. Space Length: ALL 7
R-Value: 6.0
COOLING
1. Central A/C SEER: 10'.00
_
Multizone: Credit
Ceiling Fan: Credit
HEATING ,
1!. Strip Heat STRIP: 1.00 i
Multizone: Credit
HOT WATER
Bedrooms: 5
1.
Electric EF: 0.88
Heat Recovery: w/A.C.
INFILTRATION
Practice: 2
Conditioned Floor Area: 6032.0
AS BUILT'POINTS / BASE POINTS * 100 =
EPI %
106364.4 110736.2
96.1 /
GLASS TO FLOOR AREA RATIO = 0.3079
** PRESCRIPTIVE
MEASURES
(Must be met or exceeded by all residences) **
COMPONENTS
SECTION
REQUIREMENTS
WINDOWS
904.1
Maximum of 0.5 CFM per linear foot of operable
sash crack.
--------------------------------------------------------------------------------
EXTERIOR &
904.1
Maximum of 0.5 CFM per sq. ft. of door area.
ADJACENT DOORS
Includes sliding glass doors, solid core,
wood panel, insulated, or glass doors only.
-------------------------------------------------------------------------------
EXT. JOINTS &
904.1
To be caulked, gasketed, weatherstripped or
CRACKS I
otherwise sealed.
-------------------------------------------------------------------------------
WATER HEATERS
904.2
Must bear label indicating compliance w/ASHRAE
standard 90 or comply with efficiency and
standby loss requirements. Switch or clearly
marked circuit breaker (electric), or -cut-off
(gas) must be provided. An external or built
-------------------------------------------------------------------------------
in heat trap must be provided.
SWIMMING POOLS 904.3 Spas and heated pools must have covers (except
& SPAS solar heated). Non-commercial pools must have
a pump timer. Gas spa & pool heaters must have
minimum thermal efficiency of 75%
------'------------------------------------------------------------------------
HOT WATER
904.4
Insulation is required only for recirculating
PIPES
systems. In such cases, piping heat loss shall
be limited to 17.5 BTU/H/Linear Ft. of pipe.
-------------------------------------------------------------------------------
SHOWERIHEADS
904.5
Water flow must be restricted to no more than 3
Igallons
per minute at 80 PSIG.
----- -------------------------------------------------------------------------
HVAC DUCT
903.2
Constructed in accordance with industry
CONSTRUCTION
904.6
standards & local mechanical codes. Ducts in
Unconditioned space must be insulated to
minimum R-4.2 & joints must be sealed.
------,------------------------------------------------------------------------
HVAC CONTROLS
904.7
Separate readilyaccessible manual or automatic
thermostat for each system.
INSULATION
904.9
Ceilings -Min R-19.
Common Walls - Frame R-11 or CBS R-3.
Frame Common Ceilings & Floors R-11.
` ** INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST **
-------'--- ---------------------------------------------
COMPONENTS REQUIREMENTS
PRACTICE #2 Comply with Practice #1 and the following.
-------T---- -------------------------------------------------------------------
Exterior` Walls & Floors Top plate penetrations sealed. Infiltration
barrier installed. Sole plate/floor joint
caulked or sealed.
Exterioi Walls & Ceilings Penetrations, joints and cracks on interior
surface caulked, sealed, and gasketed
Ductwork Ductwork in unconditioned space must be sealed.
Fireplaices Equipped with outside combustion air, doors,
and flue dampers.
Exhaus Fans Equipped with dampers. Combustion devices
see 903.2 (f).
Combustion Appliances Provided with outside combustion air.
------'------------------------------------------------------------------------
-------------------------------------------------------------------------------
In Accordance with Sec. 553.907 F.S., I Review of the plans and specifications
I Hereby certify that the plans and I covered by this calculation indicates
specifications covered by this calcu- I compliance with the Florida Energy
lationIare in compliance with the I Code. Before construction is completed
Florida Energy Code. I this building will be inspected for
I compliance in accordance with Section
1553.908 F.S.
i
OW*FrR/ GENT: BUILDING OFFICIAL:
%gyp
DNIIE : 9� �/ W 1 DATE:
xxxxxxxxxxxxXxxxxxxxxxxxxxxxxxxxxXxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
SUMMER
CALCULATIONS
BASE ___
{
__=
AS -BUILT
GL-ASS________________________�_________________________________________________
ORIEN AREA
x BSPM
= POINTS
I TYPE SC
ORIEN AREA
x SPM
x SOF
= POINTS
---'----------------------------------------------------------------------------
N: 224.0
47.8
10707.2
1 SGL
TINT
N
128.0
51.5
0.78
5135.8
{ SGL
TINT
N
96.0
51.5
0.85
4207.9
NE 191.0
71.7
13694.7
1 SGL
TINT
NE
64.0
76.6
0.49
2396.7
1 SGL
TINT.
NE
64.0
76.6
0.82
4028.1
1 SGL
TINT
NE
63.0
76.6
0.39
1894.6
E 750.0
102.0
76500.0
1 SGL
TINT
E
96.0
107.1
0.56
5773.5
1 SGL
TINT
E
96.0
107.1
0.84
8613.7
1 SGL
TINT
E
128.0
107.1
0.84
11484..9
1 SGL
TINT
E
36.0
107.1
0.68
2635.8
1 SGL
TINT
E
84.0
107.1
0.68
6150.3
1 SGL
TINT
E
112.0
107.1
0.68
8200.4
1 SGL
TINT
E
198.0
107.1
0.77
16309.2
SE 120.0
104.1'
12492.0
1 SGL
TINT
SE
120.0
110.3
0.71
9349.4
S 169.0
90.9
15362.1
1 SGL
TINT
S
144.0
98.3
0.99
.13949.1
I SGL
TINT
S
25.0
98.3
0.97
2381.5
SW 74.0
104.1
7703.4
1 SGL
TINT
SW
31.0
110.3
0.62
2118.7
1 SGL
TINT
SW
43.0
110.3
0.42
1992.0
W 284.2
102.0
28988.4
1 SGL
TINT
W
25.0
107.1
0.83
2225.6
1 SGL
TINT
W
93.0
107.1
0.64
6336.7
1 SGL
TINT
W
93.2
107.1
0.41
4092.5
1 SGL
TINT
W
13.0
107.1
0.70
974.2
1 SGL
TINT
W
35.0
107.1
0.62
2321.2
I SGL
TINT
W
25.0
107.1
0.98
2631.5
NW 45.0
71.7
3226.5
1 DBL
TINT
NW
45.0
63.4
0.58
1662.1
--I --------------------------------------------------------------------
.115 x COND.
FLOOR /
TOTAL GLASS = ADJ. x GLASS
= ADJ
GLASS
{
GLASS
AREA
i
-------------------------------------------------------------------------------
AREA
FACTOR POINTS
POINTS
I
POINTS
I
.15 6032.0
1857.2
0.487 168674.3
82175.6
1
126865.4
AREA
I
------------------------------------------------------------------------------
x BSPM
= POINTS
1
I TYPE
R-VALUE
AREA x
SPM
= POINTS
WALLS-----------
I
Ext 3358.0
1.00
3358.0
1 Ext
NormWtBlock
Int
8.2 3118.0
0.68
2120.2
1 Ext
Wood Frame
11.0
240.0
1.90
456.0
Adj 396.0
0.70
277.2
1 Adj
Wood Frame
11.0
396.0
0.70
277.2
DiOORS-----------
I
Ext 40.0
4.80
192.0
I Ext
Insulated
40.0
4.80
192.0
Idj 20.0
1.60
32.0
1 Adj
Insulated
20.0
1.60
32.0
CEILINGS----------
1
I
UA 3312.0
0.60
1987.2
1 Under Attic
19.0 2692.0
1.10
2961.2
I
1 Under Attic
19.0
693.0
1.10
762.3
FLOORS----------
I
I
Slb 253.0
-31.80
-8045.4
1 Slab -on -Grade
0.0
253.0 -31.90
-8070.7
INFILTRATION ---------
6032.0 10.90 65748.8 1 Practice #2 6032.0 10.90 65748.8
TOTAL SUMMER POINTS I
145725.4 1 191344
------------
1
'TOTAL x SYSTEM = COOLING I TOTAL x CAP x DUCT x SYSTEM x CREDIT = COOLING
SUM PTS MULT POINTS I COMPON RATIO MULT MULT MULT POINTS
-------------------------------------------------------------------------------
145725.4 0.43 62661.9 1 191344.5 1.000 1.102 0.340 0.774 55508
------------------------------------------
xxx*�XXxxx*xxxxxxxxX*x***x**x***X**x**X***xxxxxxx****x*xx*xxxx*xxxx*xx*xx*xxxxxx
D
WINTER CALCULATIONS
•X*X*,*XX*,XX***Yc**XXX*XXXX**X******XX***X*X**XX******XX**XX****xX**XX*X****,X**XX*
BASE __=
I
=_=
AS -BUILT
-GeLASS------------
I
ORIEN AREA
x BWPM =
POINTS I
TYPE SC ORIEN
AREA
x WPM
x WOF
= POINTS
--- 7---------------------------------------------------------------------------
NI 224.0
5.6
1254.4 1
SGL TINT
N
128.0
9.6
1.14
1395.2
I
1
SGL TINT
N
96.0
9.6
1.09
1004.0
NEi 191.0
3.5
668.5 1
SGL TINT
NE
64.0
7.3
1.51
705.5
!
{
SGL TINT
NE
64.0
7.3
1.17
548.3
I
SGL TINT
NE
63.0
7.3
1.60
738.0
E
750.0
-5.6
-4200.0 I
SGL TINT
E
96.0
-2.0
-1.65
316.7
I
SGL TINT
E
96.0
-2.0
0.12
-23.4
I
SGL TINT
E
128.0
-2.0
0.12
-31.2
I
SGL TINT
E
36.0
-2.0
-0.76
54.7
I
SGL TINT
E
84.0
-2.0
-0.76
127.5
I
SGL TINT
E
112.0
-2.0
-0.76
170.0
I
SGL TINT
E
198.0
-2.0
-0.26
103.5
SEi 120.0
-13.4
-1608.0 1
SGL TINT
SE
120.0
-9.7
0.66
-769.3
S' 169.0
-14.0
-2366.0 1
SGL TINT
S
144.0
-10.2
0.99
-1456.9
I
SGL TINT
S
25.0
-10.2
0.98
-250.6
SWI 74.0
-13.4
-991.6 1
SGL TINT
SW
3.1.0
-9.7
0.54
-162.1
1
1
SGL TINT
SW
43.0
-9.7
0.05
-20.9
W
284.2
-5.6
-1591.5 1
SGL TINT
W
25.0
-2.0
0.09
-4.3
1
SGL TINT
W
93.0
-2.0
-1.08
200.4
I
SGL TINT
W
93.2
-2.0
-3.13
582.8
I
SGL TINT
W
13.0
-2.0
-0.65
17.0
I
SGL TINT
W
35.0
-2.0
-1.20
83.9
I
SGL TINT
W
25.0
-2.0
0.90
-45.0
NW 45.0
3.5
157.5 1
DBL TINT
NW
45.0
4.2
1.63
307.4
------------------------------------------------------------------------------
.15 x COND.
FLOOR /
TOTAL GLASS
= ADJ. x GLASS
= ADJ
GLASS
I
GLASS
AREA
AREA
FACTOR POINTS
POINTS
I
POINTS
--=----------------------------------------------------------------------------
.15 6032.0
i
1857.2
0.487-8676.7
-4227.2
I
3591.2
BWPM
-------------
I
= POINTS -I--TYPE
------------R_VALUE
-------------------------
AREA
x WPM
= POINTS
------AREA--x
WALLS-----------
1
Ext 3358.0
1.10
3693.8 I
Ext NormWtBlock
Int
8.2
3118.0
2.06
6423.1
I
I
Ext Wood Frame
11.0
240.0
2.00
480.0
Adj 396.0
1.80
712.8 I
Adj Wood Frame
11.0
396.0
1.80
712.8
j
DOORS-----------
I
I
.
Ext 40.0
5.10
204.0 I
Ext Insulated
40.0
5.10
204.0
Adij
20.0
4.00
80.0.{
Adj Insulated
20.0
4.00
80.0
CEILINGS----------
I
I
UA 3312.0
0.60
1987.2 1
Under Attic
19.0
2692.0
1.00
2692.0
I
Under Attic
19.0
693.0
1.0.0
693.0
FLOORS ----=-----
I
I
Slb 253.0
-1.90
-480.7 1
Slab -on -Grade
0.0
253.0
2.50
632.5
INFILTRATION---------
I
6032.0
4.10
24731.2 1
Practice #2
6032.0
4.10
24731.2
TOTAL WINTER
POINTS I
26701.1 1
40239.8
TOTAL x SYSTEM
=
1
HEATING 1
TOTAL x CAP x
DUCT
x SYSTEM
x CREDIT
=
HEATING
WIN PTS
MULT
POINTS I
COMPON RATIO
MULT
MULT
MULT
POINTS
-=-----------------------------------------------------------------------------
26701.1
1.14
30439.3 1
40239.8 1.000
1.102
1.000
0.900
39922.6
' Y i
*******************************************************************************
WATER HEATING
__= BASE ___ It __= AS -BUILT =__
-------------------------------_------------------------------------------------
-------------------------------------------------------------------------------
NUM OF'1 x MULT = TOTAL !"TANK VOLUME EF TANK x MULT x CREDIT = TOTAL
BEDRMS ! RATIO MULT
----- -------------------------------------------------------------------------
5 I 3527.0 17635.0 ! 80 0.88 1.000 3527.0 0.62 10933.7
***************************7t***************************************************
SUMMARY
*******************************************************************************
BASE ___ ! __= AS -BUILT
COOLING HEATING HOT WATER TOTAL ! COOLING HEATING HOT WATER TOTAL
POINTSi + POINTS + POINTS = POINTS ! POINTS + POINTS + POINTS = POINTS
-------------------------------------------------------------------------------
I
62661.9 30439.3 17635.0 110736.2 1 55508.1 39922.6 10933.7 106364.4
-------------------------------------------------------------------------------
I
*****************
* EPI = 96.1
*****************